LALuciana Malta de Alencar

Luciana Malta de Alencar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Luciana Malta de Alencar has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Robert N. Weinreb

    Department of Ophthalmology, Hamilton Glaucoma Center, University of California at San Diego, La Jolla, CA

    21 shared publications
  • Felipe Andrade Medeiros

    Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, CA

    18 shared publications
  • Linda M. Zangwill

    Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, CA

    17 shared publications
  • Pamela A. Sample

    From the Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, California

    17 shared publications
  • Christopher Bowd

    Hamilton Glaucoma Center and Division of Ophthalmology Informatics and Data Science, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California, San Diego, CA 92037, USA

    10 shared publications
  • Gianmarco Vizzeri

    Department of Ophthalmology, Hamilton Glaucoma Center, University of California at San Diego, La Jolla, CA

    8 shared publications

Latest Publications

  • Open Access

    Nd:YAG Laser Goniopuncture for Late Bleb Failure After Trabeculectomy With Adjunctive Mitomycin C

    by Remo Susanna, Carlos G. De Moraes, Luciana M. Alencar, Robert Ritch

    The success of trabeculectomy depends on the creation of a filtering bleb. Early and late failure is usually attributable to subconjunctival fibrosis.1 For late failure, surgical intervention such as needling procedures or surgical revision is usually necessary. Needling is an effective procedure to restore function of encapsulated blebs by mechanical dissection of the subconjunctival scar tissue, and a large proportion of failed or failing blebs can be rescued. With varying definitions of success, rates of 7% to 69% have been reported for needling alone and of 75% to 94% for needling with simultaneous or adjunctive administration of antifibrotic agents (5-fluorouracil or mitomycin C).2-7 Complications can occur and may be serious.6,8,9


  • Repeatability and Reproducibility of Goldmann Applanation, Dynamic Contour, and Ocular Response Analyzer Tonometry

    by Allen Shawlun Wang, Luciana M. Alencar, Robert N. Weinreb, Ali Bs Tafreshi, Sunil Deokule, Gianmarco Vizzeri, Felipe A. Medeiros

    Purpose To evaluate the repeatability and interoperator reproducibility of the Pascal dynamic contour tonometry (DCT), ocular response analyzer (ORA), and Goldmann applanation tonometer (GAT) in a single population of normal individuals. Methods The study included 52 eyes from 26 normal individuals. One operator measured the intraocular pressure (IOP) with each tonometer 3 times while 2 additional operators each measured the IOP with each tonometer once. Repeatability and reproducibility were assessed by the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Agreement among tonometers was also assessed using Bland-Altman plots. Results The mean age of included participants was 31.5±8.8 years and 15 (58%) were female individuals. In general, both intraoperator repeatability and interoperator reproducibility were significantly higher for DCT compared with the other tonometers. Intraoperator DCT (CV=3.7, ICC=0.89), GAT (CV=9.7, ICC=0.79), IOPg (CV=7.0, ICC=0.79), and IOPcc (CV=9.8, ICC=0.57). Interoperator DCT (CV=6.1, ICC=0.73), GAT (CV=9.0, ICC=0.82), and IOPg (CV=10.8, ICC=0.63), IOPcc (CV=11.7, ICC=0.49). Conclusion Overall, DCT was significantly more repeatable and reproducible than GAT, IOPg and IOPcc. The better reproducibility of the DCT may result in more precise measurements for monitoring IOP changes over time compared to GAT and ORA.


  • Reproducibility of intraocular pressure peak and fluctuation of the water‐drinking test

    by Marcelo Hatanaka, Luciana M Alencar, Carlos G De Moraes, Remo Susanna

    Background: The water‐drinking test has been used as a stress test to evaluate the drainage system of the eye. However, in order to be clinically applicable,a test must provide reproducible results with consistent measurements. This study was performed to verify the reproducibility of intraocular pressure peaks and fluctuation detected during the water‐drinking test in patients with ocular hypertension and open‐angle glaucoma.Design: A prospective analysis of patients in a tertiary care unit for glaucoma treatment.Participants: Twenty‐four ocular hypertension and 64 open‐angle glaucoma patients not under treatment.Methods: The water‐drinking test was performed in 2 consecutive days by the same examiners in patients not under treatment. Reproducibility was assessed using the intraclass correlation coefficient.Main Outcome Measures: Peak and fluctuation of intraocular pressure obtained with the water‐drinking test were analysed for reproducibility.Results: Eighty‐eight eyes from 24 ocular hypertension and 64 open‐angle glaucoma patients not under treatment were evaluated. Test and retest intraocular pressure peak values were 28.38 ± 4.64 and 28.38 ± 4.56 mmHg, respectively (P = 1.00). Test and retest intraocular pressure fluctuation values were 5.75 ± 3.9 and 4.99 ± 2.7 mmHg, respectively (P = 0.06). Based on intraclass coefficient, reproducibility was excellent for peak intraocular pressure (intraclass correlation coefficient = 0.79) and fair for intraocular pressure fluctuation (intraclass correlation coefficient = 0.37).Conclusion: Intraocular pressure peaks detected during the water‐drinking test presented excellent reproducibility, whereas the reproducibility of fluctuation was considered fair.


