AAAhmed Mostafa Abdalla

Ahmed Mostafa Abdalla

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ahmed Mostafa Abdalla has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Utilization of UPLC-tandem mass spectrometry for quantitation of colouring matters in dietary formulation

    by Wafaa Abdou Zaghary, Ahmed Mostafa Abdalla, Emily Tawfik Hanna, Marwa Abdel Rahman Tohamy Zanoun

    A simple and sensitive ultra-performance liquid chromatography with Tandem Mass Spectrometric detection (UPLC-MS/MS) method was developed and validated for the simultaneous quantitation of two food colouring matters, Curcumin (CUR) and Riboflavin (RIB). Chromatographic separation was done on Hypersil gold 50×2.1 mm (1.9 μm) column, with gradient programing of mobile phase starting with aqueous 0.1% formic acid and increasing the percentage of 0.1% formic acid in acetonitrile. The utilization of multiple reaction monitoring (MRM) improved the selectivity of detection and decreased the matrix effect. The method was linear in the range of 5-500 ng/mL for CUR and RIB. Intra- and inter-day reproducibility were within the accepted criteria. The method was successfully applied for the determination the laboratory prepared mixtures of the two selected colouring matters. The use of mass spectrometry enhanced the selectivity and sensitivity of detection which allows the robust use of the method in routine quality control tests of the two colouring matters (CUR and RIB).


  • Open Access

    Application of multiple reaction monitoring for quantitation of sweeteners in food products

    by Wafaa Abdou Zaghary, Ahmed Mostafa Abdalla, Emily Tawfik Hanna, Nermeen Abdallah Shoukry

    A coupled UPLC-MS/MS method has been developed and validated for the simultaneous quantitation of food sweeteners stevioside (STV) and aspartame (ASP). Good chromato-graphic separation was achieved on a Hypersil gold 50×2.1 mm (1.9 μm) column, using a gradient flow of 10 mM ammonium acetate, pH = 2.9 adjusted with formic acid, and 10 mM ammonium acetate in acetonitrile:water (95:5, v:v) as the mobile phase. The eluate was introduced to ESI-Mass spectrometer and scanned using multiple reaction monitoring (MRM). The method was robust, reproducible and easy to use and was validated according to ICH guidelines for the accuracy and precision giving acceptable ranges. The utilization of multiple reaction monitoring improved the selectivity of detection. Method was linear in the ranges of 2-250 ng/mL for STV and ASP. Application of this method on laboratory mixtures of the selected sweeteners was successful. The using of mass spectrometry make the method selective and measurement did not affect the presence of impurities, additive and other ingredients of detection due to the simplicity and sensitivity of this method allows the utilization of method in quality control of STV and ASP.

  • Warfarin Poisoning with Delayed Rebound Toxicity

    by Ingrid Berling, Ahmed Mostafa, Jeffrey E. Grice, Michael S. Roberts, Geoffrey K. Isbister


  • Open Access

    Enantiomeric separation and quantitation of warfarin and its metabolites in human plasma by LC-MS/MS

    by Ahmed Abd-Alazim Mostafa

    Enantiomeric separation and quantitation of warfarin and its metabolites in human plasma by LC-MS/MS


  • Open Access

    Novel contribution in online sample cleanup for quantitative determination of Levetiracetam in human plasma by LC-Tandem mass spectrometry

    by Ahmed Abdalazim Mostafa

    The aim of this work was to develop and validate a simple, sensitive and rapid method for the quantitation of levetiracetam (LEV) in plasma using LC-Tandem mass spectrometry. Plasma samples were prepared by simple protein precipitation using acetonitrile; atenolol was used as internal standard (IS). Chromatographic separation was done on Luna 5 µm C18(2) (Phenomenex) 50 × 2.0 mm using gradient flow using solvent A (0.1% formic acid) and solvent B (0.1% formic acid in acetonitrile: water, 95:5, v:v). The positive-ion mass spectrometric detection method utilized electrospray ionization and the multiple reaction monitoring (MRM) mode. The MRM ion transitions were170.9 → 140.8 and 267.3 → 145.1 for levetiracetam and atenolol, respectively. The retention time of levetiracetam and atenolol is 3.24 and 2.96 min, respectively. The total run time was 5 min. The assay was validated over a concentration range from 1 to 100 µg/mL. The method was robust (minimal matrix effect), sensitive (LOQ, 1 µg/mL) metabolites and reproducible (The precision and accuracy for both intra- and inter-day were acceptable <15%). The method can be done on traditional LC-MS equipment. The method was effectively applied to single case study receiving toxic dose of LEV.

  • Open Access

    High lethality and minimal variation after acute self-poisoning with carbamate insecticides in Sri Lanka – implications for global suicide prevention

    by Thomas Lamb, Liza R. Selvarajah, Fahim Mohamed, Shaluka Jayamanne, Indika Gawarammana, Ahmed Mostafa, Nicholas A. Buckley, Michael S. Roberts, Michael Eddleston

    Background: Highly hazardous organophosphorus (OP) insecticides are responsible for most pesticide poisoning deaths. As they are removed from agricultural practice, they are often replaced by carbamate insecticides of perceived lower toxicity. However, relatively little is known about poisoning with these insecticides. Methods: We prospectively studied 1288 patients self-poisoned with carbamate insecticides admitted to six Sri Lankan hospitals. Clinical outcomes were recorded for each patient and plasma carbamate concentration measured in a sample to confirm the carbamate ingested. Findings: Patients had ingested 3% carbofuran powder (719), carbosulfan EC25 liquid (25% w/v, 389), or fenobucarb EC50 liquid (50% w/v, 127) formulations, carbamate insecticides of WHO Toxicity Classes Ib, II, and II, respectively. Intubation and ventilation was required for 183 (14.2%) patients while 71 (5.5%) died. Compared with carbofuran, poisoning with carbosulfan or fenobucarb was associated with significantly higher risk of death [carbofuran 2.2%; carbosulfan 11.1%, OR 5.5 (95% CI 3.0–9.8); fenobucarb 6.3%, OR 3.0 (1.2–7.1)] and intubation [carbofuran 6.1%; carbosulfan 27.0%, OR 5.7 (3.9–8.3); fenobucarb 18.9%, OR 3.6 (2.1–6.1)]. The clinical presentation and cause of death did not differ markedly between carbamates. Median time to death was similar: carbofuran 42.3 h (IQR 5.5–67.3), carbosulfan 21.3 h (11.5–71.3), and fenobucarb 25.3 h (17.3–72.1) (p = 0.99); no patients showed delayed onset of toxicity akin to the intermediate syndrome seen after OP insecticide poisoning. For survivors, median duration of intubation was 67.8 h (IQR 27.5–118.8) with no difference in duration between carbamates. Reduced GCS at presentation was associated with worse outcome although some patients with carbosulfan died after presentation with normal GCS. Conclusions: We did not find carbamate insecticide self-poisoning to vary markedly according to the carbamate ingested although the case fatality varied according to the concentration and formulation of the insecticide. Carbamate poisoning did not appear to be much less toxic than poisoning with some liquid OP insecticide formulations, e.g., chlorpyrifos EC40, that we have previously noted in these same hospitals (Lancet 2005, 366:1452–1459; QJM 2006, 99:513–522). Replacement of WHO Class II Toxicity OP insecticides in agriculture with high-strength liquid carbamate formulations may not substantially reduce case fatality after pesticide poisoning and, therefore, global suicide rates.