Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marina Amaral has a total of 136 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Manufacturing, Installation and Adjustment of Rigid Interocclusal Splint for Control of Bruxism and Orofacial Pain

    by Isadora Infante, Danielle Treviso, Maria Clara Gomes Gonçalves de Almeida, Matheus Moraes de Aguiar, Erika Matsumura, Marina Amaral, Paulo Francisco Cesar, Lucas Hian da Silva

    Bruxism and orofacial muscle pain are common clinical conditions that may lead to tooth wear, muscle fatigue, and discomfort during mastication. Rigid occlusal splints, particularly those based on the Michigan occlusal splint design, are widely used to control these symptoms and protect the dentition. This case report describes a 20-year-old female patient who presented with persistent pain in the masseter and temporalis muscles, exacerbated during mastication, and muscle fatigue upon waking. After a detailed occlusal and radiographic examination, a diagnosis of probable sleep bruxism with mild tooth wear was established based on self-reported symptoms and clinical signs, without instrumental confirmation. Treatment involved obtaining impressions of the upper and lower arches, recording the centric relation with a Lucia JIG, mounting the plaster models in a semi-adjustable articulator, and fabricating a rigid splint from injectable acrylic resin (IvoBase®). The interocclusal splint was adjusted for optimal occlusal contact, ensuring patient comfort and promoting reduction of muscle tension. Pain intensity was assessed using a 100 mm visual analogue scale (VAS) and pain-related impact using the Graded Chronic Pain Scale – Revised (GCPS-R, v2.0). At baseline, the patient presented a VAS score of 45 mm and GCPS-R Grade I. After 7 days of nocturnal use, the VAS score decreased to 20 mm and the GCPS-R grade improved to Grade 0. At the 3-month follow-up, the pain-free status was maintained (VAS 0 mm, GCPS-R Grade 0), with good adherence and no adverse events. This case highlights the role of the rigid Michigan-type occlusal splint as an adjunct in the management of probable sleep bruxism, emphasising the importance of precise fabrication and adjustment for therapeutic success.

  • Open Access

    Special Issue “Characteristics of Dental Ceramics”

    by Marina Amaral, Kusai Baroudi

    Dental ceramics have become indispensable materials in contemporary restorative and prosthetic dentistry

  • Open Access

    Clinical Adjustment of Zirconia-Reinforced Lithium Silicate and Lithium Disilicate Restorations Should Be Performed Before Crystallization

    by Kusai Baroudi, Nathália Ribeiro de Almeida, Laura Salerno de Abreu, Vinícius Felipe Wandscher, Nathalia de Carvalho Ramos, Vivek Padmanabhan, Caroline Andrade Bucholz, Marina Amaral

    The objective of this study was to evaluate the biaxial flexural strength of zirconia-reinforced lithium silicate (ZLS, eMax CAD, Ivoclar Vivadent) and lithium disilicate (LDS, Suprinity, VITA)) discs after abrasion with a diamond tip, before or after crystallization of the ceramic. Discs of 1.2 × 15 mm dimensions were fabricated. The samples were separated into two groups: AC—abrasion with a diamond tip before material crystallization, and CA—material crystallization and subsequent abrasion with a diamond tip (n = 15). The initial roughness was measured before abrasion/crystallization, and final measurement was performed after abrasion/crystallization/polishing. The abraded surface was placed downward during the biaxial flexural strength test, and the data were recorded. The final roughness was significantly higher compared to the initial roughness in all groups. The ZLS-AC and LDS-AC groups (both materials with abrasion prior to material crystallization) showed higher biaxial flexural strength values than groups that underwent abrasion before crystallization. This study concluded that the clinical adjustment performed by abrasion with the diamond tip of glass ceramics lithium disilicate and zirconia-reinforced lithium silicate carried out prior to crystallization favored the resistance of the ceramics.


