Prakash Adhikari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Prakash Adhikari has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Andrew J. Zele
Centre for Vision and Eye Research, Queensland University of Technology (QUT), Brisbane, Queensland, Australia
9 shared publications- Beatrix Feigl
Centre for Vision and Eye Research, Queensland University of Technology
8 shared publications Beatrix Feigl
Centre for Vision and Eye Research, Queensland University of Technology (QUT), Brisbane, Queensland, Australia
6 shared publications- Andrew J. Zele
Centre for Vision and Eye Research, Queensland University of Technology
5 shared publications Dingcai Cao
University of Illinois at Chicago
3 shared publications- Nabin Paudel
Retina International, Dublin, Ireland
3 shared publications
Latest Publications
- 26 March 2025
- Published by BMJ in British Journal of Ophthalmology
- Vol. 109 (9) , 1088-1090
Rapid clinical assessment of spatial contrast sensitivity changes in retinal disease and ageing
Evidence suggests best-corrected visual acuity is not sensitive to subtle vision losses in early disease stages, indicating the need for other tests. Here, we quantified contrast sensitivity in 99 people (20–88 years): 52 with eye diseases (10 with early AMD, 9 diabetics without retinopathy, 22 glaucoma suspects, 11 high myopes) and 47 age-matched healthy controls using a new spatial vision chart (0.28–100% Weber contrasts; 3–60 c/° frequencies). In retinal diseases and healthy ageing, the chart detected frequency-dependent losses; sensitivity was reduced at 3 and 8 c/° in AMD, at 6 and 8 c/° in diabetes, and at all frequencies in myopia and with ageing. Intrasession repeatability was excellent and spatial contrast changes were in accordance with deficits identified previously using complex and time-consuming psychophysical tests. The chart offers a simple, rapid and readily available tool for clinical use to document early visual deficits.
- 26 March 2025
- Published by BMJ in British Journal of Ophthalmology
- Vol. 109 (9) , 1088-1090
Rapid clinical assessment of spatial contrast sensitivity changes in retinal disease and ageing
Evidence suggests best-corrected visual acuity is not sensitive to subtle vision losses in early disease stages, indicating the need for other tests. Here, we quantified contrast sensitivity in 99 people (20–88 years): 52 with eye diseases (10 with early AMD, 9 diabetics without retinopathy, 22 glaucoma suspects, 11 high myopes) and 47 age-matched healthy controls using a new spatial vision chart (0.28–100% Weber contrasts; 3–60 c/° frequencies). In retinal diseases and healthy ageing, the chart detected frequency-dependent losses; sensitivity was reduced at 3 and 8 c/° in AMD, at 6 and 8 c/° in diabetes, and at all frequencies in myopia and with ageing. Intrasession repeatability was excellent and spatial contrast changes were in accordance with deficits identified previously using complex and time-consuming psychophysical tests. The chart offers a simple, rapid and readily available tool for clinical use to document early visual deficits.
- Open Access
- 29 May 2024
- Published by The Royal Society in Proceedings Of The Royal Society B-Biological Sciences
- Vol. 291 (2023) , 20232708
Melanopsin-mediated amplification of cone signals in the human visual cortex
The ambient daylight variation is coded by melanopsin photoreceptors and their luxotonic activity increases towards midday when colour temperatures are cooler, and irradiances are higher. Although melanopsin and cone photoresponses can be mediated via separate pathways, the connectivity of melanopsin cells across all levels of the retina enables them to modify cone signals. The downstream effects of melanopsin-cone interactions on human vision are however, incompletely understood. Here, we determined how the change in daytime melanopsin activation affects the human cone pathway signals in the visual cortex. A 5-primary silent-substitution method was developed to evaluate the dependence of cone-mediated signals on melanopsin activation by spectrally tuning the lights and stabilizing the rhodopsin activation under a constant cone photometric luminance. The retinal (white noise electroretinogram) and cortical responses (visual evoked potential) were simultaneously recorded with the photoreceptor-directed lights in 10 observers. By increasing the melanopsin activation, a reverse response pattern was observed with cone signals being supressed in the retina by 27% ( p = 0.03) and subsequently amplified by 16% ( p = 0.01) as they reach the cortex. We infer that melanopsin activity can amplify cone signals at sites distal to retinal bipolar cells to cause a decrease in the psychophysical Weber fraction for cone vision.
- 29 May 2024
- Published by The Royal Society in Proceedings Of The Royal Society B-Biological Sciences
- Vol. 291 (2023) , 20232708
Open AccessMelanopsin-mediated amplification of cone signals in the human visual cortex
The ambient daylight variation is coded by melanopsin photoreceptors and their luxotonic activity increases towards midday when colour temperatures are cooler, and irradiances are higher. Although melanopsin and cone photoresponses can be mediated via separate pathways, the connectivity of melanopsin cells across all levels of the retina enables them to modify cone signals. The downstream effects of melanopsin-cone interactions on human vision are however, incompletely understood. Here, we determined how the change in daytime melanopsin activation affects the human cone pathway signals in the visual cortex. A 5-primary silent-substitution method was developed to evaluate the dependence of cone-mediated signals on melanopsin activation by spectrally tuning the lights and stabilizing the rhodopsin activation under a constant cone photometric luminance. The retinal (white noise electroretinogram) and cortical responses (visual evoked potential) were simultaneously recorded with the photoreceptor-directed lights in 10 observers. By increasing the melanopsin activation, a reverse response pattern was observed with cone signals being supressed in the retina by 27% ( p = 0.03) and subsequently amplified by 16% ( p = 0.01) as they reach the cortex. We infer that melanopsin activity can amplify cone signals at sites distal to retinal bipolar cells to cause a decrease in the psychophysical Weber fraction for cone vision.
- 6 January 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (2) , 287-289
Design and validation of a chart‐based measure of the limits of spatial contrast sensitivity
- 6 January 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (2) , 287-289
Design and validation of a chart‐based measure of the limits of spatial contrast sensitivity
- Open Access
- 7 April 2022
- Published by Wiley in European Journal of Neuroscience
- Vol. 55 (8) , 1986-2002
The role of melanopsin photoreception on visual attention linked pupil responses
A decision during a visual task is marked by a task‐evoked pupil dilation (TEPD) that is linked to the global cortical arousal state. Melanopsin expressing intrinsically photosensitive retinal ganglion cells (ipRGCs) form the afferent pathway for this pupil response. Melanopsin activation also influences mood and arousal and increases activity in decision‐making brain areas that receive direct ipRGC projections. Here, an optical photostimulation method controlled the excitations of all five photoreceptor classes in the human eye to isolate melanopsin‐mediated photoreception. We hypothesised that the TEPD can be driven by directing active visual covert attention through the ipRGC pathway. When observers are completely certain of the stimulus presence, melanopsin‐directed stimulation produces a TEPD of similar amplitude to a cone‐directed stimulation, with their combination producing larger amplitudes. This dilation is satisfactorily modelled by linear addition with a higher melanopsin weighting in ipRGCs. Visual reaction times were longest in response to melanopsin‐directed lights. Next, we asked whether the afferent photoreceptor input and decision certainty, controlled by priming the observer's a priori expectation, interact to drive the TEPD. Signal detection analysis showed that by fixing the predecision certainty (bias), the phasic arousal and TEPD amplitude vary with observer criterion (c′) and sensitivity (d′) but not with preferential activation of melanopsin. The signature feature of the melanopsin response during attention was a biphasic TEPD. We conclude that active covert attention can be modulated by visual information mediated via ipRGCs, but that phasic arousal responses marked using the TEPD are not increased by higher levels of melanopsin activation.
- 7 April 2022
- Published by Wiley in European Journal of Neuroscience
- Vol. 55 (8) , 1986-2002
Open AccessThe role of melanopsin photoreception on visual attention linked pupil responses
A decision during a visual task is marked by a task‐evoked pupil dilation (TEPD) that is linked to the global cortical arousal state. Melanopsin expressing intrinsically photosensitive retinal ganglion cells (ipRGCs) form the afferent pathway for this pupil response. Melanopsin activation also influences mood and arousal and increases activity in decision‐making brain areas that receive direct ipRGC projections. Here, an optical photostimulation method controlled the excitations of all five photoreceptor classes in the human eye to isolate melanopsin‐mediated photoreception. We hypothesised that the TEPD can be driven by directing active visual covert attention through the ipRGC pathway. When observers are completely certain of the stimulus presence, melanopsin‐directed stimulation produces a TEPD of similar amplitude to a cone‐directed stimulation, with their combination producing larger amplitudes. This dilation is satisfactorily modelled by linear addition with a higher melanopsin weighting in ipRGCs. Visual reaction times were longest in response to melanopsin‐directed lights. Next, we asked whether the afferent photoreceptor input and decision certainty, controlled by priming the observer's a priori expectation, interact to drive the TEPD. Signal detection analysis showed that by fixing the predecision certainty (bias), the phasic arousal and TEPD amplitude vary with observer criterion (c′) and sensitivity (d′) but not with preferential activation of melanopsin. The signature feature of the melanopsin response during attention was a biphasic TEPD. We conclude that active covert attention can be modulated by visual information mediated via ipRGCs, but that phasic arousal responses marked using the TEPD are not increased by higher levels of melanopsin activation.
