Fahmi Samsuri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fahmi Samsuri has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- John J. Evans
Christchurch School of Medicine and Health Sciences, University of Otago, Christchurch 8041, New Zealand
5 shared publications - John S. Mitchell
The New Zealand Institute for Plant and Food Research Ltd
3 shared publications Maan M. Alkaisi
MacDiarmid Institute for Advanced Materials and Nanotechnology, Department of Electrical and Computer Engineering, University of Canterbury, Private Bag 4800, Christchurch, NEW ZEALAND
3 shared publications- Maan M. Alkaisi
Department of Electrical and Computer Engineering, University of Canterbury, Christchurch 8041, New Zealand
3 shared publications - Mahfuzah Mustafa
Universiti Malaysia Pahang Al-Sultan Abdullah
2 shared publications - Norizam Sulaiman
Universiti Malaysia Pahang Al-Sultan Abdullah
2 shared publications
Latest Publications
- 2 October 2024
- Published by Springer Nature
- p. 335-345
Face Detection Through Conceal with Deep Learning
- 2 October 2024
- Published by Springer Nature
- p. 335-345
Face Detection Through Conceal with Deep Learning
- 2 October 2024
- Published by Springer Nature
- p. 325-333
The Design and Analysis of Fast Fourier Transform Processor Using VLSI Technique
- 2 October 2024
- Published by Springer Nature
- p. 325-333
The Design and Analysis of Fast Fourier Transform Processor Using VLSI Technique
- 2 October 2024
- Published by Springer Nature
- p. 347-357
Design and Analysis of an Early Diabetes Mellitus Detection Using OpenCV
- 2 October 2024
- Published by Springer Nature
- p. 347-357
Design and Analysis of an Early Diabetes Mellitus Detection Using OpenCV
- 18 April 2024
- Published by Springer Nature
- p. 225-237
Human Mental Stage Interpretation Based on the Analysis of Electroencephalogram (EEG) Signals
- 18 April 2024
- Published by Springer Nature
- p. 225-237
Human Mental Stage Interpretation Based on the Analysis of Electroencephalogram (EEG) Signals
- Open Access
- 8 July 2020
- Published by Springer Nature
- p. 965-980
Offline EEG-Based DC Motor Control for Wheelchair Application
- 8 July 2020
- Published by Springer Nature
- p. 965-980
Open AccessOffline EEG-Based DC Motor Control for Wheelchair Application
- 31 August 2011
- Published by Elsevier in Microelectronic Engineering
- Vol. 88 (8) , 1828-1831
Microfluidic arrays for bioimprint of cancer cells
- 31 August 2011
- Published by Elsevier in Microelectronic Engineering
- Vol. 88 (8) , 1828-1831
Microfluidic arrays for bioimprint of cancer cells
- 31 August 2011
- Published by Elsevier in Microelectronic Engineering
- Vol. 88 (8) , 1871-1874
Detection of changes in cell membrane structures using the Bioimprint technique
- 31 August 2011
- Published by Elsevier in Microelectronic Engineering
- Vol. 88 (8) , 1871-1874
Detection of changes in cell membrane structures using the Bioimprint technique
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 382-387
Biochip development using nanoimprint lithography (NIL) and metallic thermal evaporation techniques for biological cells manipulation using DEP
A Biochip is a platform of miniaturized microarrays arranged on a solid substrate that permits many tests to be performed at the same time in order to achieve higher throughput and speed. Single-cell identification, imaging and analysis in situ using Atomic Force Microscopy (AFM) faced a lot of difficulties as immobilizing the cells for direct cellular analysis is still a major challenge. One approach to overcome this problem was the use of organized arrangements like microarrays to trap the cells and placed them in a controlled manner. This can be achieved by fabricating these microarrays on a special platform such as Biochip. To manipulate the cells' movements, an electrokinetic phenomenon known as dielectrophoresis (DEP) was used for that purpose. Non-uniform AC electric fields generated by the interdigitated microelectrode arrays provide an ideal method for manipulating and controlling particles. The cells were captured using positive and negative DEP forces in cavities placed at different locations within the electrode arrays. As some cells have no tendency to spread over substrates during culturing, the contact area between the cell and substrate is very small, often leading to cell detachment by the scanning tip. Thus by employing the cavity trapping method, not only the cells were perfectly anchored to the surface but also their heights were lowered to within a set-scan level of the AFM, enabling faster time-to-analysis. This paper reports the development of a new layout for the Biochip electrodes intended for DEP cell manipulations.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 382-387