  • Open Access

    Cortisone Analysis by FTIR Spectroscopy: In Vitro Study

    by Luciana Paula Benício Arcas, Sara Maria Santos Dias da Silva, Felipe Carlos Dias Arcas, Flávio Henrique Alves, Luís Felipe das Chagas e Silva de Carvalho, Marina Amaral

    Cortisol, known as the “stress hormone”, is vital for stress response, metabolism regulation, and immune function, and salivary cortisone reflects serum cortisol levels. The measurement of salivary cortisone levels has been proposed as an effective alternative method for estimating serum cortisol levels. Objective: This study aimed to evaluate the use of Fourier Transform Infrared Spectroscopy (FTIR) for salivary cortisone identification and quantification and to assess the impact of adding the surfactant TWEEN 80 to the analysis. Methods: Initially, cortisone was diluted in chloroform and methanol (5,000,000 µg/dL). FTIR spectra were obtained, and absorbance characteristics and peaks were identified. The spectrum of this initial dilution was processed using the Savitzky-Golay filter to evaluate peak heights at 1655 cm−1 and 1700 cm−1, and the effect of signal processing on these peaks was assessed. Additionally, two series of dilutions were performed by adding the surfactant TWEEN 80 at two different concentrations, and the effect of the surfactant on the cortisone spectra was evaluated to reduce noise and enhance the signal. Results: The spectra obtained from the cortisone solution were similar to those found in the literature for solid samples. The peak corresponding to the wavenumber range of 1600–1680 cm−1, related to the stretching bands of C=C, was found to be reliable for use in cortisone quantification studies. The standard deviation between the spectra of the same sample was less than 0.01. It was not possible to detect cortisone when TWEEN 80 was added; however, with signal processing, TWEEN 80 could be detected in quantities as low as 0.0033% of the solution. Conclusions: FTIR demonstrates potential as a non-invasive method for cortisone analysis. While Tween 80 aids in the dilution of cortisone in water, it obscures its spectrum.


  • Open Access

    Técnicas de manejo atitudinal para a higiene bucal de crianças com Transtorno do Espectro Autista: uma revisão integrativa

    by Luiz Gustavo Centurion de Moura, Andréa Filipini Rodrigues Lauermann, Anna Laura Almeida Barreto, Marina Amaral, Natália Abou Hala Nunes, Sheila Cavalca Cortelli

    O número de casos de crianças diagnosticadas com o Transtorno do Espectro do Autismo (TEA) nos últimos anos teve um aumento significativo. A comunicação restritiva e a falta de interação social apresentadas por este grupo ocasionam um ambiente não estimulante para atividades de rotina diária como a escovação dental, e a seletividade alimentar que configura numa dieta rica em alimentos cariogênicos. Uma revisão integrativa nas bases de dados PUBMED (The US National Library of Medicine), BIREME (Latin American and Caribean Health Sciences Information Database) e SCIELO (The Scientific Eletronic Library) buscou responder a seguinte questão: "Quais técnicas de manejo atitudinal contribuem para a higiene e saúde bucal em crianças com TEA?" A análise dos resultados foi feita através do modelo de fluxograma com 25 artigos aptos aos critérios de seleção. Os resultados indicam que o aumento de problemas bucais em crianças com TEA partem da dificuldade de higienização oral por parte dos pais e cuidadores, somadas a falta de conhecimento sobre técnicas pedagógicas para facilitar os cuidados bucais e a desinformação sobre dieta cariogênica.

