Steven Wright
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Steven Wright has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Richard R. A. Syms
EEE Department, Imperial College London, Exhibition Road, SW7 2AZ London, United Kingdom
6 shared publications - Eckart Hasselbrink
Fakultät für Chemie and Center for Nanointegration (CENIDE), Universität Duisburg-Essen , D-45117 Essen
4 shared publications Alan Morris
Chemistry Department, University of Southampton, Southampton, SO17 1BJ, United Kingdom
3 shared publicationsAndrew Malcolm
†Microsaic Systems plc, Woking, Surrey GU21 5BX, U.K.
3 shared publicationsMichael C. Flowers
Chemistry Department, University of Southampton, Southampton, SO17 1BJ, United Kingdom
3 shared publicationsNeil Dash
†Microsaic Systems plc, Woking, Surrey GU21 5BX, U.K.
3 shared publications
Latest Publications
- Open Access
- 23 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (17) , 12883-12894
Chromatography-Free Analysis of Mixtures Using a Two-Dimensional Mass Spectrometry (2DMS)-Enabled Quadrupole Time-of-Flight (QToF) Analyzer
Two-dimensional mass spectrometry (2DMS) is a powerful data-independent analysis (DIA) technique that allows mixtures to be analyzed without chromatographic separation of the components. Until now, high-resolution 2DMS has only been possible using Fourier Transform Ion Cyclotron Resonance (FTICR) instruments, which are impractical for most laboratories. Herein, we present the first experimental demonstration of 2DMS using a quadrupole time-of-flight (QToF) mass spectrometer. These instruments are commonplace, but offer high resolution and the ability to assign peaks in the 2D spectrum based on accurate mass. The key development is the application of stored waveform ion radius modulation (SWIM) to ions trapped in the quadrupole prior to mass analysis by the ToF analyzer. SWIM is an encoding technique that uses broadband dipolar excitation and a radius-dependent fragmentation method to modulate precursor and product ion signals. We show how each component of a peptide mixture can be individually, yet simultaneously, sequenced using collision-induced dissociation (CID) and/or ultraviolet photodissociation (UVPD).
- 23 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (17) , 12883-12894
Open AccessChromatography-Free Analysis of Mixtures Using a Two-Dimensional Mass Spectrometry (2DMS)-Enabled Quadrupole Time-of-Flight (QToF) Analyzer
Two-dimensional mass spectrometry (2DMS) is a powerful data-independent analysis (DIA) technique that allows mixtures to be analyzed without chromatographic separation of the components. Until now, high-resolution 2DMS has only been possible using Fourier Transform Ion Cyclotron Resonance (FTICR) instruments, which are impractical for most laboratories. Herein, we present the first experimental demonstration of 2DMS using a quadrupole time-of-flight (QToF) mass spectrometer. These instruments are commonplace, but offer high resolution and the ability to assign peaks in the 2D spectrum based on accurate mass. The key development is the application of stored waveform ion radius modulation (SWIM) to ions trapped in the quadrupole prior to mass analysis by the ToF analyzer. SWIM is an encoding technique that uses broadband dipolar excitation and a radius-dependent fragmentation method to modulate precursor and product ion signals. We show how each component of a peptide mixture can be individually, yet simultaneously, sequenced using collision-induced dissociation (CID) and/or ultraviolet photodissociation (UVPD).
- Open Access
- 1 July 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (4) , 044103
Solvent-pumped evaporation concentration on paper in linear and radial geometries
Solvent-pumped evaporation-driven concentration of an initial distribution of solutes on a porous substrate is considered in one and two dimensions. Approximate analytic solutions to the isotropic advection–dispersion equations are first found for a Gaussian kernel and an infinite domain, following the smoothed particle approximation. Analytic solutions for more general initial distributions are then found as sums of Gaussians, and comparison is made with numerical solutions. In each case, initial distributions are advected toward the stagnation point and concentrated. Two-dimensional analysis is then extended to describe anisotropy in permeability and diffusion, and hydrodynamic dispersion. Radial-flow experiments are performed using filter papers and water-soluble dyes. Diffusion coefficients, temperature and humidity profiles, and the evolution of spot distributions are measured. The results confirm minor anisotropy in permeability and diffusion, limited hydrodynamic dispersion, and largely uniform evaporation. Péclet numbers over 2500 are demonstrated. Evaporation-driven concentration provides a mechanism for solute transport over long timescales. Potential applications lie in the design of paper spray microanalytical devices operating by solvent pumping rather than capillary flow.