Biochip development using nanoimprint lithography (NIL) and metallic thermal evaporation techniques for biological cells manipulation using DEP
A Biochip is a platform of miniaturized microarrays arranged on a solid substrate that permits many tests to be performed at the same time in order to achieve higher throughput and speed. Single-cell identification, imaging and analysis in situ using Atomic Force Microscopy (AFM) faced a lot of difficulties as immobilizing the cells for direct cellular analysis is still a major challenge. One approach to overcome this problem was the use of organized arrangements like microarrays to trap the cells and placed them in a controlled manner. This can be achieved by fabricating these microarrays on a special platform such as Biochip. To manipulate the cells' movements, an electrokinetic phenomenon known as dielectrophoresis (DEP) was used for that purpose. Non-uniform AC electric fields generated by the interdigitated microelectrode arrays provide an ideal method for manipulating and controlling particles. The cells were captured using positive and negative DEP forces in cavities placed at different locations within the electrode arrays. As some cells have no tendency to spread over substrates during culturing, the contact area between the cell and substrate is very small, often leading to cell detachment by the scanning tip. Thus by employing the cavity trapping method, not only the cells were perfectly anchored to the surface but also their heights were lowered to within a set-scan level of the AFM, enabling faster time-to-analysis. This paper reports the development of a new layout for the Biochip electrodes intended for DEP cell manipulations.
- 1 November 2010
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 28 (6) , C6K17-C6K22
Microfluidics-assisted photo nanoimprint lithography for the formation of cellular bioimprints
Morphology and surface features provide important markers for cell development and reaction to external stimuli. Bioimprint offers a technique for the permanent capture of these features into an UV-curing, biocompatible, methacrylate biopolymer. This material shows excellent replication fidelity and fast setting times. However, the minimum reproducible feature size depends on the skillful application of the liquid prepolymer. To enable the repeatable formation of high-resolution, structurally bioactive cellular bioimprints, a modified process based on the use of microfluidics for integrated cell culture and polymer delivery has been developed. In this article, the authors introduce the process and demonstrate its use for the culture and imaging of Ishikawa endometrial cancer cells. Transfer of a 100 nm thick Cr test pattern with micrometer-scale features into the biopolymer is demonstrated. Replication and atomic force microscopy imaging of imprinted cellular surface features with sub-50 nm resolution is shown. The process has applications in disease diagnostics, in drug discovery, and for the creation of biomimetic cell culture scaffolds.
- 1 November 2010
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 28 (6) , C6K17-C6K22
Microfluidics-assisted photo nanoimprint lithography for the formation of cellular bioimprints
Morphology and surface features provide important markers for cell development and reaction to external stimuli. Bioimprint offers a technique for the permanent capture of these features into an UV-curing, biocompatible, methacrylate biopolymer. This material shows excellent replication fidelity and fast setting times. However, the minimum reproducible feature size depends on the skillful application of the liquid prepolymer. To enable the repeatable formation of high-resolution, structurally bioactive cellular bioimprints, a modified process based on the use of microfluidics for integrated cell culture and polymer delivery has been developed. In this article, the authors introduce the process and demonstrate its use for the culture and imaging of Ishikawa endometrial cancer cells. Transfer of a 100 nm thick Cr test pattern with micrometer-scale features into the biopolymer is demonstrated. Replication and atomic force microscopy imaging of imprinted cellular surface features with sub-50 nm resolution is shown. The process has applications in disease diagnostics, in drug discovery, and for the creation of biomimetic cell culture scaffolds.