Ehsan Bahrampour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ehsan Bahrampour has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Elham Soltanimehr
Department of Pediatric Dentistry, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
3 shared publications - Marzieh Moattari
Faculty of Nursing and Midwifery, Shiraz University of Medical Sciences, Shiraz, Iran
3 shared publications - Ali Zamani
Department of Medical Physics and Biomedical Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
2 shared publications - Mohammad Moslem Imani
Department of Orthodontics, School of Dentistry, Kermanshah University of Medical Sciences, Kermanshah, Islamic Republic of Iran
2 shared publications - Shoaleh Shahidi
Biomaterial Research Center, Department of Oral and Maxillofacial Radiology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
2 shared publications - Alireza Mehdizadeh
Ionizing and Non-ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran
1 shared publication
Latest Publications
- Open Access
- 28 June 2019
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 56 (2) , 155-159
Comparative evaluation of the efficacy of three methods of delivering calcium hydroxide into the root canal
Calcium hydroxide, due to its favorable properties, such as an antimicrobial effect as well as its ability to dissolve necrotic tissues, inhibit tooth resorption and stimulate the formation of a hard tissue barrier, is widely used in root canal treatment. The objective of this study was to compare the efficacy of 3 methods of delivery of calcium hydroxide into the canals. This in vitro experimental study was performed on acrylic resin blocks with simulated curved canals (curvature of 24° and 44°). Calcium hydroxide was delivered into the canals with 3 different instruments : a hand file, a Lentulo and a rotary file. The data was analyzed using the three-way analysis of variance (ANOVA) and Tukey's test. The density of calcium hydroxide was significantly different among the 3 groups (p < 0.001). The manual delivery technique resulted in the lowest and using a rotary file in the highest density of calcium hydroxide (p < 0.001). The mean density of calcium hydroxide was significantly higher in the canals with curvature of 24°, irrespective of the delivery method (p < 0.001). The lowest mean density of calcium hydroxide was noted at 1 mm and 3 mm from the apex, whereas the highest mean density was noted at 11 mm from the apex, irrespective of delivery method (p < 0.001). A rotary file seems to be the most efficient instrument for delivering calcium hydroxide into the canals, especially into the apical region of canals with greater curvature.
- 28 June 2019
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 56 (2) , 155-159
Open AccessComparative evaluation of the efficacy of three methods of delivering calcium hydroxide into the root canal
Calcium hydroxide, due to its favorable properties, such as an antimicrobial effect as well as its ability to dissolve necrotic tissues, inhibit tooth resorption and stimulate the formation of a hard tissue barrier, is widely used in root canal treatment. The objective of this study was to compare the efficacy of 3 methods of delivery of calcium hydroxide into the canals. This in vitro experimental study was performed on acrylic resin blocks with simulated curved canals (curvature of 24° and 44°). Calcium hydroxide was delivered into the canals with 3 different instruments : a hand file, a Lentulo and a rotary file. The data was analyzed using the three-way analysis of variance (ANOVA) and Tukey's test. The density of calcium hydroxide was significantly different among the 3 groups (p < 0.001). The manual delivery technique resulted in the lowest and using a rotary file in the highest density of calcium hydroxide (p < 0.001). The mean density of calcium hydroxide was significantly higher in the canals with curvature of 24°, irrespective of the delivery method (p < 0.001). The lowest mean density of calcium hydroxide was noted at 1 mm and 3 mm from the apex, whereas the highest mean density was noted at 11 mm from the apex, irrespective of delivery method (p < 0.001). A rotary file seems to be the most efficient instrument for delivering calcium hydroxide into the canals, especially into the apical region of canals with greater curvature.
- Top Cited PapersOpen Access
- 25 June 2019
- Published by Springer Nature in BMC Medical Education
- Vol. 19 (1) , 1-7
Effect of virtual versus traditional education on theoretical knowledge and reporting skills of dental students in radiographic interpretation of bony lesions of the jaw
This study aimed to compare the effect of virtual and traditional education on theoretical knowledge and reporting skills of dental students in radiographic interpretation of bony lesions of the jaw. This experimental study evaluated 39 dental students who had not received any instruction regarding radiographic interpretation of bony lesions of the jaw. They were randomly divided into two groups of virtual (n = 20) and traditional education (n = 19) and matched in terms of their grade point average (GPA). The virtual group received a virtual learning package while the traditional group received traditional classroom instruction for 6 one-hour sessions. Similar contents were taught to both groups by the same mentor. All students participated in a theoretical test with multiple-choice questions and an objective structured clinical examination (OSCE). Similar exams were also held 2 months later to assess knowledge retention. Data were analyzed using independent sample t-test and repeated measures ANOVA. The mean scores of theoretical test (P < 0.05) and OSCE (P > 0.05) in the virtual education group (16.60 ± 0.91 and 15.13 ± 0.78) were higher than those in the traditional education group (14.89 ± 0.99 and 14.71 ± 0.92). In both methods of instruction, the mean scores of theoretical test and OSCE at 2 months were lower than the scores acquired immediately after instruction but this difference was not statistically significant (P > 0.05). Type of education had a significant effect on the theoretical test score (P < 0.001) but had no significant effect on the clinical score (P = 0.072). Virtual learning was superior to traditional lecture-based method for enhancement of knowledge acquisition in radiographic interpretation of bony lesions of the jaw. However, to improve our students’ reporting skills, we need to revise our virtual educational program so that the students have more opportunities to engage in reporting skills.
