Timothy F. Watson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Timothy F. Watson has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Francesco Mannocci
Department of Endodontics, Centre of Oral Clinical & Translational Sciences, Faculty of Dentistry, Oral & Craniofacial Sciences, Guy’s Dental Hospital, King’s College London, London WC2R 2LS, UK
4 shared publications - Frederic Festy
King’s College London
4 shared publications - Amre R. Atmeh
Hamdan Bin Mohammed College of Dental Medicine (HBMCDM), Mohammed Bin Rashid University of Medicine and Health Sciences (MBRU), Dubai, United Arab Emirates ";" Department of Dentistry, College of Medicine and Health, University of Birmingham, Birmingham, United Kingdom
3 shared publications - Avijit Banerjee
Centre of Oral Clinical Translational Sciences / Conservative & MI Dentistry, Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London, UK
3 shared publications Peter Pilecki
King's College London Dental Institute, Biomaterials, Biomimetics & Biophotonics Research Group, Floor 17, Guy's Tower, Guy's Hospital, London Bridge, London, SE1 9RT, UK
3 shared publicationsA. Boyde
Hard Tissue Research Unit Queen Mary, University of London Mile End Road London E1 4NS U.K.
2 shared publications
Latest Publications
- Open Access
- 23 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 1860
Evaluation of the Periotest Device as an Objective Measuring Tool for Tooth Mobility—A Clinical Evaluation Study
Objective: The aim of this study was to allow researchers to evaluate the Periotest device as a reproducible tool that can be trusted to carry out accurately reproducible and comparable tooth mobility readings. Methods: A reproducibility test was initially conducted taking Periotest recordings for #16 every 10 min with 1 min intervals. Each time, three readings were recorded, and the average of the three was noted. This was followed by recordings for three different subject groups varying in age that were seen three times in 4 weeks, with 2-week intervals between each appointment; recordings were taken of #11, #13 and #16. Nonparametric analysis using the Wilcoxon signed-rank test was carried out. Results: For the reproducibility test, the values of all three readings for each recording session were either exactly the same or differed by up to ±2 Periotest value units. p-value results in the three patient groups showed no significant difference in Periotest values between appointments, with the minor exception of #16 in all three groups, but this was well within the limits of error of the device. Conclusions: Analysis of the Periotest readings in this study indicates that positive (higher) Periotest values correspond to increased tooth mobility.
- 23 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 1860
Open AccessEvaluation of the Periotest Device as an Objective Measuring Tool for Tooth Mobility—A Clinical Evaluation Study
Objective: The aim of this study was to allow researchers to evaluate the Periotest device as a reproducible tool that can be trusted to carry out accurately reproducible and comparable tooth mobility readings. Methods: A reproducibility test was initially conducted taking Periotest recordings for #16 every 10 min with 1 min intervals. Each time, three readings were recorded, and the average of the three was noted. This was followed by recordings for three different subject groups varying in age that were seen three times in 4 weeks, with 2-week intervals between each appointment; recordings were taken of #11, #13 and #16. Nonparametric analysis using the Wilcoxon signed-rank test was carried out. Results: For the reproducibility test, the values of all three readings for each recording session were either exactly the same or differed by up to ±2 Periotest value units. p-value results in the three patient groups showed no significant difference in Periotest values between appointments, with the minor exception of #16 in all three groups, but this was well within the limits of error of the device. Conclusions: Analysis of the Periotest readings in this study indicates that positive (higher) Periotest values correspond to increased tooth mobility.
- Open Access
- 3 July 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (7) , 2086
Rapid Chairside Microbial Detection Predicts Endodontic Treatment Outcome
Background. The aim of this longitudinal, one-year cohort study was to explore the hypothesis that fluorescence sampling of the root canal space prior to obturation could predict the outcome of root canal treatment (RCT). Methods. Sixty-five teeth underwent primary RCT and were followed up clinically and radiographically. The outcome was determined radiographically with periapical radiographs (PR) and cone beam computed tomography (CBCT) scans. Results. Success at 12 months was predictable based on the fluorescence score. When the fluorescence score (defined as the percentage of signal over total signal including background) was lower than 67, there was a 4.5 times (Odds ratio (OR) = 0.028; 95% confidence interval (CI): 0.003, 0.291, p = 0.001) greater chance of success (90% overall). When the readings were above this threshold, the success rate was 20%. Conclusion. A chairside sampling method is able to predict the outcome of RCT, through the use of paper point sampling and fluorescence staining. This has reduced the prevalence of persistent infections by guiding the optimum time for obturation. ClinicalTrials.gov trial NCT03660163.
