Elizabeth Minogue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elizabeth Minogue has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Barry
Nucleic Acid Diagnostics Research Laboratory (NADRL), Microbiology, School of Natural Sciences, National University of Ireland, Galway, Ireland
5 shared publications - Kate Reddington
Nucleic Acid Diagnostics Research Laboratory (NADRL), Microbiology, School of Natural Sciences, National University of Ireland, Galway, Ireland
4 shared publications Nina Tuite
Nucleic Acid Diagnostics Research Laboratory (NADRL), Microbiology, School of Natural Sciences, National University of Ireland, Galway, Ireland
2 shared publications- Cindy Jane Smith
University of Glasgow
1 shared publication - Cyril Carroll
Enteric Pathogen Research Laboratory, Department of Microbiology, National University of Ireland, Galway, Ireland
1 shared publication Eoin Clancy
Microbiology, School of Natural Sciences National University of Ireland Galway Ireland
1 shared publication
Latest Publications
- 23 February 2023
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 77 (4) , 296-310
Design, Development, and Validation of a Culture-Independent Nucleic Acid Diagnostics Method for the Rapid Detection and Quantification of the Burkholderia cepacia Complex in Water with an Equivalence to ISO/TS 12869:2019
In the wake of a series of outbreaks of pharmaceutical finished product related Burkholderia cepacia complex (Bcc) human infections worldwide, the United States Food and Drug Administration (FDA) in 2017, and subsequently in 2021, has issued advisory notifications to the pharmaceutical industry for stringent Bcc testing requirements for pharmaceutical manufacturing processes and for finished pharmaceutical products prior to release to the marketplace. The advisory notifications highlight non-sterile aqueous pharmaceutical finished products as being a major culprit associated with many of these human infection events. As such, there has been a significant number of Bcc contaminated finished product recalls resulting in company revenue losses, delayed finished product release, finished product shortages for patients, manufacturing plant shutdowns coupled with company reputational damage. With many of the finished product recall events, pharmaceutical grade water and / or manufacturing facility water distribution systems have been identified as the primary origin source of Bcc contamination. Testing and monitoring regimes currently employed to identify Bcc contamination of water associated with pharmaceutical manufacturing are often limited by costly, laborious, lengthy and nonspecific traditional microbial culture-based methodologies. Presently FDA approved, European Conformity (CE) marked and International Organization for Standardization (ISO) standard microbial culture-independent rapid, quantitative, specific and sensitive Nucleic Acid Diagnostics (NAD) methodologies are now gaining greater widespread acceptance in their routine usage in testing laboratories. Here we present the development of a rapid (<4 hours from sample in to result out) single test culture-independent Bcc NAD method, incorporating a quantitative real-time Polymerase Chain Reaction (qPCR) assay. This method can be used for the detection and simultaneous identification of all 24 Bcc species currently assigned, directly from water samples. This culture-independent Bcc NAD method is validated to the testing method equivalent of the ISO/TS 12869:2019 standard, which is a widely used rapid culture-independent NAD method for detecting Gram-negative Legionella species in water.
- 23 February 2023
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 77 (4) , 296-310
Design, Development, and Validation of a Culture-Independent Nucleic Acid Diagnostics Method for the Rapid Detection and Quantification of the Burkholderia cepacia Complex in Water with an Equivalence to ISO/TS 12869:2019
In the wake of a series of outbreaks of pharmaceutical finished product related Burkholderia cepacia complex (Bcc) human infections worldwide, the United States Food and Drug Administration (FDA) in 2017, and subsequently in 2021, has issued advisory notifications to the pharmaceutical industry for stringent Bcc testing requirements for pharmaceutical manufacturing processes and for finished pharmaceutical products prior to release to the marketplace. The advisory notifications highlight non-sterile aqueous pharmaceutical finished products as being a major culprit associated with many of these human infection events. As such, there has been a significant number of Bcc contaminated finished product recalls resulting in company revenue losses, delayed finished product release, finished product shortages for patients, manufacturing plant shutdowns coupled with company reputational damage. With many of the finished product recall events, pharmaceutical grade water and / or manufacturing facility water distribution systems have been identified as the primary origin source of Bcc contamination. Testing and monitoring regimes currently employed to identify Bcc contamination of water associated with pharmaceutical manufacturing are often limited by costly, laborious, lengthy and nonspecific traditional microbial culture-based methodologies. Presently FDA approved, European Conformity (CE) marked and International Organization for Standardization (ISO) standard microbial culture-independent rapid, quantitative, specific and sensitive Nucleic Acid Diagnostics (NAD) methodologies are now gaining greater widespread acceptance in their routine usage in testing laboratories. Here we present the development of a rapid (<4 hours from sample in to result out) single test culture-independent Bcc NAD method, incorporating a quantitative real-time Polymerase Chain Reaction (qPCR) assay. This method can be used for the detection and simultaneous identification of all 24 Bcc species currently assigned, directly from water samples. This culture-independent Bcc NAD method is validated to the testing method equivalent of the ISO/TS 12869:2019 standard, which is a widely used rapid culture-independent NAD method for detecting Gram-negative Legionella species in water.
