Qiangjun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qiangjun Zhang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Colin G. Bailey
Queen Mary University of London, London, UK
3 shared publications- Constantinos Soutis
Department of Materials, The University of Manchester, Manchester M13 9PL, UK
2 shared publications Yong C. Wang
2 shared publications- Biao Wang
Research Institute of Interdisciplinary Science & School of Materials Science and Engineering, Dongguan University of Technology, Dongguan 523808, China
1 shared publication - Cristina Vallés
University of Manchester
1 shared publication Ian A. Kinloch
1 shared publication
Latest Publications
- 1 October 2020
- Published by Cambridge University Press (CUP) in The Aeronautical Journal
- Vol. 125 (1283) , 205-222
Development of a fire detection and suppression system for a smart air cargo container
This study investigates and proposes a fire detection and suppression system for a smart air cargo container. A series of smoke spread and fire evolution numerical models are executed to assess the performance of container-based fire detection in various fire scenarios. This is to identify the worst case and optimise the location and threshold setting of fire detection sensors, achieving the shortest detection time. It is found that the fire detection threshold (reduction in light transmission = 12%/ft) for a container-based system can be set at three times the standard activation threshold for a cargo-based fire detection system, which can reduce the number of false alarms by three orders of magnitude. Moreover, effectiveness analysis of passive fire protection for the glass fibre-reinforced polymer-made smart container indicates an allowable leakage size of 0.01m2. The risk of internal overpressure has been found to be negligible for the leakage size required by aircraft pressure equalisation.
- 1 October 2020
- Published by Cambridge University Press (CUP) in The Aeronautical Journal
- Vol. 125 (1283) , 205-222
Development of a fire detection and suppression system for a smart air cargo container
This study investigates and proposes a fire detection and suppression system for a smart air cargo container. A series of smoke spread and fire evolution numerical models are executed to assess the performance of container-based fire detection in various fire scenarios. This is to identify the worst case and optimise the location and threshold setting of fire detection sensors, achieving the shortest detection time. It is found that the fire detection threshold (reduction in light transmission = 12%/ft) for a container-based system can be set at three times the standard activation threshold for a cargo-based fire detection system, which can reduce the number of false alarms by three orders of magnitude. Moreover, effectiveness analysis of passive fire protection for the glass fibre-reinforced polymer-made smart container indicates an allowable leakage size of 0.01m2. The risk of internal overpressure has been found to be negligible for the leakage size required by aircraft pressure equalisation.
- Open Access
- 14 July 2020
- Published by Springer Nature in Applied Composite Materials
- Vol. 27 (5) , 619-639
Fire Safety Assessment of Epoxy Composites Reinforced by Carbon Fibre and Graphene
This paper presents a coupled numerical investigation to assess the reaction to fire performance and fire resistance of various types of epoxy resin (ER) based composites. It examines the fire response of carbon fibre (CF) reinforced ER (CF/ER), ER with graphene nanoplatelets (GNP/ER) and CF reinforced GNP/ER (CF/GNP/ER). Thermal, physical and pyrolysis properties are presented to assist numerical modelling that is used to assess the material ability to pass the regulatory vertical burn test for new aircraft structures and estimate in-fire and post-fire residual strength properties.Except for the CF/GNP/ER composite, all other material systems fail the vertical burn test due to continuous burning after removal of the fire source. Carbon fibres are non-combustible and therefore reduce heat release rate of the ER composite. By combining this property with the beneficial barrier effects of graphene platelets, the CF/GNP/ER composite with 1.5 wt% GNP and 50 wt% CF self-extinguishes within 15 s after removal of the burner with a relatively small burn length. Graphene drastically slows down heat conduction and migration of decomposed volatiles to the surface by creating improved char structures. Thus, graphene is allowing the CF/GNP/ER composite panel to pass the regulatory vertical burn test.Due to low heat conduction and reduced heat release rate, the maximum temperatures in the CF/GNP/ER composite are low so the composite material retains very high in-fire and post-fire mechanical properties, maintaining structural integrity. In contrast, temperatures in the CF/ER composite are much higher. At a maximum temperature of 86 °C, the residual in-fire tensile and compressive mechanical strengths of CF/GNP/ER are about 87% and 59% respectively of the ambient temperature values, compared to 70% and 21% respectively for the CF/ER composite that has a temperature of 140 °C at the same time (but the CF/ER temperature will be higher due to continuing burning). Converting mass losses of the composites into char depth, the post-fire mechanical properties of the CF/GNP/ER composite are about 75% of the ambient condition compared to about 68% for the CF/ER composite.
