LBLaura Becerra-Fajardo

Laura Becerra-Fajardo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Laura Becerra-Fajardo has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Invasive and Non-Invasive Remote Patient Monitoring Devices for Heart Failure: A Comparative Review of Technical Maturity and Clinical Readiness

    by Ivan Luque, Mar Gadea, Anna Comas, Laura Becerra-Fajardo, Javier Colás, Antoni Ivorra

    Heart failure (HF) represents a growing public health concern, driven by rising prevalence and the challenge of frequent, costly (re-)hospitalizations from decompensation. To address these, HF management has progressed towards incorporating devices for remote patient monitoring (RPM), with most being focused on identifying decompensation and providing timely, tailored pharmacological interventions. To date, the pool of devices has enlarged substantially, forming a spectrum of invasive and non-invasive options whose clinical adoption potential is yet to be determined. This review summarizes existing devices for RPM in HF care, with a major focus on technical characteristics and potential clinical efficacy. To unify the two traditionally separated groups, we re-classify the sampled devices in a single taxonomical dimension, the physical location of the sensing element(s), and objectively assess their current development state using the Medical Device Readiness Level, a metric that merges technical and clinical perspectives. Furthermore, we outline additional evaluative metrics within two complementary dimensions, focused on process efficiency and patient outcomes, ultimately offering a structured framework to evaluate clinical adoption.


  • Open Access

    The biomedical engineer’s pledge: overview and context

    by Antoni Ivorra, Txetxu Ausín, Laura Becerra-Fajardo, Antonio J. del Ama, Jesús Minguillón, Aracelys García-Moreno, Jordi Aguiló, Filipe Oliveira Barroso, Bart Bijnens, Oscar Camara, et al.

    Although biomedical engineering (BME) is a profession with ethical responsibilities comparable to those in medicine, it has, until now, lacked a counterpart to the Hippocratic Oath. While professional societies have established codes of ethics for biomedical engineers, these documents lack the symbolic and ceremonial significance of an oath or pledge. By contrast, the recitation of the Hippocratic Oath, or its modern version, the “Physician’s Pledge,” serves as a powerful rite of passage for medical students, fostering a strong sense of ethical duty at the start of their professional journey. However, the content of the Hippocratic Oath includes elements specific to clinical practice and is not directly applicable to biomedical engineering. To fill this gap, we have created a “Biomedical Engineer’s Pledge,” comprising a preamble, ten promises, and a concluding statement, to inspire ethical awareness and establish a meaningful graduation tradition. Graphical abstract


  • Open Access

    First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction

    by Laura Becerra-Fajardo, Jesus Minguillon, Marc Oliver Krob, Camila Rodrigues, Miguel González- Sánchez, Álvaro Megía-García, Carolina Redondo Galán, Francisco Gutiérrez Henares, Albert Comerma, Antonio J. Del-Ama, et al.

    Background: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. Methods: A proof-of-concept device, consisting of implantable thin-film electrodes and a non-implantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. Results: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. Conclusions: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics.

  • Open Access

    Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents

    by Aracelys García-Moreno, Albert Comerma-Montells, Marc Tudela-Pi, Jesus Minguillon, Laura Becerra-Fajardo, Antoni Ivorra

    Objective. To develop and in vivo demonstrate threadlike wireless implantable neuromuscular microstimulators that are digitally addressable. Approach. These devices perform, through its two electrodes, electronic rectification of innocuous high frequency current bursts delivered by volume conduction via epidermal textile electrodes. By avoiding the need of large components to obtain electrical energy, this approach allows the development of thin devices that can be intramuscularly implanted by minimally invasive procedures such as injection. For compliance with electrical safety standards, this approach requires a minimum distance, in the order of millimeters or a very few centimeters, between the implant electrodes. Additionally, the devices must cause minimal mechanical damage to tissues, avoid dislocation and be adequate for long-term implantation. Considering these requirements, the implants were conceived as tubular and flexible devices with two electrodes at opposite ends and, at the middle section, a hermetic metallic capsule housing the electronics. Main results. The developed implants have a submillimetric diameter (0.97 mm diameter, 35 mm length) and consist of a microcircuit, which contains a single custom-developed integrated circuit, housed within a titanium capsule (0.7 mm diameter, 6.5 mm length), and two platinum–iridium coils that form two electrodes (3 mm length) located at opposite ends of a silicone body. These neuromuscular stimulators are addressable, allowing to establish a network of microstimulators that can be controlled independently. Their operation was demonstrated in an acute study by injecting a few of them in the hind limb of anesthetized rabbits and inducing controlled and independent contractions. Significance. These results show the feasibility of manufacturing threadlike wireless addressable neuromuscular stimulators by using fabrication techniques and materials well established for chronic electronic implants. Although long-term operation still must be demonstrated, the obtained results pave the way to the clinical development of advanced motor neuroprostheses formed by dense networks of such wireless devices.