- 3 July 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (7) , 2086
Open AccessRapid Chairside Microbial Detection Predicts Endodontic Treatment Outcome
Background. The aim of this longitudinal, one-year cohort study was to explore the hypothesis that fluorescence sampling of the root canal space prior to obturation could predict the outcome of root canal treatment (RCT). Methods. Sixty-five teeth underwent primary RCT and were followed up clinically and radiographically. The outcome was determined radiographically with periapical radiographs (PR) and cone beam computed tomography (CBCT) scans. Results. Success at 12 months was predictable based on the fluorescence score. When the fluorescence score (defined as the percentage of signal over total signal including background) was lower than 67, there was a 4.5 times (Odds ratio (OR) = 0.028; 95% confidence interval (CI): 0.003, 0.291, p = 0.001) greater chance of success (90% overall). When the readings were above this threshold, the success rate was 20%. Conclusion. A chairside sampling method is able to predict the outcome of RCT, through the use of paper point sampling and fluorescence staining. This has reduced the prevalence of persistent infections by guiding the optimum time for obturation. ClinicalTrials.gov trial NCT03660163.
- Open Access
- 6 June 2016
- Published by The Royal Society in Interface Focus
- Vol. 6 (3) , 20150113
Root dentine and endodontic instrumentation: cutting edge microscopic imaging
Cutting of the dental hard tissues is an integral part of restorative dentistry. Cutting of the root dentine is also needed in preparation prior to endodontic treatment, with significant commercial investment for the development of flexible cutting instruments based around nickel titanium (NiTi) alloys. This paper describes the evolution of endodontic cutting instruments, both in materials used, e.g. the transition from stainless steel to NiTi, and the design of the actual instruments themselves and their method of activation—by hand or motor driven. We have been examining tooth-cutting interactions microscopically for over 25 years using a variety of microscopic techniques; in particular, video-rate confocal microscopy. This has given a unique insight into how many of the procedures that we take for granted are achieved in clinical practice, by showing microscopic video images of the cutting as it occurs within the tooth. This technology has now been extended to allow imaging of the endodontic instrument and the root canal wall for the first time. We are able to image dentine distortion and crack propagation during endodontic filing of the root canal space. We are also able to visualize the often claimed, but seldom seen action of contemporary endodontic instruments.
- 6 June 2016
- Published by The Royal Society in Interface Focus
- Vol. 6 (3) , 20150113
Open AccessRoot dentine and endodontic instrumentation: cutting edge microscopic imaging
Cutting of the dental hard tissues is an integral part of restorative dentistry. Cutting of the root dentine is also needed in preparation prior to endodontic treatment, with significant commercial investment for the development of flexible cutting instruments based around nickel titanium (NiTi) alloys. This paper describes the evolution of endodontic cutting instruments, both in materials used, e.g. the transition from stainless steel to NiTi, and the design of the actual instruments themselves and their method of activation—by hand or motor driven. We have been examining tooth-cutting interactions microscopically for over 25 years using a variety of microscopic techniques; in particular, video-rate confocal microscopy. This has given a unique insight into how many of the procedures that we take for granted are achieved in clinical practice, by showing microscopic video images of the cutting as it occurs within the tooth. This technology has now been extended to allow imaging of the endodontic instrument and the root canal wall for the first time. We are able to image dentine distortion and crack propagation during endodontic filing of the root canal space. We are also able to visualize the often claimed, but seldom seen action of contemporary endodontic instruments.
- 24 November 2014
- Published by Wiley in Journal of Microscopy
- Vol. 257 (2) , 151-160
Calcium silicate cement‐induced remineralisation of totally demineralised dentine in comparison with glass ionomer cement: tetracycline labelling and two‐photon fluorescence microscopy
Summary: Two‐photon fluorescence microscopy, in combination with tetracycline labelling, was used to observe the remineralising potentials of a calcium silicate‐based restorative material (BiodentineTM) and a glass ionomer cement (GIC:FujiIX) on totally demineralised dentine. Forty demineralised dentine discs were stored with either cement in three different solutions: phosphate buffered saline (PBS) with tetracycline, phosphate‐free tetracycline, and tetracycline‐free PBS. Additional samples of demineralised dentine were stored alone in the first solution. After 8‐week storage at 37 °C, dentine samples were imaged using two‐photon fluorescence microscopy and Raman spectroscopy. Samples were later embedded in PMMA and polished block surfaces studied by 20 kV BSE imaging in an SEM to study variations in mineral concentration. The highest fluorescence intensity was exhibited by the dentine stored with BiodentineTM in the PBS/tetracycline solution. These samples also showed microscopic features of matrix remineralisation including a mineralisation front and intra‐ and intertubular mineralisation. In the other solutions, dentine exhibited much weaker fluorescence with none of these features detectable. Raman spectra confirmed the formation of calcium phosphate mineral with Raman peaks similar to apatite, while no mineral formation was detected in the dentine stored in cement‐free or PBS‐free media, or with GIC. It could therefore be concluded that BiodentineTM induced calcium phosphate mineral formation within the dentine matrix when stored in phosphate‐rich media, which was selectively detectable using the tetracycline labelling.