- 9 November 2021
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 42 (1) , 110-122
Design and validation of a chart‐based measure of the limits of spatial contrast sensitivity
Purpose: Current chart‐based tests of spatial contrast sensitivity (SCS) with fixed or narrow frequency ranges (≤18 cycles/°) cannot characterise the limits of spatial contrast vision. Here we present the design and validation of a chart‐based measure of the spatial contrast envelope. Methods: Following the principles of the standard visual acuity (Bailey‐Lovie) and contrast sensitivity (Pelli‐Robson) charts, a combined spatial‐contrast and visual acuity chart was designed using a language‐independent triangular symbol for a four‐alternative forced‐choice procedure plus chart rotation. Symbol frequencies ranged between 0.38 and 60 cycles/° spaced along 10 radial axes (0.55%–100% contrast). The chart was validated with reference to the Bailey‐Lovie and Pelli‐Robson charts; its reliability and sensitivity to changes in illumination, simulated cataract and blur was evaluated in healthy adults. Results: The photopic SCS function could be measured in 5.5 ± 0.5 min; thresholding around the spatial contrast resolution limit reduced completion times to ~2 min. There was good agreement with high‐contrast visual acuity (difference = 0.08 ± 0.02 logMAR) and contrast‐sensitivity at 1.5 cycles/° (0.13 ± 0.06 logCS). Test‐retest reliability was excellent at all spatial frequencies (ICC = 0.99). Mesopic illumination or simulated cataract caused a generalised SCS loss; myopic blur reduced high‐frequency sensitivity. Spatial contrast sensitivity was independent of radial axis orientation (cardinal or oblique). Conclusions: The chart provides a time‐efficient, reliable and inexpensive measure of SCS with applications in research and clinic for detecting subtle deficits in early stages of ocular and neurological conditions that often manifest at higher frequencies. It is sensitive to vision changes occurring in dim lighting and with simulated cataract and blur. The chart is available open‐access for self‐printing; contrast variation in print can be controlled through user calibration and/or establishing normative SCS functions using the theoretical values.
- 9 November 2021
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 42 (1) , 110-122
Design and validation of a chart‐based measure of the limits of spatial contrast sensitivity
Purpose: Current chart‐based tests of spatial contrast sensitivity (SCS) with fixed or narrow frequency ranges (≤18 cycles/°) cannot characterise the limits of spatial contrast vision. Here we present the design and validation of a chart‐based measure of the spatial contrast envelope. Methods: Following the principles of the standard visual acuity (Bailey‐Lovie) and contrast sensitivity (Pelli‐Robson) charts, a combined spatial‐contrast and visual acuity chart was designed using a language‐independent triangular symbol for a four‐alternative forced‐choice procedure plus chart rotation. Symbol frequencies ranged between 0.38 and 60 cycles/° spaced along 10 radial axes (0.55%–100% contrast). The chart was validated with reference to the Bailey‐Lovie and Pelli‐Robson charts; its reliability and sensitivity to changes in illumination, simulated cataract and blur was evaluated in healthy adults. Results: The photopic SCS function could be measured in 5.5 ± 0.5 min; thresholding around the spatial contrast resolution limit reduced completion times to ~2 min. There was good agreement with high‐contrast visual acuity (difference = 0.08 ± 0.02 logMAR) and contrast‐sensitivity at 1.5 cycles/° (0.13 ± 0.06 logCS). Test‐retest reliability was excellent at all spatial frequencies (ICC = 0.99). Mesopic illumination or simulated cataract caused a generalised SCS loss; myopic blur reduced high‐frequency sensitivity. Spatial contrast sensitivity was independent of radial axis orientation (cardinal or oblique). Conclusions: The chart provides a time‐efficient, reliable and inexpensive measure of SCS with applications in research and clinic for detecting subtle deficits in early stages of ocular and neurological conditions that often manifest at higher frequencies. It is sensitive to vision changes occurring in dim lighting and with simulated cataract and blur. The chart is available open‐access for self‐printing; contrast variation in print can be controlled through user calibration and/or establishing normative SCS functions using the theoretical values.
