Ph. Marmillod
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ph. Marmillod has a total of 483 co-authors. Here are the top co-authors by number of shared publications:
R Chavan
Centro de Fus|Nuclear Fusion Institute|RRC Kurchatov Institute
12 shared publicationsA Perez
Centro de Fus|Nuclear Fusion Institute|RRC Kurchatov Institute
11 shared publicationsD Fasel
Centro de Fus|Nuclear Fusion Institute|RRC Kurchatov Institute
11 shared publicationsH Weisen
11 shared publications- Ivo Furno
École Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC) , CH-1015 Lausanne
11 shared publications J B Lister
Centro de Fus|Nuclear Fusion Institute|RRC Kurchatov Institute
11 shared publications
Latest Publications
- Open Access
- 1 August 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (8) , 083502
Langmuir probe electronics upgrade on the tokamak à configuration variable
A detailed description of the Langmuir probe electronics upgrade for TCV (Tokamak à Configuration Variable) is presented. The number of amplifiers and corresponding electronics has been increased from 48 to 120 in order to simultaneously connect all of the 114 Langmuir probes currently mounted in the TCV divertor and main-wall tiles. Another set of 108 amplifiers is ready to be installed in order to connect 80 new probes, built in the frame of the TCV divertor upgrade. Technical details of the amplifier circuitry are discussed as well as improvements over the first generation of amplifiers developed at SPC (formerly CRPP) in 1993/1994 and over the second generation developed in 2012/2013. While the new amplifiers have been operated successfully for over a year, it was found that their silicon power transistors can be damaged during some off-normal plasma events. Possible solutions are discussed.
- 1 August 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (8) , 083502
Open AccessLangmuir probe electronics upgrade on the tokamak à configuration variable
A detailed description of the Langmuir probe electronics upgrade for TCV (Tokamak à Configuration Variable) is presented. The number of amplifiers and corresponding electronics has been increased from 48 to 120 in order to simultaneously connect all of the 114 Langmuir probes currently mounted in the TCV divertor and main-wall tiles. Another set of 108 amplifiers is ready to be installed in order to connect 80 new probes, built in the frame of the TCV divertor upgrade. Technical details of the amplifier circuitry are discussed as well as improvements over the first generation of amplifiers developed at SPC (formerly CRPP) in 1993/1994 and over the second generation developed in 2012/2013. While the new amplifiers have been operated successfully for over a year, it was found that their silicon power transistors can be damaged during some off-normal plasma events. Possible solutions are discussed.
- 1 December 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (12) , C12005
Improving spatial and spectral resolution of TCV Thomson scattering
- 1 December 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (12) , C12005
Improving spatial and spectral resolution of TCV Thomson scattering
- 1 November 2017
- Published by Elsevier in Fusion Engineering and Design
- Vol. 123, 331-335
Commissioning of the heating neutral beam injector on the TCV tokamak
- 1 November 2017
- Published by Elsevier in Fusion Engineering and Design
- Vol. 123, 331-335
Commissioning of the heating neutral beam injector on the TCV tokamak
- 1 November 2017
- Published by Elsevier in Fusion Engineering and Design
- Vol. 123, 468-472
Neutral beam heating on the TCV tokamak
- 1 November 2017
- Published by Elsevier in Fusion Engineering and Design
- Vol. 123, 468-472
Neutral beam heating on the TCV tokamak
- Open Access
- 24 July 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 147, 02005
Electron Cyclotron Emission (ECE) and Correlation ECE diagnostics on TCV
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 24 July 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 147, 02005
Open AccessElectron Cyclotron Emission (ECE) and Correlation ECE diagnostics on TCV
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- Open Access
- 1 March 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (3) , 035115
High sensitivity field asymmetric ion mobility spectrometer
A high sensitivity field asymmetric ion mobility spectrometer (FAIMS) was designed, fabricated, and tested. The main components of the system are a 10.6 eV UV photoionization source, an ion filter driven by a high voltage/high frequency n-MOS inverter circuit, and a low noise ion detector. The ion filter electronics are capable to generate square waveforms with peak-to-peak voltages up to 1000 V at frequencies up to 1 MHz with adjustable duty cycles. The ion detector current amplifier has a gain up to 1012 V/A with an effective equivalent input noise level down to about 1 fA/Hz1/2 during operation with the ion filter at the maximum voltage and frequency. The FAIMS system was characterized by detecting different standard chemical compounds. Additionally, we investigated the use of a synchronous modulation/demodulation technique to improve the signal-to-noise ratio in FAIMS measurements. In particular, we implemented the modulation of the compensation voltage with the synchronous demodulation of the ion current. The analysis of the measurements at low concentration levels led to an extrapolated limit of detection for acetone of 10 ppt with an averaging time of 1 s.
- 1 March 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (3) , 035115
Open AccessHigh sensitivity field asymmetric ion mobility spectrometer
A high sensitivity field asymmetric ion mobility spectrometer (FAIMS) was designed, fabricated, and tested. The main components of the system are a 10.6 eV UV photoionization source, an ion filter driven by a high voltage/high frequency n-MOS inverter circuit, and a low noise ion detector. The ion filter electronics are capable to generate square waveforms with peak-to-peak voltages up to 1000 V at frequencies up to 1 MHz with adjustable duty cycles. The ion detector current amplifier has a gain up to 1012 V/A with an effective equivalent input noise level down to about 1 fA/Hz1/2 during operation with the ion filter at the maximum voltage and frequency. The FAIMS system was characterized by detecting different standard chemical compounds. Additionally, we investigated the use of a synchronous modulation/demodulation technique to improve the signal-to-noise ratio in FAIMS measurements. In particular, we implemented the modulation of the compensation voltage with the synchronous demodulation of the ion current. The analysis of the measurements at low concentration levels led to an extrapolated limit of detection for acetone of 10 ppt with an averaging time of 1 s.
- Open Access
- 26 October 2016
- Published by Sissa Medialab Srl
- Vol. 240, 139
Hard X-Ray Tomographic Spectroscopy In Tcv
- 26 October 2016
- Published by Sissa Medialab Srl
- Vol. 240, 139
Open AccessHard X-Ray Tomographic Spectroscopy In Tcv
- Open Access
- 26 October 2016
- Published by Sissa Medialab Srl
- Vol. 240, 140
Electron Cyclotron Emission (Ece) And Correlation Ece Diagnostic On Tcv
- 26 October 2016
- Published by Sissa Medialab Srl
- Vol. 240, 140
Open AccessElectron Cyclotron Emission (Ece) And Correlation Ece Diagnostic On Tcv
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 96-97, 597-601
Upgrade of a 30 kV/10 mA anode power supply for triode type gyrotron
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 96-97, 597-601
Upgrade of a 30 kV/10 mA anode power supply for triode type gyrotron
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 96-97, 878-881
Development of the ITER Continuous External Rogowski: From conceptual design to final design
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 96-97, 878-881
Development of the ITER Continuous External Rogowski: From conceptual design to final design