Nirav Patel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nirav Patel has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Ajay Kumar
Punjab Engineering College
11 shared publications Nitin Gupta
Department of Electrical Engineering Malaviya National Institute of Technology Jaipur JLN Marg India
9 shared publications- Nitin Gupta
MNIT
7 shared publications - Ramesh C. Bansal
Department of Electrical Engineering, University Of Sharjah, Sharjah, United Arab Emirates
6 shared publications B. Chitti Babu
Department of Electronics and Communication Engineering Indian Institute of Information Technology, Design and Manufacturing Kancheepuram Chennai India
5 shared publications- Ali Ahmed Adam
Department of Electrical Engineering, University Of Sharjah, Sharjah, United Arab Emirates
3 shared publications
Latest Publications
- Open Access
- 22 October 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 162
Direct modulation in MMC-Based multiterminal hybrid Microgrid: A solution for arm capacitor voltage balancing under unbalanced power distribution
- 22 October 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 162
Open AccessDirect modulation in MMC-Based multiterminal hybrid Microgrid: A solution for arm capacitor voltage balancing under unbalanced power distribution
- 20 June 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 223
A novel proposal for harmonic compensation in the grid-connected photovoltaic system under electric anomalies
- 20 June 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 223
A novel proposal for harmonic compensation in the grid-connected photovoltaic system under electric anomalies
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 17 (2) , 2709-2720
Adaptive qXE-LMF Filter for Improving Power Quality Using Grid-Supporting Photovoltaic System
In practice, nonlinear electrical loads pose various power quality (PQ) challenges. Driven by these challenges, a parallel combination of a nonlinear load and a photovoltaic (PV) inverter with adaptive quantum normalized-least mean fourth ( q XE-LMF) filter is proposed and experimentally validated to detect and compensate for the harmonics in harmonically contaminated currents. A scheme with an adaptive q XE-LMF using fundamental weight components is used to generate the harmonics in the inverter output current thereby improving the PQ of the grid supply. The resulting grid current is pure and balanced; the PV inverter connected in parallel with the nonlinear load provides reactive and harmonic current support. Practically, the adaptive feature enables the online learning of filter weights of the load current harmonics to guarantee unconditionally balanced sinusoidal grid current. The proposed q XE-LMF filter ensures fast convergence and minimum steady-state oscillations in the grid reference currents. An improved anti-windup PI compensator is used to ensure dc-link voltage stabilization. The practicality of the proposed adaptive q XE-LMF filter is experimentally demonstrated using a three-phase four-wire uncontrolled rectifier-based nonlinear load. The experimental results also demonstrate the robustness of the q XE-LMF filter against changes in solar insolation level and nonlinear loads.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 17 (2) , 2709-2720
Adaptive qXE-LMF Filter for Improving Power Quality Using Grid-Supporting Photovoltaic System
In practice, nonlinear electrical loads pose various power quality (PQ) challenges. Driven by these challenges, a parallel combination of a nonlinear load and a photovoltaic (PV) inverter with adaptive quantum normalized-least mean fourth ( q XE-LMF) filter is proposed and experimentally validated to detect and compensate for the harmonics in harmonically contaminated currents. A scheme with an adaptive q XE-LMF using fundamental weight components is used to generate the harmonics in the inverter output current thereby improving the PQ of the grid supply. The resulting grid current is pure and balanced; the PV inverter connected in parallel with the nonlinear load provides reactive and harmonic current support. Practically, the adaptive feature enables the online learning of filter weights of the load current harmonics to guarantee unconditionally balanced sinusoidal grid current. The proposed q XE-LMF filter ensures fast convergence and minimum steady-state oscillations in the grid reference currents. An improved anti-windup PI compensator is used to ensure dc-link voltage stabilization. The practicality of the proposed adaptive q XE-LMF filter is experimentally demonstrated using a three-phase four-wire uncontrolled rectifier-based nonlinear load. The experimental results also demonstrate the robustness of the q XE-LMF filter against changes in solar insolation level and nonlinear loads.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (2) , 305-314
An Optimized Fractional Nonlinear Synergic Controller for Maximum Power Point Tracking of Photovoltaic Array Under Abrupt Irradiance Change
