Shuji Kodama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuji Kodama has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
Atsushi Yamamoto
Department of Biological Chemistry, College of Bioscience and Biotechnology, Chubu University, 1200 Matsumoto-cho, Kasugai 487-8501, Japan
12 shared publicationsAtsushi Taga
Faculty of Pharmacy Kindai University Higashiosaka Japan
10 shared publicationsHiroyuki Terashima
GL Sciences Inc. Tokyo Japan
8 shared publicationsIkko Mikami
School of Science Tokai University Hiratsuka Japan
4 shared publicationsSen-Ichi Aizawa
Faculty of Engineering, University of Toyama, 3190 Gofuku, Toyama 930-8555, Japan
4 shared publicationsSen‐Ichi Aizawa
Faculty of Engineering University of Toyama Toyama Japan
4 shared publications
Latest Publications
- 2 October 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (12) , 1883-1892
Solid-phase extraction of ethyleneamines in river water prior to their determination by high-performance liquid chromatography with ultraviolet detection
A method based on solid-phase extraction (SPE) has been developed for the preconcentration of three kinds of ethyleneamines (EAs) [ethylenediamine (EDA), diethylenetriamine (DETA), and triethylenetetramine (TETA)] in river water for their high-performance liquid chromatographic (HPLC) determination by using on-line complexation with Cu(II) ion and ultraviolet (UV) detection. EAs, which are protonated in acidic and neutral conditions, could be concentrated by using cation-exchange SPE. However, inorganic cations and humic substances, often present in river water, interfered with this preconcentration. Inorganic cations, such as Ca and Mg ions, compete with EAs in cation-exchange processes. This interference could be reduced by masking them with ethylenediaminetetraacetic acid. Humic substances, such as humic acid and fluvic acid, seem to be due to the electrostatic interaction of EAs with them in the sample solution. This interference was reduced by passing the sample solution through an anion-exchange cartridge before the cation-exchange SPE. The interacted EAs remained in the anion-exchange cartridge; they could be eluted by washing out the anion-exchange cartridge with diluted HCl. In this washing process, although fulvic acid was eluted at the same time, it could be removed by passing the eluate through a reversed-phase cartridge connected in a series. After removing these interferences, EAs could be extraced with the cation-exchange SPE and quantitatively eluted by passing Cu(II) solution through the cartridge. The proposed method of including the HPLC–UV combined with the SPE was available for the determination of EAs in river water at concentrations as low as 0.015 µM for EDA and DETA and 0.05 µM for TETA. The high recoveries (83%–103%) and repeatabilities (RSD 1.2%–4.3%) were obtained for EAs from two river water samples spiked with two different concentrations of EAs. The proposed method was applied to analyses of river water samples taken from four rivers in Toyama Prefecture, Japan. Graphical Abstract
- 2 October 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (12) , 1883-1892
Solid-phase extraction of ethyleneamines in river water prior to their determination by high-performance liquid chromatography with ultraviolet detection
A method based on solid-phase extraction (SPE) has been developed for the preconcentration of three kinds of ethyleneamines (EAs) [ethylenediamine (EDA), diethylenetriamine (DETA), and triethylenetetramine (TETA)] in river water for their high-performance liquid chromatographic (HPLC) determination by using on-line complexation with Cu(II) ion and ultraviolet (UV) detection. EAs, which are protonated in acidic and neutral conditions, could be concentrated by using cation-exchange SPE. However, inorganic cations and humic substances, often present in river water, interfered with this preconcentration. Inorganic cations, such as Ca and Mg ions, compete with EAs in cation-exchange processes. This interference could be reduced by masking them with ethylenediaminetetraacetic acid. Humic substances, such as humic acid and fluvic acid, seem to be due to the electrostatic interaction of EAs with them in the sample solution. This interference was reduced by passing the sample solution through an anion-exchange cartridge before the cation-exchange SPE. The interacted EAs remained in the anion-exchange cartridge; they could be eluted by washing out the anion-exchange cartridge with diluted HCl. In this washing process, although fulvic acid was eluted at the same time, it could be removed by passing the eluate through a reversed-phase cartridge connected in a series. After removing these interferences, EAs could be extraced with the cation-exchange SPE and quantitatively eluted by passing Cu(II) solution through the cartridge. The proposed method of including the HPLC–UV combined with the SPE was available for the determination of EAs in river water at concentrations as low as 0.015 µM for EDA and DETA and 0.05 µM for TETA. The high recoveries (83%–103%) and repeatabilities (RSD 1.2%–4.3%) were obtained for EAs from two river water samples spiked with two different concentrations of EAs. The proposed method was applied to analyses of river water samples taken from four rivers in Toyama Prefecture, Japan. Graphical Abstract
