NMNatalia Y. Makhotkina

Natalia Y. Makhotkina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Natalia Y. Makhotkina has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Tos T. J. M. Berendschot

    University Eye Clinic Maastricht, Maastricht University Medical Centre, Maastricht, The Netherlands

    5 shared publications
  • Rudy M. M. A. Nuijts

    University Eye Clinic Maastricht, Maastricht University Medical Centre Maastricht The Netherlands

    3 shared publications
  • Rudy M.M.A. Nuijts

    From the University Eye Clinic (Makhotkina, Berendschot, Nuijts), Maastricht University Medical Centre, Maastricht, the Netherlands; Rayner Intraocular Lenses Limited (Dugrain, Purchase), West Sussex, United Kingdom

    3 shared publications
  • Bart van Den Borne

    Department of Health Promotion University of Maastricht Maastricht The Netherlands

    2 shared publications
  • Alexander R. H. Weik

    Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands

    1 shared publication
  • Daniel Purchase

    From the University Eye Clinic (Makhotkina, Berendschot, Nuijts), Maastricht University Medical Centre, Maastricht, the Netherlands; Rayner Intraocular Lenses Limited (Dugrain, Purchase), West Sussex, United Kingdom

    1 shared publication

Latest Publications

  • Open Access

    Measuring quality of vision including negative dysphotopsia

    by Natalia Y. Makhotkina, Marjan D. Nijkamp, Tos T. J. M. Berendschot, Bart van Den Borne, Moniek Aelen‐Van Kruchten, Luc van Vught, Jan‐Willem M. Beenakker, Edwin Krijgh, Tariq Aslam, Konrad Pesudovs, et al.

    Purpose: To adapt the Quality of Vision Questionnaire (QoV) for measuring negative dysphotopsia and to validate the original and modified versions in the Dutch population.Methods: The QoV was translated into Dutch according to standardized methodology. Negative dysphotopsia items were constructed based on focus group interviews, literature review and clinical data. The questionnaire was completed by 404 subjects, including contact lens wearers, patients with cataract and after cataract surgery (95.5% with a monofocal, 4.5% with a multifocal intraocular lens). Rasch analysis was applied for evaluation of reliability and validity of the original QoV and modified version, Negative Dysphotopsia QoV (ND‐QoV).Results: The frequency, severity and bothersome scales of the QoV and ND‐QoV demonstrated good measurement precision, good fit statistics for all but one item, but significant mistargeting of more than one logit. Item estimations were stable across the study groups and scales were unidimensional with more than 50% of variance explained by the measurements. There was a positive correlation between questionnaire scores and best corrected visual acuity (r = 0.3, p < 0.01). The quality of vision measured by all three scales was significantly poorer (p < 0.01) in patients with negative dysphotopsia compared to asymptomatic pseudophakic patients.Conclusion: The Dutch version of the QoV questionnaire has shown good psychometric properties comparable to the native version as well as good reliability and validity. The addition of negative dysphotopsia items is a valuable modification for the reliable assessment of quality of vision in pseudophakic patients.


  • Comparability of subjective and objective measurements of nuclear density in cataract patients

    by Natalia Y. Makhotkina, Tos T. J. M. Berendschot, Frank J. H. M. van Den Biggelaar, Alexander R. H. Weik, Rudy M. M. A. Nuijts

