OBOliver Burgert

Oliver Burgert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Oliver Burgert has a total of 285 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing Surgical Workflows through DICOM

    by Isabel Härtl, Denise Junger, Patrick Beyersdorffer, Oliver Burgert, Christian Kücherer

    The Digital Imaging and Communications in Medicine (DICOM) standard has evolved from a radiological data exchange protocol into a foundational element for surgical informatics. DICOM Working Group 24 - “Surgery” aims to facilitate intra-operative usage of the DICOM standard to optimize surgical procedures. This paper presents a structured overview of DICOM-based use cases in surgery, spanning preoperative planning, intraoperative guidance, and postoperative documentation. Based on a comprehensive user story schema, we categorize and analyze over 20 real-world scenarios that demonstrate how DICOM services-such as segmentation (DICOM-SEG), structured reporting (DICOMSR), and Unified Procedure Steps (UPS)-enable interoperability, precision, and automation in surgical environments. We highlight the benefits of standardized data exchange for surgical planning, intraoperative decision support, and quality assurance, while also addressing integration with clinical information systems and data protection. The findings underscore DICOM’s potential to serve as a unifying framework for data-driven, context-aware surgical workflows.

  • Open Access

    Surgical workflow analysis for Surgomics and context-aware assistance in robot-assisted minimally invasive esophagectomy (RAMIE): a retrospective, single-arm, multicenter annotation and machine learning study

    by Johanna M. Brandenburg, André Schulze, Alexander C. Jenke, Nithya Bhasker, Noelle Bleser, Denise Junger, Antonia Stern, Dominik Rivoir, Hamid Naderi, Fleur Fritz-Kebede, et al.


  • Open Access

    Transferable situation recognition system for scenario-independent context-aware surgical assistance systems: a proof of concept

    by D. Junger, C. Kücherer, B. Hirt, O. Burgert

    Purpose: Surgical interventions and the intraoperative environment can vary greatly. A system that reliably recognizes the situation in the operating room should therefore be flexibly applicable to different surgical settings. To achieve this, transferability should be focused during system design and development. In this paper, we demonstrated the feasibility of a transferable, scenario-independent situation recognition system (SRS) by the definition and evaluation based on non-functional requirements. Methods: Based on a high-level concept for a transferable SRS, a proof of concept implementation was demonstrated using scenarios. The architecture was evaluated with a focus on non-functional requirements of compatibility, maintainability, and portability. Moreover, transferability aspects beyond the requirements, such as the effort to cover new scenarios, were discussed in a subsequent argumentative evaluation. Results: The evaluation demonstrated the development of an SRS that can be applied to various scenarios. Furthermore, the investigation of the transferability to other settings highlighted the system’s characteristics regarding configurability, interchangeability, and expandability. The components can be optimized step by step to realize a versatile and efficient situation recognition that can be easily adapted to different scenarios. Conclusion: The prototype provides a framework for scenario-independent situation recognition, suggesting greater applicability and transferability to different surgical settings. For the transfer into clinical routine, the system’s modules need to be evolved, further transferability challenges be addressed, and comprehensive scenarios be integrated.

  • Open Access

    Speech Recognition for the Sterile Interaction with Information Systems in the Surgical Area

    by Katrin V. Schrüfer, Pascal Noortwijck, Denise Junger, Oliver Burgert

    This paper describes how automatic speech recognition (ASR) can be used to explore electronic patient records (EPR) in a sterile environment. As an information display, we used a system that was developed for the presentation of patient data and for supporting surgical hand disinfection. The speech recognition was performed using the Mozilla Web Speech API. A room microphone, a Jabra Box, and a directional microphone, a RØDE NT-USB Mini, were tested at various positions. Interactions with the EPR are triggered with a list of commands. The interaction was working as indented and test persons reported the system as intuitive.


  • Open Access

    Towards examiner-independent reproducible abdominal ultrasound examinations

    by Tobias Baader, Thanh Nam Bach, Sümeyra Yavuz, Lukas Klaus Brand, Beyda Güler, Peter Grupp, Nisar Peter Malek, Tatjana Hoffmann, Jan Pauluschke-Fröhlich, Eckhart Fröhlich, et al.