Maximum power point (MPP) tracking algorithms have always been at the forefront in photovoltaic (PV) systems to counter the nonlinearity caused by PV arrays and, thereby, harvest maximum power. There are several MPP trackers, including fixed and variable step size. The application of a fixed step-size MPP tracker leads to steady-state power oscillations around MPP. On the other hand, a conventional variable step-size MPP tracker employs a constant multiplying factor to increase the convergence rate; however, its response is found to be sluggish under PV parameters’ uncertainties. Therefore, in this article, an optimized fractional nonlinear synergetic controller (FNSC) driven MPP tracker is proposed to meticulously detect the true MPP. The proposed optimized FNSC provides a large dynamic range and ensures minimal sustained power oscillations around MPP even under unequal irradiances. The algorithm based on fractional calculus utilizes macrovariables for improving the performance of the proposed FNSC under steady-state and dynamic operating conditions. The effectiveness of the proposed optimized FNSC is verified using OPAL-RT (OP5700). The outcomes of this study validate the practicability of an FNSC-driven MPP tracker to guarantee less MPP tracking time. The MPP tracking time recorded with the proposed FNSC during steady-state and dynamic conditions is less than 21.80 and 20.80 ms , respectively. Besides, it guarantees 99.7% tracking efficiency and, thereby, outperforms the existing MPP trackers.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (2) , 305-314
An Optimized Fractional Nonlinear Synergic Controller for Maximum Power Point Tracking of Photovoltaic Array Under Abrupt Irradiance Change
Maximum power point (MPP) tracking algorithms have always been at the forefront in photovoltaic (PV) systems to counter the nonlinearity caused by PV arrays and, thereby, harvest maximum power. There are several MPP trackers, including fixed and variable step size. The application of a fixed step-size MPP tracker leads to steady-state power oscillations around MPP. On the other hand, a conventional variable step-size MPP tracker employs a constant multiplying factor to increase the convergence rate; however, its response is found to be sluggish under PV parameters’ uncertainties. Therefore, in this article, an optimized fractional nonlinear synergetic controller (FNSC) driven MPP tracker is proposed to meticulously detect the true MPP. The proposed optimized FNSC provides a large dynamic range and ensures minimal sustained power oscillations around MPP even under unequal irradiances. The algorithm based on fractional calculus utilizes macrovariables for improving the performance of the proposed FNSC under steady-state and dynamic operating conditions. The effectiveness of the proposed optimized FNSC is verified using OPAL-RT (OP5700). The outcomes of this study validate the practicability of an FNSC-driven MPP tracker to guarantee less MPP tracking time. The MPP tracking time recorded with the proposed FNSC during steady-state and dynamic conditions is less than 21.80 and 20.80 ms , respectively. Besides, it guarantees 99.7% tracking efficiency and, thereby, outperforms the existing MPP trackers.
- 18 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2274-2289
Multimode Control for Power Quality Improvement in an Electronically Coupled Distributed Generation Unit Under Grid Connected and Autonomous Modes
This paper develops a new multimode control strategy for power quality (PQ) improvement in distributed generation (DG) units that employs a voltage source converter (VSC) as the electronic interface medium. The devised control strategy seamlessly operates for both the grid connected (GC) and autonomous/stand-alone (SA) modes of microgrid (MG). A novel computationally efficient comb-filter driven discrete time oscillator is developed for current reference generation (CRG) under GC operation. It constitutes a cluster of zeros to introduce notch peaks at integer multiples of the fundamental frequency thereby ensuring improved harmonic rejection capability. Consequently, it ensures unconditionally balanced and sinusoidal grid currents with improved PQ to comply with grid interconnection codes prescribed in the IEEE std-519 and std-1547 even under electrical anomalies. In the SA mode, the CRG scheme is developed in a stationary reference frame with an improved vector proportional integral (VPI) compensator. Despite the uncertainty of load parameters, the proposed VPI guarantees zero steady-state error and superior transient response. A finite state machine-based synchronization framework is proposed to ensure secure and seamless transfer of MG between GC and SA even under disturbances. The practical viability of the proposed multimode control has been demonstrated by applying various switching rules in both GC and SA modes of MG operation.