- 1 July 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (4) , 044103
Open AccessSolvent-pumped evaporation concentration on paper in linear and radial geometries
Solvent-pumped evaporation-driven concentration of an initial distribution of solutes on a porous substrate is considered in one and two dimensions. Approximate analytic solutions to the isotropic advection–dispersion equations are first found for a Gaussian kernel and an infinite domain, following the smoothed particle approximation. Analytic solutions for more general initial distributions are then found as sums of Gaussians, and comparison is made with numerical solutions. In each case, initial distributions are advected toward the stagnation point and concentrated. Two-dimensional analysis is then extended to describe anisotropy in permeability and diffusion, and hydrodynamic dispersion. Radial-flow experiments are performed using filter papers and water-soluble dyes. Diffusion coefficients, temperature and humidity profiles, and the evolution of spot distributions are measured. The results confirm minor anisotropy in permeability and diffusion, limited hydrodynamic dispersion, and largely uniform evaporation. Péclet numbers over 2500 are demonstrated. Evaporation-driven concentration provides a mechanism for solute transport over long timescales. Potential applications lie in the design of paper spray microanalytical devices operating by solvent pumping rather than capillary flow.
- Open Access
- 1 January 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (1) , 014102
Paper-based evaporation concentrators: Comparison of linear and radial geometries
Paper-based evaporation concentrators with linear and radial geometries are compared. A new method of finding approximate analytic solutions of the advection–dispersion equation is proposed, based on the behavior of concentrators with infinite sources. Analytic approximations are compared with numerical solutions, and the advantage of radial concentration is highlighted: linear concentration rates scale with the square root of the Péclet number Pe while radial rates scale with Pe itself, leading to faster radial concentration beyond a critical value. Experiments are performed with Brilliant Blue FCF dye, using optical transmission and the Beer–Lambert law for quantitation. Dye concentrations are chosen for operation in the linear absorbance regime. Radial concentration is demonstrated under ambient conditions on filter paper disks with 60 mm diameter evaporation areas fed from a perimeter source, in a reverse of the well-known “coffee stain” experiment. Airflow enhanced concentration in strips and wedges is compared directly, using laser-patterned chromatography paper. The advantage of radial concentration is confirmed (and enhanced by diversion of concentrate to the corners of strips) and concentration factors greater than (the dynamic range of measurement) are obtained in ∼2 h using 30 mm long columns.- 1 January 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (1) , 014102
Open AccessPaper-based evaporation concentrators: Comparison of linear and radial geometries
Paper-based evaporation concentrators with linear and radial geometries are compared. A new method of finding approximate analytic solutions of the advection–dispersion equation is proposed, based on the behavior of concentrators with infinite sources. Analytic approximations are compared with numerical solutions, and the advantage of radial concentration is highlighted: linear concentration rates scale with the square root of the Péclet number Pe while radial rates scale with Pe itself, leading to faster radial concentration beyond a critical value. Experiments are performed with Brilliant Blue FCF dye, using optical transmission and the Beer–Lambert law for quantitation. Dye concentrations are chosen for operation in the linear absorbance regime. Radial concentration is demonstrated under ambient conditions on filter paper disks with 60 mm diameter evaporation areas fed from a perimeter source, in a reverse of the well-known “coffee stain” experiment. Airflow enhanced concentration in strips and wedges is compared directly, using laser-patterned chromatography paper. The advantage of radial concentration is confirmed (and enhanced by diversion of concentrate to the corners of strips) and concentration factors greater than (the dynamic range of measurement) are obtained in ∼2 h using 30 mm long columns. - Open Access