- 23 February 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (6) , 885-890
Determination of iodide in concentrated chloride springs by reversed-phase high-performance liquid chromatography with ultraviolet detection
We developed a convenient and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method for analysis of iodide in concentrated chloride springs. Using a C18 column, the iodide and chloride peaks were well separated. Setting the wavelength at 240 nm allows direct ultraviolet (UV) detection of iodide without any UV or Schlieren effect due to the high chloride concentration. The high ionic strength of spring samples containing high levels of sodium chloride broadens the iodide peak. Iodide was quantified based on the peak areas of standard solutions of iodide, in which 100 mM sodium chloride was added to match the saline matrixes with the samples. The detection limit of iodide at a signal-to-noise ratio of 3 was 0.0003 mM. The detector response was linear over the concentration ranges of 0.001–0.1 mM. The proposed RP-HPLC/UV method was successfully applied to determine iodide in some concentrated chloride spring samples. Graphical abstract
- 23 February 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (6) , 885-890
Determination of iodide in concentrated chloride springs by reversed-phase high-performance liquid chromatography with ultraviolet detection
We developed a convenient and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method for analysis of iodide in concentrated chloride springs. Using a C18 column, the iodide and chloride peaks were well separated. Setting the wavelength at 240 nm allows direct ultraviolet (UV) detection of iodide without any UV or Schlieren effect due to the high chloride concentration. The high ionic strength of spring samples containing high levels of sodium chloride broadens the iodide peak. Iodide was quantified based on the peak areas of standard solutions of iodide, in which 100 mM sodium chloride was added to match the saline matrixes with the samples. The detection limit of iodide at a signal-to-noise ratio of 3 was 0.0003 mM. The detector response was linear over the concentration ranges of 0.001–0.1 mM. The proposed RP-HPLC/UV method was successfully applied to determine iodide in some concentrated chloride spring samples. Graphical abstract
- 21 June 2024
- Published by Springer Nature in Chromatographia
- Vol. 87 (7-8) , 463-470
Simultaneous Determination of Ethyleneamines by Reversed-Phase Ion-Pair Chromatography with Ultraviolet Detection Using on-Line Complexation with Copper(II) Ion
- 21 June 2024
- Published by Springer Nature in Chromatographia
- Vol. 87 (7-8) , 463-470
Simultaneous Determination of Ethyleneamines by Reversed-Phase Ion-Pair Chromatography with Ultraviolet Detection Using on-Line Complexation with Copper(II) Ion
- Open Access
- 17 April 2024
- Published by Wiley in Cancer Medicine
- Vol. 13 (8) , e7188
Impact of immune‐related adverse events on survival outcomes in extensive‐stage small cell lung cancer patients treated with immune checkpoint inhibitors
Background: Immune checkpoint inhibitors have recently become the standard of care in the first‐line treatment of extensive‐stage small cell lung cancer. Although immune‐related adverse events have been reported to influence prognosis in non‐small cell lung cancer patients, few studies have investigated the prognostic value of immune‐related adverse events in small cell lung cancer patients. In this study, we evaluated the prognosis of patients who developed immune‐related adverse events after first‐line treatment with immune checkpoint inhibitor‐based chemotherapy for extensive‐stage small cell lung cancer.Methods: We enrolled 90 patients with extensive‐stage small cell lung cancer who received immune checkpoint inhibitor‐based chemotherapy as first‐line treatment from September 2019 to December 2022 in six hospitals in Japan. The patients were categorized into groups with and without immune‐related adverse events.Results: There were 23 patients with and 67 without immune‐related adverse events. Seventeen patients had grade 1–2 immune‐related adverse events, and nine (including overlapping cases) had grade ≥3. The most frequent immune‐related adverse event was a skin rash. The median survival time was 22 months in patients with immune‐related adverse events and 9.3 months in patients without immune‐related adverse events. The hazard ratio was 0.40 (95% confidence interval: 0.19–0.83, p = 0.013).Conclusions: The results of this study show that immune‐related adverse events are associated with improved survival outcomes in patients with extensive‐stage small cell lung cancer.