  • Open Access

    Manutenção da abertura bucal para otimização de ressonância magnética da articulação temporomandibular: proposta de um dispositivo

    by Luciana Paula Benício Arcas, Felipe Carlos Dias Arcas, Laís Regiane da Silva Concilio, Marina Amaral

  • Open Access

    Maintaining mouth opening to optimize magnetic resonance imaging of the temporomandibular joint: proposal for a new device

    by Luciana Paula Benício Arcas, Felipe Carlos Dias Arcas, Laís Regiane da Silva Concilio, Marina Amaral

  • Open Access

    Bond Strength and Surface Roughness of Two Ceramics After Metal Bracket Debonding

    by Luciana P.B. Arcas, Kusai Baroudi, Caroline A.B. de Matos, Fabiana C. Ribeiro, Laís R. Silva-Concílio, Marina Amaral

    Objective: The aims of this study were to compare the bond strength between metallic brackets and two different glass ceramics and to evaluate the ceramic surface roughness after different finishing protocols. Methods: The surface roughness of lithium disilicate and resin matrix ceramic samples was measured (initial). All samples were treated with hydrofluoric acid and silane and bonded to metallic brackets with orthodontic cement adhesive. Shear bond strength tests were performed using a universal testing machine (n=12). The surface roughness was measured again (intermediate, n=6) after removing the remaining cement adhesive from the ceramic surfaces with a diamond or 24-blade bur after polishing the ceramic surfaces (final, n=6). Results: The resin matrix ceramic had the highest bond strength. The rotatory instrument used for the removal of cement adhesive did not affect the surface roughness of the resin matrix ceramic or lithium disilicate (p=0.985 and p=0.504, respectively), but did affect the evaluation time (p<0.001) for both restorative materials. The intermediate roughness was the highest. For the resin matrix ceramic, polishing promoted a final surface roughness similar to the initial condition; however, changes in the surface shape of this ceramic could be visibly observed when using a 24-blade bur. Conclusion: The bond strength of metallic brackets bonded on resin-matrix ceramics is higher than bonding on lithium disilicate. The use of diamond burs for the removal of the remaining adhesive from the resin matrix ceramics is highly recommended.


  • Open Access

    Color Stability and Degree of Conversion of Light-cured Resin Cements

    by Ana Carolina Andreucci, Kusai Baroudi, Maiara Rodrigues Freitas, Marina Amaral, Flavio Baggio Aguiar, Rayssa Ferreira Zanatta, Priscila Christiane Suzy Liporoni

    Objective: To evaluate the color stability and degree of conversion of light-cured resin cement with different activator-initiator systems using LED lights with different wavelengths (polywave x monowave). Materials and Methods: Sixteen resin cement samples were made using a circular silicone matrix (7 mm diameter, 0.5 mm thickness) for each of the following tested materials: Variolink Esthetic LC (Ivoclar, color Light+); RelyX Veneer (3M ESPE, color A1); Filtek Z350XT flow resin (3M ESPE, color A1); Allcem Veneer APS (FGM, color A1); NX3 Light cure (Kerr, color A1). Half of the samples were photocured with a monowave LED light (Elipar Deep Cure), and the other half with a polywave LED light (Valo Grand). The initial color of each cement was measured using a high translucency ceramic sample simulating ceramic venner. Color measurements were performed with a reflectance colorimetric spectrophotometer and the data was collected according to the CIE L* a* b* system in two steps. The degree of conversion was measured using an infrared spectrometer by Fourier transform (FTIR / ATR) and the absorbance method. Statistical analysis was performed using ANOVA repeated measures and Tukey’s post hoc tests (p versus light curing (p = 0.084) and also related to time versus cement versus light curing (p = 0.142). Among the factors, there was only a statistically significant difference for the type of cement (p <0.01). In contrast, for the photocuring device (p = 0.504) and the interaction between them (p = 0.738), there was no significant difference. For the degree of conversion analysis, it showed a statistically significant difference for both factors, resin cements (p <0.01) and light curing units (p <0.01). Conclusion: The color stability of RelyX cement is low compared to other cements, while Variolink cement presented the best degree of the conversion value.


  • Effect of different fabrication methods of occlusal devices on periradicular stress distribution: A photoelastic analysis

    by Luciana Paula Benício Arcas, Kusai Baroudi, Laís Regiane Silva-Concílio, Cristiane Aparecida de Assis Claro, Marina Amaral