Cornelis P.J. Visser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cornelis P.J. Visser has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Arjen Kolk
Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands; Laboratory for Kinematics and Neuromechanics, Department of Orthopaedics and Rehabilitation, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication - Arthur van Noort
Spaarne Gasthuis
1 shared publication Barbara A.M. Snoeker
Department of Epidemiology and Data Science, University Medical Center, Amsterdam, The Netherlands
1 shared publication- Brechtje Hesseling
Reinier Haga Orthopedic Center, Zoetermeer, The Netherlands
1 shared publication Denise Eygendaal
Department of Orthopaedics and Sports Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
1 shared publicationDs de Jong
Department of Extracorporeal Circulation, Academic Hospital Maastricht, Maastricht
1 shared publication
Latest Publications
- Open Access
- 30 January 2026
- Published by Elsevier in JSES International
- Vol. 10 (3) , 101651
Complete fulfillment of expectations is associated with greater satisfaction after shoulder arthroplasty: results from a prospective multicenter cohort study
- 30 January 2026
- Published by Elsevier in JSES International
- Vol. 10 (3) , 101651
Open AccessComplete fulfillment of expectations is associated with greater satisfaction after shoulder arthroplasty: results from a prospective multicenter cohort study
- 21 April 2017
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (6) , 771-778
Outcome and revision rate of uncemented glenohumeral resurfacing (C.A.P.) after 5–8 years
Resurfacing of the glenohumeral joint for patients with glenohumeral arthritis has gained popularity since the first introduction. We report the mid-term results of the Global C.A.P. uncemented resurfacing shoulder prosthesis (DePuy Synthes).
- 21 April 2017
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (6) , 771-778
Outcome and revision rate of uncemented glenohumeral resurfacing (C.A.P.) after 5–8 years
Resurfacing of the glenohumeral joint for patients with glenohumeral arthritis has gained popularity since the first introduction. We report the mid-term results of the Global C.A.P. uncemented resurfacing shoulder prosthesis (DePuy Synthes).
- 1 December 2016
- Published by Elsevier in Manual Therapy
- Vol. 26, 31-37
Subacromial anaesthetics increase asymmetry of scapular kinematics in patients with subacromial pain syndrome
- 1 December 2016
- Published by Elsevier in Manual Therapy
- Vol. 26, 31-37
Subacromial anaesthetics increase asymmetry of scapular kinematics in patients with subacromial pain syndrome
- Open Access
- 1 September 1996
- Published by SAGE Publications in Perfusion
- Vol. 11 (5) , 389-393
Leakage across hollow-fibre membranes in oxygenators: a pilot study
The purpose of this study was to create an in vitro system to quantify the fluid loss over two different types of hollow-fibre membrane oxygenators. In the first stage of the study, the circuit was primed with 0.9% NaCl and the line pressure was 200 mmHg; in the second stage, the line pressure was 400 mmHg. The experiment was repeated using bovine blood. A clear difference (p < 0.005) was found in the first stage, accumulating to 47.46 ml (SD 0.41) in the Capiox-SX group and 72.33 ml (SD 3.77) in the Univox group after 4 h. This difference persisted when using bovine blood. Surprisingly, no differences in volume loss occurred when the line pressure was increased to 400 mmHg. In conclusion, leakage in hollow-fibre microporous polypropylene membrane oxygenators can be quantified and the amount of leakage appears to be dependent on the type of membrane and the manufacturing process.
- 1 September 1996
- Published by SAGE Publications in Perfusion
- Vol. 11 (5) , 389-393
Open AccessLeakage across hollow-fibre membranes in oxygenators: a pilot study
The purpose of this study was to create an in vitro system to quantify the fluid loss over two different types of hollow-fibre membrane oxygenators. In the first stage of the study, the circuit was primed with 0.9% NaCl and the line pressure was 200 mmHg; in the second stage, the line pressure was 400 mmHg. The experiment was repeated using bovine blood. A clear difference (p < 0.005) was found in the first stage, accumulating to 47.46 ml (SD 0.41) in the Capiox-SX group and 72.33 ml (SD 3.77) in the Univox group after 4 h. This difference persisted when using bovine blood. Surprisingly, no differences in volume loss occurred when the line pressure was increased to 400 mmHg. In conclusion, leakage in hollow-fibre microporous polypropylene membrane oxygenators can be quantified and the amount of leakage appears to be dependent on the type of membrane and the manufacturing process.