David H. Barnett
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David H. Barnett has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
A. A. Neuber
Texas Tech Univ, Dept Elect & Comp Engn, Ctr Pulsed Power & Power Elect, Lubbock, TX 79409 USA
4 shared publications- John Mankowski
Center for Pulsed Power and Power Electronics, Texas Tech University, Lubbock, TX 79409, USA
4 shared publications J. C. Dickens
Texas Tech Univ, Dept Elect & Comp Engn, Ctr Pulsed Power & Power Elect, Lubbock, TX 79409 USA
3 shared publications- James Dickens
Center for Pulsed Power and Power Electronics, Texas Tech University, Lubbock, TX 79409, USA
2 shared publications K. Rainwater
Texas Tech Univ, Dept Elect & Comp Engn, Ctr Pulsed Power & Power Elect, Lubbock, TX 79409 USA
2 shared publications- Andreas Neuber
Center for Pulsed Power and Power Electronics, Texas Tech University, Lubbock, TX 79409, USA
1 shared publication
Latest Publications
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (6) , 2163-2174
Investigation of Lightning Attachment Risks to Small Structures Associated With the Electrogeometric Model (EGM)
A 3-D Monte Carlo-type random walk model was constructed for the assessment of lightning attachment probabilities to small structures. The simulation assumed buildings had a negligible impact on the propagation of lightning. A purely stochastic propagation model based on a previously proposed gas and charged particle diffusion process was employed. The attachment was based on the electrogeometric model in which striking distance is determined by return stroke peak current. This model allows for hundreds of thousands of samples to be evaluated in the window of a few minutes on readily available consumer computing hardware. Using this model, it became possible to enable characterizing building protection as a probability distribution of striking distance. Such was done to provide a deeper understanding of the impact of building protection design choices than is readily available from binary testing. The model was calibrated for minimum input resolution, which is found to be insensitive to variations in step length and moderately insensitive to variations in propagation angle distribution, resulting in normalized errors of less than 15% (rms). A parametric sweep of geometric features was performed for a large (100 m x 50 m) rectangular building with catenary wire protection. For heights of less than 30 m, lightning was found to bypass protection structures and strike to the building itself at rates that were insensitive to variations in building height. The extent to which the protection may be recessed from the building's perimeter was found to have a significant impact. Variations in building aspect ratio were found to be of limited impact except for cases of extreme aspect ratio where competition with the ground appears to have resulted in much better lightning protection performance.
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (6) , 2163-2174
Investigation of Lightning Attachment Risks to Small Structures Associated With the Electrogeometric Model (EGM)
A 3-D Monte Carlo-type random walk model was constructed for the assessment of lightning attachment probabilities to small structures. The simulation assumed buildings had a negligible impact on the propagation of lightning. A purely stochastic propagation model based on a previously proposed gas and charged particle diffusion process was employed. The attachment was based on the electrogeometric model in which striking distance is determined by return stroke peak current. This model allows for hundreds of thousands of samples to be evaluated in the window of a few minutes on readily available consumer computing hardware. Using this model, it became possible to enable characterizing building protection as a probability distribution of striking distance. Such was done to provide a deeper understanding of the impact of building protection design choices than is readily available from binary testing. The model was calibrated for minimum input resolution, which is found to be insensitive to variations in step length and moderately insensitive to variations in propagation angle distribution, resulting in normalized errors of less than 15% (rms). A parametric sweep of geometric features was performed for a large (100 m x 50 m) rectangular building with catenary wire protection. For heights of less than 30 m, lightning was found to bypass protection structures and strike to the building itself at rates that were insensitive to variations in building height. The extent to which the protection may be recessed from the building's perimeter was found to have a significant impact. Variations in building aspect ratio were found to be of limited impact except for cases of extreme aspect ratio where competition with the ground appears to have resulted in much better lightning protection performance.
- 15 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (2) , 1472-1476
A Reflex Triode System With Multicavity Adjustment
- 15 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (2) , 1472-1476
A Reflex Triode System With Multicavity Adjustment
- 8 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Compact reflex triode with multi cavity adjustment
Summary form only given. This study focuses on the achieving wide tunabiltiy of a compact reflex triode virtual cathode oscillator (vircator). The cathode is of a bimodal carbon fiber (CF) material paired with a pyrolytic graphite anode. These materials where chosen for their operating characteristics which including but not limited to, long lifetime > 106 shots, high operating temperatures > 1000 K, and large current densities ~200 A/cm3. A 12 stage, 158 J pulse forming network (PFN) based Marx generator serves to drive the Vircator at 350 kV, 4 kA with ~100 ns pulsewidth. The operating frequency of interest is in the range of 1-6 GHz, where the tunability is achieved by varying the size of the anode-cathode (A-K) gap, the length from the back wall to the A-K gap, or/and the distance from the bottom of the cavity to the A-K gap. The primary focus in this experiment was to increase the achievable frequencies by placing a square waveguide within a sealed vacuum tube. This allows the bottom part of the waveguide to be easily adjusted while still maintaining the waveguide integrity. The resulting microwave frequencies are shown along with the systems performance.