- 24 November 2014
- Published by Wiley in Journal of Microscopy
- Vol. 257 (2) , 151-160
Calcium silicate cement‐induced remineralisation of totally demineralised dentine in comparison with glass ionomer cement: tetracycline labelling and two‐photon fluorescence microscopy
Summary: Two‐photon fluorescence microscopy, in combination with tetracycline labelling, was used to observe the remineralising potentials of a calcium silicate‐based restorative material (BiodentineTM) and a glass ionomer cement (GIC:FujiIX) on totally demineralised dentine. Forty demineralised dentine discs were stored with either cement in three different solutions: phosphate buffered saline (PBS) with tetracycline, phosphate‐free tetracycline, and tetracycline‐free PBS. Additional samples of demineralised dentine were stored alone in the first solution. After 8‐week storage at 37 °C, dentine samples were imaged using two‐photon fluorescence microscopy and Raman spectroscopy. Samples were later embedded in PMMA and polished block surfaces studied by 20 kV BSE imaging in an SEM to study variations in mineral concentration. The highest fluorescence intensity was exhibited by the dentine stored with BiodentineTM in the PBS/tetracycline solution. These samples also showed microscopic features of matrix remineralisation including a mineralisation front and intra‐ and intertubular mineralisation. In the other solutions, dentine exhibited much weaker fluorescence with none of these features detectable. Raman spectra confirmed the formation of calcium phosphate mineral with Raman peaks similar to apatite, while no mineral formation was detected in the dentine stored in cement‐free or PBS‐free media, or with GIC. It could therefore be concluded that BiodentineTM induced calcium phosphate mineral formation within the dentine matrix when stored in phosphate‐rich media, which was selectively detectable using the tetracycline labelling.
- Open Access
- 1 January 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (1) , 50-61
Present and future of glass-ionomers and calcium-silicate cements as bioactive materials in dentistry: Biophotonics-based interfacial analyses in health and disease
- 1 January 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (1) , 50-61
Open AccessPresent and future of glass-ionomers and calcium-silicate cements as bioactive materials in dentistry: Biophotonics-based interfacial analyses in health and disease
- Top Cited Papers
- 20 March 2012
- Published by SAGE Publications in Journal of Dental Research
- Vol. 91 (5) , 454-459
Dentin-cement Interfacial Interaction
The interfacial properties of a new calcium-silicate-based coronal restorative material (Biodentine™) and a glass-ionomer cement (GIC) with dentin have been studied by confocal laser scanning microscopy (CLSM), scanning electron microscopy (SEM), micro-Raman spectroscopy, and two-photon auto-fluorescence and second-harmonic-generation (SHG) imaging. Results indicate the formation of tag-like structures alongside an interfacial layer called the “mineral infiltration zone”, where the alkaline caustic effect of the calcium silicate cement’s hydration products degrades the collagenous component of the interfacial dentin. This degradation leads to the formation of a porous structure which facilitates the permeation of high concentrations of Ca2+, OH-, and CO32- ions, leading to increased mineralization in this region. Comparison of the dentin-restorative interfaces shows that there is a dentin-mineral infiltration with the Biodentine, whereas polyacrylic and tartaric acids and their salts characterize the penetration of the GIC. A new type of interfacial interaction, “the mineral infiltration zone”, is suggested for these calcium-silicate-based cements.
- 20 March 2012
- Published by SAGE Publications in Journal of Dental Research
- Vol. 91 (5) , 454-459
Top Cited PapersDentin-cement Interfacial Interaction
The interfacial properties of a new calcium-silicate-based coronal restorative material (Biodentine™) and a glass-ionomer cement (GIC) with dentin have been studied by confocal laser scanning microscopy (CLSM), scanning electron microscopy (SEM), micro-Raman spectroscopy, and two-photon auto-fluorescence and second-harmonic-generation (SHG) imaging. Results indicate the formation of tag-like structures alongside an interfacial layer called the “mineral infiltration zone”, where the alkaline caustic effect of the calcium silicate cement’s hydration products degrades the collagenous component of the interfacial dentin. This degradation leads to the formation of a porous structure which facilitates the permeation of high concentrations of Ca2+, OH-, and CO32- ions, leading to increased mineralization in this region. Comparison of the dentin-restorative interfaces shows that there is a dentin-mineral infiltration with the Biodentine, whereas polyacrylic and tartaric acids and their salts characterize the penetration of the GIC. A new type of interfacial interaction, “the mineral infiltration zone”, is suggested for these calcium-silicate-based cements.