    The proposed system aims at reproducibility in ultrasound follow-up examinations by storing the position of the ultrasound transducer in relation to acquired images. The system utilizes an electromagnetic tracking system. It includes a guidance feature to assist in placing the transducer correctly on the patient. Evaluation of the system involved technical accuracy tests on a phantom and accuracy tests on human subjects. The results showed that the technical accuracy of the system met the required criteria, but the transducer positioning error in realistic scenarios was above the threshold. Usability testing indicated potential benefits for medical training and provided suggestions for improving the user interface. Overall, the system shows promise for further development and can already be used for training ultrasound examinations.

  • Open Access

    Univie: An App for Managing Digital Health Data of Refugees

    by Ahmad Salah, Salah Alobid, Sahel Jalalzai, Denise Junger, Oliver Burgert

    The refugee crisis has reached historic proportions, with more than 82 million people on the run. Access to healthcare is often difficult for them due to a lack of medical records and language barriers. This paper examines a digital medical documentation system for refugees that captures, stores, and translates records. International data protection standards are considered. The contribution consists of designing a system that manages and translates medical data across borders and integrates a prediction model for epidemics in refugee camps.


  • Open Access

    Toward an interoperable, intraoperative situation recognition system via process modeling, execution, and control using the standards BPMN and CMMN

    by Denise Junger, Elisaveta Just, Johanna M. Brandenburg, Martin Wagner, Katharina Schaumann, Thomas Klenzner, Oliver Burgert

    Purpose: For the modeling, execution, and control of complex, non-standardized intraoperative processes, a modeling language is needed that reflects the variability of interventions. As the established Business Process Model and Notation (BPMN) reaches its limits in terms of flexibility, the Case Management Model and Notation (CMMN) was considered as it addresses weakly structured processes. Methods: To analyze the suitability of the modeling languages, BPMN and CMMN models of a Robot-Assisted Minimally Invasive Esophagectomy and Cochlea Implantation were derived and integrated into a situation recognition workflow. Test cases were used to contrast the differences and compare the advantages and disadvantages of the models concerning modeling, execution, and control. Furthermore, the impact on transferability was investigated. Results: Compared to BPMN, CMMN allows flexibility for modeling intraoperative processes while remaining understandable. Although more effort and process knowledge are needed for execution and control within a situation recognition system, CMMN enables better transferability of the models and therefore the system. Concluding, CMMN should be chosen as a supplement to BPMN for flexible process parts that can only be covered insufficiently by BPMN, or otherwise as a replacement for the entire process. Conclusion: CMMN offers the flexibility for variable, weakly structured process parts, and is thus suitable for surgical interventions. A combination of both notations could allow optimal use of their advantages and support the transferability of the situation recognition system.


  • Open Access

    A Toolchain for Big Data Analyses in the Intelligent Cognitive Operating Room

    by Elena Kirsch, Denise Junger, Christian Kücherer, Oliver Burgert

    This project aims to evaluate existing big data infrastructures for their applicability in the operating room to support medical staff with context-sensitive systems. Requirements for the system design were generated. The project compares different data mining technologies, interfaces, and software system infrastructures with a focus on their usefulness in the peri-operative setting. The lambda architecture was chosen for the proposed system design, which will provide data for both postoperative analysis and real-time support during surgery.

  • Open Access

    A high-fidelity prototype of a sterile information system for the perioperative area: OR-Pad

    by C. Ryniak, S. M. Frommer, D. Junger, S. Lohmann, M. Stadelmaier, P. Schmutz, A. Stenzl, B. Hirt, O. Burgert

    Purpose: Supporting the surgeon during surgery is one of the main goals of intelligent ORs. The OR-Pad project aims to optimize the information flow within the perioperative area. A shared information space should enable appropriate preparation and provision of relevant information at any time before, during, and after surgery. Methods: Based on previous work on an interaction concept and system architecture for the sterile OR-Pad system, we designed a user interface for mobile and intraoperative (stationary) use, focusing on the most important functionalities like clear information provision to reduce information overload. The concepts were transferred into a high-fidelity prototype for demonstration purposes. The prototype was evaluated from different perspectives, including a usability study. Results: The prototype’s central element is a timeline displaying all available case information chronologically, like radiological images, labor findings, or notes. This information space can be adapted for individual purposes (e.g., highlighting a tumor, filtering for own material). With the mobile and intraoperative mode of the system, relevant information can be added, preselected, viewed, and extended during the perioperative process. Overall, the evaluation showed good results and confirmed the vision of the information system. Conclusion: The high-fidelity prototype of the information system OR-Pad focuses on supporting the surgeon via a timeline making all available case information accessible before, during, and after surgery. The information space can be personalized to enable targeted support. Further development is reasonable to optimize the approach and address missing or insufficient aspects, like the holding arm and sterility concept or new desired features.


