Andrew Yue
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew Yue has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
David M. Gilliam
National Institute of Standards and Technology, Physics Laboratory, Ionizing Radiation Division, Gaithersburg, MD, 20899-8461, USA
2 shared publicationsG.L. Greene
2 shared publications- Jere H. Jenkins
School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907, USA
2 shared publications M. Scott Dewey
National Institute of Standards and Technology, Physics Laboratory, Ionizing Radiation Division, Gaithersburg, MD, 20899-8461, USA
2 shared publications- Richard M. Lindstrom
National Institute of Standards and Technology
2 shared publications W.M. Snow
Indiana University, Bloomington, IN
2 shared publications
Latest Publications
- 1 July 2021
- Published by American Society of Clinical Oncology (ASCO) in JCO Oncology Practice
- Vol. 17 (7) , 379-381
Time to Rethink the Role of Clinical Pathways in the Era of Precision Medicine: A Lung Cancer Case Study
- 1 July 2021
- Published by American Society of Clinical Oncology (ASCO) in JCO Oncology Practice
- Vol. 17 (7) , 379-381
Time to Rethink the Role of Clinical Pathways in the Era of Precision Medicine: A Lung Cancer Case Study
- Top Cited Papers
- 27 November 2013
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 111 (22) , 222501
Improved Determination of the Neutron Lifetime
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of ${$\tau${}}_{n}=(886.3\ifmmode\pm\else\textpm\fi{}1.2[\mathrm{stat}]\ifmmode\pm\else\textpm\fi{}3.2[\mathrm{syst}])\text{ }\text{ }\mathrm{s}$. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized $^{6}\mathrm{Li}$ deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI $^{6}\mathrm{Li}(n,t)^{4}\mathrm{He}$ thermal neutron cross section. In the current work, we measure the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally absorbing neutron detector. This direct approach does not rely on the $^{6}\mathrm{Li}(n,t)^{4}\mathrm{He}$ cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but is measured with a precision of 0.057%, which represents a fivefold improvement in the uncertainty. We verify the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is ${$\tau${}}_{n}=(887.7\ifmmode\pm\else\textpm\fi{}1.2[\mathrm{stat}]\ifmmode\pm\else\textpm\fi{}1.9[\mathrm{syst}])\text{ }\text{ }\mathrm{s}$.- 27 November 2013
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 111 (22) , 222501
Top Cited PapersImproved Determination of the Neutron Lifetime
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of ${$\tau${}}_{n}=(886.3\ifmmode\pm\else\textpm\fi{}1.2[\mathrm{stat}]\ifmmode\pm\else\textpm\fi{}3.2[\mathrm{syst}])\text{ }\text{ }\mathrm{s}$. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized $^{6}\mathrm{Li}$ deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI $^{6}\mathrm{Li}(n,t)^{4}\mathrm{He}$ thermal neutron cross section. In the current work, we measure the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally absorbing neutron detector. This direct approach does not rely on the $^{6}\mathrm{Li}(n,t)^{4}\mathrm{He}$ cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but is measured with a precision of 0.057%, which represents a fivefold improvement in the uncertainty. We verify the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is ${$\tau${}}_{n}=(887.7\ifmmode\pm\else\textpm\fi{}1.2[\mathrm{stat}]\ifmmode\pm\else\textpm\fi{}1.9[\mathrm{syst}])\text{ }\text{ }\mathrm{s}$. - 2 August 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 299 (2) , 1061-1065
Improvements in the characterization of actinide targets by low solid-angle counting
- 2 August 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 299 (2) , 1061-1065
Improvements in the characterization of actinide targets by low solid-angle counting
- 1 December 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 659 (1) , 269-271
Absence of a self-induced decay effect in 198Au
- 1 December 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 659 (1) , 269-271
Absence of a self-induced decay effect in 198Au
- 1 October 2010
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 622 (1) , 93-96
Study of the dependence of 198Au half-life on source geometry
- 1 October 2010
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 622 (1) , 93-96
Study of the dependence of 198Au half-life on source geometry
- 1 December 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 611 (2-3) , 189-192
Prospects for a new cold neutron beam measurement of the neutron lifetime
- 1 December 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 611 (2-3) , 189-192
Prospects for a new cold neutron beam measurement of the neutron lifetime
- 1 December 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 611 (2-3) , 293-296
Systematic error in the precision measurement of the mean wavelength of a nearly monochromatic neutron beam due to geometric errors
- 1 December 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 611 (2-3) , 293-296
Systematic error in the precision measurement of the mean wavelength of a nearly monochromatic neutron beam due to geometric errors
- 1 August 2009
- Published by World Scientific Pub Co Pte Ltd
- p. 361-367
CALIBRATION OF A MANGANESE BATH RELATIVE TO 252Cf NU-BAR
- 1 August 2009
- Published by World Scientific Pub Co Pte Ltd
- p. 361-367
CALIBRATION OF A MANGANESE BATH RELATIVE TO 252Cf NU-BAR
- 1 June 2008
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 590 (1-3) , 181-184
The use of polyimide foils to prevent contamination from self-sputtering of 252Cf deposits in high-accuracy fission counting
- 1 June 2008
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 590 (1-3) , 181-184
The use of polyimide foils to prevent contamination from self-sputtering of 252Cf deposits in high-accuracy fission counting
- Open Access
- 1 May 2005
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 110 (3) , 161-8
Beamline performance simulations for the fundamental neutron physics beamline at the spallation neutron source
Monte Carlo simulations are being performed to design and characterize the neutron optics components for the two fundamental neutron physics beamlines at the Spallation Neutron Source. Optimization of the cold beamline includes characterization of the guides and benders, the neutron transmission through the 0.89 nm monochromator, and the expected performance of the four time-of-flight choppers. The locations and opening angles of the choppers have been studied using a simple spreadsheet-based analysis that was developed for other SNS chopper instruments. The spreadsheet parameters are then optimized using Monte Carlo techniques to obtain the results presented in this paper. Optimization of the 0.89 nm beamline includes characterizing the double crystal monochromator and the downstream guides. The simulations continue to be refined as components are ordered and their exact size and performance specifications are determined.
- 1 May 2005
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 110 (3) , 161-8
Open AccessBeamline performance simulations for the fundamental neutron physics beamline at the spallation neutron source
Monte Carlo simulations are being performed to design and characterize the neutron optics components for the two fundamental neutron physics beamlines at the Spallation Neutron Source. Optimization of the cold beamline includes characterization of the guides and benders, the neutron transmission through the 0.89 nm monochromator, and the expected performance of the four time-of-flight choppers. The locations and opening angles of the choppers have been studied using a simple spreadsheet-based analysis that was developed for other SNS chopper instruments. The spreadsheet parameters are then optimized using Monte Carlo techniques to obtain the results presented in this paper. Optimization of the 0.89 nm beamline includes characterizing the double crystal monochromator and the downstream guides. The simulations continue to be refined as components are ordered and their exact size and performance specifications are determined.