Hirohiko Kimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hirohiko Kimura has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Hidehiko Okazawa
Life Science Innovation Center, School of Medical Sciences, University of Fukui, Fukui, Japan
5 shared publications Masayuki Kanamoto
Radiological Center University of Fukui Hospital Eiheiji Fukui Japan
4 shared publications- Nobuyuki Kosaka
Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan
4 shared publications Tatsuro Tsuchida
Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan
4 shared publicationsTsuyoshi Matsuda
Division of Ultra-high Field MRI, Institute for Biomedical Science, Iwate Medical University, Yahaba-cho, Shiwa-gun, Iwate, Japan
4 shared publicationsYasuhiro Fujiwara
Department of Medical Image Sciences, Faculty of Life Sciences Kumamoto University Kumamoto Japan
4 shared publications
Latest Publications
- Open Access
- 16 February 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (4) , 756
Assessment of Arterial Transit Time and Cerebrovascular Reactivity in Moyamoya Disease by Simultaneous PET/MRI
We investigated the relationship between MRI-arterial spin labeling (ASL) parameters and PET-cerebral blood flow (CBF)/cerebrovascular reactivity (CVR) simultaneously obtained by PET/MRI in Moyamoya disease. Twelve patients underwent 15O-water PET/MRI with the acetazolamide (ACZ) challenge test. PET-CBF and PET-CVR were measured using 15O-water PET. Pseudo-continuous ASL obtained the robust arterial transit time (ATT) and ASL-CBF estimation. ASL parameters were compared with PET-CBF and PET-CVR. Before ACZ loading, absolute and relative ASL-CBF were significantly correlated with absolute and relative PET-CBF (r = 0.44, p < 0.0001, and r = 0.55, p < 0.0001, respectively). After ACZ loading, absolute and relative ASL-CBF were significantly correlated with absolute and relative PET-CBF (r = 0.56, p < 0.001, and r = 0.75, p < 0.0001, respectively), and ΔASL-CBF was significantly correlated with ΔPET-CBF (r = 0.65, p < 0.0001). Baseline ASL-ATT had strong negative correlations with ΔPET-CBF and PET-CVR (r = −0.72, p < 0.0001, and r = −0.66, p < 0.0001, respectively). Baseline ASL-ATT of MCA territories with CVR 30% (898 ± 197 ms). ASL-ATT ratio of MCA territories with CVR < 30% (94.0 ± 10.5%) was significantly higher than that with CVR > 30% (81.4 ± 11.3%). ATT correction using multiple postlabeling delays increased the accuracy of ASL-CBF quantitation. Baseline ASL-ATT is a hemodynamic parameter and may represent an efficient alternative to PET-CVR.
- 16 February 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (4) , 756
Open AccessAssessment of Arterial Transit Time and Cerebrovascular Reactivity in Moyamoya Disease by Simultaneous PET/MRI
We investigated the relationship between MRI-arterial spin labeling (ASL) parameters and PET-cerebral blood flow (CBF)/cerebrovascular reactivity (CVR) simultaneously obtained by PET/MRI in Moyamoya disease. Twelve patients underwent 15O-water PET/MRI with the acetazolamide (ACZ) challenge test. PET-CBF and PET-CVR were measured using 15O-water PET. Pseudo-continuous ASL obtained the robust arterial transit time (ATT) and ASL-CBF estimation. ASL parameters were compared with PET-CBF and PET-CVR. Before ACZ loading, absolute and relative ASL-CBF were significantly correlated with absolute and relative PET-CBF (r = 0.44, p < 0.0001, and r = 0.55, p < 0.0001, respectively). After ACZ loading, absolute and relative ASL-CBF were significantly correlated with absolute and relative PET-CBF (r = 0.56, p < 0.001, and r = 0.75, p < 0.0001, respectively), and ΔASL-CBF was significantly correlated with ΔPET-CBF (r = 0.65, p < 0.0001). Baseline ASL-ATT had strong negative correlations with ΔPET-CBF and PET-CVR (r = −0.72, p < 0.0001, and r = −0.66, p < 0.0001, respectively). Baseline ASL-ATT of MCA territories with CVR 30% (898 ± 197 ms). ASL-ATT ratio of MCA territories with CVR < 30% (94.0 ± 10.5%) was significantly higher than that with CVR > 30% (81.4 ± 11.3%). ATT correction using multiple postlabeling delays increased the accuracy of ASL-CBF quantitation. Baseline ASL-ATT is a hemodynamic parameter and may represent an efficient alternative to PET-CVR.