    Purpose: To evaluate the relationship between subjective and objective measurements of lens density and the energy of phacoemulsification.Setting: University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands.Design: Cross‐sectional study.Methods: The study population included 69 patients. Nuclear opalescence (NO) was graded with the Lens Opacities Classification System III (LOCS III). Thereafter, lens density was measured objectively with Scheimpflug imaging, anterior segment optical coherent tomography and spectral fundus reflectometry (SFR). Cumulative dissipative energy (CDE) and total ultrasound time (US t.t.) of the phacoemulsification were noted. The relationship between the different measurement techniques and energy of phacoemulsification was assessed using Spearman's correlation coefficients.Results: We found moderate to strong correlations between LOCS III and objective measurements of the lens density (rho's from 0.53 to 0.78, p < 0.05) and a moderate correlation between three objective measurement techniques (rho's between 0.29 and 0.57, p < 0.05). There was a moderate correlation between CDE, US t.t. and lens density measurements (rho's from 0.29 to 0.55, p < 0.05), and the highest correlation was found between CDE and NO scores. Exclusion of patients with advanced cortical and posterior subcapsular opacities improved the correlation between SFR and lens density measurements but not the correlation with the energy of phacoemulsification.Conclusion: Lens Opacities Classification System III has shown the highest correlation with phacoemulsification energy and may be a preferred technique for prediction of use of phacoemulsification energy. Advanced cortical and posterior opacities may interfere with the quality of objective measurements but do not affect the correlation between lens density measurements and phacoemulsification energy.


  • Effect of supplementary implantation of a sulcus-fixated intraocular lens in patients with negative dysphotopsia

    by Natalia Y. Makhotkina, Vincent Dugrain, Daniel Purchase, Tos T.J.M. Berendschot, Rudy M.M.A. Nuijts

    To evaluate whether the outcome of negative dysphotopsia treatment by implantation of a Sulcoflex intraocular lens (IOL) can be understood using individual biometry and optical modeling data. University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands. Retrospective case series. Patients with negative dysphotopsia were treated with supplementary implantation of a sulcus-fixated IOL. Preoperative and postoperative ray-tracing optical models of eyes with negative dysphotopsia were constructed in the Zemax Optic Studio program using individual biometric data. The relationship between biometric parameters, ray-tracing data, and the course of negative dysphotopsia was evaluated. The study comprised 8 patients (10 eyes). After surgery, negative dysphotopsia resolved completely in 6 eyes, partially in 2 eyes, and persisted in 2 eyes. There was no relationship between the course of negative dysphotopsia and age, IOL power, or individual biometry results other than a larger angle κ that was observed in 2 patients with persistent negative dysphotopsia after surgery. Preoperative ray-tracing models showed a decrease in light irradiance at the periphery relative to the center of visual field. After sulcus-fixated IOL implantation, this decrease partially resolved, in particular, for a small pupil aperture (P < .05), and it was more prominent in patients in whom negative dysphotopsia resolved completely than in those with partial or persistent negative dysphotopsia (P = .065 at 1.5 mm aperture). Of all individual biometry results, only angle κ showed a relationship with the course of negative dysphotopsia. In patient-specific optical modeling of sulcus-fixated IOL implantation, the increase in simulated light irradiance at the periphery was related to the course of negative dysphotopsia.


  • Effect of active evaluation on the detection of negative dysphotopsia after sequential cataract surgery: discrepancy between incidences of unsolicited and solicited complaints

    by Natalia Y. Makhotkina, Marjan D. Nijkamp, Tos T.J.M. Berendschot, Bart van Den Borne, Rudy M.M.A. Nuijts

