Stavros A. Papathanassiou has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessing the Impact of Climate Conditions Within CEP Models: A Comparative Study of Scenario Reduction Methods

    by Evangelos S. Chatzistylianos, Georgios N. Psarros, Pantelis A. Dratsas, Stavros A. Papathanassiou

    This paper presents a climate-aware stochastic capacity expansion planning (CEP) framework that addresses the growing need for robust policy and investment decisions towards high renewable penetration, giving due consideration to climate variability. The developed model incorporates demand, renewable generation, and hydro inflows for 35 climate years, preserving intra-annual variability, correlation of resources, and variance of climate conditions. To address the computational burden of fully stochastic models, several clustering techniques are assessed, namely k-means, k-medoids, hierarchical, and a novel cost-driven approach. Unlike traditional clustering methods, the cost-driven approach clusters climate years according to their impact on system cost, delivering near-optimal results with more than a 90% reduction in computation time. The study also explores whether deterministic model runs, i.e. solving for each climate year individually, can approximate the stochastic optimum. A percentile-based analysis shows that energy mixes derived from intermediate-to-upper percentiles of the capacity envelope can approximate optimal cost within about 3-5%. Overall, these findings highlight the importance of considering multiple climate years and selecting appropriate scenario reduction techniques to ensure robust and cost-effective system planning.


  • Contribution of PV Generation With Embedded Battery Storage to Capacity Adequacy

    by Pantelis A. Dratsas, Georgios N. Psarros, Stavros A. Papathanassiou

    This paper proposes a real-time redispatch method for including PV-plus-battery plants in resource adequacy assessment (RAA) studies. The method offers the possibility to represent the market operation of the assets, while at the same time considering their response to reliability events, unlike existing methods in the literature that manage such assets in a single-dimensional manner, driven solely by adequacy contribution considerations or entirely ignoring this capability. In the proposed method, while the plant is initially dispatched in a market-oriented manner, i.e., with the objective of maximizing market revenues, its actual operation is adapted to meet system needs when reliability events take place. The method is incorporated into a Monte Carlo (MC) based RAA model in a computationally efficient manner, relying on a deterministic implementation of redispatching that does not impact significantly the computational burden of the RAA model, thus enabling the execution of multiple MC samples to achieve a high stochastic process accuracy. A merit order algorithm is also embedded into the RAA model to evaluate the PV-plus-battery market revenues. The model developed allows a refined calculation of the capacity value (CV) of such assets for different plant configurations and inverter loading ratios, while the upper and lower CV bounds are approximated via application of the adequacy- and market-oriented approaches available in the literature. Results show that the embedded storage energy capacity is crucial for the CV afforded by the assets, while any decrease in the inverter capacity does not significantly impact the CV value. Further, the CV of storage embedded in tightly coupled PV-plus-battery plants, where batteries are exclusively charged by the plant's own PV generation, is generally lower than the value of similar stand-alone storages operating without any charging constraints.


  • Open Access

    A Novel Method to Integrate Hydropower Plants into Resource Adequacy Assessment Studies

    by Christiana I. Kostaki, Pantelis A. Dratsas, Georgios N. Psarros, Evangelos S. Chatzistylianos, Stavros A. Papathanassiou

    This paper presents a novel methodology for modeling hydropower plants (HPPs) with and without pumping capability in resource adequacy assessment studies. The proposed method is based on the premise that HPPs should maximize their contribution to system adequacy within their technical constraints by using the energy reserves in their upper reservoirs without significantly deviating from their market schedule. The approach of this paper differs from the conventional operating policies for incorporating HPPs into resource adequacy assessment studies, which either adhere to a fixed market schedule or perform peak shaving, and are inelastic to real-time events or do not resort to realistic temporal correlations between natural water inflows on upper reservoirs and the water discharge needs to cover demand peaks, respectively. The modeling approach focuses on large-reservoir HPPs with natural inflows and is generic enough to deal with both stations incorporating pumping capabilities and those without. It utilizes the state-of-the-art Monte Carlo simulation technique to form the availability of system assets and determine the loss of load incidents. The market schedule and level of reservoir fulfillment for the HPPs are retrieved from a cost-optimal power system simulation algorithm executed offline before the application of the resource adequacy assessment. The effectiveness of the proposed methodology is demonstrated through its implementation in a case study of a power system experiencing different levels of adequacy, comparing the obtained results with various traditional HPP modeling methods from the literature.