- 1 July 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1135) , 20210572
Atlas-based relaxometry and subsegment analysis of the substantia nigra pars compacta using quantitative MRI: a healthy volunteer study
Objective: Parkinson’s disease is a neurodegenerative disorder caused by neuronal cell loss in the substantia nigra pars compacta (SNpc). We aimed to perform atlas-based relaxometry using an anatomical SNpc atlas and obtain baseline values of SNpc regions in healthy volunteers. Methods: Neuromelanin (NM)-sensitive imaging of the midbrain and whole-brain 3D T1 weighted images of 27 healthy volunteers (20 males; aged 36.3 ± 11.5 years) were obtained. An anatomical SNpc atlas was created using NM-sensitive images in standard space, and divided into medial (MG), dorsal (DG), and ventrolateral (VG) groups. Proton density (PD), T1, and T2 values in these regions were obtained using quantitative MRI. The relationships between PD, T1, and T2 values in each SNpc region and age were evaluated. Results: The VG PD value was significantly higher than the MG and DG values. MG, DG, and VG T1 values were significantly different, whereas the T2 value of the MG was significantly lower than the DG and VG values. Moreover, a significant negative correlation between PD and T1 values of the MG and age was observed. Conclusion: The PD, T1, and T2 values of the SNpc regions measured in standard space using an anatomical atlas can be used as baseline values. PD and T1 values of the SNpc regions may be associated with NM concentrations. Advances in knowledge: An anatomical SNpc atlas was created using NM-sensitive MRI and can be used for the quantitative evaluation of subsegments of the SNpc in standard space.
- 1 July 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1135) , 20210572
Atlas-based relaxometry and subsegment analysis of the substantia nigra pars compacta using quantitative MRI: a healthy volunteer study
Objective: Parkinson’s disease is a neurodegenerative disorder caused by neuronal cell loss in the substantia nigra pars compacta (SNpc). We aimed to perform atlas-based relaxometry using an anatomical SNpc atlas and obtain baseline values of SNpc regions in healthy volunteers. Methods: Neuromelanin (NM)-sensitive imaging of the midbrain and whole-brain 3D T1 weighted images of 27 healthy volunteers (20 males; aged 36.3 ± 11.5 years) were obtained. An anatomical SNpc atlas was created using NM-sensitive images in standard space, and divided into medial (MG), dorsal (DG), and ventrolateral (VG) groups. Proton density (PD), T1, and T2 values in these regions were obtained using quantitative MRI. The relationships between PD, T1, and T2 values in each SNpc region and age were evaluated. Results: The VG PD value was significantly higher than the MG and DG values. MG, DG, and VG T1 values were significantly different, whereas the T2 value of the MG was significantly lower than the DG and VG values. Moreover, a significant negative correlation between PD and T1 values of the MG and age was observed. Conclusion: The PD, T1, and T2 values of the SNpc regions measured in standard space using an anatomical atlas can be used as baseline values. PD and T1 values of the SNpc regions may be associated with NM concentrations. Advances in knowledge: An anatomical SNpc atlas was created using NM-sensitive MRI and can be used for the quantitative evaluation of subsegments of the SNpc in standard space.