- 1 August 2009
- Vol. 11 (4) , 271-278
Prevention of Water Contamination of Ethanol-saturated Dentin and Hydrophobic Hybrid Layers
Purpose: This in vitro study evaluated the amount and distribution of outward fluid flow that occurred when an experimental etch-and-rinse hydrophobic adhesive was applied to ethanol-saturated dentin before and after oxalate pretreatment. Materials and Methods: Measurements of dentin permeability were performed under a constant pulpal pressure of 20 cm H(2)O in deep and middle dentin. A lucifer yellow solution was placed in the pulp chamber to determine the distribution of the water contamination of the hybrid layers. Results: The distribution of fluorescence in dentin specimens that were not pretreated with oxalate revealed that the dye permeated around the resin tags and filled the hybrid layer. Dentin specimens pretreated with oxalate prior to resin bonding, showed 80% to 83% less (p < 0.05) water contamination compared to controls. The dentin permeability results obtained before and after oxalate pretreatment showed that oxalate decreased dentin permeability by 98% (p < 0.05) compared to acid-etched controls. This prevented outward fluid movement during bonding, resulting in better resin sealing of dentin due to the formation of a double seal of resin tags over calcium oxalate crystals in the tubules. Conclusion: Outward dentinal fluid flow may contaminate hybrid layers during adhesive bonding procedures. Pretreatment of acid-etched dentin with 3% oxalic acid prior to bonding procedures can prevent outward fluid flow during bonding and water contamination of the hydrophobic hybrid layers.
- 1 August 2009
- Vol. 11 (4) , 271-278
Prevention of Water Contamination of Ethanol-saturated Dentin and Hydrophobic Hybrid Layers
Purpose: This in vitro study evaluated the amount and distribution of outward fluid flow that occurred when an experimental etch-and-rinse hydrophobic adhesive was applied to ethanol-saturated dentin before and after oxalate pretreatment. Materials and Methods: Measurements of dentin permeability were performed under a constant pulpal pressure of 20 cm H(2)O in deep and middle dentin. A lucifer yellow solution was placed in the pulp chamber to determine the distribution of the water contamination of the hybrid layers. Results: The distribution of fluorescence in dentin specimens that were not pretreated with oxalate revealed that the dye permeated around the resin tags and filled the hybrid layer. Dentin specimens pretreated with oxalate prior to resin bonding, showed 80% to 83% less (p < 0.05) water contamination compared to controls. The dentin permeability results obtained before and after oxalate pretreatment showed that oxalate decreased dentin permeability by 98% (p < 0.05) compared to acid-etched controls. This prevented outward fluid movement during bonding, resulting in better resin sealing of dentin due to the formation of a double seal of resin tags over calcium oxalate crystals in the tubules. Conclusion: Outward dentinal fluid flow may contaminate hybrid layers during adhesive bonding procedures. Pretreatment of acid-etched dentin with 3% oxalic acid prior to bonding procedures can prevent outward fluid flow during bonding and water contamination of the hydrophobic hybrid layers.
- 1 March 2008
- Published by Operative Dentistry in Operative Dentistry
- Vol. 33 (2) , 215-224
Operative Dentistry and the Abuse of Dental Hard Tissues: Confocal Microscopical Imaging of Cutting
We reviewed studies wherein the cutting of dental tissues, simulating interactions that would occur under clinical circumstances in the mouth, have been observed directly-first by real time, video rate, stereoscopic, three-dimensional scanning electron microscopy; and second and more conveniently, by video rate confocal optical microscopy. We have observed, directly, both the interactions of slow-moving cutting instruments emulating "chisels" and high-speed events, including the effects of rotary burs and air-propelled abrasive particles and soft powder slurries. The observational data contribute to our basic understanding of the functional behavior of dental tissues and formed a useful background for the practitioner of operative dentistry.
