Kun Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kun Ye has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Liang Hu
2 shared publicationsYan Xiao
School of Civil Engineering and Mechanics, Huazhong University of Science and Technology University, Wuhan, China
2 shared publicationsYuxiang Wang
2 shared publicationsGuang-Jie Hu
1 shared publication- Haosheng Zhou1 shared publication
Hongping Zhu
College of Civil Engineering and Mechanics Huazhong University of Science and Technology Wuhan China
1 shared publication
Latest Publications
- 31 January 2025
- Published by Elsevier in Engineering Structures
- Vol. 329
Enhancing base-isolation structures by optimized configurable friction isolator-tuned inerter damper system
- 31 January 2025
- Published by Elsevier in Engineering Structures
- Vol. 329
Enhancing base-isolation structures by optimized configurable friction isolator-tuned inerter damper system
- 20 November 2023
- Published by Elsevier in Structures
- Vol. 58
Study on rocking response of base-isolated structure considering the tensile effect of isolators
- 20 November 2023
- Published by Elsevier in Structures
- Vol. 58
Study on rocking response of base-isolated structure considering the tensile effect of isolators
- 28 September 2023
- Published by Elsevier in Structures
- Vol. 57
Design and analysis of LRB base-isolated building structure for multilevel performance targets
- 28 September 2023
- Published by Elsevier in Structures
- Vol. 57
Design and analysis of LRB base-isolated building structure for multilevel performance targets
- 19 November 2021
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 21 (3) , 1651-1684
Enhancing the seismic performance of dual-isolated structure with optimal supplemental inerters
- 19 November 2021
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 21 (3) , 1651-1684
Enhancing the seismic performance of dual-isolated structure with optimal supplemental inerters
- 3 April 2020
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 18 (8) , 4039-4059
An improved response surface method for fragility analysis of base-isolated structures considering the correlation of seismic demands on structural components
- 3 April 2020
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 18 (8) , 4039-4059
An improved response surface method for fragility analysis of base-isolated structures considering the correlation of seismic demands on structural components
- 1 October 2019
- Published by Elsevier in Engineering Structures
- Vol. 197
A direct displacement-based design procedure for base-isolated building structures with lead rubber bearings (LRBs)
- 1 October 2019
- Published by Elsevier in Engineering Structures
- Vol. 197
A direct displacement-based design procedure for base-isolated building structures with lead rubber bearings (LRBs)
- 18 March 2019
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 48 (9) , 1083-1090
Analytical solution of seismic response of base‐isolated structure with supplemental inerter
Summary: Closed‐form solutions are derived for the modal characteristics and seismic response of a base‐isolated structure equipped with additional inerters. By simplifying the structure‐isolator‐inerter system in terms of the two‐degree‐of‐freedom (2DOF) model, the modal frequencies, mode shapes, damping ratios, and participation factors of the system are derived. Consequently, analytical seismic response solutions are formulated by the modal superposition method. Utilizing these analytical solutions, an extensive parametric study has been carried out to investigate the effect of supplement inerters on both the modal characteristics and seismic response of the structure‐isolator‐inerter system. There is a critical inertance leading to the zero second modal participation factor (ie, the disappearance of the second modal response). The associated critical inertance ratio is derived in closed form as well. Moreover, it is observed that the reduction of deformation of isolators by increasing the inertance may be offset by the increase in relative displacements of the superstructure. To circumvent this adverse effect, an optimal range of inertance is identified whereby both the deformation of isolators and the relative displacement of the superstructure are mitigated concurrently.
- 18 March 2019
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 48 (9) , 1083-1090
Analytical solution of seismic response of base‐isolated structure with supplemental inerter
Summary: Closed‐form solutions are derived for the modal characteristics and seismic response of a base‐isolated structure equipped with additional inerters. By simplifying the structure‐isolator‐inerter system in terms of the two‐degree‐of‐freedom (2DOF) model, the modal frequencies, mode shapes, damping ratios, and participation factors of the system are derived. Consequently, analytical seismic response solutions are formulated by the modal superposition method. Utilizing these analytical solutions, an extensive parametric study has been carried out to investigate the effect of supplement inerters on both the modal characteristics and seismic response of the structure‐isolator‐inerter system. There is a critical inertance leading to the zero second modal participation factor (ie, the disappearance of the second modal response). The associated critical inertance ratio is derived in closed form as well. Moreover, it is observed that the reduction of deformation of isolators by increasing the inertance may be offset by the increase in relative displacements of the superstructure. To circumvent this adverse effect, an optimal range of inertance is identified whereby both the deformation of isolators and the relative displacement of the superstructure are mitigated concurrently.