    Purpose: To evaluate the incidence of negative dysphotopsia after sequential cataract surgery.Methods: Retrospective cohort study. The incidence of negative dysphotopsia was assessed by retrospective reviewing of medical records and interviews with patients between 2 and 4 months after sequential cataract surgery. Inclusion criteria were uncomplicated surgery, postoperative corrected distance visual acuity (CDVA) ≥20/25 Snellen and the absence of ocular comorbidity. The majority of intra‐ocular lens (IOL) implants were one‐piece AcrySof SN60WF (161 eyes). Other IOLs (29 eyes) were toric (SN6AT3‐6), spherical (SN60AT), three‐piece (MN60MA) and multifocal (ReSTOR SN6AD1, PanOptix TFNT00 and Finevision Micro F trifocal).Results: The study population was comprised of 95 patients with a mean age of 72 ± 10 years. Unsolicited complaints of negative dysphotopsia were reported by eight patients (8%), and two of them had a resolution of symptoms within 1 month of follow‐up. Eighteen patients (19%) reported negative dysphotopsia at the time of the interview. Two patients reported bothersome negative dysphotopsia, and one of them was successfully treated with implantation of a supplementary IOL in the ciliary sulcus. Patients with negative dysphotopsia were younger than patients without dysphotopsia (p = 0.045) and had shorter axial eye length (p = 0.04), a tendency for higher IOL power (p = 0.09) and a higher CDVA (p = 0.001).Conclusion: The incidence of unsolicited negative dysphotopsia after sequential cataract surgery appears to be a substantial underestimation of complaints identified in active interviewing. Although symptoms are not bothersome in the majority of cases, some patients with undiagnosed severe negative dysphotopsia may benefit from reassurance or secondary treatment.


  • Objective evaluation of negative dysphotopsia with Goldmann kinetic perimetry

    by Natalia Y. Makhotkina, Tos T.J.M. Berendschot, Rudy M.M.A. Nuijts

    To compare the extension of peripheral visual fields in phakic and pseudophakic patients and to evaluate whether Goldmann kinetic perimetry can be used as an objective measure of negative dysphotopsia. University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands. Prospective and case-control study. Kinetic perimetry was performed with V4e and I4e stimuli. Visual fields were assessed in the following 4 quadrants: superior temporal, superior nasal, inferior temporal, and inferior nasal. In the control group, patients were evaluated before and 1 month after cataract surgery. Biometric and perimetric data in the control group were compared with data in the patients with negative dysphotopsia (study group). Each group comprised 10 patients. In the control group, the extension of visual field did not change after surgery. Patients in the study group had a significantly shorter axial length and higher intraocular lens powers than those in the control group. The inferior temporal and inferior nasal quadrants were, respectively, 10 degrees and 6 degrees (P < .05) smaller in the study group than in the control group. In 3 patients with negative dysphotopsia, a shadow was drawn in the superior temporal and the inferior temporal quadrants during perimetry and the position of this shadow matched their subjective description of negative dysphotopsia. The peripheral visual field did not change after cataract surgery in patients without negative dysphotopsia. Kinetic perimetry can be used for objective evaluation of patients with negative dysphotopsia because these patients had constricted peripheral visual fields or a relative temporal scotoma corresponding to the position of the shadow. Proprietary or commercial disclosures are listed after the references.


  • Open Access

    Treatment of negative dysphotopsia with supplementary implantation of a sulcus-fixated intraocular lens

    by Natalia Y. Makhotkina, Tos T. J. M. Berendschot, Henny J. M. Beckers, Rudy M. M. A. Nuijts

    Purpose Our aim was to evaluate the resolution of negative dysphotopsia after supplementary implantation of a sulcus-fixated intraocular lens (IOL). Methods This was a retrospective case series. Patients with severe negative dysphotopsia were treated with supplementary implantation of the Rayner Sulcoflex Aspheric (653 L) IOL. Primary outcome measurements were subjectively reported complaints of dysphotopsia, best corrected distance visual acuity (CDVA), iris-IOL distance, anterior chamber depth (ACD) and volume (ACV), angle opening distance and trabecular-iris space area at 500 and 750 μm. Results A Rayner Sulcoflex IOL was implanted in seven patients (nine eyes) with negative dysphotopsias. Symptoms resolved completely in six eyes, partially in one eye and remained unchanged in two eyes. We did not find any significant changes in CDVA. Angle opening distance, ACD, ACV and iris-IOL distance reduced significantly after Sulcoflex IOL implantation. Conclusions Supplementary implantation of a Sulcoflex IOL can successfully treat negative dysphotopsia. The decrease in anterior segment dimensions in combination with the displacement of light rays by the rounded edges of a Sulcoflex IOL may contribute to the resolution of symptoms.