Kok Hooi Yap
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kok Hooi Yap has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Abdelrahmen Abdelbar
Department of Cardiothoracic Surgery, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL, UK
1 shared publication- Ahmed Abousteit
Department of Cardiothoracic Surgery, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL, UK
1 shared publication Alejandro Floh
The Labatt Family Heart Centre, The Hospital for Sick Children
1 shared publicationBoon Hean Ong
Department of Cardiothoracic Surgery, National Heart Centre Singapore, Singapore
1 shared publicationChong Tze Tec
National Heart Centre Singapore, Singapore
1 shared publicationChun‐Po Steve Fan
Peter Munk Cardiac Centre, University Health Network
1 shared publication
Latest Publications
- Open Access
- 6 May 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (9) , e037348
Are We Getting Better?: Ongoing Challenges of Atrioventricular Valve Repair in Children With Single Ventricle Physiology
Background: This study aimed to assess impact of atrioventricular valve (AVV) regurgitation onset, timing of AVV repair (AVVr), ventricular morphology, and era effect on AVVr outcomes in a single ventricle population. Methods: A retrospective review of 155 patients with single ventricle physiology who underwent AVVr between 1998 and 2022 was conducted. Transplant‐free survival, discharge alive, and AVV reoperation were assessed using the Kaplan–Meier survival method, stratified by the timing of AVVr (Group1 [G1], prebidirectional cavopulmonary shunt, N=33; G2, at or post‐shunt, N=93; G3, at or post‐Fontan, N=29). Cox proportional hazard models were used to assess the association of the timing of AVVr with death or transplant. Results: Transplant‐free survival at 10 years was lowest in G1 (G1, 16% [95% CI, 4%–35%]; G2, 65% [95% CI, 53%–74%]; G3, 85% [95% CI, 65%–94%], P P P =0.12). Meanwhile, the likelihood of discharge alive improved over the period in the entire cohort ( P P =0.02) and weight P P P <0.001), respectively. Conclusions: Patients with single ventricles who required AVVr, particularly before bidirectional cavopulmonary shunt, have poorer transplant‐free survival with no meaningful improvement over the past 2 decades. Small weight and morphologic right ventricle were strongly associated with increased mortality. Alternative treatment strategies should be considered for this high‐risk subgroup.
- 6 May 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (9) , e037348
Open AccessAre We Getting Better?: Ongoing Challenges of Atrioventricular Valve Repair in Children With Single Ventricle Physiology
Background: This study aimed to assess impact of atrioventricular valve (AVV) regurgitation onset, timing of AVV repair (AVVr), ventricular morphology, and era effect on AVVr outcomes in a single ventricle population. Methods: A retrospective review of 155 patients with single ventricle physiology who underwent AVVr between 1998 and 2022 was conducted. Transplant‐free survival, discharge alive, and AVV reoperation were assessed using the Kaplan–Meier survival method, stratified by the timing of AVVr (Group1 [G1], prebidirectional cavopulmonary shunt, N=33; G2, at or post‐shunt, N=93; G3, at or post‐Fontan, N=29). Cox proportional hazard models were used to assess the association of the timing of AVVr with death or transplant. Results: Transplant‐free survival at 10 years was lowest in G1 (G1, 16% [95% CI, 4%–35%]; G2, 65% [95% CI, 53%–74%]; G3, 85% [95% CI, 65%–94%], P P P =0.12). Meanwhile, the likelihood of discharge alive improved over the period in the entire cohort ( P P =0.02) and weight P P P <0.001), respectively. Conclusions: Patients with single ventricles who required AVVr, particularly before bidirectional cavopulmonary shunt, have poorer transplant‐free survival with no meaningful improvement over the past 2 decades. Small weight and morphologic right ventricle were strongly associated with increased mortality. Alternative treatment strategies should be considered for this high‐risk subgroup.
