Srdjan Jelacic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Srdjan Jelacic has a total of 173 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Bowdle
Department of Anesthesiology, University of Washington, Seattle, Washington
11 shared publications Andrew Bowdle
Department of Anesthesiology, University of Washington, Seattle, Washington
9 shared publicationsSandra L. Watkins
Divisions of Gastroenterology and Nephrology, Seattle Children's Hospital, Washington
7 shared publications- Marcia Aparecida Ciol
University of Washington
6 shared publications Phillip I. Tarr
Children’s Hospital and Regional Medical Center, Seattle, Washington
6 shared publicationsBala G. Nair
Perimatics LLC , Bellevue, Washington
5 shared publications
Latest Publications
- Open Access
- 1 November 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (11) , e014224
Transcatheter Mitral Valve Replacement Using Annular Reduction by Cinching With TEER in the Commissure (ARCTIC)
BACKGROUND: Mitral annular calcification with valve dysfunction remains a challenging syndrome. Operative risk is high, and available transcatheter therapies are limited. METHODS: This study describes our initial experience with a novel procedure to address large mitral annuli when no surgical or trial-based transcatheter mitral valve replacement device is available. The rationale was to shorten the intercommissural distance using commissural mitral transcatheter edge-to-edge repair (TEER) followed by valve-in-mitral annular calcification transcatheter mitral valve replacement with a balloon-expandable aortic valve platform. Patients with long intercommissural distances and large mitral annulus areas were selected based on a high perceived risk of transcatheter valve embolization. Patients underwent mitral TEER with MitraClip in a commissural position, followed immediately by transseptal transcatheter mitral valve replacement with a 29 mm SAPIEN 3 valve. RESULTS: Thirteen patients were included. Median intercommissural distance and annular area were 39.1 mm and 930 mm 2 , respectively. Commissural mitral TEER was successful in all patients with no instances of single leaflet detachment. In 10 of 13 instances, an NTW device size was used. In 12 of 13 patients, valve implantation was successful, including 1 case that required a second valve for atrial positioning of the first valve. In 1 case, frank valve embolization into the left atrium occurred. Among the 12 successful cases, paravalvular leak was 1+ or less, and there were no instances of paravalvular leak adjacent to the TEER device. CONCLUSIONS: In patients with large annuli and sufficient annular calcium, a hybrid mitral TEER and valve replacement with the SAPIEN platform can be successfully used to facilitate transcatheter mitral valve replacement.
- 1 November 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (11) , e014224
Open AccessTranscatheter Mitral Valve Replacement Using Annular Reduction by Cinching With TEER in the Commissure (ARCTIC)
BACKGROUND: Mitral annular calcification with valve dysfunction remains a challenging syndrome. Operative risk is high, and available transcatheter therapies are limited. METHODS: This study describes our initial experience with a novel procedure to address large mitral annuli when no surgical or trial-based transcatheter mitral valve replacement device is available. The rationale was to shorten the intercommissural distance using commissural mitral transcatheter edge-to-edge repair (TEER) followed by valve-in-mitral annular calcification transcatheter mitral valve replacement with a balloon-expandable aortic valve platform. Patients with long intercommissural distances and large mitral annulus areas were selected based on a high perceived risk of transcatheter valve embolization. Patients underwent mitral TEER with MitraClip in a commissural position, followed immediately by transseptal transcatheter mitral valve replacement with a 29 mm SAPIEN 3 valve. RESULTS: Thirteen patients were included. Median intercommissural distance and annular area were 39.1 mm and 930 mm 2 , respectively. Commissural mitral TEER was successful in all patients with no instances of single leaflet detachment. In 10 of 13 instances, an NTW device size was used. In 12 of 13 patients, valve implantation was successful, including 1 case that required a second valve for atrial positioning of the first valve. In 1 case, frank valve embolization into the left atrium occurred. Among the 12 successful cases, paravalvular leak was 1+ or less, and there were no instances of paravalvular leak adjacent to the TEER device. CONCLUSIONS: In patients with large annuli and sufficient annular calcium, a hybrid mitral TEER and valve replacement with the SAPIEN platform can be successfully used to facilitate transcatheter mitral valve replacement.
