Paolo Orlando
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Paolo Orlando has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
- Maria Luisa Cristina
Department of Health Sciences, University of Genoa, Genoa, Italy
16 shared publications - Anna Maria Spagnolo
Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
10 shared publications Fernanda Perdelli
University of Genova
10 shared publications- Marina Sartini
Operating Unit Hospital Hygiene, Galliera Hospital, Genoa, Italy
7 shared publications - Donatella Panatto
Department of Health Sciences, University of Genoa, 16132 Genoa, Italy
5 shared publications F. Perdelli
Department of Health Sciences, University of Genoa, Italy
5 shared publications
Latest Publications
- 1 February 2014
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 35  (2) , 122-129
The Impact of Aerators on Water Contamination by Emerging Gram-Negative Opportunists in At-Risk Hospital Departments
Objective.: Our aim was to evaluate the impact of aerators on water microbiological contamination in at-risk hospital departments, with a view to quantifying the possible risk of patient exposure to waterborne microorganisms.Design.: We analyzed the microbiological and chemical-physical characteristics of hot and cold water in some critical hospital departments.Setting.: Two hospitals in northern Italy.Methods.: We took 304 water samples over a 1-year period, at 3-month intervals, from taps used by healthcare personnel for handwashing, surgical washing, and the washing of medical equipment. We analyzed heterotrophic plate counts (HPCs) at 36°C and 22°C, nonfastidious gram-negative bacteria (GNB-NE), andLegionella pneumophila.Results.: The percentages of positivity and mean values of HPCs at 22°C, HPCs at 36°C, and GNB-NE loads were significantly higher at outlet points than in the plumbing system. In particular, GNB-NE positivity was higher at outlet points than in the plumbing system in both the cold water (31.58% vs 6.58% of samples were positive) and hot water (21.05% vs 3.95%) supplies. Our results also revealed contamination byL. pneumophilaboth in the plumbing system and at outlet points, with percentages of positive samples varying according to the serogroup examined (serogroups 1 and 2-14). The mean concentrations displayed statistically significant (P< .001) differences between the outlet points (27,382.89 ± 42,245.33 colony-forming units [cfu]/L) and the plumbing system (19,461.84 ± 29,982.11 cfu/L).Conclusions.: These results reveal a high level of contamination of aerators by various species of gram-negative opportunists that are potentially very dangerous for immunocompromised patients and, therefore, the need to improve the management of these devices.
- 1 February 2014
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 35  (2) , 122-129
The Impact of Aerators on Water Contamination by Emerging Gram-Negative Opportunists in At-Risk Hospital Departments
Objective.: Our aim was to evaluate the impact of aerators on water microbiological contamination in at-risk hospital departments, with a view to quantifying the possible risk of patient exposure to waterborne microorganisms.Design.: We analyzed the microbiological and chemical-physical characteristics of hot and cold water in some critical hospital departments.Setting.: Two hospitals in northern Italy.Methods.: We took 304 water samples over a 1-year period, at 3-month intervals, from taps used by healthcare personnel for handwashing, surgical washing, and the washing of medical equipment. We analyzed heterotrophic plate counts (HPCs) at 36°C and 22°C, nonfastidious gram-negative bacteria (GNB-NE), andLegionella pneumophila.Results.: The percentages of positivity and mean values of HPCs at 22°C, HPCs at 36°C, and GNB-NE loads were significantly higher at outlet points than in the plumbing system. In particular, GNB-NE positivity was higher at outlet points than in the plumbing system in both the cold water (31.58% vs 6.58% of samples were positive) and hot water (21.05% vs 3.95%) supplies. Our results also revealed contamination byL. pneumophilaboth in the plumbing system and at outlet points, with percentages of positive samples varying according to the serogroup examined (serogroups 1 and 2-14). The mean concentrations displayed statistically significant (P< .001) differences between the outlet points (27,382.89 ± 42,245.33 colony-forming units [cfu]/L) and the plumbing system (19,461.84 ± 29,982.11 cfu/L).Conclusions.: These results reveal a high level of contamination of aerators by various species of gram-negative opportunists that are potentially very dangerous for immunocompromised patients and, therefore, the need to improve the management of these devices.