- 18 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2274-2289
Multimode Control for Power Quality Improvement in an Electronically Coupled Distributed Generation Unit Under Grid Connected and Autonomous Modes
This paper develops a new multimode control strategy for power quality (PQ) improvement in distributed generation (DG) units that employs a voltage source converter (VSC) as the electronic interface medium. The devised control strategy seamlessly operates for both the grid connected (GC) and autonomous/stand-alone (SA) modes of microgrid (MG). A novel computationally efficient comb-filter driven discrete time oscillator is developed for current reference generation (CRG) under GC operation. It constitutes a cluster of zeros to introduce notch peaks at integer multiples of the fundamental frequency thereby ensuring improved harmonic rejection capability. Consequently, it ensures unconditionally balanced and sinusoidal grid currents with improved PQ to comply with grid interconnection codes prescribed in the IEEE std-519 and std-1547 even under electrical anomalies. In the SA mode, the CRG scheme is developed in a stationary reference frame with an improved vector proportional integral (VPI) compensator. Despite the uncertainty of load parameters, the proposed VPI guarantees zero steady-state error and superior transient response. A finite state machine-based synchronization framework is proposed to ensure secure and seamless transfer of MG between GC and SA even under disturbances. The practical viability of the proposed multimode control has been demonstrated by applying various switching rules in both GC and SA modes of MG operation.
- 26 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (4) , 5328-5339
L2 Norm Enabled Adaptive LMS Control for Grid-Connected Photovoltaic Converters
This study presents a L2 norm-enabled variable step-size adaptive least mean square (LMS) controller for grid-connected photovoltaic (PV) converter. The variable step-size is adopted to damp out the weight oscillations and to enable faster convergence under exposure to disturbances in the load and solar insolation. More precisely, to achieve oscillations free response, a non-linear relationship is developed between step-size and estimated error. This way, it significantly improves the convergence speed and stability. The iteration function of presented variable step-size feature includes the input signal to study the impact of harmonically polluted load current on the weight extraction performance. Besides, the designing procedure of step-size considers both current and previous error states, thereby ensuring noise immunity. With inclusion of these features, the devised controller is applied to accurately extracting the fundamental weight component of the load current and in turn enabling various ancillary services. The proposed control algorithm is designed in MATLAB/Simulink software and its effectiveness is examined under both steady-state and transient conditions during grid disturbances. Further, the practicability of proposed controller is verified and compared with conventional controls using ARM cortex M4 microcontroller-based laboratory testbed. In a nutshell, the results confirm the oscillations free weight component with higher convergence and better stability under various operating conditions.
- 26 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (4) , 5328-5339
L2 Norm Enabled Adaptive LMS Control for Grid-Connected Photovoltaic Converters
This study presents a L2 norm-enabled variable step-size adaptive least mean square (LMS) controller for grid-connected photovoltaic (PV) converter. The variable step-size is adopted to damp out the weight oscillations and to enable faster convergence under exposure to disturbances in the load and solar insolation. More precisely, to achieve oscillations free response, a non-linear relationship is developed between step-size and estimated error. This way, it significantly improves the convergence speed and stability. The iteration function of presented variable step-size feature includes the input signal to study the impact of harmonically polluted load current on the weight extraction performance. Besides, the designing procedure of step-size considers both current and previous error states, thereby ensuring noise immunity. With inclusion of these features, the devised controller is applied to accurately extracting the fundamental weight component of the load current and in turn enabling various ancillary services. The proposed control algorithm is designed in MATLAB/Simulink software and its effectiveness is examined under both steady-state and transient conditions during grid disturbances. Further, the practicability of proposed controller is verified and compared with conventional controls using ARM cortex M4 microcontroller-based laboratory testbed. In a nutshell, the results confirm the oscillations free weight component with higher convergence and better stability under various operating conditions.
- Open Access
- 1 November 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (14) , 3044-3055
Performance enhancement of photovoltaic system under grid voltage distortion utilising total least‐square control scheme
Grid‐interfaced solar photovoltaic (GIPV) system requires a robust control algorithm for satisfactory operation under grid voltage disturbances. In this study, an application of Newton's learning rule‐based total least‐square estimation employing single‐layer neural network structure is adopted to interface the photovoltaic unit with the utility grid. In addition, the weight‐updating mechanism is uniquely integrated with threshold neuron for attaining speedy extraction of fundamental load current component. In particular, the proposed control algorithm has the capability to transfer maximum active power to the utility grid/AC load at unity power factor while operating as distribution static compensator to offer various ancillary services including current harmonics attenuation and reactive current suppression. This will lead to increased device utilisation factor of the overall GIPV system during night time (i.e. in the absence of solar irradiance). Moreover, the proposed control scheme is designed and developed without any complex transformations and derivative terms, which results in less computational intensiveness. The GIPV system with three‐phase double‐stage configuration is modelled in MATLAB/Simulink software using sim‐power system tool. Finally, the adaptability of the proposed control algorithm has been verified and confirmed through 500 W laboratory prototype using low‐cost Arm Cortex‐M4 microcontroller under various operating conditions.