  • Entwicklung und Evaluation eines Simulators für die endoskopische Nasennebenhöhlenoperation

    by Antje Pößneck, Alexandra Annemarie Ludwig, Oliver Burgert, Edgar Nowatius, Heiko Maass, Hüseyin Kemal Çakmak, Andreas Dietz

    Hintergrund Endoskopische Operationsverfahren haben sich als Goldstandard in der Nasennebenhöhlen (NNH)-Chirurgie etabliert. Den sich daraus ergebenden Herausforderungen für die chirurgische Ausbildung kann durch den Einsatz von Virtuelle-Realität (VR)-Trainingssimulatoren begegnet werden. Bislang wurde eine Reihe von Simulatoren für NNH-Operationen entwickelt. Frühere Studien im Hinblick auf den Trainingseffekt wurden jedoch nur mit medizinisch vorgebildeten Probanden durchgeführt oder es wurde nicht über dessen zeitlichen Verlauf berichtet. Methoden Ein NNH-CT-Datensatz wurde nach der Segmentierung in ein 3-dimensionales, polygonales Oberflächenmodell überführt und mithilfe von originalem Fotomaterial texturiert. Die Interaktion mit der virtuellen Umgebung erfolgte über ein haptisches Eingabegerät. Während der Simulation wurden die Parameter Eingriffsdauer und Fehleranzahl erfasst. Zehn Probanden absolvierten jeweils eine Trainingseinheit bestehend aus je 5 Übungsdurchläufen an 10 aufeinanderfolgenden Tagen. Ergebnisse Vier Probanden verringerten die benötigte Zeit um mehr als 60% im Verlauf des Übungszeitraums. Vier der Probanden verringerten ihre Fehleranzahl um mehr als 60%. Acht von 10 Probanden zeigten eine Verbesserung bezüglich beider Parameter. Im Median wurde im gesamten gemessenen Zeitraum die Dauer des Eingriffs um 46 Sekunden und die Fehleranzahl um 191 reduziert. Die Überprüfung eines Zusammenhangs zwischen den 2 Parametern ergab eine positive Korrelation. Schlussfolgerung Zusammenfassend lässt sich feststellen, dass das Training am NNH-Simulator auch bei unerfahrenen Personen die Performance beträchtlich verbessert, sowohl in Bezug auf die Dauer als auch auf die Genauigkeit des Eingriffs. Background Endoscopic surgical procedures have been established as gold standard in sinus surgery. Challenges for surgical training have been addressed by the use of virtual reality (VR) simulators. To date, a number of simulators have been developed. However, previous studies regarding their training effects investigated only medically pretrained subjects or the time course of training outcomes has not been reported. Methods A computer tomography (CT) dataset was segmented manually. A three-dimensional polygonal surface model was generated and textured using original photographic material. Interaction with the virtual environment was performed using a haptic input device. For the investigation of training outcomes with the simulator, the parameters duration and the number of errors were recorded. Ten subjects completed a training consisting of five runs on ten consecutive days. Results Within the whole exercise period, four subjects reduced the duration of intervention by more than 60%. Four subjects reduced the number of errors by more than 60%. Eight out of 10 subjects showed an improvement with respect to both parameters. On median, the duration of the procedure was reduced by 46 seconds and the number of errors by 191. The statistical analysis between the two parameters showed a positive correlation. Conclusion Our data suggests that training on the FESS-simulator considerably improves the performance even in inexperienced subjects, both in terms of duration and accuracy of the procedure. Received: 29 October 2021 Accepted after revision: 29 April 2022 Article published online: 20 June 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany