Michal Orkisz
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michal Orkisz has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Sachit Butail
Northern Illinois University
2 shared publications - Anna Stief
ABB Corporate Research Center, ul. Starowislna 13a, 31-038, Krakow, Poland
1 shared publication Artur Szewczuk
ABB Corporate Technology Center, Krakow, Poland
1 shared publication- Christophe Simon
Département GEII-IUT Nancy Brabois, Université de Lorraine, CRAN CNRS UMR 7039, Campus Sciences, BP 70239, 54506 Vandoeuvre-les-Nancy Cedex, France
1 shared publication - Didier Theilliol
University of Lorraine
1 shared publication Dominique Sauter
Université de Lorraine, CRAN, UMR 7039, Campus Sciences, B.P. 70239, Vandoeuvre-les-Nancy Cedex 54506, France
1 shared publication
Latest Publications
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 15, 217-221
Inspecting Static Frequency Converter Station with Thermography
Static Frequency Converter stations are becoming an important part of energy infrastructure. It is crucial to maintain their health and performance. One of versatile health indicators is temperature – many failure modes are associated with abnormal temperatures. As an operating station is off-limits to people, for safety reasons, it is important to be able to measure the temperatures at a distance. This paper describes measurements carried out at a small test Static Frequency Converter station using a hand-held thermal camera. Investigated equipment included valves, reactor coils, filter resistors, cooling system, joints, structure elements. The station was operating at rated voltage, but minimal power, therefore not all measurements were expected to be significant. Nevertheless, a number of anomalies has been detected, proving the usefulness of thermography in station diagnostics.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 15, 217-221
Inspecting Static Frequency Converter Station with Thermography
Static Frequency Converter stations are becoming an important part of energy infrastructure. It is crucial to maintain their health and performance. One of versatile health indicators is temperature – many failure modes are associated with abnormal temperatures. As an operating station is off-limits to people, for safety reasons, it is important to be able to measure the temperatures at a distance. This paper describes measurements carried out at a small test Static Frequency Converter station using a hand-held thermal camera. Investigated equipment included valves, reactor coils, filter resistors, cooling system, joints, structure elements. The station was operating at rated voltage, but minimal power, therefore not all measurements were expected to be significant. Nevertheless, a number of anomalies has been detected, proving the usefulness of thermography in station diagnostics.
- 21 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 1547-1556
Spectrum Shape Based Roller Bearing Fault Detection and Identification
This paper describes a combination of numerical methods of automated fault detection and identification in rolling bearings, even when there is a limited knowledge about inspected bearings and their characteristic frequencies in particular. The most important feature is global approach to solving the stated problem using several rolling bearing diagnostic methods and techniques which work simultaneously and complement each other. These include the well-known Hilbert-based envelope, Discrete Wavelet Transform and Fourier Transform as well as new Outer Envelope Filtering, Pulse Train Scanning, spectrum shape analysis and novel application of known signal processing tools like Fuzzy Logic and Continuous Wavelet Transform. Combination of partial results obtained by each path allows for judging the probabilities of different fault types (outer-race, inner-race and roller). Two techniques additionally used here are spectrum scanning by a train of harmonic pulses (Pulse Train Scanning) and an outer envelope filter which removes high frequency noise, but enhances the most important short time diagnostic symptoms, which are often removed by standard filtering. A combination of such solutions allows for unambiguous and precise localization of characteristic fault frequencies in a spectrum without initial knowledge about their expected values.
- 21 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 1547-1556
Spectrum Shape Based Roller Bearing Fault Detection and Identification
This paper describes a combination of numerical methods of automated fault detection and identification in rolling bearings, even when there is a limited knowledge about inspected bearings and their characteristic frequencies in particular. The most important feature is global approach to solving the stated problem using several rolling bearing diagnostic methods and techniques which work simultaneously and complement each other. These include the well-known Hilbert-based envelope, Discrete Wavelet Transform and Fourier Transform as well as new Outer Envelope Filtering, Pulse Train Scanning, spectrum shape analysis and novel application of known signal processing tools like Fuzzy Logic and Continuous Wavelet Transform. Combination of partial results obtained by each path allows for judging the probabilities of different fault types (outer-race, inner-race and roller). Two techniques additionally used here are spectrum scanning by a train of harmonic pulses (Pulse Train Scanning) and an outer envelope filter which removes high frequency noise, but enhances the most important short time diagnostic symptoms, which are often removed by standard filtering. A combination of such solutions allows for unambiguous and precise localization of characteristic fault frequencies in a spectrum without initial knowledge about their expected values.