- Open Access
Influences of Vitamin B12 Supplementation on Cognition and Homocysteine in Patients with Vitamin B12 Deficiency and Cognitive Impairment
Vitamin B12 deficiency is associated with cognitive impairment, hyperhomocysteinemia, and hippocampal atrophy. However, the recovery of cognition with vitamin B12 supplementation remains controversial. Of the 1716 patients who visited our outpatient clinic for dementia, 83 had vitamin B12 deficiency. Among these, 39 patients (mean age, 80.1 ± 8.2 years) had undergone Mini-Mental State Examination (MMSE) and laboratory tests for vitamin B12, homocysteine (Hcy), and folic acid levels. The hippocampal volume was estimated using the z-score of the MRI-voxel-based specific regional analysis system for Alzheimer’s disease. This is multi-center, open-label, single-arm study. All the 39 patients were administered vitamin B12 and underwent reassessment to measure the retested for MMSE and Hcy after 21−133 days (median = 56 days, interquartile range (IQR) = 43–79 days). After vitamin B12 supplementation, the mean MMSE score improved significantly from 20.5 ± 6.4 to 22.9 ± 5.5 (p < 0.001). Hcy level decreased significantly from 22.9 ± 16.9 nmol/mL to 11.5 ± 3.9 nmol/mL (p < 0.001). Significant correlation was detected between the extent of change in MMSE scores and baseline Hcy values. The degree of MMSE score was not correlated with hippocampal atrophy assessed by the z-score. While several other factors should be considered, vitamin B12 supplementation resulted in improved cognitive function, at least in the short term, in patients with vitamin B12 deficiency.
Open AccessInfluences of Vitamin B12 Supplementation on Cognition and Homocysteine in Patients with Vitamin B12 Deficiency and Cognitive Impairment
Vitamin B12 deficiency is associated with cognitive impairment, hyperhomocysteinemia, and hippocampal atrophy. However, the recovery of cognition with vitamin B12 supplementation remains controversial. Of the 1716 patients who visited our outpatient clinic for dementia, 83 had vitamin B12 deficiency. Among these, 39 patients (mean age, 80.1 ± 8.2 years) had undergone Mini-Mental State Examination (MMSE) and laboratory tests for vitamin B12, homocysteine (Hcy), and folic acid levels. The hippocampal volume was estimated using the z-score of the MRI-voxel-based specific regional analysis system for Alzheimer’s disease. This is multi-center, open-label, single-arm study. All the 39 patients were administered vitamin B12 and underwent reassessment to measure the retested for MMSE and Hcy after 21−133 days (median = 56 days, interquartile range (IQR) = 43–79 days). After vitamin B12 supplementation, the mean MMSE score improved significantly from 20.5 ± 6.4 to 22.9 ± 5.5 (p < 0.001). Hcy level decreased significantly from 22.9 ± 16.9 nmol/mL to 11.5 ± 3.9 nmol/mL (p < 0.001). Significant correlation was detected between the extent of change in MMSE scores and baseline Hcy values. The degree of MMSE score was not correlated with hippocampal atrophy assessed by the z-score. While several other factors should be considered, vitamin B12 supplementation resulted in improved cognitive function, at least in the short term, in patients with vitamin B12 deficiency.
- Open Access
- 1 November 2021
- Published by Oxford University Press (OUP) in BJR|case reports
- Vol. 7 (6) , 20210131
COVID-19 pneumonia detected by [18F]FDG PET/MRI: a case with negative antigen test and chest X-ray results
Since the outbreak of pneumonia caused by a novel coronavirus (SARS-CoV-2) named Coronavirus disease 2019 (COVID-19) in China, researchers have reported the fluorodeoxyglucose positron emission tomography/CT (FDG PET/CT) manifestations of COVID-19 infection. We present a 37-year-old female with early-stage cervical cancer and fever without a focus who had negative SARS-CoV-2 antigen test and chest X-ray results. FDG PET/MRI performed for preoperative evaluation incidentally detected pneumonia showing high FDG uptake and diffusion-weighted imaging signals in right lung base. She retested positive for SARS-CoV-2 and was diagnosed as having COVID-19 pneumonia. Whole-body PET/MRI can provide multi functional images and could be useful for evaluating the pathophysiology of COVID-19.