- 17 June 2024
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 139 (1) , e3-e4
Checklist Design, Format, and Content: Benefits of Aviation-Style Computerized Checklists
- 17 June 2024
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 139 (1) , e3-e4
Checklist Design, Format, and Content: Benefits of Aviation-Style Computerized Checklists
- 10 May 2024
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 141 (2) , 262-271
Accuracy and Precision of Three Acceleromyographs, Three Electromyographs, and a Mechanomyograph Measuring the Train-of-four Ratio in the Absence of Neuromuscular Blocking Drugs
Background: The accuracy and precision of currently available, widely used acceleromyograph and electromyograph neuromuscular blockade monitors have not been well studied. In addition, the normalization of the train-of-four ratio from acceleromyography (train-of-four ratio [T4/T1] divided by the baseline train-of-four ratio) has not been validated in comparison to mechanomyography. Methods: Enrolled patients had surgery under general anesthesia with a supraglottic airway and without any neuromuscular blocking drugs. Three acceleromyograph monitors, three electromyograph monitors, and a mechanomyograph built in the authors’ laboratory were tested. Most patients had an electromyograph and the mechanomyograph on one arm and a third monitor on the contralateral arm. Train-of-four ratios were collected every 12 to 20 s for the duration of the anesthetic. At least 1,000 train-of-four ratios were recorded for each device. Gauge repeatability and reproducibility analysis was performed. Results: Twenty-eight patients were enrolled. In total, 9,498 train-of-four ratio measurements were collected. Since no neuromuscular blocking drugs were used, the expected train-of-four ratio was 1.0. All of the acceleromyograph monitors produced overshoot in the train-of-four ratio (estimated means, 1.10 to 1.13) and substantial variability (gauge SDs, 0.07 to 0.18). Normalization of the train-of-four ratio measured by acceleromyography improved the estimated mean for each device (0.97 to 1.0), but the variability was not improved (gauge SDs, 0.06 to 0.17). The electromyograph and the mechanomyograph monitors produced minimal overshoot (estimated means, 0.99 to 1.01) and substantially less variation (gauge SDs, 0.01 to 0.02). For electromyography and mechanomyography, 0.3% of all train-of-four ratios were outside of the range 0.9 to 1.1. For acceleromyography, 27 to 51% of normalized train-of-four ratios were outside the range of 0.9 to 1.1. Conclusions: Three currently available acceleromyograph monitors produced overshoot and substantial variability that could be clinically significant. Normalization corrected the overshoot in the average results but did not reduce the wide variability. Three electromyograph monitors measured the train-of-four ratio with minimal overshoot and variability, similar to a mechanomyograph. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
- 10 May 2024
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 141 (2) , 262-271
Accuracy and Precision of Three Acceleromyographs, Three Electromyographs, and a Mechanomyograph Measuring the Train-of-four Ratio in the Absence of Neuromuscular Blocking Drugs
Background: The accuracy and precision of currently available, widely used acceleromyograph and electromyograph neuromuscular blockade monitors have not been well studied. In addition, the normalization of the train-of-four ratio from acceleromyography (train-of-four ratio [T4/T1] divided by the baseline train-of-four ratio) has not been validated in comparison to mechanomyography. Methods: Enrolled patients had surgery under general anesthesia with a supraglottic airway and without any neuromuscular blocking drugs. Three acceleromyograph monitors, three electromyograph monitors, and a mechanomyograph built in the authors’ laboratory were tested. Most patients had an electromyograph and the mechanomyograph on one arm and a third monitor on the contralateral arm. Train-of-four ratios were collected every 12 to 20 s for the duration of the anesthetic. At least 1,000 train-of-four ratios were recorded for each device. Gauge repeatability and reproducibility analysis was performed. Results: Twenty-eight patients were enrolled. In total, 9,498 train-of-four ratio measurements were collected. Since no neuromuscular blocking drugs were used, the expected train-of-four ratio was 1.0. All of the acceleromyograph monitors produced overshoot in the train-of-four ratio (estimated means, 1.10 to 1.13) and substantial variability (gauge SDs, 0.07 to 0.18). Normalization of the train-of-four ratio measured by acceleromyography improved the estimated mean for each device (0.97 to 1.0), but the variability was not improved (gauge SDs, 0.06 to 0.17). The electromyograph and the mechanomyograph monitors produced minimal overshoot (estimated means, 0.99 to 1.01) and substantially less variation (gauge SDs, 0.01 to 0.02). For electromyography and mechanomyography, 0.3% of all train-of-four ratios were outside of the range 0.9 to 1.1. For acceleromyography, 27 to 51% of normalized train-of-four ratios were outside the range of 0.9 to 1.1. Conclusions: Three currently available acceleromyograph monitors produced overshoot and substantial variability that could be clinically significant. Normalization corrected the overshoot in the average results but did not reduce the wide variability. Three electromyograph monitors measured the train-of-four ratio with minimal overshoot and variability, similar to a mechanomyograph. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
- 26 April 2024
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 133 (1) , 19-23
Reducing airborne transmissible diseases in perioperative environments
- 26 April 2024
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 133 (1) , 19-23
Reducing airborne transmissible diseases in perioperative environments
- 27 March 2024
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 132 (6) , 1330-1331
Under-dosing and over-dosing of neuromuscular blocking drugs and reversal agents. Response to Br J Anaesth 2024; 132: 461–5
- 27 March 2024
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 132 (6) , 1330-1331
Under-dosing and over-dosing of neuromuscular blocking drugs and reversal agents. Response to Br J Anaesth 2024; 132: 461–5
- 1 January 2024
- Published by Springer Nature
- p. 721-739
Infection Prevention in Anesthesiology
- 31 October 2023
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 92, 111310
Should respiratory therapists routinely monitor neuromuscular blockade in the intensive care unit?
- 31 October 2023
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 92, 111310
Should respiratory therapists routinely monitor neuromuscular blockade in the intensive care unit?
- 3 October 2023
- Published by Springer Nature in Current Anesthesiology Reports
- Vol. 13 (4) , 229-238
Monitoring Depth of Neuromuscular Blockade
- 3 October 2023
- Published by Springer Nature in Current Anesthesiology Reports
- Vol. 13 (4) , 229-238
Monitoring Depth of Neuromuscular Blockade
- 13 September 2023
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 131 (5) , 796-801
Lessons from aviation safety: pilot monitoring, the sterile flight deck rule, and aviation-style computerised checklists in the operating room
- 13 September 2023
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 131 (5) , 796-801
Lessons from aviation safety: pilot monitoring, the sterile flight deck rule, and aviation-style computerised checklists in the operating room