NBNathalie Brulat-Bouchard

Nathalie Brulat-Bouchard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nathalie Brulat-Bouchard has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental Investigation of Dental Composites Degradation After Early Water Exposure

    by Rémy Gauthier, Hazem Abouelleil, Yoan Boussès, Nathalie Brulat-Bouchard, Pierre Colon, Jean-Marc Chenal, Yannick Tillier, Brigitte Grosgogeat

    While dental composite long-term aging has already been studied in the past, no data exist about the early aging while it might be detrimental regarding the composites' longevity. This study aims to better understand the effects of early water exposure on dental composites. Dental resin composites with different fillers ratio were subjected to water exposure during 24 h, 1 week, or 1 month. After photopolymerization, the samples were stored at different conditions, whether in wet or dry condition (W, D, respectively) and in wet conditions after a first 24 h storage in dry conditions (DW). Three-point bending tests were performed to measure the flexural modulus. The samples were then subjected to a sorption/desorption protocol. While the matrix alone did not undergo any mechanical degradation with exposure time, the composites matrices presented a decrease in elastic modulus. This decrease was the highest for the matrix with nonsilanized fillers. Interestingly, the DW condition was detrimental for all the samples. Regarding the sample with nonsilanized fillers in DW for 1 month presented an elastic modulus lower than the matrix alone. These results were assigned to the sorption capacity of the polymer matrix, suggesting that the diffusion mechanisms and the nature of water molecules are determinant in the composite degradation. This study showed that dental composite early degradation mechanisms after water exposure are involved in the polymer matrix postpolymerization process as soon as after 24 h. Such mechanisms are detrimental in terms of the dental composite efficiency and have to be understood.


  • Theoretical prediction of dental composites yield stress and flexural modulus based on filler volume ratio

    by Yoan Boussès, Nathalie Brulat-Bouchard, Pierre-Olivier Bouchard, Hazem Abouelleil, Yannick Tillier


  • Open Access

    Finishing and polishing effects of multiblade burs on the surface texture of 5 resin composites: microhardness and roughness testing

    by Elodie Ehrmann, Etienne Medioni, Nathalie Brulat-Bouchard

    Ehrmann E, et al. Restor Dent Endod. 2018 Nov;44:e1. https://doi.org/10.5395/rde.2019.44.e1


  • Open Access

    Disilicate Dental Ceramic Surface Preparation by 1070 nm Fiber Laser: Thermal and Ultrastructural Analysis

    by Carlo Fornaini, Federica Poli, Elisabetta Merigo, Nathalie Brulat-Bouchard, Ahmed El Gamal, Jean-Paul Rocca, Stefano Selleri, Annamaria Cucinotta

    Lithium disilicate dental ceramic bonding, realized by using different resins, is strictly dependent on micro-mechanical retention and chemical adhesion. The aim of this in vitro study was to investigate the capability of a 1070 nm fiber laser for their surface treatment. Samples were irradiated by a pulsed fiber laser at 1070 nm with different parameters (peak power of 5, 7.5 and 10 kW, repetition rate (RR) 20 kHz, speed of 10 and 50 mm/s, and total energy density from 1.3 to 27 kW/cm2) and the thermal elevation during the experiment was recorded by a fiber Bragg grating (FBG) temperature sensor. Subsequently, the surface modifications were analyzed by optical microscope, scanning electron microscope (SEM), and energy dispersive X-ray spectroscopy (EDS). With a peak power of 5 kW, RR of 20 kHz, and speed of 50 mm/s, the microscopic observation of the irradiated surface showed increased roughness with small areas of melting and carbonization. EDS analysis revealed that, with these parameters, there are no evident differences between laser-processed samples and controls. Thermal elevation during laser irradiation ranged between 5 °C and 9 °C. A 1070 nm fiber laser can be considered as a good device to increase the adhesion of lithium disilicate ceramics when optimum parameters are considered.


  • Open Access

    One-step partial or complete caries removal and bonding with antibacterial or traditional self-etch adhesives: study protocol for a randomized controlled trial

    by Cyril Villat, Jean-Pierre Attal, Nathalie Brulat, Franck Decup, Sophie Doméjean, Elisabeth Dursun, Hélène Fron-Chabouis, Bruno Jacquot, Michèle Muller Bolla, Nelly Plasse-Pradelle, et al.

    Current concepts in conservative dentistry advocate minimally invasive dentistry and pulp vitality preservation. Moreover, complete removal of carious dentin in deep carious lesions often leads to pulp exposure and root canal treatment, despite the absence of irreversible pulp inflammation. For years, partial caries removal has been performed on primary teeth, but little evidence supports its effectiveness for permanent teeth. Furthermore, the recent development of new antibacterial adhesive systems could be interesting in the treatment of such lesions. The objectives of this study are to compare the effectiveness of partial versus complete carious dentin removal in deep lesions (primary objective) and the use of an antibacterial versus a traditional two-step self-etch adhesive system (main secondary objective). The DEep CAries Treatment (DECAT) study protocol is a multicenter, randomized, controlled superiority trial comparing partial versus complete caries removal followed by adhesive restoration. The minimum sample size required is 464 patients. Two successive randomizations will be performed (allocation ratio 1:1): the first for the type of excavation (partial versus complete) and the second (if no root canal treatment is required) for the type of adhesive (antibacterial versus traditional). For the two objectives, the outcome is the success of the treatment after 1 year, measured according to a composite outcome of five FDI criteria: material fracture and retention, marginal adaptation, radiographic examination (including apical pathologies), postoperative sensitivity and tooth vitality, and carious lesion recurrence. The study will investigate the interest of a conservative approach for the management of deep carious lesions in terms of dentin excavation and bioactive adhesive systems. The results may help practitioners achieve the most efficient restorative procedure to maintain pulp vitality and increase the restoration longevity. ClinicalTrials.gov Identifier NCT02286388 . Registered in November 2014.


  • Shear Bond Strength of Self-Etching Adhesive Systems to Er:YAG Laser-Prepared Dentine with and without Pulpal Pressure Simulation

    by Nathalie Brulat, Eric Leforestier, Jean-Paul Rocca, Evelyne Darquet-Cerretti, Marie-France Bertrand

    Objective: This study was conducted to study the role of pulpal pressure on the shear bond strength of composite resin bonded to Er:YAG laser-prepared or bur-prepared dentine surfaces using a self-etching adhesive system. Materials and Methods: The occlusal surfaces of 80 human third molars were ground flat to expose the dentine. The dentine was prepared using either a carbide bur or an Er:YAG laser at 350 mJ/pulse and 10 Hz (fluence 44.5 J/cm 2 ). Clearfil SE Bond was then applied with or without pressure. Rods of composite resin were bonded to dentine surfaces and shear bond tests were carried out. Results: When the Clearfil SE Bond was used without pressure, the difference between the shear bond strength values of bur-prepared and laser-prepared dentine surfaces was significant. When the Clearfil SE Bond was used with pressure, the difference of shear bond strength values was not significant between the two types of surface preparation. Conclusion: The absence of smear layer formation during the preparation of the dentine by the Er:YAG laser did not improve the adhesion values of self-etching adhesive systems.