  • Open Access

    Técnica Tied Out Open Sky: fixação iriana de lente intraocular combinada com transplante penetrante de córnea

    by Victor Andriguetti Coronado Antunes, Wilson Takashi Hida, Danilo da Costa Sousa, Iris Yamane, Fernando Moro, Karine Borges Marques Moysés, Tadeu Cvintal, Luciana Malta de Alencar, Celso Takashi Nakano, Patrick Frensel Tzelikis

    To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely

  • Comparison of Unenhanced and Enhanced Imaging Protocols for Angle Measurements With Anterior Segment Optical Coherence Tomography

    by Sunil Deokule, Luciana Alencar, Gianmarco Vizzeri, Felipe Medeiros, Robert N. Weinreb

    BACKGROUND AND OBJECTIVE: To compare the intraobserver and interobserver agreement of anterior chamber angle measurements using unenhanced and enhanced imaging protocols for anterior segment optical coherence tomography (AS-OCT). PATIENTS AND METHODS: Anterior segments of 30 eyes of 15 healthy subjects (mean age: 33.8 ± 13.0 years, 8 women) were imaged by a single examiner with AS-OCT using unenhanced and enhanced imaging protocol. Two masked observers analyzed each image independently on two separate occasions. The reproducibility of angle parameters was estimated by calculating coefficients of variation separately for each observer. Bland–Altman plots were constructed to assess the intraobserver and interobserver agreement. RESULTS: The intraobserver and interobserver reproducibility was similar between imaging protocols. Intra-observer and interobserver agreements were also similar for all parameters evaluated. The best estimate of scleral spur location was determined in all images by both observers. CONCLUSION: Measurement variability was similar with the unenhanced and enhanced imaging protocol in this series of eyes with open angles.


  • Structure-function Relationships Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry

    by Mauro T. Leite, Linda M. Zangwill, Robert N. Weinreb, Harsha L. Rao, Luciana M. Alencar, Felipe A. Medeiros

    Purpose: To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). Methods: Four hundred twenty-two eyes (78 healthy, 210 suspects, 134 glaucomatous) of 250 patients were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study and from the African Descent and Glaucoma Evaluation Study. All eyes underwent testing with the Cirrus SDOCT and SAP within a 6-month period. The relationship between parapapillary retinal nerve fiber layer thickness (RNFL) sectors and corresponding topographic SAP locations was evaluated using locally weighted scatterplot smoothing and regression analysis. SAP sensitivity values were evaluated using both linear as well as logarithmic scales. We also tested the fit of a model (Hood) for structure-function relationship in glaucoma. Results: Structure was significantly related to function for all but the nasal thickness sector. The relationship was strongest for superotemporal RNFL thickness and inferonasal sensitivity (R2=0.314, P<0.001). The Hood model fitted the data relatively well with 88% of the eyes inside the 95% confidence interval predicted by the model. Conclusions: RNFL thinning measured by the Cirrus SDOCT was associated with correspondent visual field loss in glaucoma.


  • Detection of retinal nerve fibre layer progression: comparison of the fast and extended modes of GDx guided progression analysis

    by Sara M Kjaergaard, Luciana M Alencar, Bac Nguyen, Patrick Sassani, F. A. Medeiros, Robert N Weinreb, Linda M Zangwill

    Purpose To compare detection of retinal nerve fibre layer changes using GDx guided progression analysis (GPA) fast mode (which assumes fixed variability of a reference population) and extended mode (which measures individual variability), and to determine how they compare with photography and conventional visual field-based methods for identifying glaucoma progression. Methods 172 eyes from 117 participants in the Diagnostic Innovations in Glaucoma Study (12 healthy, 108 glaucoma suspects and 52 glaucoma eyes) with ≥4 GDx VCC visits and ≥3 good quality GDx VCC scans at each visit were included. Results Agreement between the GDx GPA fast mode and GDx GPA extended mode was limited. The GDx fast mode and extended mode detected 15 and 18 eyes, respectively, as ‘likely progression’, but only seven of them agreed. The conventional reference standard (stereophotograph-based optic disc and/or visual field progression) identified nine eyes as progressing, of which two eyes were also identified by the GDx fast mode and three eyes by the extended mode. In the GDx fast mode, we found that the progression detection varied depending on which two scans were included in the baseline and follow-up images. Conclusion There was limited agreement between the GDx fast mode and the GDx extended mode for progression detection, and between different scans included in the GDx fast mode progression analysis. Longer follow-up is needed to determine the proportion of eyes classified as ‘likely progression’ by the GDx analysis that are early change and the proportion that are false positive results.


