Nibu A. George
Nibu A. George has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Nibu B. Thomas
Physics Research Centre, Baselius College, Kottayam, India
4 shared publicationsC P G Vallabhan
International School of Photonics, Cochin University of Science and Technology, Cochin 682022, India
3 shared publicationsGerhard Rakhorst
3 shared publicationsQingjun Qiu
3 shared publicationsA K George
Physics Department, College of Science, Sultan Qaboos University, PO Box 36, Postal Code 123, Muscat, Oman
2 shared publications- Balakrishnan Nair Aneeshkumar
International School of Photonics, Cochin University of Science and Technology, Cochin 682022, India
2 shared publications
Latest Publications
- 9 December 2024
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 139 (12) , 1-20
Network analysis of research articles on mural paintings
- 9 December 2024
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 139 (12) , 1-20
Network analysis of research articles on mural paintings
- 3 June 2024
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 139 (6) , 1-14
Enhanced antimicrobial properties of mural colours by the addition of titanium dioxide nanoparticles
- 3 June 2024
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 139 (6) , 1-14
Enhanced antimicrobial properties of mural colours by the addition of titanium dioxide nanoparticles
- Open Access
- 1 January 2020
- Published by IOP Publishing in Materials Research Express
- Vol. 7 (1) , 015064
Enhanced thermal diffusivity of water in the presence of iron oxide nanoparticles: a laser induced thermal lens measurement
Iron oxide nanoparticles are prepared using co-precipitation method and its thermal diffusivity as a function of concentration in distilled water is measured using laser induced thermal lens technique. The morphology, distribution and particle size are determined using SEM measurements. The elemental composition and optical properties of the sample are obtained from EDAX and UV–visible absorption spectra. It is found that the thermal diffusivity of the nanoparticle solution is larger than that of pure water at low concentrations but it is decreasing with increase in concentration of the nanoparticles. Variation of electrical conductivity and magnetic susceptibility of the same sample are also studied.
- 1 January 2020
- Published by IOP Publishing in Materials Research Express
- Vol. 7 (1) , 015064
Open AccessEnhanced thermal diffusivity of water in the presence of iron oxide nanoparticles: a laser induced thermal lens measurement
Iron oxide nanoparticles are prepared using co-precipitation method and its thermal diffusivity as a function of concentration in distilled water is measured using laser induced thermal lens technique. The morphology, distribution and particle size are determined using SEM measurements. The elemental composition and optical properties of the sample are obtained from EDAX and UV–visible absorption spectra. It is found that the thermal diffusivity of the nanoparticle solution is larger than that of pure water at low concentrations but it is decreasing with increase in concentration of the nanoparticles. Variation of electrical conductivity and magnetic susceptibility of the same sample are also studied.
- 18 July 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (15) , 18056-18057
Enhancement of nonlinear optical properties of BaTiO_3 nanoparticles by the addition of silver seeds: comment
This is a comment on the previously published paper “Enhancement of nonlinear optical properties of BaTiO3 nanoparticles by the addition of silver seeds,” [Opt. Express 20, 26511 (2012) [CrossRef] ]. An erroneous equation given in the manuscript is corrected with a more accurate equation in this comment.
- 18 July 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (15) , 18056-18057
Enhancement of nonlinear optical properties of BaTiO_3 nanoparticles by the addition of silver seeds: comment
This is a comment on the previously published paper “Enhancement of nonlinear optical properties of BaTiO3 nanoparticles by the addition of silver seeds,” [Opt. Express 20, 26511 (2012) [CrossRef] ]. An erroneous equation given in the manuscript is corrected with a more accurate equation in this comment.
- 30 January 2015
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 30 (2) , 165-170
Single-beam thermal lens measurement of thermal diffusivity of engine coolants
Automobile engine coolant liquids are commonly used for efficient heat transfer from the engine to the surroundings. In this work we have investigated the thermal diffusivity of various commonly available engine coolants in Indian automobile market. We have used single beam laser induced thermal lens technique for the measurements. Engine coolants are generally available in concentrated solution form and are recommended to use at specified dilution. We have investigated the samples in the entire recommended concentration range for the use in radiators. While some of the brands show an enhanced thermal diffusivity compared to pure water, others show slight decrease in thermal diffusivity.
- 30 January 2015
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 30 (2) , 165-170
Single-beam thermal lens measurement of thermal diffusivity of engine coolants
Automobile engine coolant liquids are commonly used for efficient heat transfer from the engine to the surroundings. In this work we have investigated the thermal diffusivity of various commonly available engine coolants in Indian automobile market. We have used single beam laser induced thermal lens technique for the measurements. Engine coolants are generally available in concentrated solution form and are recommended to use at specified dilution. We have investigated the samples in the entire recommended concentration range for the use in radiators. While some of the brands show an enhanced thermal diffusivity compared to pure water, others show slight decrease in thermal diffusivity.
