Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Giovanni Brunaccini has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    LCOH optimization using price-responsive NLP techno-economic model formulation for HYDROGEN PRODUCTION: GREEN AND LOW CARBON CASE STUDIES

    by Gioacchino Musicò, Salvatore Gianluca Leonardi, Giovanni Lucà Trombetta, Davide Aloisio, Giovanni Brunaccini, Francesco Sergi

    The adoption of hydrogen represents a key lever for reducing CO2 emissions in hard-to-abate industries and in the power generation sector. Nevertheless, the high costs and infrastructure requirements associated with green hydrogen production remain major challenges. This study investigates how an optimized hydrogen production strategy can reduce the Levelized Cost of Hydrogen (LCOH), thereby directly lowering the operational expenditure related to electricity procurement. The analysis focuses on the optimization of a hydrogen production plant where two strategies were adopted: one considering electricity supplied from the grid (low-carbon hydrogen) and one from renewable energy sources (Green Hydrogen case). To assess the influence of local energy conditions, the same scenario was analyzed in three European regions (Italy, Spain, and Netherlands) where both grid electricity prices and solar resource availability differs significantly. This comparative approach makes possible to quantify how regional energy peculiarities impact the cost-effectiveness of hydrogen production. A Matlab-based simulation model was developed to perform the analysis and to ensure accurate, realistic system behaviour. The resulting insights identify the most cost-effective approaches for integrating hydrogen production into the energy value chain. Overall, the study emphasizes the advantages of flexible hydrogen production scheduling, leveraging dynamic electricity pricing and renewable energy availability to minimize operational costs while maximizing system efficiency. The model uses cost data coming from an industrial-scale electrolysis plant under development in Sicily within the framework of Hy2Market EU funded project, providing a realistic basis for investment assumptions.

  • Open Access

    Behind-the-Meter. Combination of Li-Ion Batteries and Organic Flow Redox Batteries for BTM Applications

    by Francesco Sergi, Giovanni Brunaccini, Elias Martinez, Sergio Costa, Davide Aloisio

    This work is focused on the development of a Hybrid Energy Storage System (HESS), constituted by the integration of a Lithium Titanate and Aqueous Organic Redox Flow battery systems. The HESS can provide several Behind-The-Meter services for energy management and efficient use. After an initial section dedicated to BTM services, the system and functionalities offered are deeply described, enhancing system exploitation within some case studies (in particular in an experimental site of Messina) with advantages and benefits offered by the hybrid architecture.

  • Open Access

    Securing Modbus in legacy industrial control systems: A decentralized approach using proxies, Post-Quantum Cryptography and Self-Sovereign Identity

    by Francesco Trungadi, Manuel Fabiano, Davide Aloisio, Giovanni Brunaccini, Francesco Sergi, Giovanni Merlino, Francesco Longo


  • An Energy Management System Capable of Microgrid Flexibility Evaluation to Support Demand Bidding

    by Marco Misia, Giuseppe La Tona, Antonino Sferlazza, Francesco Sergi, Giovanni Brunaccini, Davide Aloisio, Massimiliano Luna

    Demand Bidding (DB) is one of the programs that allow microgrid owners to provide Demand Response (DR). However, the DR bid formulation involves risks, such as technical infeasibility, cost ineffectiveness, and uncertainty on the actual DR service request. Furthermore, providing flexibility through load variations could be inconvenient. This paper proposes an Energy Management System (EMS) capable of microgrid flexibility evaluation to support DB. The EMS only leverages storage flexibility without changing the load profile. After computing the power flows that minimize the cash flow, it evaluates microgrid flexibility in terms of 1) possible deviations from the optimal profile of the power exchanged with the grid, and 2) the related incremental cost. This information allows microgrid owners to assess whether it is worth bidding for DR services and helps formulate the bid. Thus, the user is safeguarded from all the DB risks. The proposed technique is assessed considering the microgrid of an industrial hydrogen facility as a case study.

  • Proxy-Based Approach for Securing Modbus Communication with Post-quantum Cryptography: A Hydrogen-Based Smart Grid Case Study

    by Manuel Fabiano, Francesco Longo, Giovanni Merlino, Davide Aloisio, Giovanni Brunaccini, Francesco Sergi


  • Open Access

    Toward a Digital Twin of a Solid Oxide Fuel Cell Microcogenerator: Data-Driven Modelling

    by Tancredi Testasecca, Manfredi Picciotto Maniscalco, Giovanni Brunaccini, Girolama Airò Farulla, Giuseppina Ciulla, Marco Beccali, Marco Ferraro

    Solid oxide fuel cells (SOFC) could facilitate the green energy transition as they can produce high-temperature heat and electricity while emitting only water when supplied with hydrogen. Additionally, when operated with natural gas, these systems demonstrate higher thermoelectric efficiency compared to traditional microturbines or alternative engines. Within this context, although digitalisation has facilitated the acquisition of extensive data for precise modelling and optimal management of fuel cells, there remains a significant gap in developing digital twins that effectively achieve these objectives in real-world applications. Existing research predominantly focuses on the use of machine learning algorithms to predict the degradation of fuel cell components and to optimally design and theoretically operate these systems. In light of this, the presented study focuses on developing digital twin-oriented models that predict the efficiency of a commercial gas-fed solid oxide fuel cell under various operational conditions. This study uses data gathered from an experimental setup, which was employed to train various machine learning models, including artificial neural networks, random forests, and gradient boosting regressors. Preliminary findings demonstrate that the random forest model excels, achieving an R2 score exceeding 0.98 and a mean squared error of 0.14 in estimating electric efficiency. These outcomes could validate the potential of machine learning algorithms to support fuel cell integration into energy management systems capable of improving efficiency, pushing the transition towards sustainable energy solutions.


