IKInsu Kim

Insu Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Insu Kim has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Caco-2 cell-derived biomimetic electrochemical biosensor for cholera toxin detection

    by Yonghwan Kim, Dongtak Lee, Youngjun Seo, Hyo Gi Jung, Jae Won Jang, Dongsung Park, Insu Kim, Jaeheung Kim, Gyudo Lee, Kyo Seon Hwang, et al.


  • Surface Functionalization of Enzyme-Coronated Gold Nanoparticles with an Erythrocyte Membrane for Highly Selective Glucose Assays

    by Jae Won Jang, Hyunji Kim, Insu Kim, Sang Won Lee, Hyo Gi Jung, Kyo Seon Hwang, Jeong Hoon Lee, Gyudo Lee, Dongtak Lee, Dae Sung Yoon

    Colorimetric glucose sensors using enzyme-coronated gold nanoparticles have been developed for high-throughput assays to monitor the blood glucose levels of diabetic patients. Although those sensors have shown sensitivity and wide linear detection ranges, they suffer from poor selectivity and stability in detecting blood glucose, which has limited their practical use. To address this limitation, herein, we functionalized glucose-oxidase-coronated gold nanoparticles with an erythrocyte membrane (EM-GOx-GNPs). Because the erythrocyte membrane (EM) selectively facilitates the permeation of glucose via glucose transporter-1 (GLUT1), the functionalization of GOx-GNPs with EM improved the stability, selectivity (3.3- to 15.8-fold higher), and limit of detection (LOD). Both membrane proteins, GLUT1 and aquaporin-1 (AQP1), on EM were shown to be key components for selective glucose detection by treatment with their inhibitors. Moreover, we demonstrated the stability of EM-GOx-GNPs in high-antioxidant-concentration conditions, under long-term storage (∼4 weeks) and a freeze-thaw cycle. Selectivity of the EM-GOx-GNPs against other saccharides was increased, which improved the LOD in phosphate-buffered saline and human serum. Our results indicated that the functionalization of colorimetric glucose sensors with EM is beneficial for improving selectivity and stability, which may make them candidates for use in a practical glucose sensor.


  • Lab-on-a-Disc for Point-of-Care Infection Diagnostics

    by Vijaya Sunkara, Sumit Kumar, Jonathan Sabaté del Río, Insu Kim, Yoon-Kyoung Cho

    Reliable, inexpensive, and rapid diagnostic tools are essential to control and prevent the spread of infectious diseases. Many commercial kits for coronavirus disease 2019 (COVID-19) diagnostics have played a crucial role in the fight against the COVID-19 pandemic. Most current standard in vitro diagnostic (IVD) protocols for infectious diseases are sensitive but time-consuming and require sophisticated laboratory equipment and specially trained personnel. Recent advances in biosensor technology suggest the potential to deliver point-of-care (POC) diagnostics that are affordable and provide accurate results in a short time. The ideal “sample-in–answer-out” type fully integrated POC infection diagnostic platforms are expected to be autonomous or easy-to-operate, equipment-free or infrastructure-independent, and high-throughput or easy to upscale. In this Account, we detail the recent progress made by our group and others in the development of centrifugal microfluidic devices or lab-on-a-disc (LOAD) systems. Unlike conventional pump-based fluid actuation, the centrifugal force generated by spinning the disc induces liquid pumping and no external fluidic interconnects are required. This allows a total fluidic network required for multiple steps of biological assays to be integrated on a disc, enabling fully automated POC diagnostics. Various applications have been demonstrated, including liquid biopsy for personalized cancer management, food applications, and environmental monitoring; here, we focus on IVD for infectious disease. First, we introduce various on-disc unit operation technologies, including reagent storage, sedimentation, filtration, valving, decanting, aliquoting, mixing, separation, serial dilution, washing, and calibration. Such centrifugal microfluidic technologies have already proved promising for micro-total-analysis systems for automated IVD ranging from molecular detection of pathogens to multiplexed enzyme-linked immunosorbent assays (ELISAs) that use raw samples such as whole blood or saliva. Some recent examples of LOAD systems for molecular diagnostics in which some or all steps of the assays are integrated on a disc, including pathogen enrichment, nucleic acid extraction, amplification, and detection, are discussed in detail. We then introduce fully automated ELISA systems with enhanced sensitivity. Furthermore, we demonstrate a toy-inspired fidget spinner that enables electricity-free and rapid analysis of pathogens from undiluted urine samples of patients with urinary tract infection symptoms and a phenotypic antimicrobial susceptibility test for an extreme POC diagnostics application. Considering the urgent need for cost-effective and reliable POC infection diagnostic tools, especially in the current pandemic crisis, the current limitations and future directions of fast and broad adaptation in real-world settings are also discussed. With proper attention to key challenges and leverage with recent advances in biosensing technologies, molecular biology, nanomaterials, analytical chemistry, miniaturization, system integration, and data management, LOAD systems hold the potential to deliver POC infection diagnostic tools with unprecedented performance regarding time, accuracy, and cost. We hope the new insight and promise of LOAD systems for POC infection diagnostics presented in this Account can spark new ideas and inspire further research and development to create better healthcare systems for current and future pandemics.