- 1 January 2014
- Published by Wolters Kluwer Health in Reviews and Research in Medical Microbiology
- Vol. 25  (1) , 7-14
An overview of carbapenem-resistant Klebsiella pneumoniae
The emergence and dissemination of carbapenem resistance among Enterobacteriaceae, especially Klebsiella pneumoniae, constitute a serious threat to public health, since carbapenems are the agents of last resort in the treatment of life-threatening infections caused by drug-resistant Enterobacteriaceae. In K. pneumoniae, carbapenem resistance was first reported a decade ago and has subsequently emerged in several countries. One particular group of transmissible plasmid-encoded carbapenemase enzymes, designated K. pneumoniae carbapenemase (KPC), confers carbapenem resistance to K. pneumoniae strains and is rapidly spreading worldwide. In addition to KPC-producing K. pneumoniae, several different metallo-β-lactamase-producing strains have been identified. These include New Delhi metallo-β-lactamase, Verona integron-encoded metallo-β-lactamase and imipenemase metallo-β-lactamase. Finally, class D carbapenemases, including oxacillin-type carbapenemases, also occur in K. pneumoniae. Carbapenem-resistant K. pneumoniae (CRKP) can cause several types of healthcare-associated infections, including pneumonia, bloodstream infections, wound or surgical site infections, urinary tract infections and meningitis, and is associated with high mortality rates. Multifactorial intervention, including hand hygiene, contact precautions, patient and staff cohorting, minimizing invasive device use, promoting antimicrobial stewardship, screening, active surveillance testing and chlorhexidine bathing, may be an effective strategy for reducing the nosocomial transmission of CRKP. Moreover, the rapid notification of clinical infection whenever CRKP are identified from clinical specimens allows the timely implementation of control measures.
- 1 January 2014
- Published by Wolters Kluwer Health in Reviews and Research in Medical Microbiology
- Vol. 25  (1) , 7-14
An overview of carbapenem-resistant Klebsiella pneumoniae
The emergence and dissemination of carbapenem resistance among Enterobacteriaceae, especially Klebsiella pneumoniae, constitute a serious threat to public health, since carbapenems are the agents of last resort in the treatment of life-threatening infections caused by drug-resistant Enterobacteriaceae. In K. pneumoniae, carbapenem resistance was first reported a decade ago and has subsequently emerged in several countries. One particular group of transmissible plasmid-encoded carbapenemase enzymes, designated K. pneumoniae carbapenemase (KPC), confers carbapenem resistance to K. pneumoniae strains and is rapidly spreading worldwide. In addition to KPC-producing K. pneumoniae, several different metallo-β-lactamase-producing strains have been identified. These include New Delhi metallo-β-lactamase, Verona integron-encoded metallo-β-lactamase and imipenemase metallo-β-lactamase. Finally, class D carbapenemases, including oxacillin-type carbapenemases, also occur in K. pneumoniae. Carbapenem-resistant K. pneumoniae (CRKP) can cause several types of healthcare-associated infections, including pneumonia, bloodstream infections, wound or surgical site infections, urinary tract infections and meningitis, and is associated with high mortality rates. Multifactorial intervention, including hand hygiene, contact precautions, patient and staff cohorting, minimizing invasive device use, promoting antimicrobial stewardship, screening, active surveillance testing and chlorhexidine bathing, may be an effective strategy for reducing the nosocomial transmission of CRKP. Moreover, the rapid notification of clinical infection whenever CRKP are identified from clinical specimens allows the timely implementation of control measures.
- 1 October 2013
- Published by Wolters Kluwer Health in Reviews and Research in Medical Microbiology
- Vol. 24  (4) , 104-112
The role of the environment in the spread of emerging pathogens in at-risk hospital wards
- 1 October 2013
- Published by Wolters Kluwer Health in Reviews and Research in Medical Microbiology
- Vol. 24  (4) , 104-112
The role of the environment in the spread of emerging pathogens in at-risk hospital wards
- 1 April 2013
- Published by Elsevier in Public Health
- Vol. 127  (4) , 386-391
Multidrug-resistant Acinetobacter baumannii outbreak: an investigation of the possible routes of transmission
- 1 April 2013
- Published by Elsevier in Public Health
- Vol. 127  (4) , 386-391
Multidrug-resistant Acinetobacter baumannii outbreak: an investigation of the possible routes of transmission
- Open Access
- 21 December 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7  (12) , e52809
Can Particulate Air Sampling Predict Microbial Load in Operating Theatres for Arthroplasty?
Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been evaluated and demonstrated in operating theatres. The aim of the present study was to determine whether particle counting could predict microbiological contamination of the air in an operating theatre during 95 surgical arthroplasty procedures. This investigation was carried out over a period of three months in 2010 in an orthopedic operating theatre devoted exclusively to prosthetic surgery. During each procedure, the bacterial contamination of the air was determined by means of active sampling; at the same time, airborne particulate contamination was assessed throughout the entire procedure. On considering the total number of surgical operations, the mean value of the total bacterial load in the center of the operating theatre proved to be 35 CFU/m3; the mean particle count was 4,194,569 no./m3 for particles of diameter ≥0.5 µm and 13,519 no./m3 for particles of diameter ≥5 µm. No significant differences emerged between the median values of the airborne microbial load recorded during the two types of procedure monitored. Particulates with a diameter of ≥0.5 µm were detected in statistically higher concentrations (p<0.001) during knee-replacement procedures. By contrast, particulates with a diameter of ≥5 µm displayed a statistically higher concentration during hip-replacement procedures (p<0.05). The results did not reveal any statistically significant correlation between microbial loads and particle counts for either of the particle diameters considered (≥0.5 µm and ≥5 µm). Consequently, microbiological monitoring remains the most suitable method of evaluating the quality of air in operating theatres.
- 21 December 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7  (12) , e52809
Open AccessCan Particulate Air Sampling Predict Microbial Load in Operating Theatres for Arthroplasty?
Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been evaluated and demonstrated in operating theatres. The aim of the present study was to determine whether particle counting could predict microbiological contamination of the air in an operating theatre during 95 surgical arthroplasty procedures. This investigation was carried out over a period of three months in 2010 in an orthopedic operating theatre devoted exclusively to prosthetic surgery. During each procedure, the bacterial contamination of the air was determined by means of active sampling; at the same time, airborne particulate contamination was assessed throughout the entire procedure. On considering the total number of surgical operations, the mean value of the total bacterial load in the center of the operating theatre proved to be 35 CFU/m3; the mean particle count was 4,194,569 no./m3 for particles of diameter ≥0.5 µm and 13,519 no./m3 for particles of diameter ≥5 µm. No significant differences emerged between the median values of the airborne microbial load recorded during the two types of procedure monitored. Particulates with a diameter of ≥0.5 µm were detected in statistically higher concentrations (p<0.001) during knee-replacement procedures. By contrast, particulates with a diameter of ≥5 µm displayed a statistically higher concentration during hip-replacement procedures (p<0.05). The results did not reveal any statistically significant correlation between microbial loads and particle counts for either of the particle diameters considered (≥0.5 µm and ≥5 µm). Consequently, microbiological monitoring remains the most suitable method of evaluating the quality of air in operating theatres.
- 1 November 2011
- Published by Elsevier in American Journal of Infection Control
- Vol. 39  (9) , 790-794
Spread of multidrug carbapenem-resistant Acinetobacter baumannii in different wards of an Italian hospital
- 1 November 2011
- Published by Elsevier in American Journal of Infection Control
- Vol. 39  (9) , 790-794
Spread of multidrug carbapenem-resistant Acinetobacter baumannii in different wards of an Italian hospital
- 1 October 2008
- Published by Elsevier in Journal of Hospital Infection
- Vol. 70  (2) , 174-179
Evaluation of contamination by blood aerosols produced during various healthcare procedures
- 1 October 2008
- Published by Elsevier in Journal of Hospital Infection
- Vol. 70  (2) , 174-179
Evaluation of contamination by blood aerosols produced during various healthcare procedures
- 1 March 2008
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 211  (1-2) , 213-218
A new microbiological problem in intensive care units: Environmental contamination by MRSA with reduced susceptibility to glycopeptides
- 1 March 2008
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 211  (1-2) , 213-218
A new microbiological problem in intensive care units: Environmental contamination by MRSA with reduced susceptibility to glycopeptides
- 29 January 2008
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 18  (1) , 73-78
Evaluation of environmental contamination by glutaraldehyde in an outpatient facility for digestive endoscopy in an Italian hospital
The potential harmful effects of glutaraldehyde on human health are well known, and in recent years various new substitutes for this compound have been proposed for the disinfection and thorough sterilization of medical instruments. Nevertheless, glutaraldehyde is still widely used in hospital environments. In order to evaluate environmental contamination by glutaraldehyde vapours, the rooms of a hospital out-patient department of digestive endoscopy were monitored in 2005; a total of 52 samples were taken. The mean environmental concentration of glutaraldehyde was 3.7±7.4 μg/m3. The number of efficacious air exchanges per hour was 6.3 v/h in all of the environments monitored. The study revealed that, in a hospital setting, adequate structural and functional planning, combined with responsible management on the part of the personnel and constant careful checking of the results obtained can minimize the risk of occupational exposure to glutaraldehyde.
