UNUlrich Neitzel

Ulrich Neitzel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ulrich Neitzel has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Radiologist and CAD Performance in the Detection of CT-confirmed Subtle Pulmonary Nodules on Digital Chest Radiographs

    by Thorsten Alexander Bley, Tobias Baumann, Ulrich Saueressig, Gregor Pache, Markus Treier, Oliver Schaefer, Ulrich Neitzel, Mathias Langer, Elmar Kotter

    Detection of subtle pulmonary nodules on digital radiography is a challenging task for radiologists. The aim of this study was to evaluate the performance of a newly approved computer aided detection (CAD) system. The sensitivity of 3 radiologists and of a CAD system for the detection of pulmonary nodules from 5 to 15 mm in size on digital chest radiography of 117 patients was compared. The reference standard was established by consensus reading of computed tomography scans by 2 experienced radiologists. Computed tomography scans and chest radiographs were performed within 4 weeks. Sixty-six pulmonary nodules from 42 patients, with a mean nodule diameter of 7.5 mm (standard deviation: 2.2 mm), were included in the statistical analysis. Seventy-five of the 117 patients did not have nodules from 5 to 15 mm of size. Two hundred and eighty-eight false-positive detections of the CAD system were found with an average of 2.5 false-positives per image. Sensitivity of the CAD system was 39.4% (95% confidence interval: 11.8%), when compared with 18.2% to 30.3% (95% confidence interval 9.3% to 11.1%) of the 3 radiologists. Substantial agreement for nodule detection ([kappa]N: 0.64-0.73) was found among the 3 radiologists, whereas only moderate agreement was found between the radiologists and the CAD performance ([kappa]N: 0.45-0.52). The CAD system's diagnostic sensitivity in detecting pulmonary nodules of 5 to 15 mm of size was superior to the 1 of radiologists. The CAD system may be used for assisting the radiologist in the detection of lung nodules on digital chest radiographs.


  • Open Access

    Digital chest radiography: an update on modern technology, dose containment and control of image quality

    by Cornelia Schaefer-Prokop, Ulrich Neitzel, Henk W. Venema, Martin Uffmann, Mathias Prokop

    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems.


  • Retrospective patient dose analysis of a digital radiography system in routine clinical use

    by Astrid Schuncke, Ulrich Neitzel

    The log files generated in the flat-panel detector based digital radiography systems (Philips Digital Diagnost) at 11 different hospitals were used to acquire data regarding the dose-area product (DAP) and the entrance air kerma (EAK) for all X-ray examinations performed in routine clinical use. A retrospective statistical analysis of the data with respect to the dose levels was performed for several examination types. The resulting average dose levels were compared with the diagnostic reference levels (DRLs). While for the same type of examination the median dose level at different hospitals could differ by up to a factor of 5, almost all the dose levels were found to be much below the published DRL. Only in one hospital for one type of examination (Thorax PA) the DRL for the DAP was slightly exceeded, while for the same site and examination the EAK was still below the DRL. In conclusion, examination log files can be used for retrospective dose analysis and correlation with DRLs.


  • Status and prospects of digital detector technology for CR and DR

    by Ulrich Neitzel

    Projection radiography is in the middle of the transition from conventional screen-film imaging to digital image acquisition modalities, mainly based on imaging plates (computed radiography, CR) and flat-panel detectors (direct radiography, DR). Cassette-based CR has been available for the past 20 y, and constitutes the major part of direct radiography installations in hospitals today. direct radiography systems based on large-area amorphous silicon active matrix arrays are commercially available for the last 5 y and exist basically in two different types: with scintillators or photoconductors as X-ray conversion material (‘indirect’ or ‘direct’ type). direct radiography systems allow for improved image quality and/or dose reduction due to their high detective quantum efficiency and enable faster workflow because of instant image availability. However, new technology developments are improving the performance for CR systems as well, rendering it competitive to direct radiography in many practical aspects. Therefore, it is assumed that the CR and direct radiography systems will coexist for many years to come. This paper reviews the digital detector technologies and the possible future directions of development.