- 1 November 2021
- Published by Elsevier in Vision Research
- Vol. 188, 126-138
Light adaptation characteristics of melanopsin
- 1 November 2021
- Published by Elsevier in Vision Research
- Vol. 188, 126-138
Light adaptation characteristics of melanopsin
- 25 June 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 38 (7) , 1051-1064
Optimizing methods to isolate melanopsin-directed responses
The intrinsic melanopsin photoresponse may initiate visual signals that differ in spatiotemporal characteristics from the cone-opsin- and rhodopsin-mediated signals. Applying the CIE standard observer functions in silent-substitution methods can require individual differences in photoreceptor spectral sensitivities and pre-receptoral filtering to be corrected; failure to do so can lead to the intrusion of more sensitive cone processes with putative melanopsin-directed stimuli. Here we evaluate heterochromatic flicker photometry (HFP) and photoreceptor-directed temporal white noise as techniques to limit the effect of these individual differences. Individualized luminous efficiency functions () were compared to the CIE standard observer functions. We show that adapting chromaticities used in silent-substitution methods can deviate by up to 54% in luminance when estimated with the individual and standard observer functions. These deviations lead to inadvertent cone intrusions in the visual functions measured with melanopsin-directed stimuli. To eliminate the intrusions, individual HFP corrections are sufficient at low frequencies () but temporal white noise is also required at higher frequencies to desensitize penumbral cones. We therefore recommend the selective application of individualized observer calibration and/or temporal white noise in silent-substitution paradigms when studying melanopsin-directed photoresponses.- 25 June 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 38 (7) , 1051-1064
Optimizing methods to isolate melanopsin-directed responses
The intrinsic melanopsin photoresponse may initiate visual signals that differ in spatiotemporal characteristics from the cone-opsin- and rhodopsin-mediated signals. Applying the CIE standard observer functions in silent-substitution methods can require individual differences in photoreceptor spectral sensitivities and pre-receptoral filtering to be corrected; failure to do so can lead to the intrusion of more sensitive cone processes with putative melanopsin-directed stimuli. Here we evaluate heterochromatic flicker photometry (HFP) and photoreceptor-directed temporal white noise as techniques to limit the effect of these individual differences. Individualized luminous efficiency functions () were compared to the CIE standard observer functions. We show that adapting chromaticities used in silent-substitution methods can deviate by up to 54% in luminance when estimated with the individual and standard observer functions. These deviations lead to inadvertent cone intrusions in the visual functions measured with melanopsin-directed stimuli. To eliminate the intrusions, individual HFP corrections are sufficient at low frequencies () but temporal white noise is also required at higher frequencies to desensitize penumbral cones. We therefore recommend the selective application of individualized observer calibration and/or temporal white noise in silent-substitution paradigms when studying melanopsin-directed photoresponses.- 1 March 2021
- Published by Elsevier in Vision Research
- Vol. 180, 1-10
Threshold vision under full-field stimulation: Revisiting the minimum number of quanta necessary to evoke a visual sensation
- 1 March 2021
- Published by Elsevier in Vision Research
- Vol. 180, 1-10
Threshold vision under full-field stimulation: Revisiting the minimum number of quanta necessary to evoke a visual sensation
- 12 March 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (4) , A145-A153
Rhodopsin and melanopsin contributions to human brightness estimation
We examined the contributions of rhodopsin and melanopsin to human brightness estimation under dim lighting. Absolute brightness magnitudes were estimated for full-field, rhodopsin-, or melanopsin-equated narrowband lights ( λ m a x : 462 , 499, 525 nm). Our data show that in scotopic illumination ( − 5.1 to − 3.9 log µ W a t t s ⋅ c m − 2 ), the perceptual brightness estimates of rhodopic irradiance-equated conditions are independent of their corresponding melanopic irradiance, whereas brightness estimates with melanopic irradiance-equated conditions increase with increasing rhodopic irradiance. In mesopic illumination ( − 3.4 to − 1.9 log µ W a t t s ⋅ c m − 2 ), the brightness estimates with both lighting conditions increase with increasing rhodopic or melanopic irradiances. Rhodopsin activation therefore entirely signals scotopic brightness perception and plateaus in mesopic illumination where intrinsic melanopsin contributions become first evident. We infer that all photoreceptor signals are transmitted to higher visual centers for representing scene brightness in scotopic and mesopic illumination through both conventional and melanopsin ganglion cell pathways.