  • Powering Electronic Implants by High Frequency Volume Conduction: In Human Validation

    by Jesus Minguillon, Marc Tudela-Pi, Laura Becerra-Fajardo, Enric Perera-Bel, Antonio J. Del-Ama, Angel Gil-Agudo, Alvaro Megia-Garcia, Aracelys Garcia-Moreno, Antoni Ivorra

    Objective: Wireless power transfer (WPT) is used as an alternative to batteries to accomplish miniaturization in electronic medical implants. However, established WPT methods require bulky parts within the implant or cumbersome external systems, hindering minimally invasive deployments and the development of networks of implants. As an alternative, we propose a WPT approach based on volume conduction of high frequency (HF) current bursts. These currents are applied through external electrodes and are collected by the implants through two electrodes at their opposite ends. This approach avoids bulky components, enabling the development of flexible threadlike implants. Methods: We study in humans if HF (6.78 MHz) current bursts complying with safety standards and applied through two textile electrodes strapped around a limb can provide substantial powers from pairs of implanted electrodes. Results: Time averaged electric powers obtained from needle electrodes (diameter = 0.4 mm, length = 3 mm, separation = 30 mm) inserted into arms and lower legs of five healthy participants were 5.9 ± 0.7 mW and 2.4 ± 0.3 mW respectively. We also characterize the coupling between the external system and the implants using personalized two-port impedance models generated from medical images. Conclusions: The results demonstrate that innocuous and imperceptible HF current bursts that flow through the tissues by volume conduction can be used to wirelessly power threadlike implants. Significance: This is the first time that WPT based on volume conduction is demonstrated in humans. This method overcomes the limitations of existing WPT methods in terms of minimal invasiveness and usability.


  • Open Access

    Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics

    by Laura Becerra-Fajardo, Marc Oliver Krob, Jesus Minguillon, Camila Rodrigues, Christine Welsch, Marc Tudela-Pi, Albert Comerma, Filipe Oliveira Barroso, Andreas Schneider, Antoni Ivorra

    Background: Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods: We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results: The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions: The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices.


  • Open Access

    Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents

    by Aracelys García-Moreno, Albert Comerma-Montells, Marc Tudela-Pi, Jesus Minguillon, Laura Becerra-Fajardo, Antoni Ivorra

    Objective: To develop and in vivo demonstrate threadlike wireless implantable neuromuscular microstimulators that are digitally addressable. Approach: These devices perform, through its two electrodes, electronic rectification of innocuous high frequency current bursts delivered by volume conduction via epidermal textile electrodes. By avoiding the need of large components to obtain electrical energy, this approach allows the development of thin devices that can be intramuscularly implanted by minimally invasive procedures such as injection. For compliance with electrical safety standards, this approach requires a minimum distance, in the order of millimeters or a very few centimeters, between the implant electrodes. Additionally, the devices must cause minimal mechanical damage to tissues, avoid dislocation and be adequate for long-term implantation. Considering these requirements, the implants were conceived as tubular and flexible devices with two electrodes at opposite ends and, at the middle section, a hermetic metallic capsule housing the electronics. Main results: The developed implants have a submillimetric diameter (0.97 mm diameter, 35 mm length) and consist of a microcircuit, which contains a single custom-developed integrated circuit, housed within a titanium capsule (0.7 mm diameter, 6.5 mm length), and two platinum-iridium coils that form two electrodes (3 mm length) located at opposite ends of a silicone body. These neuromuscular stimulators are addressable, allowing to establish a network of microstimulators that can be controlled independently. Their operation was demonstrated by injecting a few of them in the hind limb of anesthetized rabbits and inducing controlled and independent contractions. Significance: These results show the feasibility of manufacturing threadlike wireless addressable neuromuscular stimulators by using fabrication techniques and materials well established for chronic electronic implants. This paves the way to the clinical development of advanced motor neuroprostheses formed by dense networks of such wireless devices.

  • Open Access

    Floating EMG Sensors and Stimulators Wirelessly Powered and Operated by Volume Conduction for Networked Neuroprosthetics

    by Laura Becerra-Fajardo, Marc Oliver Krob, Jesus Minguillon, Camila Rodrigues, Christine Welsch, Marc Tudela-Pi, Albert Comerma, Filipe Oliveira Barroso, Andreas Schneider, Antoni Ivorra

    Background: Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods: We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results: The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions: The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices.

  • In Vitro Evaluation of a Protocol and an Architecture for Bidirectional Communications in Networks of Wireless Implants Powered by Volume Conduction

    by Laura Becerra-Fajardo, Jesus Minguillon, Camila Rodrigues, Filipe O. Barroso, José L. Pons, Antoni Ivorra

  • Open Access

    Volume Conduction for Powering Deeply Implanted Networks of Wireless Injectable Medical Devices: A Numerical Parametric Analysis

    by Marc Tudela-Pi, Jesus Minguillon, Laura Becerra-Fajardo, Antoni Ivorra

    The use of networks of wireless active implantable medical devices (AIMDs) could revolutionize the way that numerous severe illnesses are treated. However, the development of sub-mm AIMDs is hindered by the bulkiness and the transmission range that consolidated wireless power transfer (WPT) methods exhibit. The aim of this work is to numerically study and illustrate the potential of an innovative WPT technique based on volume conduction at high frequencies for powering AIMDs. In this technique, high frequency currents are coupled into the tissues through external electrodes, producing an electric field that can be partially picked-up by thin, flexible, and elongated implants. In the present study, the system formed by the external electrodes, the tissues and the implants was modeled as a two-port impedance network. The parameters of this model were obtained using a numerical solver based on the finite element method (fem). The model was used to determine the power delivered to the implants’ load (PDL) and the power transmission efficiency (PTE) of the system. The results allow the identification of the main features that influence the PDL and the PTE in a volume conduction scenario and demonstrate that volume conduction at high frequencies can be the basis for a non-focalized WPT method that can transfer powers above milliwatts to multiple mm-sized implants (< 10 mm 3 ) placed several centimeters (>3 cm) inside the tissues.