CAChimezie Anyakora

Chimezie Anyakora

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chimezie Anyakora has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Clinton Ifegwu

    Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Lagos, Lagos, Nigeria. ; Department of Chemistry, Rhodes University, Grahamstown, South Africa

    3 shared publications
  • Nelson Torto

    Rhodes University

    2 shared publications
  • Okechukwu Clinton Ifegwu

    Rhodes University

    2 shared publications
  • Samuel Chigome

    Rhodes University

    2 shared publications
  • Afolabi Adeniyi

    Department of Pharmaceutcal Chemistry, Faculty of Pharmacy, University of Lagos, Lagos, Nigeria

    1 shared publication
  • Akinniyi Osuntoki

    Department of Biochemistry, Faculty of Basic Medical Science, College of Medicine, University of Lagos

    1 shared publication

Latest Publications

  • Open Access

    Excessive active pharmaceutical ingredients in substandard and falsified drugs should also raise concerns in low-income countries

    by Elisa M Maffioli, Marie C Montás, Chimezie Anyakora

    Substandard and falsified (SF) medicines still do not receive enough attention in public health. Substandard medicines are authorised medical products that fail to meet their quality standards or specifications, or both, due to within-factory errors or degradation in supply chains. Falsified medicines, instead, are defined as deliberately and fraudulently misrepresenting medicines’ identity, composition, or source […]


  • Identification and quantification of 19 pharmaceutical active compounds and metabolites in hospital wastewater in Cameroon using LC/QQQ and LC/Q-TOF

    by Edwige Vanessa Tchadji Mayoudom, Evrard Nguidjoe, Rose Ngono Mballa, Olivia Fossi Tankoua, Charles Fokunang, Chimezie Anyakora, Kathleen Ngu Blackett

    Human pharmaceutical residues are a serious environmental concern. They have been reported to have eco, geno, and human toxic effects, and thus their importance as micropollutants cannot be ignored. These have been studied extensively in Europe and North America. However, African countries are still lagging behind in research on these micropollutants. In this study, the wastewaters of the University Teaching Hospital of Yaoundé (UTHY) were screened for the presence of active pharmaceutical ingredients and their metabolites. The screening was carried out using two methods: high-performance liquid chromatography coupled to a triple quadrupole analyzer (LC/QQQ) and high-performance coupled to a mass spectrometer with a time of flight analyzer (LC/Q-TOF). A total of 19 active pharmaceutical ingredients and metabolites were identified and quantified. The compounds identified include paracetamol (211.93 μg/L), ibuprofen (141 μg/L), tramadol (76 μg/L), O-demethyltramadol (141 μg/L), erythromycinanhydrate (7 μg/L), ciprofloxacin (24 μg/L), clarinthromycine (0.088 μg/L), azitromycine (0.39 μg/L), sulfamethoxazole 0.16 μg/L), trimetoprime (0.27 μg/L), caffeine (5.8 μg/L), carnamaeepine (0.94 μg/L), atenolol (0.43 μg/L), propranolol (0.3 μg/L), cimetidine (34 μg/L), hydroxy omeprazole (5 μg/L), diphenhydramine (0.38 μg/L), metformine (154 μg/L), and sucralose (13.07 μg/L).


  • Polycyclic Aromatic Hydrocarbons

    by O C Ifegwu, C Anyakora


  • Open Access

    Electrospun nanofiber sorbents for the pre-concentration of urinary 1-hydroxypyrene

    by Okechukwu Clinton Ifegwu, Chimezie Anyakora, Samuel Chigome, Nelson Torto

    Background: Synthetic polymers have some qualities that make them good candidates for pre concentration of trace analytes biological fluids because of their great potentials to be functionalized and electrospun into nanofibres. Methods: In this study, Electrospun nanofiber sorbents fabricated from 11 polymers {poly(styrene-co-methacrylic acid), poly(styrene-co-divinylbenzene) (SDVB), poly(styrene-co-acrylamide), poly(styrene-co-p-sodium styrene sulfonate), polystyrene, poly(vinyl benzyl chloride), cellulose acetate, polyethylene terephthalate (PET), polysulfone, nylon 6} were evaluated for the extraction and pre-concentration of 1-hydroxypyrene from a water sample. Results: Scanning electron microscopy (SEM) studies revealed the formation of continuous fine bead-free and randomly arrayed fibers with their average diameters ranging from 110 to 650 nm. The percentage recoveries were highest for nylon 6 with 72%, SDVB with 70%, whereas PET achieved the lowest recovery at 34%. Under optimized conditions, the analyte followed a linear relationship for all sorbents in the concentration range of 1 to 1,000 μg/L. The coefficient of determination (r 2) was between 0.9990 to 0.9999, with precision (%relative standard deviation (RSD)) ≤ 9.51% (n = 6) for all the analysis. The %RSD for intra- and inter-day precision at three different concentrations, 10, 25, and 50 μg/L, was ≤7.88% for intraday and ≤8.04% inter-day (3 days), respectively, for all evaluated sorbents. The LOD and LOQ were found to be between 0.054 and 0.16 μg/L and 0.18 and 0.53 μg/L, respectively, using a fluorescent detector. Conclusions: The study suggested that if packed into cartridges, nylon 6 and SDVB nanofiber sorbents could serve as alternatives to the conventional C-18 sorbents in the pre-concentration and clean-up of the tumorigenic biomarker, 1-hydroxypyrene in human urine. The fabrication of selective nanofibers could also extend and simplify sample preparation for organic and biological analytes.