- 14 July 2020
- Published by Springer Nature in Applied Composite Materials
- Vol. 27 (5) , 619-639
Open AccessFire Safety Assessment of Epoxy Composites Reinforced by Carbon Fibre and Graphene
This paper presents a coupled numerical investigation to assess the reaction to fire performance and fire resistance of various types of epoxy resin (ER) based composites. It examines the fire response of carbon fibre (CF) reinforced ER (CF/ER), ER with graphene nanoplatelets (GNP/ER) and CF reinforced GNP/ER (CF/GNP/ER). Thermal, physical and pyrolysis properties are presented to assist numerical modelling that is used to assess the material ability to pass the regulatory vertical burn test for new aircraft structures and estimate in-fire and post-fire residual strength properties.Except for the CF/GNP/ER composite, all other material systems fail the vertical burn test due to continuous burning after removal of the fire source. Carbon fibres are non-combustible and therefore reduce heat release rate of the ER composite. By combining this property with the beneficial barrier effects of graphene platelets, the CF/GNP/ER composite with 1.5 wt% GNP and 50 wt% CF self-extinguishes within 15 s after removal of the burner with a relatively small burn length. Graphene drastically slows down heat conduction and migration of decomposed volatiles to the surface by creating improved char structures. Thus, graphene is allowing the CF/GNP/ER composite panel to pass the regulatory vertical burn test.Due to low heat conduction and reduced heat release rate, the maximum temperatures in the CF/GNP/ER composite are low so the composite material retains very high in-fire and post-fire mechanical properties, maintaining structural integrity. In contrast, temperatures in the CF/ER composite are much higher. At a maximum temperature of 86 °C, the residual in-fire tensile and compressive mechanical strengths of CF/GNP/ER are about 87% and 59% respectively of the ambient temperature values, compared to 70% and 21% respectively for the CF/ER composite that has a temperature of 140 °C at the same time (but the CF/ER temperature will be higher due to continuing burning). Converting mass losses of the composites into char depth, the post-fire mechanical properties of the CF/GNP/ER composite are about 75% of the ambient condition compared to about 68% for the CF/ER composite.
- 1 November 2019
- Published by Elsevier in Composites Science and Technology
- Vol. 184
Quantification of gas permeability of epoxy resin composites with graphene nanoplatelets
- 1 November 2019
- Published by Elsevier in Composites Science and Technology
- Vol. 184
Quantification of gas permeability of epoxy resin composites with graphene nanoplatelets
- 1 August 2018
- Published by Elsevier in Composites Part B: Engineering
- Vol. 146, 76-87
Quantifying effects of graphene nanoplatelets on slowing down combustion of epoxy composites
- 1 August 2018
- Published by Elsevier in Composites Part B: Engineering
- Vol. 146, 76-87
Quantifying effects of graphene nanoplatelets on slowing down combustion of epoxy composites
- 1 May 2014
- Published by Elsevier in Materials Research Bulletin
- Vol. 53, 272-279
The influence of α-FeOOH/rGO hybrids on the improved thermal stability and smoke suppression properties in polystyrene
- 1 May 2014
- Published by Elsevier in Materials Research Bulletin
- Vol. 53, 272-279
The influence of α-FeOOH/rGO hybrids on the improved thermal stability and smoke suppression properties in polystyrene