- 12 March 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (4) , A145-A153
Rhodopsin and melanopsin contributions to human brightness estimation
We examined the contributions of rhodopsin and melanopsin to human brightness estimation under dim lighting. Absolute brightness magnitudes were estimated for full-field, rhodopsin-, or melanopsin-equated narrowband lights ( λ m a x : 462 , 499, 525 nm). Our data show that in scotopic illumination ( − 5.1 to − 3.9 log µ W a t t s ⋅ c m − 2 ), the perceptual brightness estimates of rhodopic irradiance-equated conditions are independent of their corresponding melanopic irradiance, whereas brightness estimates with melanopic irradiance-equated conditions increase with increasing rhodopic irradiance. In mesopic illumination ( − 3.4 to − 1.9 log µ W a t t s ⋅ c m − 2 ), the brightness estimates with both lighting conditions increase with increasing rhodopic or melanopic irradiances. Rhodopsin activation therefore entirely signals scotopic brightness perception and plateaus in mesopic illumination where intrinsic melanopsin contributions become first evident. We infer that all photoreceptor signals are transmitted to higher visual centers for representing scene brightness in scotopic and mesopic illumination through both conventional and melanopsin ganglion cell pathways.
- 20 December 2019
- Published by Wiley in Journal of Sleep Research
- Vol. 29 (5) , e12963
The accuracy of artificial and natural light measurements by actigraphs
Actigraphs are the reference standard for measuring light exposure in human non‐laboratory experiments due to their portability and long battery lives. However, actigraphs typically have a limited illuminance operating range not representative of real‐world conditions, and for many actigraphs, the accuracy of their light measurement has not been verified independently. We assessed the illuminances recorded by Activinsights GENEActiv Original and Philips Actiwatch 2 actigraphs in comparison to a calibrated, laboratory‐standard photometer, under both artificial light‐emitting diode (LED) and natural sunlight illuminations that might be encountered by a person under real‐world conditions. We show that in response to ~20,000 lux white LED light, the GENEActiv and Actiwatch 2 underestimate illuminance by recording 50% and 25% of the true value, respectively. Under ~30,000 lux sunlight, the GENEActiv readily saturates whereas the Actiwatch 2 reports ~46% of the true illuminance. These underestimations are highly linear and we provide correction factors to estimate the illuminance levels of the ambient environment measured by the actigraphs. We also evaluate the application of neutral density filters for extending the operating range of both devices in natural sunlight illuminations (as high as 30,000 lux during our measurements) and demonstrate that this may be a viable approach for increasing the operating range of the Actiwatch 2 but not the GENEActiv. We conclude that both actigraphs provide good performance in monitoring the temporal patterning of light, whereas the absolute illuminance values require correction to accurately evaluate the effects of light intensity on human health and behaviours.
- 20 December 2019
- Published by Wiley in Journal of Sleep Research
- Vol. 29 (5) , e12963
The accuracy of artificial and natural light measurements by actigraphs
Actigraphs are the reference standard for measuring light exposure in human non‐laboratory experiments due to their portability and long battery lives. However, actigraphs typically have a limited illuminance operating range not representative of real‐world conditions, and for many actigraphs, the accuracy of their light measurement has not been verified independently. We assessed the illuminances recorded by Activinsights GENEActiv Original and Philips Actiwatch 2 actigraphs in comparison to a calibrated, laboratory‐standard photometer, under both artificial light‐emitting diode (LED) and natural sunlight illuminations that might be encountered by a person under real‐world conditions. We show that in response to ~20,000 lux white LED light, the GENEActiv and Actiwatch 2 underestimate illuminance by recording 50% and 25% of the true value, respectively. Under ~30,000 lux sunlight, the GENEActiv readily saturates whereas the Actiwatch 2 reports ~46% of the true illuminance. These underestimations are highly linear and we provide correction factors to estimate the illuminance levels of the ambient environment measured by the actigraphs. We also evaluate the application of neutral density filters for extending the operating range of both devices in natural sunlight illuminations (as high as 30,000 lux during our measurements) and demonstrate that this may be a viable approach for increasing the operating range of the Actiwatch 2 but not the GENEActiv. We conclude that both actigraphs provide good performance in monitoring the temporal patterning of light, whereas the absolute illuminance values require correction to accurately evaluate the effects of light intensity on human health and behaviours.