- 16 July 2021
- Published by ASME International in ASME Letters in Dynamic Systems and Control
- Vol. 2 (1) , 1-23
A Transfer Entropy Based Approach for Fault Isolation in Industrial Robots
In this paper, we cast the problem of fault isolation in industrial robots as that of causal analysis within coupled dynamical processes and evaluate the related efficacy of the information-theoretic approach of transfer entropy. To create a realistic and exhaustive dataset, we simulate wear-induced failure by increasing friction coefficient on select axes within an in-house robotic simulation tool that incorporates an elastic gearbox model. The source axis of failure is identified as one which has the highest net transfer entropy across all pairs of axes. In an exhaustive simulation study, we vary the friction successively in each axis across three common industrial tasks: pick and place, spot welding, and arc welding. Our results show that transfer entropy-based approach is able to detect the axis of failure more than 80% of the time when the friction coefficient is 5% above the nominal value and always when friction coefficient is 10% above the nominal value. The transfer entropy approach is more than twice as accurate as cross-correlation, a classical time series analysis used to identify directional dependence among processes.
- 16 July 2021
- Published by ASME International in ASME Letters in Dynamic Systems and Control
- Vol. 2 (1) , 1-23
A Transfer Entropy Based Approach for Fault Isolation in Industrial Robots
In this paper, we cast the problem of fault isolation in industrial robots as that of causal analysis within coupled dynamical processes and evaluate the related efficacy of the information-theoretic approach of transfer entropy. To create a realistic and exhaustive dataset, we simulate wear-induced failure by increasing friction coefficient on select axes within an in-house robotic simulation tool that incorporates an elastic gearbox model. The source axis of failure is identified as one which has the highest net transfer entropy across all pairs of axes. In an exhaustive simulation study, we vary the friction successively in each axis across three common industrial tasks: pick and place, spot welding, and arc welding. Our results show that transfer entropy-based approach is able to detect the axis of failure more than 80% of the time when the friction coefficient is 5% above the nominal value and always when friction coefficient is 10% above the nominal value. The transfer entropy approach is more than twice as accurate as cross-correlation, a classical time series analysis used to identify directional dependence among processes.
- 23 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 16 (1) , 193-201
Data-Driven Gearbox Failure Detection in Industrial Robots
Gearbox failures cost thousands of lost production hours in plants that use industrial robots. In this context, an automated monitoring system that can warn the user of an impending failure can save precious resources. This problem has been addressed in many other domains through the use of machine learning approaches. However, standard machine learning algorithms are limited in their ability to detect gearbox failures, mainly due to task variability arises from robot-specific data. To improve detection performance of machine learning approaches, we propose techniques to curate the data prior to building a classification model. In a systematic hypothesis-driven study exploring the effect of different preprocessing techniques, we evaluate training data augmentation with estimated measurements, data differencing to suppress task dependence, inclusion of local variation, and selection of principal components on data collected from 26 industrial robots from the field. Our results show that preprocessing techniques improve the failure detection performance.
- 23 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 16 (1) , 193-201
Data-Driven Gearbox Failure Detection in Industrial Robots
Gearbox failures cost thousands of lost production hours in plants that use industrial robots. In this context, an automated monitoring system that can warn the user of an impending failure can save precious resources. This problem has been addressed in many other domains through the use of machine learning approaches. However, standard machine learning algorithms are limited in their ability to detect gearbox failures, mainly due to task variability arises from robot-specific data. To improve detection performance of machine learning approaches, we propose techniques to curate the data prior to building a classification model. In a systematic hypothesis-driven study exploring the effect of different preprocessing techniques, we evaluate training data augmentation with estimated measurements, data differencing to suppress task dependence, inclusion of local variation, and selection of principal components on data collected from 26 industrial robots from the field. Our results show that preprocessing techniques improve the failure detection performance.
- Open Access
- 14 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (12) , 9510-9520
A PCA and Two-Stage Bayesian Sensor Fusion Approach for Diagnosing Electrical and Mechanical Faults in Induction Motors
Induction motors are widely used in industrial plants for critical operations. Stator faults, bearing faults or rotor faults can lead to unplanned downtime with associated cost and safety implications. Different sensors may be used to monitor the health state of induction motors with each sensor typically being better suited to diagnosing different faults. Condition monitoring approaches which fuse data from multiple sensors have the potential to diagnose a greater number of faults. A sensor fusion approach based on the combination of a two-stage Bayesian method and Principal Component Analysis is proposed for diagnosing both electrical and mechanical faults in induction motors. Acoustic, electric and vibration signals are gathered from motors operating under different loading conditions and health states. The inclusion of the PCA step ensures robustness to varying loading conditions. The obtained results highlight that the proposed method performs better than equivalent single stage or feature-based Bayesian methods.
