Doina Margareta Gordin
Research Subjects
Doina Margareta Gordin has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
T. Gloriant
INSA Rennes, CNRS, ISCR, UMR6226, Rennes, France
20 shared publicationsThierry Gloriant
Univ Rennes INSA Rennes, CNRS, ISCR‐UMR 6226F‐35000 Rennes France
10 shared publications- Anisoara Cimpean
Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania
8 shared publications - Cora Vasilescu
Institute of Physical Chemistry “Ilie Murgulescu” of Romanian Academy
8 shared publications D. Ansel
Institut National des Sciences Applique´es de Rennes (INSA Rennes), Groupe de Recherche en Chimie-Me´tallurgie (GRCM-EA2620), 20 avenue des Buttes de Coe¨smes, F-35043 Rennes cedex, France
8 shared publications- Isabelle Thibon
Intelligence and national security alliance
8 shared publications
Latest Publications
- 15 October 2026
- Published by SAGE Publications in Journal of Dental Research
Peri-implant Soft Tissue Cell Behavior on Experimental β-Ti Alloys
Titanium alloys based on Ti6Al4V (TA6V) are widely employed as metallic materials for dental implants owing to their overall mechanical and biological performance. However, challenges remain, particularly the mismatch in elastic modulus between the alloy and bone tissue, as well as concerns regarding the potential release of cytotoxic ions such as aluminum (Al) and vanadium (V). Therefore, optimizing alloy composition is crucial to improve peri-implant tissue integration and enhance long-term implant stability. In this in vitro study, the cytocompatibility of a newly developed β-titanium alloy, Ti20Zr3Mo (at%) free of Al and V and exhibiting a reduced elastic modulus compared to that of TA6V, was evaluated using primary human gingival fibroblasts, representative of peri-implant soft tissues. The experimental alloy was compared to conventional TA6V and commercially pure titanium (Cp-Ti40). Several endpoints were investigated to characterize cell–material interactions. Cell viability and cytotoxicity were analyzed by Live/Dead fluorescence staining, while metabolic activity was assessed using the Alamar Blue assay. Cell adhesion and surface colonization were observed through scanning electron microscopy and confocal laser imaging. In addition, extracellular matrix production, including collagen deposition, was examined to evaluate the potential for soft tissue integration. Results demonstrated that Ti20Zr3Mo alloy supported comparable cell viability to Cp-Ti40 while exhibiting enhanced surface colonization by fibroblasts. These findings suggest that the substitution of Al and V with Zr and Mo in specific proportions may promote suitable fibroblast–Ti-alloy interactions, which could improve peri-implant soft tissue sealing and contribute to the long-term success of dental implants. This work highlights a promising strategy for developing next-generation titanium alloys that combine improved biological responses with suitable mechanical properties, with the ultimate goal of enhancing the long-term clinical performance of dental implants.
- 15 October 2026
- Published by SAGE Publications in Journal of Dental Research
Peri-implant Soft Tissue Cell Behavior on Experimental β-Ti Alloys
Titanium alloys based on Ti6Al4V (TA6V) are widely employed as metallic materials for dental implants owing to their overall mechanical and biological performance. However, challenges remain, particularly the mismatch in elastic modulus between the alloy and bone tissue, as well as concerns regarding the potential release of cytotoxic ions such as aluminum (Al) and vanadium (V). Therefore, optimizing alloy composition is crucial to improve peri-implant tissue integration and enhance long-term implant stability. In this in vitro study, the cytocompatibility of a newly developed β-titanium alloy, Ti20Zr3Mo (at%) free of Al and V and exhibiting a reduced elastic modulus compared to that of TA6V, was evaluated using primary human gingival fibroblasts, representative of peri-implant soft tissues. The experimental alloy was compared to conventional TA6V and commercially pure titanium (Cp-Ti40). Several endpoints were investigated to characterize cell–material interactions. Cell viability and cytotoxicity were analyzed by Live/Dead fluorescence staining, while metabolic activity was assessed using the Alamar Blue assay. Cell adhesion and surface colonization were observed through scanning electron microscopy and confocal laser imaging. In addition, extracellular matrix production, including collagen deposition, was examined to evaluate the potential for soft tissue integration. Results demonstrated that Ti20Zr3Mo alloy supported comparable cell viability to Cp-Ti40 while exhibiting enhanced surface colonization by fibroblasts. These findings suggest that the substitution of Al and V with Zr and Mo in specific proportions may promote suitable fibroblast–Ti-alloy interactions, which could improve peri-implant soft tissue sealing and contribute to the long-term success of dental implants. This work highlights a promising strategy for developing next-generation titanium alloys that combine improved biological responses with suitable mechanical properties, with the ultimate goal of enhancing the long-term clinical performance of dental implants.
