Sayedus Salehin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sayedus Salehin has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
A.K.M. Sadrul Islam
2 shared publicationsGovinda Upadhyay
2 shared publications- Mahir Asif Mohammed
Electro‐Optical Communication Group Department of Electrical Engineering Eindhoven University of Technology P.O. Box 512 Eindhoven 5600 MB The Netherlands
2 shared publications S.M. Ferdous
Faculty of Engineering, American International University-Bangladesh (AIUB), Dhaka, Bangladesh
2 shared publications- Taskin Jamal
Department of Electrical and Electronic Engineering, Ahsanullah University of Science and Technology, Dhaka 1208, Bangladesh
2 shared publications - A S M Muhaiminul Hasan
University of Technology Sydney
1 shared publication
Latest Publications
- Open Access
- 17 January 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1741-1756
Bioethanol and biodiesel blended fuels — Feasibility analysis of biofuel feedstocks in Bangladesh
- 17 January 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1741-1756
Open AccessBioethanol and biodiesel blended fuels — Feasibility analysis of biofuel feedstocks in Bangladesh
- 1 January 2017
- Published by Elsevier
- p. 29-71
Environmental Impact Assessment of Different Renewable Energy Resources
- 1 January 2017
- Published by Elsevier
- p. 29-71
Environmental Impact Assessment of Different Renewable Energy Resources
- 1 January 2016
- Published by Elsevier
List of Contributors
- 1 March 2015
- Published by Elsevier in Energy Conversion and Management
- Vol. 93, 205-214
The Energy and Water Emergency Module; A containerized solution for meeting the energy and water needs in protracted displacement situations
- 1 March 2015
- Published by Elsevier in Energy Conversion and Management
- Vol. 93, 205-214
The Energy and Water Emergency Module; A containerized solution for meeting the energy and water needs in protracted displacement situations
- 1 November 2014
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 130, 317-321
Mechanically robust, ITO-free, 4.8% efficient, all-solution processed organic solar cells on flexible PET foil
- 1 November 2014
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 130, 317-321
Mechanically robust, ITO-free, 4.8% efficient, all-solution processed organic solar cells on flexible PET foil
- Open Access
- 8 July 2014
- Published by Wiley in Journal of Renewable Energy
- Vol. 2014, 1-12
Energy Efficient Hybrid Dual Axis Solar Tracking System
This paper describes the design and implementation of an energy efficient solar tracking system from a normal mechanical single axis to a hybrid dual axis. For optimizing the solar tracking mechanism electromechanical systems were evolved through implementation of different evolutional algorithms and methodologies. To present the tracker, a hybrid dual-axis solar tracking system is designed, built, and tested based on both the solar map and light sensor based continuous tracking mechanism. These light sensors also compare the darkness and cloudy and sunny conditions assisting daily tracking. The designed tracker can track sun’s apparent position at different months and seasons; thereby the electrical controlling device requires a real time clock device for guiding the tracking system in seeking solar position for the seasonal motion. So the combination of both of these tracking mechanisms made the designed tracker a hybrid one. The power gain and system power consumption are compared with a static and continuous dual axis solar tracking system. It is found that power gain of hybrid dual axis solar tracking system is almost equal to continuous dual axis solar tracking system, whereas the power saved in system operation by the hybrid tracker is 44.44% compared to the continuous tracking system.
- 8 July 2014
- Published by Wiley in Journal of Renewable Energy
- Vol. 2014, 1-12
Open AccessEnergy Efficient Hybrid Dual Axis Solar Tracking System
This paper describes the design and implementation of an energy efficient solar tracking system from a normal mechanical single axis to a hybrid dual axis. For optimizing the solar tracking mechanism electromechanical systems were evolved through implementation of different evolutional algorithms and methodologies. To present the tracker, a hybrid dual-axis solar tracking system is designed, built, and tested based on both the solar map and light sensor based continuous tracking mechanism. These light sensors also compare the darkness and cloudy and sunny conditions assisting daily tracking. The designed tracker can track sun’s apparent position at different months and seasons; thereby the electrical controlling device requires a real time clock device for guiding the tracking system in seeking solar position for the seasonal motion. So the combination of both of these tracking mechanisms made the designed tracker a hybrid one. The power gain and system power consumption are compared with a static and continuous dual axis solar tracking system. It is found that power gain of hybrid dual axis solar tracking system is almost equal to continuous dual axis solar tracking system, whereas the power saved in system operation by the hybrid tracker is 44.44% compared to the continuous tracking system.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Pump-as-turbine (PAT) for small scale power generation: A comparative analysis
Pumps can be operated as turbines to generate electricity by changing the mode of its operation and reversing the direction of power flow. Since the pump manufacturers usually do not provide datasheet showing the pump's characteristics and performance when operating as turbines, problem arises as to understand how the pump behaves in the turbine mode or reverse running mode. To resolve the problem scientists have developed different mathematical models to find the pump behavior in the turbine mode and its characteristics. In this paper, the BEP (best efficiency point) of a pump operated as turbine (PAT) turbine is mathematically determined using two different methods with the help of the experimentally obtained general pump characteristics data. The BEP is then used to determine the amount of hydraulic power and hence in turn the amount of electrical power that can be generated when an induction machine (operated in generator mode) is coupled to the pump. Also a suitable site is assumed to determine the operating points or range of the PAT using the conventional mathematical models available in many literatures of fluid mechanics.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Pump-as-turbine (PAT) for small scale power generation: A comparative analysis