- 1 November 2021
- Published by Oxford University Press (OUP) in BJR|case reports
- Vol. 7 (6) , 20210131
Open AccessCOVID-19 pneumonia detected by [18F]FDG PET/MRI: a case with negative antigen test and chest X-ray results
Since the outbreak of pneumonia caused by a novel coronavirus (SARS-CoV-2) named Coronavirus disease 2019 (COVID-19) in China, researchers have reported the fluorodeoxyglucose positron emission tomography/CT (FDG PET/CT) manifestations of COVID-19 infection. We present a 37-year-old female with early-stage cervical cancer and fever without a focus who had negative SARS-CoV-2 antigen test and chest X-ray results. FDG PET/MRI performed for preoperative evaluation incidentally detected pneumonia showing high FDG uptake and diffusion-weighted imaging signals in right lung base. She retested positive for SARS-CoV-2 and was diagnosed as having COVID-19 pneumonia. Whole-body PET/MRI can provide multi functional images and could be useful for evaluating the pathophysiology of COVID-19.
- 22 October 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1329-1345
Separating spin compartments in arterial spin labeling using delays alternating with nutation for tailored excitation (DANTE) pulse: A validation study using T2‐relaxometry and application to arterial cerebral blood volume imaging
Purpose: To clarify the type of spin compartment in arterial spin labeling (ASL) that is eliminated by delays alternating with nutation for tailored excitation (DANTE) pulse using T2‐relaxometry, and to demonstrate the feasibility of arterial cerebral blood volume (CBVa) imaging using DANTE‐ASL in combination with a simplified two‐compartment model.Method: The DANTE and T2‐preparation modules were combined into a single ASL sequence. T2 values under the application of DANTE were determined to evaluate changes in T2, along with the post‐labeling delay (PLD) and the relationship between transit time without DANTE (TTnoVS) and T2. The reference tissue T2 (T2_ref) was also obtained. Subsequently, the DANTE module was embedded into the Hadamard‐encoded ASL. Cerebral blood flow (CBF) and CBVa were computed using two Hadamard‐encoding datasets (with and without DANTE) in a rest and breath‐holding (BH) task.Results: While T2 without DANTE (T2_noVS) decreased as the PLD increased, T2 with DANTE (T2_DANTE) was equivalent to T2_ref and did not change with the PLD. Although there was a significant positive correlation between TTnoVS and T2_noVS with short PLD, T2_DANTE was not correlated with TTnoVS nor PLD. Baseline CBVa values obtained at rest were 0.64 ± 0.12, 0.64 ± 0.11, and 0.58 ± 0.15 mL/100 g for anterior, middle, and posterior cerebral arteries, respectively. Significant CBF and CBVa elevations were observed in the BH task.Conclusion: Microvascular compartment signals were eliminated from the total ASL signals by DANTE. CBVa can be measured using Hadamard‐encoded DANTE‐ASL in combination with a simplified two‐compartment model.
- 22 October 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1329-1345
Separating spin compartments in arterial spin labeling using delays alternating with nutation for tailored excitation (DANTE) pulse: A validation study using T2‐relaxometry and application to arterial cerebral blood volume imaging
Purpose: To clarify the type of spin compartment in arterial spin labeling (ASL) that is eliminated by delays alternating with nutation for tailored excitation (DANTE) pulse using T2‐relaxometry, and to demonstrate the feasibility of arterial cerebral blood volume (CBVa) imaging using DANTE‐ASL in combination with a simplified two‐compartment model.Method: The DANTE and T2‐preparation modules were combined into a single ASL sequence. T2 values under the application of DANTE were determined to evaluate changes in T2, along with the post‐labeling delay (PLD) and the relationship between transit time without DANTE (TTnoVS) and T2. The reference tissue T2 (T2_ref) was also obtained. Subsequently, the DANTE module was embedded into the Hadamard‐encoded ASL. Cerebral blood flow (CBF) and CBVa were computed using two Hadamard‐encoding datasets (with and without DANTE) in a rest and breath‐holding (BH) task.Results: While T2 without DANTE (T2_noVS) decreased as the PLD increased, T2 with DANTE (T2_DANTE) was equivalent to T2_ref and did not change with the PLD. Although there was a significant positive correlation between TTnoVS and T2_noVS with short PLD, T2_DANTE was not correlated with TTnoVS nor PLD. Baseline CBVa values obtained at rest were 0.64 ± 0.12, 0.64 ± 0.11, and 0.58 ± 0.15 mL/100 g for anterior, middle, and posterior cerebral arteries, respectively. Significant CBF and CBVa elevations were observed in the BH task.Conclusion: Microvascular compartment signals were eliminated from the total ASL signals by DANTE. CBVa can be measured using Hadamard‐encoded DANTE‐ASL in combination with a simplified two‐compartment model.