- 14 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (12) , 9510-9520
Open AccessA PCA and Two-Stage Bayesian Sensor Fusion Approach for Diagnosing Electrical and Mechanical Faults in Induction Motors
Induction motors are widely used in industrial plants for critical operations. Stator faults, bearing faults or rotor faults can lead to unplanned downtime with associated cost and safety implications. Different sensors may be used to monitor the health state of induction motors with each sensor typically being better suited to diagnosing different faults. Condition monitoring approaches which fuse data from multiple sensors have the potential to diagnose a greater number of faults. A sensor fusion approach based on the combination of a two-stage Bayesian method and Principal Component Analysis is proposed for diagnosing both electrical and mechanical faults in induction motors. Acoustic, electric and vibration signals are gathered from motors operating under different loading conditions and health states. The inclusion of the PCA step ensures robustness to varying loading conditions. The obtained results highlight that the proposed method performs better than equivalent single stage or feature-based Bayesian methods.
- 29 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 4825-4832
Estimating Effects of Individual PV Panel Failures on PV Array Output
Photovoltaic plants are becoming an ever more popular source of energy. While individual PV panels are quite resilient, failures do happen. Due to the arrangement of interconnections between multiple PV panels in an array and the Maximum Power Point Tracking mechanism, a failure of a single panel can influence the output of the whole ensemble. This work estimates the impact of a single panel short circuit failure on the output of a series-parallel array. Generally, the array power loss is larger than the contribution of the failed panel. The dependency of this increase on various factors, such as the number of panels / strings, the shape of the current-voltage curve of the panels, and the degree of panel inhomogeneities is investigated. This increase is found to depend most significantly on the shape of the I-V curve of the panel, and only weakly on a range of other parameters. It is, therefore, useful in estimating the impact of panel failures without the need to know many details about the system.
- 29 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 4825-4832
Estimating Effects of Individual PV Panel Failures on PV Array Output
Photovoltaic plants are becoming an ever more popular source of energy. While individual PV panels are quite resilient, failures do happen. Due to the arrangement of interconnections between multiple PV panels in an array and the Maximum Power Point Tracking mechanism, a failure of a single panel can influence the output of the whole ensemble. This work estimates the impact of a single panel short circuit failure on the output of a series-parallel array. Generally, the array power loss is larger than the contribution of the failed panel. The dependency of this increase on various factors, such as the number of panels / strings, the shape of the current-voltage curve of the panels, and the degree of panel inhomogeneities is investigated. This increase is found to depend most significantly on the shape of the I-V curve of the panel, and only weakly on a range of other parameters. It is, therefore, useful in estimating the impact of panel failures without the need to know many details about the system.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 60 (10851992) , 1202-1207
Remaining useful life assessment via residual generator approach — A SOH virtual sensor concept
Based on analytical redundancy, specific set of residuals are designed to be sensitive to each component fault. The residual set may then represent as a measure of the loss of performance of the component in the system and thus, reflect the state of health of the component. The dynamic evolution of the residual can be considered as an image of the evolution of the component health, and can be modeled as the response of the component to the stress factors and the natural aging. The residual represents a degradation virtual sensor. Based on this prediction related to the various stress factors, the range of possible values of the remaining useful life (RUL) of the component can be predicted. The main contribution of the proposed paper is to present a new approach for RUL estimation based on a State Of Health degradation virtual sensor design. The range of values of the RUL can supply downstream applications for decision aids in maintenance or control. For illustration, the proposed approach was applied to the RUL prediction of actuators in a function of stress factors.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 60 (10851992) , 1202-1207
Remaining useful life assessment via residual generator approach — A SOH virtual sensor concept
Based on analytical redundancy, specific set of residuals are designed to be sensitive to each component fault. The residual set may then represent as a measure of the loss of performance of the component in the system and thus, reflect the state of health of the component. The dynamic evolution of the residual can be considered as an image of the evolution of the component health, and can be modeled as the response of the component to the stress factors and the natural aging. The residual represents a degradation virtual sensor. Based on this prediction related to the various stress factors, the range of possible values of the remaining useful life (RUL) of the component can be predicted. The main contribution of the proposed paper is to present a new approach for RUL estimation based on a State Of Health degradation virtual sensor design. The range of values of the RUL can supply downstream applications for decision aids in maintenance or control. For illustration, the proposed approach was applied to the RUL prediction of actuators in a function of stress factors.
- 30 November 2013
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 40 (2) , 439-451
Dependence structure analysis of the inverter operational data by means of copula theory
- 30 November 2013
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 40 (2) , 439-451