  • Polycyclic Aromatic Hydrocarbons

    by Okechukwu Clinton Ifegwu, Chimezie Anyakora


  • Open Access

    Analysis and identification of oils from seed extract of Anthonotha macrophylla using gas chromatography-mass spectrometry (GC-MS)

    by K. C. Ugoeze, T. Ehianeta, C. Alaribe, C. Anyakora

    The volatile components obtained from the seed extract of Anthonotha Macrophylla were analyzed using gas chromatography-mass spectrometry (GC-MS). Prior to GC-MS analysis, Soxhelt extraction was carried out from the seeds of A. Macrophylla. Agilent GC-MS system comprising 6890GC model coupled with 5973 n mass selective detector was used for analysis. The GC is equipped with Agilent 7673 autosampler and a 30 m 0.25 id DB-1 MS dimethylpolysiolaxane capillary column. The MS source temperature was set at 230C and electron energy at 70V. The ionisation mode was electron ionization and the mass range was 50 to 550 while the scan time was 1 scan/min. The different compounds were identified by matching their mass spectra with the MS spectra in the NIST library. Various compounds were separated and identified but eight of these were at an elevated level. These include: n-hexadecanoic acid, n-octadecadienoic acid; cis-vaccenic acid; octadecanoic acid; hexadecanoic acid 2-hydroxy-1-(hydroxymethyl) ethyl ester; campesterol; stigmasterol and gamma-sitosterol. Key words: Gas chromatography-mass spectrometry, determination, evaluation, composition, Anthonotha macrophylla, seed oil.


  • Open Access

    Application of Nanofiber-packed SPE for Determination of Urinary 1-Hydroxypyrene Level Using HPLC

    by Chimezie Anyakora, Clinton Ifegwu, Nelson Torto, Samuel Chigome

    Application of Nanofiber-packed SPE for Determination of Urinary 1-Hydroxypyrene Level Using HPLC


  • Open Access

    1-Hydroxypyrene Levels in Blood Samples of Rats after Exposure to Generator Fumes

    by Clinton Ifegwu, Miriam N. Igwo-Ezikpe, Chimezie Anyakora, Akinniyi Osuntoki, Kafayat A. Oseni, Eragbae O. Alao

    Polynuclear Aromatic Hydrocarbons (PAHs) are a major component of fuel generator fumes. Carcinogenicity of these compounds has long been established. In this study, 37 Swiss albino rats were exposed to generator fumes at varied distances for 8 hours per day for a period of 42 days and the level of 1-hydroxypyrene in their blood was evaluated. This study also tried to correlate the level of blood 1-hyroxypyrene with the distance from the source of pollution. Plasma was collected by centrifuging the whole blood sample followed by complete hydrolysis of the conjugated 1-hydroxypyrene glucuronide to yield the analyte of interest, 1-hydroxypyrene, which was achieved using beta glucuronidase. High performance liquid chromatography (HPLC) with UV detector was used to determine the 1-hydroxypyrene concentrations in the blood samples. The mobile phase was water:methanol (12:88 v/v) isocratic run at the flow rate of 1.2 mL/min with CI8 stationary phase at 250 run. After 42 days of exposure, blood concentration level of 1-hydroxypyrene ranged from 34 μg/mL to 26.29 μg/mL depending on the distance from source of exposure. The control group had no 1-hydroxypyrene in their blood. After the period of exposure, percentage of death correlated with the distance from the source of exposure. Percentage of death ranged from 56% to zero depending on the proximity to source of pollution.


  • Open Access

    Urinary 1-Hydroxypyrene as a Biomarker to Carcinogenic Polycyclic Aromatic Hydrocarbon Exposure

    by Clinton Ifegwu, Kayode Osunjaye, Folasade Fashogbon, Kolawole Oke, Afolabi Adeniyi, Chimezie Anyakora

    In order to capture the extent of exposure to polycyclic aromatic hydrocarbons (PAHs), various biomarkers have been employed. The biomarkers employed for PAHs include PAHs genetoxic end points in lymphocytes, urinary metabolites, PAH-DNA adducts, and PAH-Protein adducts. Of these, excretory 1-hydroxypyene, a metabolite of pyrene, has been used extensively as a biological monitoring indicator of exposure to PAHs. This study attempts to assess the level of this biomarker in the body fluid of 68 exposed subjects using high performance liquid chromatography HPLC. The subjects screened included auto mechanics, drivers, and fuel attendants. 1-hydroxypyrene was extracted from the urine of the subjects using solid phase extraction method. The HPLC analysis was done in isocratic mode using water:methanol (12:88 v/v) mobile phase. The stationary phase was XBridge C18 (150 × 4.6 mm) 5 μm column. The wavelength was 250 nm at a flow rate of 1.2 mL/min. The oven temperature was 30 °C and the injection volume was 20 μL. The run time was 3 minutes. The level of urinary 1-hydroxypyrene detected varied for the different categories of occupation studied. About 27% of sampled fuel attendants and 22% of auto mechanics had detectable 1-hydroxypyrene in their urine samples. There was no detectable 1-hydroxypyene in the urine samples of commercial drivers or in the urine samples of students used as controls. The results of this study showed that fuel attendants and auto mechanics have significant exposures to PAHs. So far, there is no established benchmark for level of PAHs in urine, but our findings indicate the possibility of future cancer cases in this population as a result of their occupational exposure. The study was not able to link the level of 1-hydroxypyene with the smoking habits of the subjects.