- 25 June 2019
- Published by Springer Nature in BMC Medical Education
- Vol. 19 (1) , 1-7
Top Cited PapersOpen AccessEffect of virtual versus traditional education on theoretical knowledge and reporting skills of dental students in radiographic interpretation of bony lesions of the jaw
This study aimed to compare the effect of virtual and traditional education on theoretical knowledge and reporting skills of dental students in radiographic interpretation of bony lesions of the jaw. This experimental study evaluated 39 dental students who had not received any instruction regarding radiographic interpretation of bony lesions of the jaw. They were randomly divided into two groups of virtual (n = 20) and traditional education (n = 19) and matched in terms of their grade point average (GPA). The virtual group received a virtual learning package while the traditional group received traditional classroom instruction for 6 one-hour sessions. Similar contents were taught to both groups by the same mentor. All students participated in a theoretical test with multiple-choice questions and an objective structured clinical examination (OSCE). Similar exams were also held 2 months later to assess knowledge retention. Data were analyzed using independent sample t-test and repeated measures ANOVA. The mean scores of theoretical test (P < 0.05) and OSCE (P > 0.05) in the virtual education group (16.60 ± 0.91 and 15.13 ± 0.78) were higher than those in the traditional education group (14.89 ± 0.99 and 14.71 ± 0.92). In both methods of instruction, the mean scores of theoretical test and OSCE at 2 months were lower than the scores acquired immediately after instruction but this difference was not statistically significant (P > 0.05). Type of education had a significant effect on the theoretical test score (P < 0.001) but had no significant effect on the clinical score (P = 0.072). Virtual learning was superior to traditional lecture-based method for enhancement of knowledge acquisition in radiographic interpretation of bony lesions of the jaw. However, to improve our students’ reporting skills, we need to revise our virtual educational program so that the students have more opportunities to engage in reporting skills.
- Open Access
- 19 June 2019
- Published by Springer Nature in BMC Oral Health
- Vol. 19 (1) , 1-9
Efficacy of diode and CO2 lasers along with calcium and fluoride-containing compounds for the remineralization of primary teeth
- 19 June 2019
- Published by Springer Nature in BMC Oral Health
- Vol. 19 (1) , 1-9
Open AccessEfficacy of diode and CO2 lasers along with calcium and fluoride-containing compounds for the remineralization of primary teeth
- 26 February 2018
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 55 (7) , 919-924
Cone Beam Computed Tomographic Evaluation of Mandibular Asymmetry in Patients with Cleft Lip and Palate
Objective: The purpose of the present study was to compare mandibular vertical asymmetry in patients with unilateral and bilateral cleft lip and palate and subjects with normal occlusion. Materials and Methods: Cone beam computed tomography scans of three groups consisting of 20 patients with unilateral cleft lip and palate, 20 patients affected by bilateral cleft lip and palate, and a control group of 20 subjects with normal occlusion were analyzed for this study. Condylar, ramal, and condylar plus ramal asymmetry indices were measured for all subjects using the method of Habets et al. Kruskal-Wallis and Mann-Whitney tests were used to determine any significant differences between the groups for all indices at the 95% level of confidence. Results: There were no significant differences regarding sex for all mandibular asymmetry indices in all three groups. All Asymmetry indices (condylar, ramal, and condylar plus ramal asymmetry) were significantly higher in the unilateral cleft group compared with the other two groups. Conclusion: Cone beam computed tomography images showed that patients with cleft lip and palate suffered from mandibular asymmetry. Subjects with unilateral cleft lip and palate had a more asymmetric mandible compared with the bilateral cleft lip and palate and control groups. Therefore, the mandible appears to be the leading factor in facial asymmetry in subjects with unilateral cleft lip and palate.