- 1 March 2008
- Published by Operative Dentistry in Operative Dentistry
- Vol. 33 (2) , 215-224
Operative Dentistry and the Abuse of Dental Hard Tissues: Confocal Microscopical Imaging of Cutting
We reviewed studies wherein the cutting of dental tissues, simulating interactions that would occur under clinical circumstances in the mouth, have been observed directly-first by real time, video rate, stereoscopic, three-dimensional scanning electron microscopy; and second and more conveniently, by video rate confocal optical microscopy. We have observed, directly, both the interactions of slow-moving cutting instruments emulating "chisels" and high-speed events, including the effects of rotary burs and air-propelled abrasive particles and soft powder slurries. The observational data contribute to our basic understanding of the functional behavior of dental tissues and formed a useful background for the practitioner of operative dentistry.
- 1 January 2008
- Published by Elsevier
Contributor contact details
- 1 November 2007
- Vol. 12 (7) , E542-8
The influence of soft acidic drinks in exposing dentinal tubules after non-surgical periodontal treatment: a SEM investigation on the protective effects of oxalate-containing phytocomplex.
The aim of this study was to investigate the different smear layer morphologies produced by instrumentation with a hand curette and a periodontal sonic scaler for potential removal by soft acidic solution. The effect of a new oxalate-containing phytocomplex spray in preventing tubules exposure after citric acid solution application was also evaluated. Thirty recently extracted human teeth were used to obtain root dentinal fragments and divided in two groups: Curette treatment (CRT) root planed applying 30 working strokes to each surface using a Gracey's curette 5-6 and Ultrasonic scaler (USC) treated using a periodontal scaler mounted on an ultrasonic hand-piece for 30 seconds. Each principal group was further divided in three sub-groups (Control, Acid challenge and Acid/Phyto-oxalate). The control group samples were immersed in distilled water buffered to pH 7.4 using NH4OH solution. The samples of the acid challenge group were immersed in a solution of citric acid 0,02 M; [pH 2.5] for 3 minutes. The samples of the Acid/Phyto-oxalate group were sprayed for 15 sec with a 1.5% phytocomplex spray prior to immersion. Samples were examined using SEM. Ultrasonic instrumentation created a very thin smear layer whereas curettes produced a multilayered smear layer. The acidic solution was able to remove the smear layer from root surfaces treated with ultrasonic instrumentation exposing the dentinal tubules. The smear layer on the root surfaces treated with hand instruments was not completely removed. The phytocomplex solution was able to prevent dentinal tubule exposure. Acidic soft drinks are able to remove the smear layer created on root surfaces during different non-surgical periodontally treatments. The smear plugs created by hand instrumentation appeared to be more resistant to acid attack. The tested phytocomplex solution protected the dentine from demineralization and it might prevent post-treatment dentinal hypersensitivity induced by acidic soft drinks.
- 1 November 2007
- Vol. 12 (7) , E542-8
The influence of soft acidic drinks in exposing dentinal tubules after non-surgical periodontal treatment: a SEM investigation on the protective effects of oxalate-containing phytocomplex.
The aim of this study was to investigate the different smear layer morphologies produced by instrumentation with a hand curette and a periodontal sonic scaler for potential removal by soft acidic solution. The effect of a new oxalate-containing phytocomplex spray in preventing tubules exposure after citric acid solution application was also evaluated. Thirty recently extracted human teeth were used to obtain root dentinal fragments and divided in two groups: Curette treatment (CRT) root planed applying 30 working strokes to each surface using a Gracey's curette 5-6 and Ultrasonic scaler (USC) treated using a periodontal scaler mounted on an ultrasonic hand-piece for 30 seconds. Each principal group was further divided in three sub-groups (Control, Acid challenge and Acid/Phyto-oxalate). The control group samples were immersed in distilled water buffered to pH 7.4 using NH4OH solution. The samples of the acid challenge group were immersed in a solution of citric acid 0,02 M; [pH 2.5] for 3 minutes. The samples of the Acid/Phyto-oxalate group were sprayed for 15 sec with a 1.5% phytocomplex spray prior to immersion. Samples were examined using SEM. Ultrasonic instrumentation created a very thin smear layer whereas curettes produced a multilayered smear layer. The acidic solution was able to remove the smear layer from root surfaces treated with ultrasonic instrumentation exposing the dentinal tubules. The smear layer on the root surfaces treated with hand instruments was not completely removed. The phytocomplex solution was able to prevent dentinal tubule exposure. Acidic soft drinks are able to remove the smear layer created on root surfaces during different non-surgical periodontally treatments. The smear plugs created by hand instrumentation appeared to be more resistant to acid attack. The tested phytocomplex solution protected the dentine from demineralization and it might prevent post-treatment dentinal hypersensitivity induced by acidic soft drinks.