Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas Wendler has a total of 349 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spatio-Temporal Lesion Graphs: A Graph-Based Framework for Tracking Topology Changes in Longitudinal Oncologic Imaging

    by Lukas Förner, Maximilian Schmutz, Rainer Claus, Constantin Lapa, Thomas Wendler

    Longitudinal oncologic imaging poses a tracking challenge because lesions can split, merge, or transiently disappear, violating one-to-one correspondence assumptions. We propose spatio-temporal lesion graphs constructed via nearest-centroid matching across all previous time points for lineage assignment, with bidirectional matching between consecutive scans to classify splits, merges, and continuations without learning. Modality-agnostic matching naturally captures phenotypic switching across imaging different modalities. Evaluated on longitudinal PSMA-/FDG-PET/CT during 177Lu-PSMA therapy (4 patients, 11-13 scans each), the graphs recovered 50 topology changes (22 splits, 28 merges) missed by forward-only matching and revealed persistently high intra-patient SUVpeak heterogeneity (median CV=0.74), demonstrating that aggregate metrics obscure substantial inter-lesion variation. The resulting graph provides a compact lesion-level representation for response assessment and potentially lesion-specific diagnostics and local therapy. The code and data are available at: https://github.com/lukasf98/spatio-temporal-graph.

  • Open Access

    Tomographic 3D Ultrasound for Thyroid Volumetry—A Comparison Between Multiplanar 2D and 3D Imaging Methods

    by Robert Roth, Zoe Reinke, Martin Siedlecki, Jan Luitjens, Martin Hügle, Johanna S. Enke, Christian Liska, Laura-Marie Feitelson, Constantin Lapa, Thomas Kroencke, et al.

    Background: Accurate thyroid volume measurement is essential for diagnosing and monitoring thyroid disorders and for determining radioiodine therapy dosage. The ellipsoid method applied to two-dimensional B-mode ultrasound (Bmode-2D-US) is the most prevalent clinical approach, yet it is known to suffer from high observer dependence and limited accuracy. Tracked three-dimensional ultrasound (3D-US) is a promising radiation-free alternative, but direct comparisons across modalities under controlled conditions remain scarce. Methods: A custom-built anthropomorphic multi-modality phantom was constructed containing six anatomically realistic thyroid lobe samples molded from segmented MRI data, with ground truth volumes verified by the suspension method and 3D surface scanning. Volume measurements were performed by six observers of varying experience using Bmode-2D-US, electromagnetically tracked 3D-US (EM-3D-US), inertial-measurement-unit-tracked 3D-US (IMU-3D-US), and optically tracked 3D-US (Opt-3D-US), as well as computed tomography (CT) and magnetic resonance imaging (MRI). Inter- and intraobserver variability were assessed using modified Bland–Altman analysis. Results: All three 3D-US methods reduced inter- and intraobserver variability compared to Bmode-2D-US, achieving variability comparable to CT and lower than MRI. Mean accuracy was similar across 3D-US, CT, and MRI. Bmode-2D-US showed strong observer dependence, with operator experience having the most pronounced effect on this method. Among tracked methods, EM-3D-US and Opt-3D-US were least sensitive to operator movement quality, while IMU-3D-US showed somewhat higher sensitivity. Conclusions: Tracked 3D-US is a promising radiation-free alternative to conventional Bmode-2D-US for thyroid volumetry, offering improved reproducibility and accuracy across operators of varying experience in this phantom-based evaluation.

  • Open Access

    Tomographic 3D Ultrasound for Thyroid Volumetry—A Comparison Between Multiplanar 2D and 3D Imaging Methods

    by Robert Roth, Zoe Reinke, Martin Siedlecki, Jan Luitjens, Martin Hügle, Johanna S. Enke, Christian Liska, Laura-Marie Feitelson, Constantin Lapa, Thomas Kröncke, et al.