- 26 February 2018
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 55 (7) , 919-924
Cone Beam Computed Tomographic Evaluation of Mandibular Asymmetry in Patients with Cleft Lip and Palate
Objective: The purpose of the present study was to compare mandibular vertical asymmetry in patients with unilateral and bilateral cleft lip and palate and subjects with normal occlusion. Materials and Methods: Cone beam computed tomography scans of three groups consisting of 20 patients with unilateral cleft lip and palate, 20 patients affected by bilateral cleft lip and palate, and a control group of 20 subjects with normal occlusion were analyzed for this study. Condylar, ramal, and condylar plus ramal asymmetry indices were measured for all subjects using the method of Habets et al. Kruskal-Wallis and Mann-Whitney tests were used to determine any significant differences between the groups for all indices at the 95% level of confidence. Results: There were no significant differences regarding sex for all mandibular asymmetry indices in all three groups. All Asymmetry indices (condylar, ramal, and condylar plus ramal asymmetry) were significantly higher in the unilateral cleft group compared with the other two groups. Conclusion: Cone beam computed tomography images showed that patients with cleft lip and palate suffered from mandibular asymmetry. Subjects with unilateral cleft lip and palate had a more asymmetric mandible compared with the bilateral cleft lip and palate and control groups. Therefore, the mandible appears to be the leading factor in facial asymmetry in subjects with unilateral cleft lip and palate.
- 1 February 2016
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 45 (2) , 20150298
Accuracy of software designed for automated localization of the inferior alveolar nerve canal on cone beam CT images
Objectives:The aim of this study was to design and evaluate a new method for automated localization of the inferior alveolar nerve canal on cone beam computed tomography (CBCT) images.Methods:The proposed method is based on traversing both panoramic and cross-sectional slices. For the panoramic slices, morphological skeletonization is imposed, and a modified Hough transform is used while traversing the cross-sectional slices. A total of 40 CBCT images were randomly selected. Two experts twice located the IAN canal during two examinations set 6 weeks apart. Agreement between experts was achieved, and the result of this manual technique was considered the gold standard for our study. The distances for the automated method and those determined using the gold standard method were calculated and recorded. The mean time required for the automated detection was also recorded.Results:The average mean distance error from the baseline was 0.75±0.34 mm. In all, 86% of the detected points had a mean error of <1 mm co...
- 1 February 2016
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 45 (2) , 20150298
Accuracy of software designed for automated localization of the inferior alveolar nerve canal on cone beam CT images
Objectives:The aim of this study was to design and evaluate a new method for automated localization of the inferior alveolar nerve canal on cone beam computed tomography (CBCT) images.Methods:The proposed method is based on traversing both panoramic and cross-sectional slices. For the panoramic slices, morphological skeletonization is imposed, and a modified Hough transform is used while traversing the cross-sectional slices. A total of 40 CBCT images were randomly selected. Two experts twice located the IAN canal during two examinations set 6 weeks apart. Agreement between experts was achieved, and the result of this manual technique was considered the gold standard for our study. The distances for the automated method and those determined using the gold standard method were calculated and recorded. The mean time required for the automated detection was also recorded.Results:The average mean distance error from the baseline was 0.75±0.34 mm. In all, 86% of the detected points had a mean error of <1 mm co...
- Open Access
- 17 April 2015
- Vol. 12 (2) , 161-166
An in vitro comparison of diagnostic accuracy of cone beam computed tomography and phosphor storage plate to detect simulated occlusal secondary caries under amalgam restoration
This study was aimed to compare the diagnostic accuracy and feasibility of cone beam computed tomography (CBCT) with phosphor storage plate (PSP) in detection of simulated occlusal secondary caries. In this in vitro descriptive-comparative study, a total of 80 slots of class I cavities were prepared on 80 extracted human premolars. Then, 40 teeth were randomly selected out of this sample and artificial carious lesions were created on these teeth by a round diamond bur no. 1/2. All 80 teeth were restored with amalgam fillings and radiographs were taken, both with PSP system and CBCT. All images were evaluated by three calibrated observers. The area under the receiver operating characteristic curve was used to compare the diagnostic accuracy of two systems. SPSS (SPSS Inc., Chicago, IL, USA) was adopted for statistical analysis. The difference between Az value of bitewing and CBCT methods were compared by pairwise comparison method. The inter- and intra-operator agreement was assessed by kappa analysis (P < 0.05). The mean Az value for bitewings and CBCT was 0.903 and 0.994, respectively. Significant differences were found between PSP and CBCT (P = 0.010). The kappa value for inter-observer agreement was 0.68 and 0.76 for PSP and CBCT, respectively. The kappa value for intra-observer agreement was 0.698 (observer 1, P = 0.000), 0.766 (observer 2, P = 0.000) and 0.716 (observer 3, P = 0.000) in PSP method, and 0.816 (observer 1, P = 0.000), 0.653 (observer 2, P = 0.000) and 0.744 (observer 3, P = 0.000) in CBCT method. This in vitro study, with a limited number of samples, showed that the New Tom VGI Flex CBCT system was more accurate than the PSP in detecting the simulated small secondary occlusal caries under amalgam restoration.