- 19 February 2021
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 31 (4) , 045010
Shock-free ion transmission in a skimmer-based MEMS mass spectrometer vacuum interface
Shock-free ion transmission from atmospheric pressure to a microelectromechanical system (MEMS)-based mass spectrometer has been achieved using micro-engineered nickel skimmers. The signal level has increased 70-fold compared with a previous configuration in which the skimmer did not sample the supersonic flow. The skimmers are formed by electroplating internal surfaces of anisotropically etched, pyramidal holes in (100) silicon. Etching from the reverse of the wafer exposes free-standing, open-ended skimmers supported by remaining silicon. High-resolution schlieren imaging has been used to visualise gas flow within the interface. Signal enhancement and increased gas throughput are observed when the skimmer attaches to the supersonic gas expansion via oblique shocks. The silicon back wall interacts with the flow field, causing the free jet Mach disc to evolve into a bowl-shaped surface shock whose position asymptotically approaches a stand-off separation as the interface pressure decreases. Ideally, the skimmer entrance should be located approximately midway between the inlet and the back wall. This development should allow a sensitivity increase in MEMS mass spectrometers using pumps of moderate capacity.
- 19 February 2021
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 31 (4) , 045010
Open AccessShock-free ion transmission in a skimmer-based MEMS mass spectrometer vacuum interface
Shock-free ion transmission from atmospheric pressure to a microelectromechanical system (MEMS)-based mass spectrometer has been achieved using micro-engineered nickel skimmers. The signal level has increased 70-fold compared with a previous configuration in which the skimmer did not sample the supersonic flow. The skimmers are formed by electroplating internal surfaces of anisotropically etched, pyramidal holes in (100) silicon. Etching from the reverse of the wafer exposes free-standing, open-ended skimmers supported by remaining silicon. High-resolution schlieren imaging has been used to visualise gas flow within the interface. Signal enhancement and increased gas throughput are observed when the skimmer attaches to the supersonic gas expansion via oblique shocks. The silicon back wall interacts with the flow field, causing the free jet Mach disc to evolve into a bowl-shaped surface shock whose position asymptotically approaches a stand-off separation as the interface pressure decreases. Ideally, the skimmer entrance should be located approximately midway between the inlet and the back wall. This development should allow a sensitivity increase in MEMS mass spectrometers using pumps of moderate capacity.
- 15 May 2018
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 28 (8) , 085017
Supersonic jet interactions with a micro-engineered skimmer
A micro-engineered, skimmer-based vacuum interface has been demonstrated and used to investigate gas dynamics on a sub-millimeter length scale. The interface is fabricated as a stacked assembly of silicon dies, based on an anisotropically etched inlet orifice and a pyramidal skimmer cone formed in electroplated nickel. Expansion of gas into vacuum, interaction of a supersonic jet with the skimmer and transmission of a collimated beam into a second vacuum stage have all been imaged with a schlieren microscope. Using a glass-walled vacuum chamber, flow patterns upstream and fully downstream of the skimmer have been imaged together for the first time. At low first-stage pressures, the 150–200 µ m tall skimmers cannot fully penetrate the shock arising from interaction of the jet with the back wall. However, as the pressure is increased, a multiple shock cell structure evolves, the jet narrows and transmission rises sharply. Eventually, a collimated beam is transmitted to the second stage. When the skimmer aperture is smaller than the source aperture, a series of distinct peaks is evident in a plot of transmission against first-stage pressure. Imaging shows that at each successive peak, the number of shock cells increases by one and the skimmer inlet is coincident with a node.