- 6 July 2026
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 114 (7) , e70119
Superelastic Ti‐Zr‐Nb‐Sn Thin Films Fabricated by Magnetron Sputtering: Biocompatibility and Bacterial Biofilm Formation Assessment for Orthopedic Applications
Nickel‐titanium (NiTi) alloys are widely used in orthopedics because of their excellent mechanical properties; however, hypersensitivity remains a concern because of Ni ion release during long‐term implantation. To address this issue, we manufactured Ti‐Zr‐xNb‐Sn thin films ( x = 10, 15, 17, 20 at.%) using magnetron‐sputtering, intended as coatings for NiTi devices. Given the superelasticity of Ti‐Zr‐Nb‐Sn alloys, these coatings are expected to not only suppress the Ni ion release from the NiTi substrate but also reduce the formation of cracks in the coating by accommodating the substrate's deformation. The biocompatibility of the coatings was evaluated both in vitro and in vivo, as well as the potential risk of forming bacterial biofilms. Ti‐Zr‐xNb‐Sn coatings ( x = 15, 17 at.%) promoted pre‐osteoblast differentiation compared to uncoated NiTi, without increasing the risk of biofilm formation by Staphylococcus epidermidis . The coated NiTi wires were implanted subcutaneously in mice for 28 days, and no strong rejection reaction was observed compared to uncoated NiTi. Additionally, the coatings showed superior corrosion resistance, indicating improved long‐term stability. The deposition angle during sputtering influenced cell differentiation, suggesting that both chemical composition and surface morphology contribute to osteogenic responses. Overall, Ti‐Zr‐Nb‐Sn coatings are a promising surface modification strategy for NiTi orthopedic implants.
- 6 July 2026
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 114 (7) , e70119
Superelastic Ti‐Zr‐Nb‐Sn Thin Films Fabricated by Magnetron Sputtering: Biocompatibility and Bacterial Biofilm Formation Assessment for Orthopedic Applications
Nickel‐titanium (NiTi) alloys are widely used in orthopedics because of their excellent mechanical properties; however, hypersensitivity remains a concern because of Ni ion release during long‐term implantation. To address this issue, we manufactured Ti‐Zr‐xNb‐Sn thin films ( x = 10, 15, 17, 20 at.%) using magnetron‐sputtering, intended as coatings for NiTi devices. Given the superelasticity of Ti‐Zr‐Nb‐Sn alloys, these coatings are expected to not only suppress the Ni ion release from the NiTi substrate but also reduce the formation of cracks in the coating by accommodating the substrate's deformation. The biocompatibility of the coatings was evaluated both in vitro and in vivo, as well as the potential risk of forming bacterial biofilms. Ti‐Zr‐xNb‐Sn coatings ( x = 15, 17 at.%) promoted pre‐osteoblast differentiation compared to uncoated NiTi, without increasing the risk of biofilm formation by Staphylococcus epidermidis . The coated NiTi wires were implanted subcutaneously in mice for 28 days, and no strong rejection reaction was observed compared to uncoated NiTi. Additionally, the coatings showed superior corrosion resistance, indicating improved long‐term stability. The deposition angle during sputtering influenced cell differentiation, suggesting that both chemical composition and surface morphology contribute to osteogenic responses. Overall, Ti‐Zr‐Nb‐Sn coatings are a promising surface modification strategy for NiTi orthopedic implants.