- 8 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Compact reflex triode with multi cavity adjustment
Summary form only given. This study focuses on the achieving wide tunabiltiy of a compact reflex triode virtual cathode oscillator (vircator). The cathode is of a bimodal carbon fiber (CF) material paired with a pyrolytic graphite anode. These materials where chosen for their operating characteristics which including but not limited to, long lifetime > 106 shots, high operating temperatures > 1000 K, and large current densities ~200 A/cm3. A 12 stage, 158 J pulse forming network (PFN) based Marx generator serves to drive the Vircator at 350 kV, 4 kA with ~100 ns pulsewidth. The operating frequency of interest is in the range of 1-6 GHz, where the tunability is achieved by varying the size of the anode-cathode (A-K) gap, the length from the back wall to the A-K gap, or/and the distance from the bottom of the cavity to the A-K gap. The primary focus in this experiment was to increase the achievable frequencies by placing a square waveguide within a sealed vacuum tube. This allows the bottom part of the waveguide to be easily adjusted while still maintaining the waveguide integrity. The resulting microwave frequencies are shown along with the systems performance.
- 1 August 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (8) , 084702
Material selection of a ferrimagnetic loaded coaxial delay line for phasing gyromagnetic nonlinear transmission lines
Implementing nonlinear transmission line (NLTL) technology in the design of a high power microwave source has the benefits of producing a comparatively small and lightweight solid-state system where the emission frequency is easily tuned. Usually, smaller in physical size, single NLTLs may produce significantly less power than its vacuum based counterparts. However, combining individual NLTL outputs electrically or in free-space is an attractive solution to achieve greater output power. This paper discusses a method for aligning a four element NLTL antenna array with coaxial geometry using easily adjustable temporal delay lines. These delay lines, sometimes referred to as pulse shock lines or pulse sharpening lines, are placed serially in front of the main NLTL line. The propagation velocity in each delay line is set by the voltage amplitude of an incident pulse as well as the magnetic field bias. Each is adjustable although for the system described in this paper, the voltage is held constant while the bias is changed through applying an external DC magnetic field of varying magnitude. Three different ferrimagnetic materials are placed in the temporal delay line to evaluate which yields the greatest range of electrical delay with the least amount of variability from consecutive shots.
- 1 August 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (8) , 084702
Material selection of a ferrimagnetic loaded coaxial delay line for phasing gyromagnetic nonlinear transmission lines
Implementing nonlinear transmission line (NLTL) technology in the design of a high power microwave source has the benefits of producing a comparatively small and lightweight solid-state system where the emission frequency is easily tuned. Usually, smaller in physical size, single NLTLs may produce significantly less power than its vacuum based counterparts. However, combining individual NLTL outputs electrically or in free-space is an attractive solution to achieve greater output power. This paper discusses a method for aligning a four element NLTL antenna array with coaxial geometry using easily adjustable temporal delay lines. These delay lines, sometimes referred to as pulse shock lines or pulse sharpening lines, are placed serially in front of the main NLTL line. The propagation velocity in each delay line is set by the voltage amplitude of an incident pulse as well as the magnetic field bias. Each is adjustable although for the system described in this paper, the voltage is held constant while the bias is changed through applying an external DC magnetic field of varying magnitude. Three different ferrimagnetic materials are placed in the temporal delay line to evaluate which yields the greatest range of electrical delay with the least amount of variability from consecutive shots.
- 1 March 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (3) , 034702
Optically isolated, 2 kHz repetition rate, 4 kV solid-state pulse trigger generator
This paper presents the design and operation characteristics of a solid-state high voltage pulse generator. Its primary utilization is aimed at triggering a gaseous spark gap with high repeatability. Specifically, the trigger generator is designed to achieve a risetime on the order of 0.1 kV/ns to trigger the first stage, trigatron spark gap of a 10-stage, 500 kV Marx generator. The major design components are comprised of a 60 W constant current DC-DC converter for high voltage charging, a single 4 kV thyristor, a step-up pulse transformer, and magnetic switch for pulse steepening. A risetime of <30 ns and pulse magnitude of 4 kV is achieved matching the simulated performance of the design.
- 1 March 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (3) , 034702
Optically isolated, 2 kHz repetition rate, 4 kV solid-state pulse trigger generator
This paper presents the design and operation characteristics of a solid-state high voltage pulse generator. Its primary utilization is aimed at triggering a gaseous spark gap with high repeatability. Specifically, the trigger generator is designed to achieve a risetime on the order of 0.1 kV/ns to trigger the first stage, trigatron spark gap of a 10-stage, 500 kV Marx generator. The major design components are comprised of a 60 W constant current DC-DC converter for high voltage charging, a single 4 kV thyristor, a step-up pulse transformer, and magnetic switch for pulse steepening. A risetime of <30 ns and pulse magnitude of 4 kV is achieved matching the simulated performance of the design.