  • Open Access

    Optimal design of lithium ion battery thermal management systems based on phase change material at high current and high environmental temperature

    by Girolama Airò Farulla, Valeria Palomba, Davide Aloisio, Giovanni Brunaccini, Marco Ferraro, Andrea Frazzica, Francesco Sergi


  • Open Access

    A New Geographic Information System (GIS) Tool for Hydrogen Value Chain Planning Optimization: Application to Italian Highways

    by Alessandro Guzzini, Giovanni Brunaccini, Davide Aloisio, Marco Pellegrini, Cesare Saccani, Francesco Sergi

    Optimizing the hydrogen value chain is essential to ensure hydrogen market uptake in replacing traditional fossil fuel energy and to achieve energy system decarbonization in the next years. The design of new plants and infrastructures will be the first step. However, wrong decisions would result in temporal, economic losses and, in the worst case, failures. Because huge investments are expected, decision makers have to be assisted for its success. Because no tools are available for the optimum design and geographical location of power to gas (P2G) and power to hydrogen (P2H) plants, the geographic information system (GIS) and mathematical optimization approaches were combined into a new tool developed by CNR-ITAE and the University of Bologna in the SuperP2G project, aiming to support the interested stakeholders in the investigation and selection of the optimum size, location, and operations of P2H and P2G industrial plants while minimizing the levelized cost of hydrogen (LCOH). In the present study, the tool has been applied to hydrogen mobility, specifically to investigate the conversion of the existing refuelling stations on Italian highways to hydrogen refuelling stations (HRSs). Middle-term (2030) and long-term (2050) scenarios were investigated. In 2030, a potential demand of between 7000 and 10,000 tons/year was estimated in Italy, increasing to between 32,600 and 72,500 tons/year in 2050. The optimum P2H plant configuration to supply the HRS was calculated in different scenarios. Despite the optimization, even if the levelized cost of hydrogen (LCOH) reduces from 7.0–7.5 €/kg in 2030 to 5.6–6.2 €/kg in 2050, the results demonstrate that the replacement of the traditional fuels, i.e., gasoline, diesel, and liquefied petroleum gases (LPGs), will be disadvantaged without incentives or any other economic supporting schemes.


  • Open Access

    Hybrid Cascade Heat Pump and Thermal-Electric Energy Storage System for Residential Buildings: Experimental Testing and Performance Analysis

    by Valeria Palomba, Antonino Bonanno, Giovanni Brunaccini, Davide Aloisio, Francesco Sergi, Giuseppe E. Dino, Efstratios Varvaggiannis, Sotirios Karellas, Birgo Nitsch, Andreas Strehlow, et al.

    The need for innovative heating and cooling systems to decarbonize the building sector is widely recognized. It is especially important to increase the share of renewables at building level by maximizing self-consumption and reducing the primary energy demand. Accordingly, in the present paper, the results on a wide experimental campaign on a hybrid system are discussed. The system included a sorption module working as the topping cycle in a cascade configuration with a DC-driven vapor compression heat pump. A three-fluids heat exchanger with a phase change material (PCM), i.e., RT4 with nominal melting temperature of 4 °C, was installed on the evaporator side of the heat pump, for simultaneous operation as thermal storage and heat pumping purposes. The heat pump was connected to a DC-bus that included PV connection and electricity storage (batteries). Results showed that the energy efficiency of the heat pump in cascade operation was double compared to compression-only configuration and that, when simultaneously charging and discharging the latent storage in cascade configuration, no penalization in terms of efficiency compared to the compression-only configuration was measured. The self-sufficiency of the system was evaluated for three reference weeks in summer conditions of Athens climate and it was found that up to 100% of the electricity needed to drive the system could be self-produced for a modest cooling demand and up to 67% for the warmer conditions with high cooling demand.


  • Implementation of a Management System for Prosumer Energy Storage Scheduling in Smart Grids

    by Giovanni Artale, Giuseppe Caravello, Antonio Cataliotti, Valentina Cosentino, Salvatore Guaiana, Dario Di Cara, Nicola Panzavecchia, Giovanni Tine, Vincenzo Antonucci, Davide Aloisio, et al.

    Scheduling of energy storage systems of distributed generation is a key element for optimal renewable energy sources (RES) exploitation in smart grids, demand side response strategies implementation and prosumers interaction with Distribution System Operators (DSOs). In this context, this paper presents the implementation of a management system for energy storage scheduling, which allows taking appropriate account of the storage system behavior in real cases. To properly consider the real system operation, the employed battery model is modified, in order to include also the hysteresis phenomena in state of charge estimation in both charging and discharging operation. The validation of the proposed methodology is supported by experimental tests which allow comparing two different battery models. The obtained results show that better results can be obtained with the model including the hysteresis effect.