Pumps can be operated as turbines to generate electricity by changing the mode of its operation and reversing the direction of power flow. Since the pump manufacturers usually do not provide datasheet showing the pump's characteristics and performance when operating as turbines, problem arises as to understand how the pump behaves in the turbine mode or reverse running mode. To resolve the problem scientists have developed different mathematical models to find the pump behavior in the turbine mode and its characteristics. In this paper, the BEP (best efficiency point) of a pump operated as turbine (PAT) turbine is mathematically determined using two different methods with the help of the experimentally obtained general pump characteristics data. The BEP is then used to determine the amount of hydraulic power and hence in turn the amount of electrical power that can be generated when an induction machine (operated in generator mode) is coupled to the pump. Also a suitable site is assumed to determine the operating points or range of the PAT using the conventional mathematical models available in many literatures of fluid mechanics.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Potential rooftop distribution mapping using Geographic Information Systems (GIS) for Solar PV Installation: A case study for Dhaka, Bangladesh
To meet the ever increasing electricity demand in the urban area, roof-top solar PV offers a feasible and alternative solution along with conventional power supply from the electricity grid. Geographic Information Systems can be used as a significantly useful tool for potential rooftop distribution mapping. This paper aims at mapping potential roof-top area available in Dhaka city and evaluating the possible electricity supply from such installations. In this work, ArcGIS software has been used to compile and analyze the geographic data for potential bright roof-top area whereas HOMER has been used to model the energy system and to investigate the energy share from the roof-top PV installations. This type of study will encourage the entrepreneurship in the field of rooftop solar home system in the urban areas of a country.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Potential rooftop distribution mapping using Geographic Information Systems (GIS) for Solar PV Installation: A case study for Dhaka, Bangladesh
To meet the ever increasing electricity demand in the urban area, roof-top solar PV offers a feasible and alternative solution along with conventional power supply from the electricity grid. Geographic Information Systems can be used as a significantly useful tool for potential rooftop distribution mapping. This paper aims at mapping potential roof-top area available in Dhaka city and evaluating the possible electricity supply from such installations. In this work, ArcGIS software has been used to compile and analyze the geographic data for potential bright roof-top area whereas HOMER has been used to model the energy system and to investigate the energy share from the roof-top PV installations. This type of study will encourage the entrepreneurship in the field of rooftop solar home system in the urban areas of a country.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimized model of a solar PV-biogas-diesel hybrid energy system for Adorsho Char Island, Bangladesh
Adorsho Char is an island situated in the bank of Feni River, Bangladesh with a current population of 860. This island is underdeveloped and lacks the electricity supply from the main grid. Majority of the population make use of conventional means i.e candles, lanterns, kerosene wick lamps for lighting the households whereas some market area use solar PV at a very small scale. The aim of this paper is to present an optimized model of a solar PV-biogas-diesel hybrid energy system to provide electricity for the people living in the island. A field survey has been conducted to collect the information about the population, load demand, number of cattle and the current condition present in the island. Hybrid Optimization Model for Electric Renewable (HOMER) has been used to optimize the energy system modelled for daily peak demand of 35 kW (181 kWh/day). Batteries have been considered to facilitate electricity storage. The optimization result from HOMER consisting all energy resources reveals an optimized system architecture of 7.2 kW solar PV, 16 kW biogas generator, 9 kW Diesel generator and 12 batteries (1,900 Ah each) in terms of cost of electricity (COE). This system configuration provides electricity at 17.37 Taka/kWh ($0.217/kWh) with a net present cost of 8,573,095 Taka ($107,163.69).
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimized model of a solar PV-biogas-diesel hybrid energy system for Adorsho Char Island, Bangladesh
Adorsho Char is an island situated in the bank of Feni River, Bangladesh with a current population of 860. This island is underdeveloped and lacks the electricity supply from the main grid. Majority of the population make use of conventional means i.e candles, lanterns, kerosene wick lamps for lighting the households whereas some market area use solar PV at a very small scale. The aim of this paper is to present an optimized model of a solar PV-biogas-diesel hybrid energy system to provide electricity for the people living in the island. A field survey has been conducted to collect the information about the population, load demand, number of cattle and the current condition present in the island. Hybrid Optimization Model for Electric Renewable (HOMER) has been used to optimize the energy system modelled for daily peak demand of 35 kW (181 kWh/day). Batteries have been considered to facilitate electricity storage. The optimization result from HOMER consisting all energy resources reveals an optimized system architecture of 7.2 kW solar PV, 16 kW biogas generator, 9 kW Diesel generator and 12 batteries (1,900 Ah each) in terms of cost of electricity (COE). This system configuration provides electricity at 17.37 Taka/kWh ($0.217/kWh) with a net present cost of 8,573,095 Taka ($107,163.69).