- 29 January 2008
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 18  (1) , 73-78
Evaluation of environmental contamination by glutaraldehyde in an outpatient facility for digestive endoscopy in an Italian hospital
The potential harmful effects of glutaraldehyde on human health are well known, and in recent years various new substitutes for this compound have been proposed for the disinfection and thorough sterilization of medical instruments. Nevertheless, glutaraldehyde is still widely used in hospital environments. In order to evaluate environmental contamination by glutaraldehyde vapours, the rooms of a hospital out-patient department of digestive endoscopy were monitored in 2005; a total of 52 samples were taken. The mean environmental concentration of glutaraldehyde was 3.7±7.4 μg/m3. The number of efficacious air exchanges per hour was 6.3 v/h in all of the environments monitored. The study revealed that, in a hospital setting, adequate structural and functional planning, combined with responsible management on the part of the personnel and constant careful checking of the results obtained can minimize the risk of occupational exposure to glutaraldehyde.
- 1 March 2007
- Vol. 48  (1) , 17-23
Quality in emergency departments: a study on 3,285,440 admissions.
A multi-centre study has been conducted, during 2005, by means of a questionnaire posted on the Italian Society of Emergency Medicine (SIMEU) web page. Our intention was to carry out an organisational and functional analysis of Italian Emergency Departments (ED) in order to pick out some macro-indicators of the activities performed. Participation was good, in that 69 ED (3,285,440 admissions to emergency services) responded to the questionnaire. The study was based on 18 questions: 3 regarding the personnel of the ED, 2 regarding organisational and functional aspects, 5 on the activity of the ED, 7 on triage and 1 on the assessment of the quality perceived by the users of the ED. The replies revealed that 91.30% of the ED were equipped with data-processing software, which, in 96.83% of cases, tracked the entire itinerary of the patient. About 48,000 patients/year used the ED: 76.72% were discharged and 18.31% were hospitalised. Observation Units were active in 81.16% of the ED examined. Triage programmes were in place in 92.75% of ED: in 75.81% of these, triage was performed throughout the entire itinerary of the patient; in 16.13% it was performed only symptom-based, and in 8.06% only on-call. Of the patients arriving at the ED, 24.19% were assigned a non-urgent triage code, 60.01% a urgent code, 14.30% a emergent code and 1.49% a life-threatening code. Waiting times were: 52.39 min for non-urgent patients, 40.26 min for urgent, 12.08 for emergent, and 1.19 for life-threatening patients.
- 1 March 2007
- Vol. 48  (1) , 17-23
Quality in emergency departments: a study on 3,285,440 admissions.
A multi-centre study has been conducted, during 2005, by means of a questionnaire posted on the Italian Society of Emergency Medicine (SIMEU) web page. Our intention was to carry out an organisational and functional analysis of Italian Emergency Departments (ED) in order to pick out some macro-indicators of the activities performed. Participation was good, in that 69 ED (3,285,440 admissions to emergency services) responded to the questionnaire. The study was based on 18 questions: 3 regarding the personnel of the ED, 2 regarding organisational and functional aspects, 5 on the activity of the ED, 7 on triage and 1 on the assessment of the quality perceived by the users of the ED. The replies revealed that 91.30% of the ED were equipped with data-processing software, which, in 96.83% of cases, tracked the entire itinerary of the patient. About 48,000 patients/year used the ED: 76.72% were discharged and 18.31% were hospitalised. Observation Units were active in 81.16% of the ED examined. Triage programmes were in place in 92.75% of ED: in 75.81% of these, triage was performed throughout the entire itinerary of the patient; in 16.13% it was performed only symptom-based, and in 8.06% only on-call. Of the patients arriving at the ED, 24.19% were assigned a non-urgent triage code, 60.01% a urgent code, 14.30% a emergent code and 1.49% a life-threatening code. Waiting times were: 52.39 min for non-urgent patients, 40.26 min for urgent, 12.08 for emergent, and 1.19 for life-threatening patients.