  • Open Access

    Export Constraints Applicable to Renewable Generation to Enhance Grid Hosting Capacity

    by Evangelos S. Chatzistylianos, Georgios N. Psarros, Stavros A. Papathanassiou

    This paper investigates grid export constraints applicable to photovoltaic (PV) and wind farm (WF) installations, both with and without behind-the-meter storage, aimed at enhancing grid hosting capacity. The study focuses on static output power limitations, i.e., simple export constraints that are preventively imposed on renewable energy source (RES) plants regardless of the prevailing network congestion conditions. These constraints are easy to apply, implemented ex ante and out of market, and do not require additional investments in energy storage or advanced devices. They also yield a measurable increase in hosting capacity and grid utilization, with their impact on RES plant operation and return of investment straightforwardly calculable. Analysis defines the level and shape of these constraints assuming an indicative acceptable curtailment level of 5% for each RES technology attributed to the preventing action of the imposed limitations, while the respective implications for RES energy yield and investment viability are explored. The findings indicate that an export power limitation of ca. 68% is effective for stand-alone PVs, while a stepwise static limitation is necessary for stand-alone WFs and WFs with integrated storage to manage midday solar generation peaks. PV plants tightly coupled with storage facilities can handle static limitations as low as 35% with minimal impact on the economic feasibility of the investments.


  • Open Access

    Insights from a Comprehensive Capacity Expansion Planning Modeling on the Operation and Value of Hydropower Plants under High Renewable Penetrations

    by Evangelos S. Chatzistylianos, Georgios N. Psarros, Stavros A. Papathanassiou

    This paper presents a quantitative assessment of the value of hydroelectric power plants (HPPs) in power systems with a significant penetration of variable renewable energy sources (VRESs). Through a capacity expansion planning (CEP) model that incorporates a detailed representation of HPP operating principles, the study investigates the construction and application of HPP rule curves essential for seasonal operation. A comparative analysis is also conducted between the proposed rule curve formulation and alternative modeling techniques from the literature. The CEP model optimizes installed capacities per technology to achieve predefined VRES penetration targets, considering hourly granularity and separate rule curves for each HPP. A case study involving twelve reservoir hydropower stations and two open-loop pumped hydro stations is examined, accounting for standalone plants and cascaded hydro systems across six river basins. The study evaluates the additional generation and storage required to replace the hydropower fleet under high VRES penetration levels, assessing the resulting increases in total system cost emanating from introducing such new investments. Furthermore, the study approximates the storage capabilities of HPPs and investigates the impact of simplified HPP modeling on system operation and investment decisions. Overall, the findings underscore the importance of reevaluating hydro rule curves for future high VRES penetration conditions and highlight the significance of HPPs in the energy transition towards carbon neutrality.


  • Open Access

    A comprehensive review of electricity storage applications in island systems

    by Georgios N. Psarros, Pantelis A. Dratsas, Stavros A. Papathanassiou

    Electricity storage is crucial for power systems to achieve higher levels of renewable energy penetration. This is especially significant for non-interconnected island (NII) systems, which are electrically isolated and vulnerable to the fluctuations of intermittent renewable generation. This paper comprehensively reviews existing literature on electricity storage in island systems, documenting relevant storage applications worldwide and emphasizing the role of storage in transitioning NII towards a fossil-fuel-independent electricity sector. On this topic, the literature review indicates that the implementation of storage is a prerequisite for attaining renewable penetration rates of over 50% due to the amplified requirements for system flexibility and renewable energy arbitrage. The analysis also identifies potential storage services and classifies applicable storage architectures for islands. Amongst the available storage designs, two have emerged as particularly important for further investigation; standalone, centrally managed storage stations and storage combined with renewables to form a hybrid plant that operates indivisibly in the market. For each design, the operating principles, remuneration schemes, investment feasibility, and applications discussed in the literature are presented in-depth, while possible implementation barriers are acknowledged. The literature on hybrid power plants mainly focuses on wind-powered pumped-hydro stations. However, recently, PV-powered battery-based hybrid plants have gained momentum due to the decreasing cost of Li-ion technology. On the other hand, standalone storage establishments rely heavily on battery technology and are mainly used to provide flexibility to the island grid. Nevertheless, these investments often suffer from insufficient remunerating frameworks, making it challenging for storage projects to be financially secure.

  • Open Access

    Impact of Natural Gas Price Variations and Consumption Limitation on the Decarbonization of Sector-Coupled Energy Systems

    by Periklis P. Chinaris, Georgios N. Psarros, Evangelos S. Chatzistylianos, Stavros A. Papathanassiou

    This paper assesses the effects of fossil natural gas (NG) price variations and NG consumption restrictions on the development and decarbonization of future cross-sector and cross-vector coupled energy systems. For this purpose, a capacity expansion planning model built upon the linear programming mathematical optimization is developed, optimizing operation and investment in technologies for generation, storage, conversion and final consumption of electricity, hydrogen (H2), and NG, while carbon dioxide (CO2) sector encompassing carbon capture, storage and utilization is incorporated in the model. A base case scenario adopting REPowerEU expectations about NG price levels by 2050 is analyzed, with the Greek sector-coupled energy system selected as a case study, aiming to demonstrate that anticipated NG price is inadequate to stimulate full decarbonization of the integrated energy system and even moderately reduce dependence on NG. Thus, increased fossil NG prices and consumption restrictions are assessed regarding their potential contribution towards incentivizing energy system complete decarbonization. Decarbonization is achieved both with a NG price of 120 €/MWh and with elimination of fossil NG consumption, at a similar cost, yet with a different energy system development. In both cases, a cumulative renewable energy sources (RES) capacity of 106 GWe accompanied by substantial long-duration storage is required. Interestingly, as decarbonization levels increase, onshore wind farms prevail over PVs in the generation mix. Residential heating-cooling and transport needs are predominantly electrified, while industrial heating is exclusively supplied by Η2.