- 17 April 2024
- Published by Wiley in Cancer Medicine
- Vol. 13 (8) , e7188
Open AccessImpact of immune‐related adverse events on survival outcomes in extensive‐stage small cell lung cancer patients treated with immune checkpoint inhibitors
Background: Immune checkpoint inhibitors have recently become the standard of care in the first‐line treatment of extensive‐stage small cell lung cancer. Although immune‐related adverse events have been reported to influence prognosis in non‐small cell lung cancer patients, few studies have investigated the prognostic value of immune‐related adverse events in small cell lung cancer patients. In this study, we evaluated the prognosis of patients who developed immune‐related adverse events after first‐line treatment with immune checkpoint inhibitor‐based chemotherapy for extensive‐stage small cell lung cancer.Methods: We enrolled 90 patients with extensive‐stage small cell lung cancer who received immune checkpoint inhibitor‐based chemotherapy as first‐line treatment from September 2019 to December 2022 in six hospitals in Japan. The patients were categorized into groups with and without immune‐related adverse events.Results: There were 23 patients with and 67 without immune‐related adverse events. Seventeen patients had grade 1–2 immune‐related adverse events, and nine (including overlapping cases) had grade ≥3. The most frequent immune‐related adverse event was a skin rash. The median survival time was 22 months in patients with immune‐related adverse events and 9.3 months in patients without immune‐related adverse events. The hazard ratio was 0.40 (95% confidence interval: 0.19–0.83, p = 0.013).Conclusions: The results of this study show that immune‐related adverse events are associated with improved survival outcomes in patients with extensive‐stage small cell lung cancer.
- 29 March 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1722, 464843
Separation of inorganic anions on reversed-phase C18 columns with a phosphomolybdate mobile phase
- 29 March 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1722, 464843
Separation of inorganic anions on reversed-phase C18 columns with a phosphomolybdate mobile phase
- Open Access
- 20 December 2023
- Published by Japan Lung Cancer Society in Haigan
- Vol. 63 (7) , 959-964
A Case of Treatment-resistant Extensive-disease Small-cell Lung Cancer with Multiple Liver Metastases Shrunk by Whole Liver Radiotherapy
背景.肝転移は小細胞肺癌で発生頻度が高く予後不良因子である.近年,海外を中心に肝臓への緩和照射の有用性が報告されているが,国内で報告例は少なく普及していない.症例.76歳男性.進展型小細胞肺癌に対し20XX-1年6月下旬からカルボプラチン+エトポシド+デュルバルマブ療法を開始,6コース完遂後にデュルバルマブ維持療法中だった.原発巣,肝転移,傍大動脈リンパ節転移の増大のため20XX年2月下旬に治療変更目的に入院した.Sensitive relapseと考えカルボプラチン+エトポシド療法を行ったが,背部痛と黄疸が出現し増強,オピオイドを開始した.多発肝転移増大に伴う被膜伸展症状であり疼痛緩和目的の全肝照射(21 Gy/7 fr)を行った.フレア現象で一過性疼痛増強がありオピオイドやステロイドを一時増量したが速やかに症状は軽快し独歩退院した.再入院しアムルビシン療法へ変更,全肝照射終了から約1か月時点で症状は軽快し多発肝転移も縮小している.結論.小細胞肺癌は放射線感受性が高く,低線量照射で効果が得られた.低線量では放射線肝障害が起こりにくく全肝照射は治療抵抗性の小細胞肺癌でも有用と考える.