- 15 May 2018
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 28 (8) , 085017
Supersonic jet interactions with a micro-engineered skimmer
A micro-engineered, skimmer-based vacuum interface has been demonstrated and used to investigate gas dynamics on a sub-millimeter length scale. The interface is fabricated as a stacked assembly of silicon dies, based on an anisotropically etched inlet orifice and a pyramidal skimmer cone formed in electroplated nickel. Expansion of gas into vacuum, interaction of a supersonic jet with the skimmer and transmission of a collimated beam into a second vacuum stage have all been imaged with a schlieren microscope. Using a glass-walled vacuum chamber, flow patterns upstream and fully downstream of the skimmer have been imaged together for the first time. At low first-stage pressures, the 150–200 µ m tall skimmers cannot fully penetrate the shock arising from interaction of the jet with the back wall. However, as the pressure is increased, a multiple shock cell structure evolves, the jet narrows and transmission rises sharply. Eventually, a collimated beam is transmitted to the second stage. When the skimmer aperture is smaller than the source aperture, a series of distinct peaks is evident in a plot of transmission against first-stage pressure. Imaging shows that at each successive peak, the number of shock cells increases by one and the skimmer inlet is coincident with a node.
- 8 January 2016
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 26 (2) , 023001
MEMS mass spectrometers: the next wave of miniaturization
This paper reviews mass spectrometers based on micro-electro-mechanical systems (MEMS) technology. The MEMS approach to integration is first briefly described, and the difficulties of miniaturizing mass spectrometers are outlined. MEMS components for ionization and mass filtering are then reviewed, together with additional components for ion detection, vacuum pressure measurement and pumping. Mass spectrometer systems containing MEMS sub-components are then described, applications for miniaturized and portable systems are discussed, and challenges and opportunities are presented.
- 8 January 2016
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 26 (2) , 023001
MEMS mass spectrometers: the next wave of miniaturization
This paper reviews mass spectrometers based on micro-electro-mechanical systems (MEMS) technology. The MEMS approach to integration is first briefly described, and the difficulties of miniaturizing mass spectrometers are outlined. MEMS components for ionization and mass filtering are then reviewed, together with additional components for ion detection, vacuum pressure measurement and pumping. Mass spectrometer systems containing MEMS sub-components are then described, applications for miniaturized and portable systems are discussed, and challenges and opportunities are presented.
- Open Access
- 23 February 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (6) , 3115-3122
A Microelectromechanical Systems-Enabled, Miniature Triple Quadrupole Mass Spectrometer
Miniaturized mass spectrometers are becoming increasingly capable, enabling the development of many novel field and laboratory applications. However, to date, triple quadrupole tandem mass spectrometers, the workhorses of quantitative analysis, have not been significantly reduced in size. Here, the basis of a field-deployable triple quadrupole is described. The key development is a highly miniaturized ion optical assembly in which a sequence of six microengineered components is employed to generate ions at atmospheric pressure, provide a vacuum interface, effect ion guiding, and perform fragmentation and mass analysis. Despite its small dimensions, the collision cell efficiently fragments precursor ions and yields product ion spectra that are very similar to those recorded using conventional instruments. The miniature triple quadrupole has been used to detect thiabendazole, a common pesticide, in apples at a level of 10 ng/g.
- 23 February 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (6) , 3115-3122
Open AccessA Microelectromechanical Systems-Enabled, Miniature Triple Quadrupole Mass Spectrometer
Miniaturized mass spectrometers are becoming increasingly capable, enabling the development of many novel field and laboratory applications. However, to date, triple quadrupole tandem mass spectrometers, the workhorses of quantitative analysis, have not been significantly reduced in size. Here, the basis of a field-deployable triple quadrupole is described. The key development is a highly miniaturized ion optical assembly in which a sequence of six microengineered components is employed to generate ions at atmospheric pressure, provide a vacuum interface, effect ion guiding, and perform fragmentation and mass analysis. Despite its small dimensions, the collision cell efficiently fragments precursor ions and yields product ion spectra that are very similar to those recorded using conventional instruments. The miniature triple quadrupole has been used to detect thiabendazole, a common pesticide, in apples at a level of 10 ng/g.