  • Open Access

    Solutions to Enhance Frequency Regulation in an Island System With Pumped-Hydro Storage Under 100% Renewable Energy Penetration

    by Apostolos G. Papakonstantinou, Apostolos I. Konstanteas, Stavros A. Papathanassiou

    Seeking 100% renewable energy source (RES) penetration in low-inertia, isolated grids presents major challenges, including frequency control and stability. This is the case in small island systems relying on variable RES and pumped-hydro storage, where the limited ramping capabilities of hydro turbines compromise their frequency response. In this study, solutions are examined to allow the operation of such systems under 100% RES conditions. The Greek island of Ikaria is used as a study case, supplied by a hybrid RES-storage facility, consisting of hydroelectric units, a pumping facility and a wind farm. Solutions under study include the implementation of deflector control to allow provision of fast reserves by the Pelton hydro turbines, primary reserves provision by the wind farm, the enhancement of the variable speed pump control to contribute to primary frequency regulation, and, at a further step, the installation of battery energy storage to provide fast response for effective frequency regulation. All solutions are comparatively assessed via simulation to demonstrate that the proposed deflector control allows effective frequency regulation, albeit at the detriment of energy efficiency, whereas the variable speed pumps may also contribute to primary regulation in case of contingencies. It is battery storage that would decisively enhance frequency control and security of operation, while also allowing for improved tracking of wind power variations in normal operation; best results are achieved when batteries are combined with the other supplementary regulation measures, allowing a reduced battery capacity.


  • A Real-Time Redispatch Method to Evaluate the Contribution of Storage to Capacity Adequacy

    by Pantelis A. Dratsas, Georgios N. Psarros, Stavros A. Papathanassiou

    This paper proposes a novel real-time redispatch method for energy storage systems (ESSs) in resource adequacy studies. In case of real-time contingencies, a realistic operating profile is generated for ESSs to enhance system reliability by mitigating loss of load events, while maintaining their market schedule to the extent possible. Contrary to the standard approaches in the literature, the proposed method neither adopts a perfect foresight for future events, such as generator failures, nor does it resort to “greedy” adequacy-oriented management strategies which are detached from normal operation. Instead, storages follow a market-driven schedule, being suitably redispatched during real-time operation when necessary for adequacy reasons, subject to their energy and power capacity constraints. The redispatch method is deterministically formulated through a sequence of logical conditions and is integrated into a stochastic adequacy assessment model built upon Monte Carlo technique. Multiple battery energy storage configurations have been examined, with the Greek power system serving as a realistic case study, to evaluate the method against others available in the literature and calculate the capacity value of battery ESS.


  • Open Access

    Feasibility of Behind-the-Meter Battery Storage in Wind Farms Operating on Small Islands

    by Pantelis A. Dratsas, Georgios N. Psarros, Stavros A. Papathanassiou

    This paper investigates the anticipated benefits from the introduction of a battery energy storage system (BESS) behind-the-meter (BtM) of a wind farm (WF) located in a small non-interconnected island (NII) system. Contrary to the standard storage deployment applications for NII, where storage is either installed in front of the meter as a system asset or integrated into a virtual power plant with renewable energy sources, the BESS of this paper is utilized to manage the power injection constraints imposed on the WF, aiming to minimize wind energy curtailments and improve WF’s yield. A mixed integer linear programming generation scheduling model is used to simulate the operation of the system and determine the permissible wind energy absorption margin. Then, a self-dispatch algorithm is employed for the operation of the WF–BESS facility, using the BESS to manage excess wind generation that cannot be directly delivered to the grid. Additionally, the contribution of BESS to the capacity adequacy of the NII system is investigated using a Monte Carlo-based probabilistic model, amended appropriately to incorporate storage. Finally, an economic feasibility analysis is carried out, considering the possible revenue streams. By examining several BESS configurations, it has been shown that BtM BESS reduces energy curtailments and contributes substantially to resource adequacy as its energy capacity increases. However, the investment feasibility is only ensured if the capacity value of the BtM storage is properly monetized or additional dependability of wind production is claimed on the ground that the inherent intermittency of the wind production is mitigated owing to storage.