- Open Access
- 23 July 2022
- Published by Elsevier in Annals of Vascular Surgery - Brief Reports and Innovations
- Vol. 2 (3) , 100110
Multiorgan embolism from primary cardiac undifferentiated pleomorphic sarcoma – A case report and review of the literature
- 23 July 2022
- Published by Elsevier in Annals of Vascular Surgery - Brief Reports and Innovations
- Vol. 2 (3) , 100110
Open AccessMultiorgan embolism from primary cardiac undifferentiated pleomorphic sarcoma – A case report and review of the literature
- 1 July 2019
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 26 (5) , 732-735
Homemade Candy Plug Using a Zenith Alpha Thoracic Stent-Graft for False Lumen Distal Occlusion in Acute-on-Chronic Type B Aortic Dissection
Purpose: To report a candy-plug technique using a Zenith Alpha stent-graft to occlude the distal false lumen in a patient with a complicated chronic type B aortic dissection. Case Report: A 50-year-old male smoker presented with chest pain due to rapidly growing complicated chronic type B aortic dissection. Computed tomography angiography (CTA) showed the dissection extending from distal to the origin of the left subclavian artery (LSA) down to the left femoral artery. There was fusiform aneurysmal dilatation of the proximal descending aorta measuring up to 5.8 cm in diameter. He underwent left carotid–subclavian artery bypass, thoracic endovascular aortic repair with a Zenith Alpha stent-graft, a left common carotid artery chimney, and embolization of the proximal LSA. Serial CTA showed persistent false lumen flow. A decision was made to occlude the distal large false lumen using the candy-plug technique. A 44×125-mm Zenith Alpha stent-graft was used to prepare the candy plug. A gutter leak and a type Ia endoleak were embolized via a left brachial artery approach. At 2.5 years, imaging showed the candy plug in position, no endoleak, and the thrombosed false lumen in the thoracic aorta reduced in size. Conclusion: The candy-plug technique is useful in facilitating complete occlusion of the false lumen in chronic aortic dissection, which avoids an open procedure and the risk of higher morbidity.
- 1 July 2019
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 26 (5) , 732-735
Homemade Candy Plug Using a Zenith Alpha Thoracic Stent-Graft for False Lumen Distal Occlusion in Acute-on-Chronic Type B Aortic Dissection
Purpose: To report a candy-plug technique using a Zenith Alpha stent-graft to occlude the distal false lumen in a patient with a complicated chronic type B aortic dissection. Case Report: A 50-year-old male smoker presented with chest pain due to rapidly growing complicated chronic type B aortic dissection. Computed tomography angiography (CTA) showed the dissection extending from distal to the origin of the left subclavian artery (LSA) down to the left femoral artery. There was fusiform aneurysmal dilatation of the proximal descending aorta measuring up to 5.8 cm in diameter. He underwent left carotid–subclavian artery bypass, thoracic endovascular aortic repair with a Zenith Alpha stent-graft, a left common carotid artery chimney, and embolization of the proximal LSA. Serial CTA showed persistent false lumen flow. A decision was made to occlude the distal large false lumen using the candy-plug technique. A 44×125-mm Zenith Alpha stent-graft was used to prepare the candy plug. A gutter leak and a type Ia endoleak were embolized via a left brachial artery approach. At 2.5 years, imaging showed the candy plug in position, no endoleak, and the thrombosed false lumen in the thoracic aorta reduced in size. Conclusion: The candy-plug technique is useful in facilitating complete occlusion of the false lumen in chronic aortic dissection, which avoids an open procedure and the risk of higher morbidity.
- Open Access
- 1 January 2019
- Published by Korean Society of Echocardiography in Journal of Cardiovascular Imaging
- Vol. 27 (1) , 66-67
Large Thrombosed Right Coronary Artery Aneurysm Mimicking Right Atrial Mass
- 1 January 2019
- Published by Korean Society of Echocardiography in Journal of Cardiovascular Imaging
- Vol. 27 (1) , 66-67
Open AccessLarge Thrombosed Right Coronary Artery Aneurysm Mimicking Right Atrial Mass
- Open Access
- 1 June 2017
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 25 (5) , 822-826
The safe volume threshold for chest drain removal following pulmonary resection
A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was ‘In patients undergoing pulmonary resection, is there a safe drainage volume threshold for chest drain removal?’ Altogether 1054 papers were found, of which 5 papers represented the best evidence. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Chest drainage threshold, where used, ranged from 250 to 500 ml/day. Both randomized controlled trials showed no significant difference in reintervention rates with a higher chest drainage volume threshold. Four studies that performed analysis on other complications showed no statistical significant difference with a higher chest drainage volume threshold. Four studies evaluating length of hospital stay showed reduced or no difference in the length of stay with a higher chest drainage volume threshold. Two cohort studies reported the mortality rate of 0–0.01% with a higher chest drainage volume threshold. We conclude that early chest drain removal after pulmonary resection, accepting a higher chest drainage volume threshold of 250–500 ml/day is safe, and may result in shorter hospital stay without increasing reintervention, morbidity or mortality.
- 1 June 2017
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 25 (5) , 822-826
Open AccessThe safe volume threshold for chest drain removal following pulmonary resection
A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was ‘In patients undergoing pulmonary resection, is there a safe drainage volume threshold for chest drain removal?’ Altogether 1054 papers were found, of which 5 papers represented the best evidence. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Chest drainage threshold, where used, ranged from 250 to 500 ml/day. Both randomized controlled trials showed no significant difference in reintervention rates with a higher chest drainage volume threshold. Four studies that performed analysis on other complications showed no statistical significant difference with a higher chest drainage volume threshold. Four studies evaluating length of hospital stay showed reduced or no difference in the length of stay with a higher chest drainage volume threshold. Two cohort studies reported the mortality rate of 0–0.01% with a higher chest drainage volume threshold. We conclude that early chest drain removal after pulmonary resection, accepting a higher chest drainage volume threshold of 250–500 ml/day is safe, and may result in shorter hospital stay without increasing reintervention, morbidity or mortality.