  • Flat-Panel–Detector Chest Radiography: Effect of Tube Voltage on Image Quality

    by Martin Uffmann, Ulrich Neitzel, Mathias Prokop, Nahla Kabalan, Michael Weber, Christian J. Herold, Cornelia Schaefer-Prokop


  • Determination of the modulation transfer function using the edge method: Influence of scattered radiation

    by Ulrich Neitzel, Egbert Buhr, Gerhard Hilgers, Paul R. Granfors

    The edge method for measuring the modulation transfer function (MTF) has recently gained popularity due to its simplicity and appropriateness particularly for digital imaging systems. Often edge test devices made of rather thin metal sheets are used, which are semitransparent to x rays and may generate scattered radiation. The effect of this scattered radiation on the determined MTF was investigated both theoretically (assuming an ideal detector) and experimentally using a CsI-based digital detector. It was found that the MTF increases due to the scattered radiation for all spatial frequencies larger than 0 mm(-1). The theoretical model developed in this study predicts that the maximum error compared to the true detector MTF is given by S/A, where A is the attenuated fraction and S is the scattered fraction reaching the detector, relative to the incident radiation. Theoretical and experimental results are in good agreement for radiation qualities corresponding to general radiography (RQA3, RQA5, and RQA7), whereas for chest beam quality (RQA9) the experimentally observed MTF error is larger than predicted by the simple model, possibly because the energy response of the CsI-based detector differs from that of an ideal one. The theoretical MTF error reaches a value of 18% for a 0.25 mm thick lead edge of RQA9. Since the MTF enters squared into the determination of the detective quantum efficiency (DQE), an error of at least 36% in DQE may result when using this edge test device. In conclusion, the use of fully absorbing edge material is advised for MTF determination with the edge method.


  • Management of pediatric radiation dose using Philips digital radiography

    by U. Neitzel

    Digital radiography systems based on flat-panel detectors have been introduced into clinical practice in the past few years. The high detective quantum efficiency of these detectors allows the radiation dose to be reduced while maintaining image quality, an issue particularly significant for pediatric radiography. Another important aspect for dose optimization and monitoring is the integration of the detector into a computer-controlled x-ray examination system. This enables full control and complete reporting of all dose-relevant exposure parameters, including the determination of the exposure indicator and the patient dose (kerma-area product). In this paper the implementation of these principles in the Philips Digital Diagnost DR system is described and their relevance for pediatric applications is discussed.


  • Determination of the detective quantum efficiency of a digital x-ray detector: Comparison of three evaluations using a common image data set

    by Ulrich Neitzel, Susanne Günther-Kohfahl, Giovanni Borasi, Ehsan Samei

    The detective quantum efficiency (DQE) of an x-ray digital imaging detector was determined independently by the three participants of this study, using the same data set consisting of edge and flat field images. The aim was to assess the possible variation in DQE originating from established, but slightly different, data processing methods used by different groups. For the case evaluated in this study differences in DQE of up to +/-15% compared to the mean were found. The differences could be traced back mainly to differences in the modulation transfer function (MTF) and noise power spectrum (NPS) determination. Of special importance is the inclusion of a possible low-frequency drop in MTF and the proper handling of signal offsets for the determination of the NPS. When accounting for these factors the deviation between the evaluations reduced to approximately +/-5%. It is expected that the recently published standard on DQE determination will further reduce variations in the data evaluation and thus in the results of DQE measurements.


  • Comparison of an Automatic Versus a Semiautomatic Mode for Gray-Scale Adaptation for Digital Chest Radiography

    by Johannes Sailer, Mathias Prokop, Ulrich Neitzel, Michael Weber, Philipp Peloschek, Cornelia Schaefer-Prokop

    To compare image quality of digital chest radiographs using 2 modes of gradation adjustment. We compared image quality and visualization of anatomic landmarks of 50 chest radiographs after digital processing using a semiautomatic mode with a fixed gamma of 2.6 and an automatic mode with individual gamma adaptation. The mean gamma was significantly higher (P < 0.001) with the automatic mode (3.0 vs. 2.6, respectively). Patient constitution had no impact on the automatically adapted gamma for PA but showed a significant correlation (P < 0.001) for lateral images. For PA, there was a preference (P < 0.016) of the semiautomatic mode in heavier patients whereas no difference was seen in slim patients. For the lateral projection, there was a general preference (P = 0.001) of the automatic mode. For PA radiographs, the semiautomatic mode provides superior results for heavier patients without compromising the quality in slim patients. For lateral radiographs, the automatic mode provides generally superior results.


  • Skeletal Applications for Flat-Panel versus Storage-Phosphor Radiography: Effect of Exposure on Detection of Low-Contrast Details

    by Martin Uffmann, Cornelia Schaefer-Prokop, Ulrich Neitzel, Michael Weber, Christian J. Herold, Mathias Prokop