- 17 April 2015
- Vol. 12 (2) , 161-166
Open AccessAn in vitro comparison of diagnostic accuracy of cone beam computed tomography and phosphor storage plate to detect simulated occlusal secondary caries under amalgam restoration
This study was aimed to compare the diagnostic accuracy and feasibility of cone beam computed tomography (CBCT) with phosphor storage plate (PSP) in detection of simulated occlusal secondary caries. In this in vitro descriptive-comparative study, a total of 80 slots of class I cavities were prepared on 80 extracted human premolars. Then, 40 teeth were randomly selected out of this sample and artificial carious lesions were created on these teeth by a round diamond bur no. 1/2. All 80 teeth were restored with amalgam fillings and radiographs were taken, both with PSP system and CBCT. All images were evaluated by three calibrated observers. The area under the receiver operating characteristic curve was used to compare the diagnostic accuracy of two systems. SPSS (SPSS Inc., Chicago, IL, USA) was adopted for statistical analysis. The difference between Az value of bitewing and CBCT methods were compared by pairwise comparison method. The inter- and intra-operator agreement was assessed by kappa analysis (P < 0.05). The mean Az value for bitewings and CBCT was 0.903 and 0.994, respectively. Significant differences were found between PSP and CBCT (P = 0.010). The kappa value for inter-observer agreement was 0.68 and 0.76 for PSP and CBCT, respectively. The kappa value for intra-observer agreement was 0.698 (observer 1, P = 0.000), 0.766 (observer 2, P = 0.000) and 0.716 (observer 3, P = 0.000) in PSP method, and 0.816 (observer 1, P = 0.000), 0.653 (observer 2, P = 0.000) and 0.744 (observer 3, P = 0.000) in CBCT method. This in vitro study, with a limited number of samples, showed that the New Tom VGI Flex CBCT system was more accurate than the PSP in detecting the simulated small secondary occlusal caries under amalgam restoration.
- Open Access
- 16 September 2014
- Published by Springer Nature in BMC Medical Imaging
- Vol. 14 (1) , 32
The accuracy of a designed software for automated localization of craniofacial landmarks on CBCT images
Two-dimensional projection radiographs have been traditionally considered the modality of choice for cephalometric analysis. To overcome the shortcomings of two-dimensional images, three-dimensional computed tomography (CT) has been used to evaluate craniofacial structures. However, manual landmark detection depends on medical expertise, and the process is time-consuming. The present study was designed to produce software capable of automated localization of craniofacial landmarks on cone beam (CB) CT images based on image registration and to evaluate its accuracy.
- 16 September 2014
- Published by Springer Nature in BMC Medical Imaging
- Vol. 14 (1) , 32
Open AccessThe accuracy of a designed software for automated localization of craniofacial landmarks on CBCT images
Two-dimensional projection radiographs have been traditionally considered the modality of choice for cephalometric analysis. To overcome the shortcomings of two-dimensional images, three-dimensional computed tomography (CT) has been used to evaluate craniofacial structures. However, manual landmark detection depends on medical expertise, and the process is time-consuming. The present study was designed to produce software capable of automated localization of craniofacial landmarks on cone beam (CB) CT images based on image registration and to evaluate its accuracy.
- Open Access
- 5 March 2014
- Published by Springer Nature in BMC Medical Education
- Vol. 14 (1) , 45
Comparing two methods of education (virtual versus traditional) on learning of Iranian dental students: a post-test only design study
The importance of using technologies such as e-learning in different disciplines is discussed in the literature. Researchers have measured the effectiveness of e-learning in a number of fields.
- 5 March 2014
- Published by Springer Nature in BMC Medical Education
- Vol. 14 (1) , 45
Open AccessComparing two methods of education (virtual versus traditional) on learning of Iranian dental students: a post-test only design study
The importance of using technologies such as e-learning in different disciplines is discussed in the literature. Researchers have measured the effectiveness of e-learning in a number of fields.