ASAnca Stefanoiu

Anca Stefanoiu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anca Stefanoiu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • What about computational super-resolution in fluorescence Fourier light field microscopy?

    by Anca Stefanoiu, Gabriele Scrofani, Genaro Saavedra, Manuel Martínez-Corral, Tobias Lasser

    Recently, Fourier light field microscopy was proposed to overcome the limitations in conventional light field microscopy by placing a micro-lens array at the aperture stop of the microscope objective instead of the image plane. In this way, a collection of orthographic views from different perspectives are directly captured. When inspecting fluorescent samples, the sensitivity and noise of the sensors are a major concern and large sensor pixels are required to cope with low-light conditions, which implies under-sampling issues. In this context, we analyze the sampling patterns in Fourier light field microscopy to understand to what extent computational super-resolution can be triggered during deconvolution in order to improve the resolution of the 3D reconstruction of the imaged data.


  • Artifact-free deconvolution in light field microscopy

    by Anca Stefanoiu, Josue Page, Panagiotis Symvoulidis, Gil G. Westmeyer, Tobias Lasser

    The sampling patterns of the light field microscope (LFM) are highly depth-dependent, which implies non-uniform recoverable lateral resolution across depth. Moreover, reconstructions using state-of-the-art approaches suffer from strong artifacts at axial ranges, where the LFM samples the light field at a coarse rate. In this work, we analyze the sampling patterns of the LFM, and introduce a flexible light field point spread function model (LFPSF) to cope with arbitrary LFM designs. We then propose a novel aliasing-aware deconvolution scheme to address the sampling artifacts. We demonstrate the high potential of the proposed method on real experimental data.