- 17 July 2012
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 26 (17) , 1999-2010
Continuous flow reaction monitoring using an on‐line miniature mass spectrometer
RATIONALE: A recently developed miniature electrospray ionisation mass spectrometer has been coupled to a preparative flow chemistry system in order to monitor reactive intermediates and competing reaction paths, screen starting materials, and optimise reaction conditions. Although ideally suited to the application, mass spectrometers have rarely been used in this way, as traditional instruments are too bulky to be conveniently coupled to flow chemistry platforms. METHODS: A six‐port switching valve fitted with a 5 μL loop was used to periodically sample the flow stream leaving the reactor coil. Mass spectra corresponding to the sample loop contents were observed approximately 10 s after activating the valve. High fluidic pressure was maintained throughout to ensure that gaseous products remained in solution. As an illustrative example of how this apparatus can be employed, the generation of benzyne and its subsequent reaction with furan were investigated. Benzyne was prepared via diazotisation of anthranilic acid using tert ‐butyl nitrite. RESULTS: Unexpectedly, the explosive diazotised intermediate was detected by the mass spectrometer at low coil temperatures or short residence times. The optimum reactor temperature and residence time for production of the desired Diels‐Alder product are 50 °C and 3–5 min, respectively. There are competing reaction pathways leading to the formation of acridone and several other by‐products. CONCLUSIONS: On‐line mass spectrometry allowed the flow conditions to be quickly tuned for safe operation and optimal generation of the desired product. The validity of this approach was corroborated by off‐line liquid chromatography/mass spectrometry (LC/MS) analysis of flow samples. Copyright © 2012 John Wiley & Sons, Ltd.
- 17 July 2012
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 26 (17) , 1999-2010
Continuous flow reaction monitoring using an on‐line miniature mass spectrometer
RATIONALE: A recently developed miniature electrospray ionisation mass spectrometer has been coupled to a preparative flow chemistry system in order to monitor reactive intermediates and competing reaction paths, screen starting materials, and optimise reaction conditions. Although ideally suited to the application, mass spectrometers have rarely been used in this way, as traditional instruments are too bulky to be conveniently coupled to flow chemistry platforms. METHODS: A six‐port switching valve fitted with a 5 μL loop was used to periodically sample the flow stream leaving the reactor coil. Mass spectra corresponding to the sample loop contents were observed approximately 10 s after activating the valve. High fluidic pressure was maintained throughout to ensure that gaseous products remained in solution. As an illustrative example of how this apparatus can be employed, the generation of benzyne and its subsequent reaction with furan were investigated. Benzyne was prepared via diazotisation of anthranilic acid using tert ‐butyl nitrite. RESULTS: Unexpectedly, the explosive diazotised intermediate was detected by the mass spectrometer at low coil temperatures or short residence times. The optimum reactor temperature and residence time for production of the desired Diels‐Alder product are 50 °C and 3–5 min, respectively. There are competing reaction pathways leading to the formation of acridone and several other by‐products. CONCLUSIONS: On‐line mass spectrometry allowed the flow conditions to be quickly tuned for safe operation and optimal generation of the desired product. The validity of this approach was corroborated by off‐line liquid chromatography/mass spectrometry (LC/MS) analysis of flow samples. Copyright © 2012 John Wiley & Sons, Ltd.
- 3 October 2011
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 25 (21) , 3281-3288
A miniature mass spectrometer for liquid chromatography applications
A miniature mass spectrometer capable of detecting analytes eluting from a high‐performance liquid chromatography (HPLC) system is described and demonstrated for the first time. The entire instrument, including all pumps and the computer, is contained within a single enclosure that may be conveniently accommodated at the base of the HPLC stack. The microspray ion source, vacuum interface, ion guide, and quadrupole ion filter are all microengineered. These components are fabricated in batches using microelectromechanical systems (MEMS) techniques and considered to be consumables. When coupled to a standard HPLC system using an integrated passive split, the limit of detection for reserpine while scanning the full mass range is 5 ng on‐column (1 pg of which is passed to the microspray). The mass range is m/z 100–800, and each spectrum is typically acquired at a rate of 1 scan per second. Copyright © 2011 John Wiley & Sons, Ltd.