    Background: Accurate thyroid volume measurement is essential for diagnosing and monitoring thyroid disorders and for determining radioiodine therapy dosage. The ellipsoid method applied to two-dimensional B-mode ultrasound (Bmode-2D-US) is the most prevalent clinical approach, yet it is known to suffer from high observer dependence and limited accuracy. Tracked three-dimensional ultrasound (3D-US) is a promising radiation-free alternative, but direct comparisons across modalities under controlled conditions remain scarce. Methods: A custom-built anthropomorphic multi-modality phantom was constructed containing six anatomically realistic thyroid lobe samples molded from segmented MRI data, with ground truth volumes verified by the suspension method and 3D surface scanning. Volume measurements were performed by six observers of varying experience using Bmode-2D-US, electromagnetically tracked 3D-US (EM-3D-US), inertial-measurement-unit tracked 3D-US (IMU-3D-US), and optically tracked 3D-US (Opt-3D-US), as well as computed tomography (CT) and magnetic resonance imaging (MRI). Inter- and intraobserver variability were assessed using modified Bland-Altman analysis. Results: All three 3D-US methods reduced inter- and intraobserver variability compared to Bmode-2D-US, achieving variability comparable to CT and lower than MRI. Mean accuracy was similar across 3D-US, CT, and MRI. Bmode-2D-US showed strong observer dependence, with operator experience having the most pronounced effect on this method. Among tracked methods, EM-3D-US and Opt-3D-US were least sensitive to operator movement quality, while IMU-3D-US showed somewhat higher sensitivity. Conclusion: Tracked 3D-US is a promising radiation-free alternative to conventional Bmode-2D-US for thyroid volumetry, offering improved reproducibility and accuracy across operators of varying experience.

  • Open Access

    Redefining robotic image-guidance – tomographic visualization of lesions during prostate cancer surgery via gantry-free robotic SPECT

    by A. C. Berrens, K. Pirkovets, S. Azargoshasb, L. J. Slof, B. A. Cakal, P. J. van Leeuwen, E. M. K. Wit, M. Sinaasappel, T. Wendler, H. G. van der Poel, et al.

    Purpose: The introduction of the drop-in gamma probe has advanced intraoperative molecular imaging during prostate cancer surgery. We have been able to convert the sensor’s numeric readout to tomographic images, so-called robotic-SPECT ( Robo SPECT) and investigate how this is impacted by radiopharmaceutical avidities and drop-in scan metrics. Methods: The gamma sensor readout was registered with its 3D position and orientation, allowing a custom reconstruction algorithm to generate Robo SPECT images. Evaluations occurred in 21 patients; 10 sentinel node procedures (SN; primary prostate cancer) and 11 PSMA-radioguided surgery (recurrent prostate cancer). Robo SPECT findings were related to respective pre- and intra-operative controls, including preoperative PSMA-PET/CT and/or SPECT/CT images and fluorescence detection (SN only). Results: Robo SPECT proved to be safe and applicable in a range of conditions. In the SN-group, 26 SN-SPECT/CT lesions were successfully identified with SN- Robo SPECT (100%); 3 were tumor positive (sensitivity 100%). Only 73% of SNs were surgically visible with fluorescence imaging. For the PSMA guided group, the 14 lesions identified on PSMA-PET/CT were all visualized with PSMA- Robo SPECT (100%); 18 specimens were tumor positive (sensitivity 78% for both PSMA-PET/CT and PSMA- Robo SPECT). Preoperative PSMA-SPECT/CT only identified 4 PSMA-lesions (29%). No false positives were seen for robo SPECT and all final resection margins were clean. At 6-months 0% of the SN-patients and 20% of PSMA-patients showed biochemical recurrence. Conclusion: Robo SPECT provides 3D context that extends the utility of drop-in gamma tracing and assists the alignment between pre- and intra-operative target perception. Here SN- Robo SPECT clearly outperformed fluorescence SN imaging and PSMA- Robo SPECT outperformed preoperative PSMA-SPECT/CT imaging.


  • Beyond the LUMIR challenge: The pathway to foundational registration models

    by Junyu Chen, Shuwen Wei, Joel Honkamaa, Pekka Marttinen, Hang Zhang, Min Liu, Yichao Zhou, Zuopeng Tan, Zhuoyuan Wang, Yi Wang, et al.


  • Open Access

    Applications of artificial intelligence in nuclear medicine

    by Lena Kaiser, Thomas Wendler, Deni Hardiansyah, Dirk Hellwig, Philipp Lohmann, Stephan Nekolla, Laszlo Papp, Philipp Ritt, Lalith Kumar Shiyam Sundar, Johannes Tran-Gia, et al.


  • Open Access

    Abstract: Bone-guided Semi-supervised Registration

    by Lukas Förner, Thomas Wendler

  • Label, Refine, Repeat

    by Nico Schmutzenhofer, Lukas Förner, Sina Wendrich, Kartikay Tehlan, Thomas Wendler

  • AI-based Automated Framework for Quantitative PET/CT Image Analysis

    by Sonja Adomeit, Lukas Förner, Elisabeth Scheurer, Jan Bäßler, Elina Gastreich de Llanes, Jonas Böhringer, Ralph A. Bundschuh, Constantin Lapa, Kartikay Tehlan, Thomas Wendler