- Open Access
- 18 February 2015
- Published by Springer Nature in BMC Biotechnology
- Vol. 15 (1) , 6
A rapid culture independent methodology to quantitatively detect and identify common human bacterial pathogens associated with contaminated high purity water
Water and High Purity Water (HPW) distribution systems can be contaminated with human pathogenic microorganisms. This biocontamination may pose a risk to human health as HPW is commonly used in the industrial, pharmaceutical and clinical sectors. Currently, routine microbiological testing of HPW is performed using slow and labour intensive traditional microbiological based techniques. There is a need to develop a rapid culture independent methodology to quantitatively detect and identify biocontamination associated with HPW. A novel internally controlled 5-plex real-time PCR Nucleic Acid Diagnostics assay (NAD), was designed and optimised in accordance with Minimum Information for Publication of Quantitative Real-Time PCR Experiments guidelines, to rapidly detect, identify and quantify the human pathogenic bacteria Stenotrophomonas maltophilia, Burkholderia species, Pseudomonas aeruginosa and Serratia marcescens which are commonly associated with the biocontamination of water and water distribution systems. The specificity of the 5-plex assay was tested against genomic DNA isolated from a panel of 95 microorganisms with no cross reactivity observed. The analytical sensitivities of the S. maltophilia, B. cepacia, P. aeruginosa and the S. marcescens assays are 8.5, 5.7, 3.2 and 7.4 genome equivalents respectively. Subsequently, an analysis of HPW supplied by a Millipore Elix 35 water purification unit performed using standard microbiological methods revealed high levels of naturally occurring microbiological contamination. Five litre water samples from this HPW delivery system were also filtered and genomic DNA was purified directly from these filters. These DNA samples were then tested using the developed multiplex real-time PCR NAD assay and despite the high background microbiological contamination observed, both S. maltophilia and Burkholderia species were quantitatively detected and identified. At both sampling points the levels of both S. maltophilia and Burkholderia species present was above the threshold of 10 cfu/100 ml recommended by both EU and US guidelines. The novel culture independent methodology described in this study allows for rapid (<5 h), quantitative detection and identification of these four human pathogens from biocontaminated water and HPW distribution systems. We propose that the described NAD assay and associated methodology could be applied to routine testing of water and HPW distribution systems to assure microbiological safety and high water quality standards.
- 18 February 2015
- Published by Springer Nature in BMC Biotechnology
- Vol. 15 (1) , 6
Open AccessA rapid culture independent methodology to quantitatively detect and identify common human bacterial pathogens associated with contaminated high purity water
Water and High Purity Water (HPW) distribution systems can be contaminated with human pathogenic microorganisms. This biocontamination may pose a risk to human health as HPW is commonly used in the industrial, pharmaceutical and clinical sectors. Currently, routine microbiological testing of HPW is performed using slow and labour intensive traditional microbiological based techniques. There is a need to develop a rapid culture independent methodology to quantitatively detect and identify biocontamination associated with HPW. A novel internally controlled 5-plex real-time PCR Nucleic Acid Diagnostics assay (NAD), was designed and optimised in accordance with Minimum Information for Publication of Quantitative Real-Time PCR Experiments guidelines, to rapidly detect, identify and quantify the human pathogenic bacteria Stenotrophomonas maltophilia, Burkholderia species, Pseudomonas aeruginosa and Serratia marcescens which are commonly associated with the biocontamination of water and water distribution systems. The specificity of the 5-plex assay was tested against genomic DNA isolated from a panel of 95 microorganisms with no cross reactivity observed. The analytical sensitivities of the S. maltophilia, B. cepacia, P. aeruginosa and the S. marcescens assays are 8.5, 5.7, 3.2 and 7.4 genome equivalents respectively. Subsequently, an analysis of HPW supplied by a Millipore Elix 35 water purification unit performed using standard microbiological methods revealed high levels of naturally occurring microbiological contamination. Five litre water samples from this HPW delivery system were also filtered and genomic DNA was purified directly from these filters. These DNA samples were then tested using the developed multiplex real-time PCR NAD assay and despite the high background microbiological contamination observed, both S. maltophilia and Burkholderia species were quantitatively detected and identified. At both sampling points the levels of both S. maltophilia and Burkholderia species present was above the threshold of 10 cfu/100 ml recommended by both EU and US guidelines. The novel culture independent methodology described in this study allows for rapid (<5 h), quantitative detection and identification of these four human pathogens from biocontaminated water and HPW distribution systems. We propose that the described NAD assay and associated methodology could be applied to routine testing of water and HPW distribution systems to assure microbiological safety and high water quality standards.