- Open Access
- 12 December 2013
- Published by Wiley in International Journal of Vascular Medicine
- Vol. 2013, 1-13
Transcranial Doppler Ultrasound: A Review of the Physical Principles and Major Applications in Critical Care
Transcranial Doppler (TCD) is a noninvasive ultrasound (US) study used to measure cerebral blood flow velocity (CBF-V) in the major intracranial arteries. It involves use of low-frequency (≤2 MHz) US waves to insonate the basal cerebral arteries through relatively thin bone windows. TCD allows dynamic monitoring of CBF-V and vessel pulsatility, with a high temporal resolution. It is relatively inexpensive, repeatable, and portable. However, the performance of TCD is highly operator dependent and can be difficult, with approximately 10–20% of patients having inadequate transtemporal acoustic windows. Current applications of TCD include vasospasm in sickle cell disease, subarachnoid haemorrhage (SAH), and intra- and extracranial arterial stenosis and occlusion. TCD is also used in brain stem death, head injury, raised intracranial pressure (ICP), intraoperative monitoring, cerebral microembolism, and autoregulatory testing.
- 12 December 2013
- Published by Wiley in International Journal of Vascular Medicine
- Vol. 2013, 1-13
Open AccessTranscranial Doppler Ultrasound: A Review of the Physical Principles and Major Applications in Critical Care
Transcranial Doppler (TCD) is a noninvasive ultrasound (US) study used to measure cerebral blood flow velocity (CBF-V) in the major intracranial arteries. It involves use of low-frequency (≤2 MHz) US waves to insonate the basal cerebral arteries through relatively thin bone windows. TCD allows dynamic monitoring of CBF-V and vessel pulsatility, with a high temporal resolution. It is relatively inexpensive, repeatable, and portable. However, the performance of TCD is highly operator dependent and can be difficult, with approximately 10–20% of patients having inadequate transtemporal acoustic windows. Current applications of TCD include vasospasm in sickle cell disease, subarachnoid haemorrhage (SAH), and intra- and extracranial arterial stenosis and occlusion. TCD is also used in brain stem death, head injury, raised intracranial pressure (ICP), intraoperative monitoring, cerebral microembolism, and autoregulatory testing.
- Open Access
- 9 September 2013
- Published by Wiley in Case Reports in Surgery
- Vol. 2013, 1-3
Isolated Pulmonary Infective Endocarditis with Septic Pulmonary Embolism Complicating a Right Ventricular Outflow Tract Obstruction: Scarce and Devious Presentation
We present a case of a fifty-three-year-old male who presented with severe sepsis. He had been treated as a pneumonia patient for five months before the admission. Investigations revealed isolated pulmonary valve endocarditis and septic pulmonary embolism in addition to undiagnosed right ventricular outflow tract (RVOT) obstruction. The patient underwent surgery for the relief of RVOT obstruction by substantial muscle resection of the RVOT, pulmonary artery embolectomy, pulmonary valve replacement, and reconstruction of RVOT and main pulmonary artery with two separate bovine pericardial patches. He was discharged from our hospital after 6 weeks of intravenous antibiotics. He recovered well on follow-up 16 weeks after discharge. A high-suspicion index is needed to diagnose right-side heart endocarditis. Blood cultures and transesophageal echocardiogram are the key diagnostic tools.
- 9 September 2013
- Published by Wiley in Case Reports in Surgery
- Vol. 2013, 1-3
Open AccessIsolated Pulmonary Infective Endocarditis with Septic Pulmonary Embolism Complicating a Right Ventricular Outflow Tract Obstruction: Scarce and Devious Presentation
We present a case of a fifty-three-year-old male who presented with severe sepsis. He had been treated as a pneumonia patient for five months before the admission. Investigations revealed isolated pulmonary valve endocarditis and septic pulmonary embolism in addition to undiagnosed right ventricular outflow tract (RVOT) obstruction. The patient underwent surgery for the relief of RVOT obstruction by substantial muscle resection of the RVOT, pulmonary artery embolectomy, pulmonary valve replacement, and reconstruction of RVOT and main pulmonary artery with two separate bovine pericardial patches. He was discharged from our hospital after 6 weeks of intravenous antibiotics. He recovered well on follow-up 16 weeks after discharge. A high-suspicion index is needed to diagnose right-side heart endocarditis. Blood cultures and transesophageal echocardiogram are the key diagnostic tools.