- 3 October 2011
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 25 (21) , 3281-3288
A miniature mass spectrometer for liquid chromatography applications
A miniature mass spectrometer capable of detecting analytes eluting from a high‐performance liquid chromatography (HPLC) system is described and demonstrated for the first time. The entire instrument, including all pumps and the computer, is contained within a single enclosure that may be conveniently accommodated at the base of the HPLC stack. The microspray ion source, vacuum interface, ion guide, and quadrupole ion filter are all microengineered. These components are fabricated in batches using microelectromechanical systems (MEMS) techniques and considered to be consumables. When coupled to a standard HPLC system using an integrated passive split, the limit of detection for reserpine while scanning the full mass range is 5 ng on‐column (1 pg of which is passed to the microspray). The mass range is m/z 100–800, and each spectrum is typically acquired at a rate of 1 scan per second. Copyright © 2011 John Wiley & Sons, Ltd.
- 28 January 2010
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (5) , 1751-1758
Miniature Mass Spectrometer Systems Based on a Microengineered Quadrupole Filter
Two miniature mass spectrometer systems based on a microengineered quadrupole mass filter have been developed. One of the instruments has a footprint of 27 cm × 20 cm and is intended for laboratory use when space is at a premium. The other is portable and intended for use in the field. It is battery powered, weighs 14.9 kg, and is housed in a rugged case. This is the first example of a portable mass spectrometer incorporating an analyzer fabricated using microelectromechanical systems (MEMS) techniques. The starting material for construction of the filters is a bonded silicon on insulator substrate, which is selectively etched using batch processing techniques to form coupling optics and springs that accurately hold 0.5 mm diameter stainless steel rods in the required geometry. Assembled filters measure 35 mm × 6 mm × 1.5 mm and are mounted, together with an ion source and channeltron detector, in small, interchangeable cartridges, which plug into a 220 cm3 vacuum chamber. Recovery from accidental contamination or when servicing is required can be achieved within 5−10 min, as the cartridge is easily exchanged with a spare. A potential application to environmental monitoring has been investigated. The headspace above water spiked with dibutyl mercaptan was sampled with a solid phase microextraction (SPME) fiber, which was then injected directly into the vacuum chamber of the mass spectrometer. Using this method, the limit of detection was found to be approximately 5 ppm for a 15 s sampling period.
- 28 January 2010
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (5) , 1751-1758
Miniature Mass Spectrometer Systems Based on a Microengineered Quadrupole Filter
Two miniature mass spectrometer systems based on a microengineered quadrupole mass filter have been developed. One of the instruments has a footprint of 27 cm × 20 cm and is intended for laboratory use when space is at a premium. The other is portable and intended for use in the field. It is battery powered, weighs 14.9 kg, and is housed in a rugged case. This is the first example of a portable mass spectrometer incorporating an analyzer fabricated using microelectromechanical systems (MEMS) techniques. The starting material for construction of the filters is a bonded silicon on insulator substrate, which is selectively etched using batch processing techniques to form coupling optics and springs that accurately hold 0.5 mm diameter stainless steel rods in the required geometry. Assembled filters measure 35 mm × 6 mm × 1.5 mm and are mounted, together with an ion source and channeltron detector, in small, interchangeable cartridges, which plug into a 220 cm3 vacuum chamber. Recovery from accidental contamination or when servicing is required can be achieved within 5−10 min, as the cartridge is easily exchanged with a spare. A potential application to environmental monitoring has been investigated. The headspace above water spiked with dibutyl mercaptan was sampled with a solid phase microextraction (SPME) fiber, which was then injected directly into the vacuum chamber of the mass spectrometer. Using this method, the limit of detection was found to be approximately 5 ppm for a 15 s sampling period.