- 20 December 2023
- Published by Japan Lung Cancer Society in Haigan
- Vol. 63 (7) , 959-964
Open AccessA Case of Treatment-resistant Extensive-disease Small-cell Lung Cancer with Multiple Liver Metastases Shrunk by Whole Liver Radiotherapy
背景.肝転移は小細胞肺癌で発生頻度が高く予後不良因子である.近年,海外を中心に肝臓への緩和照射の有用性が報告されているが,国内で報告例は少なく普及していない.症例.76歳男性.進展型小細胞肺癌に対し20XX-1年6月下旬からカルボプラチン+エトポシド+デュルバルマブ療法を開始,6コース完遂後にデュルバルマブ維持療法中だった.原発巣,肝転移,傍大動脈リンパ節転移の増大のため20XX年2月下旬に治療変更目的に入院した.Sensitive relapseと考えカルボプラチン+エトポシド療法を行ったが,背部痛と黄疸が出現し増強,オピオイドを開始した.多発肝転移増大に伴う被膜伸展症状であり疼痛緩和目的の全肝照射(21 Gy/7 fr)を行った.フレア現象で一過性疼痛増強がありオピオイドやステロイドを一時増量したが速やかに症状は軽快し独歩退院した.再入院しアムルビシン療法へ変更,全肝照射終了から約1か月時点で症状は軽快し多発肝転移も縮小している.結論.小細胞肺癌は放射線感受性が高く,低線量照射で効果が得られた.低線量では放射線肝障害が起こりにくく全肝照射は治療抵抗性の小細胞肺癌でも有用と考える.
- 31 January 2023
- Published by Wiley in Journal of Separation Science
- Vol. 46 (6) , e2200827
Direct chiral separation of abscisic acid by high‐performance liquid chromatography with a phenyl column and a mobile phase containing γ‐cyclodextrin
Abscisic acid (2‐cis,4‐trans‐abscisic acid) is a plant hormone that has an asymmetric carbon atom. We tried to separate the enantiomers of native abscisic acid by HPLC using a phenyl column and a chiral mobile phase containing γ‐cyclodextrin. The optimum mobile phase conditions were found to be 0.8% (w/v) γ‐cyclodextrin, 4% (v/v) acetonitrile, and 20 mM phosphate buffer (pH 6.0). It was found that (R)‐abscisic acid was earlier detected than (S)‐abscisic acid. Since γ‐cyclodextrin is hardly retained on a phenyl column, it was suggested that (R)‐abscisic acid formed a more stable complex with γ‐cyclodextrin than the (S)‐abscisic acid. Abscisic acid in an acacia honey sample was successfully enantioseparated with the proposed method and only (S)‐abscisic acid was detected. A biologically inactive 2‐trans,4‐trans‐abscisic acid, which was prepared by irradiation of abscisic acid with a light‐emitting diode lamp at 365 nm, was partially enantioseparated by the proposed method. Since the irradiation of (S)‐abscisic acid‐induced cis‐to‐trans isomerization to produce one 2‐trans,4‐trans‐abscisic acid enantiomer, it is reasonable that racemization did not proceed during the cis‐to‐trans isomerization. (S)‐Abscisic acid and probably (S)‐2‐trans,4‐trans‐abscisic acid were detected in a honey sample, where the peak area of (S)‐abscisic acid was 7 times larger than that of (S)‐2‐trans,4‐trans‐abscisic acid.