- 1 November 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (14) , 3044-3055
Open AccessPerformance enhancement of photovoltaic system under grid voltage distortion utilising total least‐square control scheme
Grid‐interfaced solar photovoltaic (GIPV) system requires a robust control algorithm for satisfactory operation under grid voltage disturbances. In this study, an application of Newton's learning rule‐based total least‐square estimation employing single‐layer neural network structure is adopted to interface the photovoltaic unit with the utility grid. In addition, the weight‐updating mechanism is uniquely integrated with threshold neuron for attaining speedy extraction of fundamental load current component. In particular, the proposed control algorithm has the capability to transfer maximum active power to the utility grid/AC load at unity power factor while operating as distribution static compensator to offer various ancillary services including current harmonics attenuation and reactive current suppression. This will lead to increased device utilisation factor of the overall GIPV system during night time (i.e. in the absence of solar irradiance). Moreover, the proposed control scheme is designed and developed without any complex transformations and derivative terms, which results in less computational intensiveness. The GIPV system with three‐phase double‐stage configuration is modelled in MATLAB/Simulink software using sim‐power system tool. Finally, the adaptability of the proposed control algorithm has been verified and confirmed through 500 W laboratory prototype using low‐cost Arm Cortex‐M4 microcontroller under various operating conditions.
- Open Access
- 1 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (13) , 2905-2916
Pseudo affine projection assisted multitasking approach for power quality improvement in grid‐interactive photovoltaic (PV) system
The electronically interfaced photovoltaic (PV) system and its control approach form an intrinsic part of the distributed generation (DG) system. This study proposes pseudo affine projection (PAP)‐assisted multitasking control scheme for grid‐integrated DG inverter under input grid voltage disturbances. The PAP approach is based on the convergence of active weighted values and is independent of the input signal property, which manifests a discrete characteristic. Additionally, it exhibits a unique capability of updating weight based on multiple, delayed input signal vectors. The fundamental distinguishing feature of the proposed PAP is its intrinsic learning behaviour and therefore it provides an optimal solution to the ingrained paradox between steady‐state misadjustment and convergence speed compared to its conventional counterpart affine projection. The PAP‐assisted algorithm practically enables DG inverter to perform multiple tasks including suppression of source current harmonics, unbalancing, and neutral current. It also provides load reactive current support with unity power factor operation while transferring the maximum active power into the utility grid. The practicality of the proposed PAP algorithm is investigated through MATLAB/Simulink software. Finally, the experimental results recorded with the dSPACE‐1104 based real‐time control platform show good to excellent agreement with simulations in the steady‐state, as well as transient phenomena.
- 1 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (13) , 2905-2916
Open AccessPseudo affine projection assisted multitasking approach for power quality improvement in grid‐interactive photovoltaic (PV) system
The electronically interfaced photovoltaic (PV) system and its control approach form an intrinsic part of the distributed generation (DG) system. This study proposes pseudo affine projection (PAP)‐assisted multitasking control scheme for grid‐integrated DG inverter under input grid voltage disturbances. The PAP approach is based on the convergence of active weighted values and is independent of the input signal property, which manifests a discrete characteristic. Additionally, it exhibits a unique capability of updating weight based on multiple, delayed input signal vectors. The fundamental distinguishing feature of the proposed PAP is its intrinsic learning behaviour and therefore it provides an optimal solution to the ingrained paradox between steady‐state misadjustment and convergence speed compared to its conventional counterpart affine projection. The PAP‐assisted algorithm practically enables DG inverter to perform multiple tasks including suppression of source current harmonics, unbalancing, and neutral current. It also provides load reactive current support with unity power factor operation while transferring the maximum active power into the utility grid. The practicality of the proposed PAP algorithm is investigated through MATLAB/Simulink software. Finally, the experimental results recorded with the dSPACE‐1104 based real‐time control platform show good to excellent agreement with simulations in the steady‐state, as well as transient phenomena.
- 23 September 2020
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (12)
Electronically coupled photovoltaic system with grey wolf optimizer enabled DC ‐link voltage control loop
- 23 September 2020
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (12)
Electronically coupled photovoltaic system with grey wolf optimizer enabled DC ‐link voltage control loop