  • Oculometric parameters of hyperopia in children with esotropic amblyopia

    by Iara Debert, Luciana Malta de Alencar, Mariza Polati, Murilo Barreto Souza, Milton Ruiz Alves

    Citation information: Debert I, de Alencar LM, Polati M, Souza MB & Alves MR. Oculometric parameters of hyperopia in children with esotropic amblyopia. Ophthalmic Physiol Opt 2011, 31 , 389–397. doi: 10.1111/j.1475‐1313.2011.00850.x Purpose:  To study the oculometric parameters of hyperopia in children with esotropic amblyopia, comparing amblyopic eyes with fellow eyes. Methods:  Thirty‐seven patients (5–8 years old) with bilateral hyperopia and esotropic amblyopia underwent a comprehensive ophthalmic examination, including cycloplegic refraction, keratometry and A‐scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. The refractive power of the crystalline lens was calculated using Bennett’s equations. Paired Student’s t ‐tests were used to compare ocular biometric measurements between amblyopic eyes and their fellow eyes. The associations of biometric parameters with refractive errors were assessed using Pearson correlation coefficients and linear regression. Multivariable models including axial length, corneal power and lens power were also constructed. Results:  Amblyopic eyes were found to have significantly more hyperopic refraction, less corneal power, greater lens power, shorter vitreous chamber depth and shorter axial length, despite similar anterior chamber depth and lens thickness. The strongest correlation with refractive error was observed for the axial length/corneal radius ratio ( r 36 = −0.92, p < 0.001 for amblyopic and r 36 = −0.87, p < 0.001 for fellow eyes). Axial length accounted for 39.2% ( R 2 ) of the refractive error variance in amblyopic eyes and 35.5% in fellow eyes. Adding corneal power to the model increased R 2 to 85.7% and 79.6%, respectively. A statistically significant correlation was found between axial length and corneal power, indicating decreasing corneal power with increasing axial length, and they were similar for amblyopic eyes ( r 36 = −0.53, p < 0.001) and fellow eyes ( r 36 = −0.57, p < 0.001). A statistically significant correlation was also found between axial length and lens power, indicating decreasing lens power with increasing axial length ( r 36 = −0.72, p < 0.001 for amblyopic eyes and r 36 = −0.69, p < 0.001 for fellow eyes). Conclusions:  We observed that the correlation among the major oculometric parameters and their individual contribution to hyperopia in esotropic children were similar in amblyopic and non‐amblyopic eyes. This finding suggests that the counterbalancing effect of greater corneal and lens power associated with shorter axial length is similar in both eyes of patients with esotropic amblyopia.


  • Open Access

    Effect of Disease Severity and Optic Disc Size on Diagnostic Accuracy of RTVue Spectral Domain Optical Coherence Tomograph in Glaucoma

    by Harsha L. Rao, Mauro T. Leite, Robert N. Weinreb, Linda M. Zangwill, Luciana M. Alencar, Pamela A. Sample, Felipe A. Medeiros

    Purpose.: To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. Methods.: 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. Results.: Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNFL thickness, and ganglion cell complex–root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. Conclusions.: Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity.


  • Open Access

    The role of standard automated perimetry and newer functional methods for glaucoma diagnosis and follow-up

    by FelipeA Medeiros, Luciana M Alencar

    Automated perimetry has become the mainstream for assessment of functional glaucomatous loss and progressive damage. Recent improvements with the Swedish interactive thresholding algorithm (SITA) strategy and the guided progression analysis (GPA) have further settled standard achromatic perimetry (SAP) as the preferred method for diagnosis and follow-up of functional loss. Although SAP is still considered the gold standard, function-specific perimetry may offer advantages for early diagnosis. Frequency doubling technology (FDT) and short-wavelength automated perimetry (SWAP) have been shown to be helpful, especially when SAP is normal and there is a suspicion of glaucoma. Studies using rarebit perimetry have also shown promising results. Studies have observed that each test identifies a different subset of eyes, and combining the tests may improve sensitivity. Nevertheless, the more sophisticated analyses do not reduce the importance of a correct interpretation of the test results.