- 31 January 2023
- Published by Wiley in Journal of Separation Science
- Vol. 46 (6) , e2200827
Direct chiral separation of abscisic acid by high‐performance liquid chromatography with a phenyl column and a mobile phase containing γ‐cyclodextrin
Abscisic acid (2‐cis,4‐trans‐abscisic acid) is a plant hormone that has an asymmetric carbon atom. We tried to separate the enantiomers of native abscisic acid by HPLC using a phenyl column and a chiral mobile phase containing γ‐cyclodextrin. The optimum mobile phase conditions were found to be 0.8% (w/v) γ‐cyclodextrin, 4% (v/v) acetonitrile, and 20 mM phosphate buffer (pH 6.0). It was found that (R)‐abscisic acid was earlier detected than (S)‐abscisic acid. Since γ‐cyclodextrin is hardly retained on a phenyl column, it was suggested that (R)‐abscisic acid formed a more stable complex with γ‐cyclodextrin than the (S)‐abscisic acid. Abscisic acid in an acacia honey sample was successfully enantioseparated with the proposed method and only (S)‐abscisic acid was detected. A biologically inactive 2‐trans,4‐trans‐abscisic acid, which was prepared by irradiation of abscisic acid with a light‐emitting diode lamp at 365 nm, was partially enantioseparated by the proposed method. Since the irradiation of (S)‐abscisic acid‐induced cis‐to‐trans isomerization to produce one 2‐trans,4‐trans‐abscisic acid enantiomer, it is reasonable that racemization did not proceed during the cis‐to‐trans isomerization. (S)‐Abscisic acid and probably (S)‐2‐trans,4‐trans‐abscisic acid were detected in a honey sample, where the peak area of (S)‐abscisic acid was 7 times larger than that of (S)‐2‐trans,4‐trans‐abscisic acid.
- Open Access
- 4 January 2022
- Published by Springer Nature in Cureus
- Vol. 14 (1) , e20939
Radiation Therapy for Malignant Lumbosacral Plexopathy: A Case Series
Malignant lumbosacral plexopathy is caused by a direct extension of an intrapelvic malignancy to involve the plexus nerves. In this report, we describe the effect of radiotherapy on patients with malignant lumbosacral plexopathy. We performed a retrospective review of the medical records of patients who underwent radiation therapy for pain caused by malignant lumbosacral plexopathy between 2017 and 2020 at our institution. The pain was measured using a numeric rating scale (0-10) at initiation and completion of radiotherapy or at the time when the maximum response was observed. A total of 12 tumor sites in 11 patients were included. Eight of the tumors invaded the iliopsoas muscle, and the remaining four invaded or abutted the piriformis muscle. The mean duration of follow-up was 215 days (31-675 days). All patients achieved pain relief at the end of radiotherapy, with complete resolution of pain in nine patients. The maximum effect was seen at a mean of three weeks (1-12 weeks) after the initiation of radiotherapy. Toxicities related to radiotherapy included grade 1 diarrhea in four patients and grade 1 frequent urination in one patient. Two patients experienced a relapse of pain at one and two months, respectively, after achieving their maximal response. Radiotherapy provides significant pain relief for patients with the malignant lumbosacral syndrome. The recognition and diagnosis of this syndrome, and the use of radiation therapy as a therapeutic option, are important. Patients should be offered all possible therapies, regardless of curative or palliative intent.
- 4 January 2022
- Published by Springer Nature in Cureus
- Vol. 14 (1) , e20939
Open AccessRadiation Therapy for Malignant Lumbosacral Plexopathy: A Case Series
Malignant lumbosacral plexopathy is caused by a direct extension of an intrapelvic malignancy to involve the plexus nerves. In this report, we describe the effect of radiotherapy on patients with malignant lumbosacral plexopathy. We performed a retrospective review of the medical records of patients who underwent radiation therapy for pain caused by malignant lumbosacral plexopathy between 2017 and 2020 at our institution. The pain was measured using a numeric rating scale (0-10) at initiation and completion of radiotherapy or at the time when the maximum response was observed. A total of 12 tumor sites in 11 patients were included. Eight of the tumors invaded the iliopsoas muscle, and the remaining four invaded or abutted the piriformis muscle. The mean duration of follow-up was 215 days (31-675 days). All patients achieved pain relief at the end of radiotherapy, with complete resolution of pain in nine patients. The maximum effect was seen at a mean of three weeks (1-12 weeks) after the initiation of radiotherapy. Toxicities related to radiotherapy included grade 1 diarrhea in four patients and grade 1 frequent urination in one patient. Two patients experienced a relapse of pain at one and two months, respectively, after achieving their maximal response. Radiotherapy provides significant pain relief for patients with the malignant lumbosacral syndrome. The recognition and diagnosis of this syndrome, and the use of radiation therapy as a therapeutic option, are important. Patients should be offered all possible therapies, regardless of curative or palliative intent.