  • Erythrocyte-camouflaged biosensor for α-hemolysin detection

    by Insu Kim, Yonghwan Kim, Sang Won Lee, Dongtak Lee, Hyo Gi Jung, Jae Won Jang, Taeha Lee, Young Kyung Yoon, Gyudo Lee, Dae Sung Yoon


  • Coagulation-Inspired Direct Fibrinogen Assay Using Plasmonic Nanoparticles Functionalized with Red Blood Cell Membranes

    by Insu Kim, Dongtak Lee, Sang Won Lee, Jeong Hoon Lee, Gyudo Lee, Dae Sung Yoon

    The fast measurement of fibrinogen is essential in evaluating life-threatening sepsis and cardiovascular diseases. Here, we aim to utilize biomimetic plasmonic Au nanoparticles using red blood cell membranes (RBCM-AuNPs) and demonstrate nanoscale coagulation-inspired fibrinogen detection via cross-linking between RBCM-AuNPs. The proposed biomimetic RBCM-AuNPs are highly suitable for fibrinogen detection because hemagglutination, occurring in the presence of fibrinogen, induces a shift in the localized surface plasmon resonance of the NPs. Specifically, when the two ends of the fibrinogen protein are bound to receptors on separate RBCM-AuNPs, cross-linking of the RBCM-AuNPs occurs, yielding a corresponding plasmon shift within 10 min. This coagulation-inspired fibrinogen detection method, with a low sample volume, high selectivity, and high speed, could facilitate the diagnosis of sepsis and cardiovascular diseases.


  • Open Access

    Plasmonic nanoparticle amyloid corona for screening Aβ oligomeric aggregate-degrading drugs

    by Dongtak Lee, Dongsung Park, Insu Kim, Sang Won Lee, Wonseok Lee, Kyo Seon Hwang, Jeong Hoon Lee, Gyudo Lee, Dae Sung Yoon

    The generation of toxic amyloid β (Aβ) oligomers is a central feature of the onset and progression of Alzheimer’s disease (AD). Drug discoveries for Aβ oligomer degradation have been hampered by the difficulty of Aβ oligomer purification and a lack of screening tools. Here, we report a plasmonic nanoparticle amyloid corona (PNAC) for quantifying the efficacy of Aβ oligomeric aggregate-degrading drugs. Our strategy is to monitor the drug-induced degradation of oligomeric aggregates by analyzing the colorimetric responses of PNACs. To test our strategy, we use Aβ-degrading proteases (protease XIV and MMP-9) and subsequently various small-molecule substances that have shown benefits in the treatment of AD. We demonstrate that this strategy with PNAC can identify effective drugs for eliminating oligomeric aggregates. Thus, this approach presents an appealing opportunity to reduce attrition problems in drug discovery for AD treatment.


  • Bio-Inspired Electronic Textile Yarn-Based NO2 Sensor Using Amyloid–Graphene Composite

    by Sang Won Lee, Wonseok Lee, Insu Kim, Dongtak Lee, Dongsung Park, Woong Kim, Jinsung Park, Jeong Hoon Lee, Gyudo Lee, Dae Sung Yoon

    Graphene-based e-textile gas sensors have received significant attention as wearable electronic devices for human healthcare and environmental monitoring. Theoretically, more the attached graphene on the devices, better is the gas-sensing performance. However, it has been hampered by poor adhesion between graphene and textile platforms. Meanwhile, amyloid nanofibrils are reputed for their ability to improve adhesion between materials, including between graphene and microorganisms. Despite that fact, there has been no attempt to apply amyloid nanofibrils to fabricate graphene-based e-textiles. By biomimicking the adhesion ability of amyloid nanofibrils, herein, we developed a graphene–amyloid nanofibril hybrid e-textile yarn (RGO/amyloid nanofibril/CY) for the detection of NO2. Compared to traditional e-textile yarn, the RGO/amyloid nanofibril/CY showed better performance in response time, sensing efficiency, sensitivity, and selectivity for NO2. Last, we suggested a practical use of RGO/amyloid nanofibril/CY combined with a light-emitting diode as a wearable e-textile gas sensor.


  • Highly Conductive and Flexible Dopamine–Graphene Hybrid Electronic Textile Yarn for Sensitive and Selective NO2 Detection

    by Sang Won Lee, Hyo Gi Jung, Insu Kim, Dongtak Lee, Woong Kim, Sang Hun Kim, Jong-Heun Lee, Jinsung Park, Jeong Hoon Lee, Gyudo Lee, et al.

    Graphene-based electronic textile (e-textile) gas sensors have been developed for detecting hazardous NO2 gas. For the e-textile gas sensor, electrical conductivity is a critical factor because it directly affects its sensitivity. To obtain a highly conductive e-textile, biomolecules have used to gluing the graphene to the textile surface, though there remain areas to improve, such as poor conductivity and flexibility. Herein, we have developed a dopamine-graphene hybrid electronic textile yarn (DGY) where the dopamine is used as a bio-inspired adhesive to attach graphene to the surface of yarns. The DGY shows improved electrical conductivity (~40 times) compared to conventional graphene-based e-textile yarns with no glue. Moreover, it exhibited improved sensing performance in terms of short response time (~2 min), high sensitivity (0.02 μA/ppm), and selectivity toward NO2. The mechanical flexibility and durability of the DGY was examined through a 1,000-cycle bending test. For a practical application, the DGY was attempted to detect the NOx emitted from vehicles, including gasoline, diesel, and fuel cell electric vehicles. Our results demonstrated that the DGYs—as a graphene-based e-textile gas sensor for detecting NO2—are simple to fabricate, cheap, disposable, and mechanically stable.