- Open Access
- 23 September 2021
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-12
Changes in magnetic resonance imaging relaxation time on postmortem magnetic resonance imaging of formalin-fixed human normal heart tissue
Background: Postmortem magnetic resonance imaging (MRI) has been used to investigate the cause of death, but due to time constraints, it is not widely applied to the heart. Therefore, MRI analysis of the heart after formalin fixation was previously performed. However, the changes in MRI signal values based on the fixation time of formalin were not investigated. The objective was to investigate changes over time in the T1- and T2-values of MRI signals in normal areas of hearts removed during autopsy, hearts subsequently fixed in formalin, and heart specimens sliced for the preparation of pathological specimens. Methods: The study subjects were 21 autopsy cases in our hospital between May 26, 2019 and February 16, 2020 whose hearts were removed and scanned by MRI. The male:female ratio was 14:7, and their ages at death ranged from 9 to 92 years (mean age 65.0 ± 19.7 years). Postmortem (PM)-MRI was conducted with a 0.3-Tesla (0.3-T) scanner containing a permanent magnet. A 4-channel QD head coil was used as the receiver coil. Scans were performed immediately after removal, post-formalin fixation, and after slicing; 7 cases were scanned at all three time points. Results: The T1- and T2-values were calculated from the MRI signals of each sample organ at each scanning stage. Specimens were sliced from removed organs after formalin fixation, and the changes in T1- and T2-values over time were graphed to obtain an approximate curve. The median T1-values at each measurement time point tended to decrease from immediately after removal. The T2-values showed the same tendency to decrease, but this tendency was more pronounced for the T1-values. Conclusion: MRI signal changes in images of heart specimens were investigated. Formalin fixation shortened both T1- and T2-values over time, and approximation formulae were derived to show these decreases over time. The shortening of T1- and T2-values can be understood as commensurate with the reduction in the water content (water molecules) of the formalin-fixed heart.
- 23 September 2021
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-12
Open AccessChanges in magnetic resonance imaging relaxation time on postmortem magnetic resonance imaging of formalin-fixed human normal heart tissue
Background: Postmortem magnetic resonance imaging (MRI) has been used to investigate the cause of death, but due to time constraints, it is not widely applied to the heart. Therefore, MRI analysis of the heart after formalin fixation was previously performed. However, the changes in MRI signal values based on the fixation time of formalin were not investigated. The objective was to investigate changes over time in the T1- and T2-values of MRI signals in normal areas of hearts removed during autopsy, hearts subsequently fixed in formalin, and heart specimens sliced for the preparation of pathological specimens. Methods: The study subjects were 21 autopsy cases in our hospital between May 26, 2019 and February 16, 2020 whose hearts were removed and scanned by MRI. The male:female ratio was 14:7, and their ages at death ranged from 9 to 92 years (mean age 65.0 ± 19.7 years). Postmortem (PM)-MRI was conducted with a 0.3-Tesla (0.3-T) scanner containing a permanent magnet. A 4-channel QD head coil was used as the receiver coil. Scans were performed immediately after removal, post-formalin fixation, and after slicing; 7 cases were scanned at all three time points. Results: The T1- and T2-values were calculated from the MRI signals of each sample organ at each scanning stage. Specimens were sliced from removed organs after formalin fixation, and the changes in T1- and T2-values over time were graphed to obtain an approximate curve. The median T1-values at each measurement time point tended to decrease from immediately after removal. The T2-values showed the same tendency to decrease, but this tendency was more pronounced for the T1-values. Conclusion: MRI signal changes in images of heart specimens were investigated. Formalin fixation shortened both T1- and T2-values over time, and approximation formulae were derived to show these decreases over time. The shortening of T1- and T2-values can be understood as commensurate with the reduction in the water content (water molecules) of the formalin-fixed heart.
- Open Access
- 3 June 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (7) , 306-312
Examining electrometer performance checks with direct‐current generator in a clinic: Assessment of generated charges and implementation of electrometer checks
Purpose: Medical physicists use a suitable detector connected to an electrometer to measure radiotherapy beams. Each detector and electrometer has a lifetime (due to physical deterioration of detector components and electrical characteristic deterioration in electronic electrometer components), long‐term stability [according to IEC 60731:2011, ≤0.5% (reference‐class dosimeter)], and calibration frequency [according to Muir et al. (J Appl Clin Med Phys. 2017; 18:182‐190), generally 2 years]; thus, physicists should check the electrometer and detector separately. However, to the best of our knowledge, only one study (Blad et al., Phys Med Biol. 1998; 43:2385–2391) has reported checking the electrometer independently from the detector. The present study conducts performance checks on electrometers separately from the detector in clinical settings, using an electrometer equipped with a direct current (DC) generator (EMF 521R) capable of injecting DC (effective range: ±20 pA to ±20 nA) into itself or another electrometer.Methods: First, to check the nonlinearity of the generated currents from ±20 pA to ±20 nA, charges generated from the DC generator were measured with the EMF 521R electrometer. Next, six reference‐class electrometers classified according to IEC 60731:2011 were checked for repeatability at a current of ±20 pA or a minimum effective indicated value meeting IEC 60731:2011, as well as for nonlinearity within the current range from ±20 pA to ±20 nA.Results: The nonlinearities for the measured currents were less than ±0.05%. The repeatability for the six electrometers was < 0.1%. While the nonlinearity of one electrometer reached up to 0.22% at a current of –20 pA, all six electrometers displayed nonlinearities of less than ±0.1% at currents of ±100 pA or higher.Conclusions: This work suggests that it is possible to check the nonlinearity and repeatability of clinical electrometers with DCs above the ±30 pA level using a DC generator in a clinic.
- 3 June 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (7) , 306-312
Open AccessExamining electrometer performance checks with direct‐current generator in a clinic: Assessment of generated charges and implementation of electrometer checks
Purpose: Medical physicists use a suitable detector connected to an electrometer to measure radiotherapy beams. Each detector and electrometer has a lifetime (due to physical deterioration of detector components and electrical characteristic deterioration in electronic electrometer components), long‐term stability [according to IEC 60731:2011, ≤0.5% (reference‐class dosimeter)], and calibration frequency [according to Muir et al. (J Appl Clin Med Phys. 2017; 18:182‐190), generally 2 years]; thus, physicists should check the electrometer and detector separately. However, to the best of our knowledge, only one study (Blad et al., Phys Med Biol. 1998; 43:2385–2391) has reported checking the electrometer independently from the detector. The present study conducts performance checks on electrometers separately from the detector in clinical settings, using an electrometer equipped with a direct current (DC) generator (EMF 521R) capable of injecting DC (effective range: ±20 pA to ±20 nA) into itself or another electrometer.Methods: First, to check the nonlinearity of the generated currents from ±20 pA to ±20 nA, charges generated from the DC generator were measured with the EMF 521R electrometer. Next, six reference‐class electrometers classified according to IEC 60731:2011 were checked for repeatability at a current of ±20 pA or a minimum effective indicated value meeting IEC 60731:2011, as well as for nonlinearity within the current range from ±20 pA to ±20 nA.Results: The nonlinearities for the measured currents were less than ±0.05%. The repeatability for the six electrometers was < 0.1%. While the nonlinearity of one electrometer reached up to 0.22% at a current of –20 pA, all six electrometers displayed nonlinearities of less than ±0.1% at currents of ±100 pA or higher.Conclusions: This work suggests that it is possible to check the nonlinearity and repeatability of clinical electrometers with DCs above the ±30 pA level using a DC generator in a clinic.
- Open Access
Influences of Folate Supplementation on Homocysteine and Cognition in Patients with Folate Deficiency and Cognitive Impairment
Although folate deficiency was reported to be associated with hyperhomocysteinemia, influence of folate supplementation on cognition remains controversial. Therefore, we explored the effects of folate supplementation on the cognition and Homocysteine (Hcy) level in relatively short periods in patients with folate deficiency and cognitive impairment. Enrolled 45 patients (mean age of 79.7 ± 7.9 years old) with folate deficiency (12, and Hcy. The degree of hippocampal atrophy in MRI was estimated using a voxel-based specific regional analysis system for Alzheimer’s disease (VSRAD). Patients were administrated folate (5 mg/day), then Hcy, and MMSE score were re-examined after 28 to 63 days. Mean Hcy significantly decreased from 25.0 ± 18.0 to 11.0 ± 4.3 nmol/mL (p < 0.001). Average MMSE scores also significantly changed from 20.1 ± 4.7 to 22.2 ± 4.3 (p < 0.001). The degree of change in the MMSE score and basic Hcy or Hcy change was significantly positively correlated, while degree of hippocampal atrophy in MRI did not. Although several factors should be taken into account, folate supplementation ameliorated cognitive impairment, at least for a short period, in patients with folate deficiency.
Open AccessInfluences of Folate Supplementation on Homocysteine and Cognition in Patients with Folate Deficiency and Cognitive Impairment
Although folate deficiency was reported to be associated with hyperhomocysteinemia, influence of folate supplementation on cognition remains controversial. Therefore, we explored the effects of folate supplementation on the cognition and Homocysteine (Hcy) level in relatively short periods in patients with folate deficiency and cognitive impairment. Enrolled 45 patients (mean age of 79.7 ± 7.9 years old) with folate deficiency (12, and Hcy. The degree of hippocampal atrophy in MRI was estimated using a voxel-based specific regional analysis system for Alzheimer’s disease (VSRAD). Patients were administrated folate (5 mg/day), then Hcy, and MMSE score were re-examined after 28 to 63 days. Mean Hcy significantly decreased from 25.0 ± 18.0 to 11.0 ± 4.3 nmol/mL (p < 0.001). Average MMSE scores also significantly changed from 20.1 ± 4.7 to 22.2 ± 4.3 (p < 0.001). The degree of change in the MMSE score and basic Hcy or Hcy change was significantly positively correlated, while degree of hippocampal atrophy in MRI did not. Although several factors should be taken into account, folate supplementation ameliorated cognitive impairment, at least for a short period, in patients with folate deficiency.
- 19 May 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (8) , e4319
Robust arterial transit time and cerebral blood flow estimation using combined acquisition of Hadamard‐encoded multi‐delay and long‐labeled long‐delay pseudo‐continuous arterial spin labeling: a simulation and in vivo study
Arterial transit time (ATT) prolongation causes an error of cerebral blood flow (CBF) measurement during arterial spin labeling (ASL). To improve the accuracy of ATT and CBF in patients with prolonged ATT, we propose a robust ATT and CBF estimation method for clinical practice. The proposed method consists of a three‐delay Hadamard‐encoded pseudo‐continuous ASL (H‐pCASL) with an additional‐encoding and single‐delay with long‐labeled long‐delay (1dLLLD) acquisition. The additional‐encoding allows for the reconstruction of a single‐delay image with long‐labeled short‐delay (1dLLSD) in addition to the normal Hadamard sub‐bolus images. Five different images (normal Hadamard 3 delay, 1dLLSD, 1dLLLD) were reconstructed to calculate ATT and CBF. A Monte Carlo simulation and an in vivo study were performed to access the accuracy of the proposed method in comparison to normal 7‐delay (7d) H‐pCASL with equally divided sub‐bolus labeling duration (LD). The simulation showed that the accuracy of CBF is strongly affected by ATT. It was also demonstrated that underestimation of ATT and CBF by 7d H‐pCASL was higher with longer ATT than with the proposed method. Consistent with the simulation, the 7d H‐pCASL significantly underestimated the ATT compared to that of the proposed method. This underestimation was evident in the distal anterior cerebral artery (ACA; P = 0.0394) and the distal posterior cerebral artery (PCA; 2 P = 0.0255). Similar to the ATT, the CBF was underestimated with 7d H‐pCASL in the distal ACA (P = 0.0099), distal middle cerebral artery (P = 0.0109), and distal PCA (P = 0.0319) compared to the proposed method. Improving the SNR of each delay image (even though the number of delays is small) is crucial for ATT estimation. This is opposed to acquiring many delays with short LD. The proposed method confers accurate ATT and CBF estimation within a practical acquisition time in a clinical setting.
- 19 May 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (8) , e4319
Robust arterial transit time and cerebral blood flow estimation using combined acquisition of Hadamard‐encoded multi‐delay and long‐labeled long‐delay pseudo‐continuous arterial spin labeling: a simulation and in vivo study
Arterial transit time (ATT) prolongation causes an error of cerebral blood flow (CBF) measurement during arterial spin labeling (ASL). To improve the accuracy of ATT and CBF in patients with prolonged ATT, we propose a robust ATT and CBF estimation method for clinical practice. The proposed method consists of a three‐delay Hadamard‐encoded pseudo‐continuous ASL (H‐pCASL) with an additional‐encoding and single‐delay with long‐labeled long‐delay (1dLLLD) acquisition. The additional‐encoding allows for the reconstruction of a single‐delay image with long‐labeled short‐delay (1dLLSD) in addition to the normal Hadamard sub‐bolus images. Five different images (normal Hadamard 3 delay, 1dLLSD, 1dLLLD) were reconstructed to calculate ATT and CBF. A Monte Carlo simulation and an in vivo study were performed to access the accuracy of the proposed method in comparison to normal 7‐delay (7d) H‐pCASL with equally divided sub‐bolus labeling duration (LD). The simulation showed that the accuracy of CBF is strongly affected by ATT. It was also demonstrated that underestimation of ATT and CBF by 7d H‐pCASL was higher with longer ATT than with the proposed method. Consistent with the simulation, the 7d H‐pCASL significantly underestimated the ATT compared to that of the proposed method. This underestimation was evident in the distal anterior cerebral artery (ACA; P = 0.0394) and the distal posterior cerebral artery (PCA; 2 P = 0.0255). Similar to the ATT, the CBF was underestimated with 7d H‐pCASL in the distal ACA (P = 0.0099), distal middle cerebral artery (P = 0.0109), and distal PCA (P = 0.0319) compared to the proposed method. Improving the SNR of each delay image (even though the number of delays is small) is crucial for ATT estimation. This is opposed to acquiring many delays with short LD. The proposed method confers accurate ATT and CBF estimation within a practical acquisition time in a clinical setting.
- 17 October 2019
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 33 (3) , 367-376
Intravascular signal suppression and microvascular signal mapping using delays alternating with nutation for tailored excitation (DANTE) pulse for arterial spin labeling perfusion imaging
To optimize the delays alternating with nutation for tailored excitation (DANTE) pulse as a vascular crushing gradient to eliminate macro-and micro-vascular signals and to generate a macrovascular space-related map by applying DANTE with multiple conditions.
- 17 October 2019
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 33 (3) , 367-376
Intravascular signal suppression and microvascular signal mapping using delays alternating with nutation for tailored excitation (DANTE) pulse for arterial spin labeling perfusion imaging
To optimize the delays alternating with nutation for tailored excitation (DANTE) pulse as a vascular crushing gradient to eliminate macro-and micro-vascular signals and to generate a macrovascular space-related map by applying DANTE with multiple conditions.