- 2 June 2021
- Published by Wiley in Journal of Separation Science
- Vol. 44 (15) , 2932-2940
Enantioseparation of phenethylamines by using high‐performance liquid chromatography column permanently coated with methylated β‐cyclodextrin
Cyclodextrins and their derivatives have been used for chiral high‐performance liquid chromatography selectors, while they are costly to use as mobile phase additives in high‐performance liquid chromatography. Here, we report application of phenyl column coated permanently with methylated β‐cyclodextrin for chiral high‐performance liquid chromatography. A 0.1% (v/v) phosphoric acid solution containing 1 M NaCl and 0.5% (w/v) methylated β‐cyclodextrin was subjected to a phenyl column at a flow rate of 0.5 mL/min at 30°C for 2 h. Using the precoating phenyl column, all the enantiomers of the four phenethylamines (norepinephrine, epinephrine, octopamine, and synephrine) were successfully separated simultaneously by high‐performance liquid chromatography with a mobile phase without methylated β‐cyclodextrin at a flow rate of 0.2 mL/min at 30°C. The enantioseparation ability was retained for successive analyses during 1 week. It is suggested that inclusion complex of methylated β‐cyclodextrin with a phenyl group on the surface of the stationary phase could be formed and that the inclusion complex could form the ternary complex with the injected analytes. The longer retention time of (S)‐enantiomers of analytes than corresponding (R)‐enantiomers for high‐performance liquid chromatography could be explained from the higher stability of the methylated β‐cyclodextrin complexes with (S)‐enantiomers, which were confirmed by capillary electrophoresis and 1H NMR spectroscopy experiments.
- 2 June 2021
- Published by Wiley in Journal of Separation Science
- Vol. 44 (15) , 2932-2940
Enantioseparation of phenethylamines by using high‐performance liquid chromatography column permanently coated with methylated β‐cyclodextrin
Cyclodextrins and their derivatives have been used for chiral high‐performance liquid chromatography selectors, while they are costly to use as mobile phase additives in high‐performance liquid chromatography. Here, we report application of phenyl column coated permanently with methylated β‐cyclodextrin for chiral high‐performance liquid chromatography. A 0.1% (v/v) phosphoric acid solution containing 1 M NaCl and 0.5% (w/v) methylated β‐cyclodextrin was subjected to a phenyl column at a flow rate of 0.5 mL/min at 30°C for 2 h. Using the precoating phenyl column, all the enantiomers of the four phenethylamines (norepinephrine, epinephrine, octopamine, and synephrine) were successfully separated simultaneously by high‐performance liquid chromatography with a mobile phase without methylated β‐cyclodextrin at a flow rate of 0.2 mL/min at 30°C. The enantioseparation ability was retained for successive analyses during 1 week. It is suggested that inclusion complex of methylated β‐cyclodextrin with a phenyl group on the surface of the stationary phase could be formed and that the inclusion complex could form the ternary complex with the injected analytes. The longer retention time of (S)‐enantiomers of analytes than corresponding (R)‐enantiomers for high‐performance liquid chromatography could be explained from the higher stability of the methylated β‐cyclodextrin complexes with (S)‐enantiomers, which were confirmed by capillary electrophoresis and 1H NMR spectroscopy experiments.