- 22 April 2013
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 28 (4) , 313-320
A simple optical sensor for the measurement of dry rubber content in natural rubber latex
In this article, we report a new method to measure dry rubber content (DRC) in natural latex using a light scattering principle. Latex collected from the field, without diluting or any other chemical processing, can be directly used in this technique to measure its DRC. A laser beam transmitted through a thin column of latex is imaged using a digital camera and the image is processed to calculate the strength of scattering. We have observed a linear relationship between the DRC of the latex and the full width at half of the maximum of the laser beam intensity profile. The method requires only a very small quantity (about 0.5 g) of latex and the measurement is very fast, taking only a few minutes. Although we have demonstrated the described method for latex characterisation, this method can be extended for turbidity/particle concentration measurement of any heavily scattering liquids.
- 22 April 2013
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 28 (4) , 313-320
A simple optical sensor for the measurement of dry rubber content in natural rubber latex
In this article, we report a new method to measure dry rubber content (DRC) in natural latex using a light scattering principle. Latex collected from the field, without diluting or any other chemical processing, can be directly used in this technique to measure its DRC. A laser beam transmitted through a thin column of latex is imaged using a digital camera and the image is processed to calculate the strength of scattering. We have observed a linear relationship between the DRC of the latex and the full width at half of the maximum of the laser beam intensity profile. The method requires only a very small quantity (about 0.5 g) of latex and the measurement is very fast, taking only a few minutes. Although we have demonstrated the described method for latex characterisation, this method can be extended for turbidity/particle concentration measurement of any heavily scattering liquids.
- 3 June 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (13) , 3955-3977
Depth-kymography of vocal fold vibrations: part II. Simulations and direct comparisons with 3D profile measurements
We report novel direct quantitative comparisons between 3D profiling measurements and simulations of human vocal fold vibrations. Until now, in human vocal folds research, only imaging in a horizontal plane was possible. However, for the investigation of several diseases, depth information is needed, especially when the two folds act differently, e.g. in the case of tumour growth. Recently, with our novel depth-kymographic laryngoscope, we obtained calibrated data about the horizontal and vertical positions of the visible surface of the vibrating vocal folds. In order to find relations with physical parameters such as elasticity and damping constants, we numerically simulated the horizontal and vertical positions and movements of the human vocal folds while vibrating and investigated the effect of varying several parameters on the characteristics of the phonation: the masses and their dimensions, the respective forces and pressures, and the details of the vocal tract compartments. Direct one-to-one comparison with measured 3D positions presents-for the first time-a direct means of validation of these calculations. This may start a new field in vocal folds research.
- 3 June 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (13) , 3955-3977
Depth-kymography of vocal fold vibrations: part II. Simulations and direct comparisons with 3D profile measurements
We report novel direct quantitative comparisons between 3D profiling measurements and simulations of human vocal fold vibrations. Until now, in human vocal folds research, only imaging in a horizontal plane was possible. However, for the investigation of several diseases, depth information is needed, especially when the two folds act differently, e.g. in the case of tumour growth. Recently, with our novel depth-kymographic laryngoscope, we obtained calibrated data about the horizontal and vertical positions of the visible surface of the vibrating vocal folds. In order to find relations with physical parameters such as elasticity and damping constants, we numerically simulated the horizontal and vertical positions and movements of the human vocal folds while vibrating and investigated the effect of varying several parameters on the characteristics of the phonation: the masses and their dimensions, the respective forces and pressures, and the details of the vocal tract compartments. Direct one-to-one comparison with measured 3D positions presents-for the first time-a direct means of validation of these calculations. This may start a new field in vocal folds research.
- 1 November 2008
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 13 (06) , 064024-064024-5
New laryngoscope for quantitative high-speed imaging of human vocal folds vibration in the horizontal and vertical direction
We report the design of a novel laser line-triangulation laryngoscope for the quantitative visualization of the three-dimensional movements of human vocal folds during phonation. This is the first successful in vivo recording of the three-dimensional movements of human vocal folds in absolute values. Triangulation images of the vocal folds are recorded at the rate of with a resolution of . A special image-processing algorithm is developed to precisely follow the subpixel movements of the laser line image. Vibration profiles in both horizontal and vertical directions are calibrated and measured in absolute SI units with a resolution of . We also present a movie showing the vocal folds dynamics in vertical cross section.- 1 November 2008
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 13 (06) , 064024-064024-5
New laryngoscope for quantitative high-speed imaging of human vocal folds vibration in the horizontal and vertical direction
We report the design of a novel laser line-triangulation laryngoscope for the quantitative visualization of the three-dimensional movements of human vocal folds during phonation. This is the first successful in vivo recording of the three-dimensional movements of human vocal folds in absolute values. Triangulation images of the vocal folds are recorded at the rate of with a resolution of . A special image-processing algorithm is developed to precisely follow the subpixel movements of the laser line image. Vibration profiles in both horizontal and vertical directions are calibrated and measured in absolute SI units with a resolution of . We also present a movie showing the vocal folds dynamics in vertical cross section.