- Open Access
- 1 September 2014
- Published by Elsevier in Biomolecular Detection and Quantification
- Vol. 1 (1) , 3-7
A current overview of commercially available nucleic acid diagnostics approaches to detect and identify human gastroenteritis pathogens
- 1 September 2014
- Published by Elsevier in Biomolecular Detection and Quantification
- Vol. 1 (1) , 3-7
Open AccessA current overview of commercially available nucleic acid diagnostics approaches to detect and identify human gastroenteritis pathogens
- Open Access
- 1 September 2013
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 40 (9) , 1005-1013
Diagnostics method for the rapid quantitative detection and identification of low-level contamination of high-purity water with pathogenic bacteria
High-purity water (HPW) can be contaminated with pathogenic microorganisms, which may result in human infection. Current culture-based techniques for the detection of microorganisms from HPW can be slow and laborious. The aim of this study was to develop a rapid method for the quantitative detection and identification of pathogenic bacteria causing low-level contamination of HPW. A novel internally controlled multiplex real-time PCR diagnostics assay was designed and optimized to specifically detect and identify Pseudomonas aeruginosa and the Burkholderia genus. Sterile HPW, spiked with a bacterial load ranging from 10 to 103 cfu/100 ml, was filtered and the bacterial cells were removed from the filters by sonication. Total genomic DNA was then purified from these bacteria and subjected to testing with the developed novel multiplex real-time PCR diagnostics assay. The specific P. aeruginosa and Burkholderia genus assays have an analytical sensitivity of 3.5 genome equivalents (GE) and 3.7 GE, respectively. This analysis demonstrated that it was possible to detect a spiked bacterial load of 1.06 × 102 cfu/100 ml for P. aeruginosa and 2.66 × 102 cfu/100 ml for B. cepacia from a 200-ml filtered HPW sample. The rapid diagnostics method described can reliably detect, identify, and quantify low-level contamination of HPW with P. aeruginosa and the Burkholderia genus in <4 h. We propose that this rapid diagnostics method could be applied to the pharmaceutical and clinical sectors to assure the safety and quality of HPW, medical devices, and patient-care equipment.
- 1 September 2013
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 40 (9) , 1005-1013
Open AccessDiagnostics method for the rapid quantitative detection and identification of low-level contamination of high-purity water with pathogenic bacteria
High-purity water (HPW) can be contaminated with pathogenic microorganisms, which may result in human infection. Current culture-based techniques for the detection of microorganisms from HPW can be slow and laborious. The aim of this study was to develop a rapid method for the quantitative detection and identification of pathogenic bacteria causing low-level contamination of HPW. A novel internally controlled multiplex real-time PCR diagnostics assay was designed and optimized to specifically detect and identify Pseudomonas aeruginosa and the Burkholderia genus. Sterile HPW, spiked with a bacterial load ranging from 10 to 103 cfu/100 ml, was filtered and the bacterial cells were removed from the filters by sonication. Total genomic DNA was then purified from these bacteria and subjected to testing with the developed novel multiplex real-time PCR diagnostics assay. The specific P. aeruginosa and Burkholderia genus assays have an analytical sensitivity of 3.5 genome equivalents (GE) and 3.7 GE, respectively. This analysis demonstrated that it was possible to detect a spiked bacterial load of 1.06 × 102 cfu/100 ml for P. aeruginosa and 2.66 × 102 cfu/100 ml for B. cepacia from a 200-ml filtered HPW sample. The rapid diagnostics method described can reliably detect, identify, and quantify low-level contamination of HPW with P. aeruginosa and the Burkholderia genus in <4 h. We propose that this rapid diagnostics method could be applied to the pharmaceutical and clinical sectors to assure the safety and quality of HPW, medical devices, and patient-care equipment.
- 1 October 2012
- Published by Elsevier in Aquaculture
- Vol. 364-365, 329-332
Setting epidemiological cut-off values for Aeromonas salmonicida disc diffusion data capable of discriminating between strains on the basis of their possession of sul1 genes
- 1 October 2012
- Published by Elsevier in Aquaculture
- Vol. 364-365, 329-332
Setting epidemiological cut-off values for Aeromonas salmonicida disc diffusion data capable of discriminating between strains on the basis of their possession of sul1 genes