- Open Access
- 1 January 2021
- Published by Central Library of the Slovak Academy of Sciences in Metallic Materials
- Vol. 53 (01) , 17-26
XRD and nanoindentation testing of thermo-mechanical processed Ti-29Nb-9Ta-10Zr alloy
XRD and nanoindentation testing of thermo-mechanical processed Ti-29Nb-9Ta-10Zr alloy
- 1 January 2021
- Published by Central Library of the Slovak Academy of Sciences in Metallic Materials
- Vol. 53 (01) , 17-26
Open AccessXRD and nanoindentation testing of thermo-mechanical processed Ti-29Nb-9Ta-10Zr alloy
XRD and nanoindentation testing of thermo-mechanical processed Ti-29Nb-9Ta-10Zr alloy
- Open Access
- 25 October 2015
- Published by Hindawi Limited in BioMed Research International
- Vol. 2015, 1-14
Biological Behaviour and Enhanced Anticorrosive Performance of the Nitrided Superelastic Ti-23Nb-0.7Ta-2Zr-0.5N Alloy
The influence of gas nitriding surface treatment on the superelastic Ti-23Nb-0.7Ta-2Zr-0.5N alloy was evaluated. A thorough characterization of bare and nitrided Ti-based alloy and pure Ti was performed in terms of surface film composition and morphology, electrochemical behaviour, and short term osteoblast response. XPS analysis showed that the nitriding treatment strongly influenced the composition (nitrides and oxynitrides) and surface properties both of the substrate and of the bulk alloy. SEM images revealed that the nitrided surface appears as a similar dotted pattern caused by the formation of N-rich domains coexisting with less nitrided domains, while before treatment only topographical features could be observed. All the electrochemical results confirmed the high chemical stability of the nitride and oxynitride coating and the superiority of the applied treatment. The values of the corrosion parameters ascertained the excellent corrosion resistance of the coated alloy in the real functional conditions from the human body. Cell culture experiments with MG63 osteoblasts demonstrated that the studied biomaterials do not elicit any toxic effects and support cell adhesion and enhanced cell proliferation. Altogether, these data indicate that the nitrided Ti-23Nb-0.7Ta-2Zr-0.5N alloy is the most suitable substrate for application in bone implantology. The influence of gas nitriding surface treatment on the superelastic Ti-23Nb-0.7Ta-2Zr-0.5N alloy was evaluated. A thorough characterization of bare and nitrided Ti-based alloy and pure Ti was performed in terms of surface film composition and morphology, electrochemical behaviour, and short term osteoblast response. XPS analysis showed that the nitriding treatment strongly influenced the composition (nitrides and oxynitrides) and surface properties both of the substrate and of the bulk alloy. SEM images revealed that the nitrided surface appears as a similar dotted pattern caused by the formation of N-rich domains coexisting with less nitrided domains, while before treatment only topographical features could be observed. All the electrochemical results confirmed the high chemical stability of the nitride and oxynitride coating and the superiority of the applied treatment. The values of the corrosion parameters ascertained the excellent corrosion resistance of the coated alloy in the real functional conditions from the human body. Cell culture experiments with MG63 osteoblasts demonstrated that the studied biomaterials do not elicit any toxic effects and support cell adhesion and enhanced cell proliferation. Altogether, these data indicate that the nitrided Ti-23Nb-0.7Ta-2Zr-0.5N alloy is the most suitable substrate for application in bone implantology.
- 25 October 2015
- Published by Hindawi Limited in BioMed Research International
- Vol. 2015, 1-14
Open AccessBiological Behaviour and Enhanced Anticorrosive Performance of the Nitrided Superelastic Ti-23Nb-0.7Ta-2Zr-0.5N Alloy
The influence of gas nitriding surface treatment on the superelastic Ti-23Nb-0.7Ta-2Zr-0.5N alloy was evaluated. A thorough characterization of bare and nitrided Ti-based alloy and pure Ti was performed in terms of surface film composition and morphology, electrochemical behaviour, and short term osteoblast response. XPS analysis showed that the nitriding treatment strongly influenced the composition (nitrides and oxynitrides) and surface properties both of the substrate and of the bulk alloy. SEM images revealed that the nitrided surface appears as a similar dotted pattern caused by the formation of N-rich domains coexisting with less nitrided domains, while before treatment only topographical features could be observed. All the electrochemical results confirmed the high chemical stability of the nitride and oxynitride coating and the superiority of the applied treatment. The values of the corrosion parameters ascertained the excellent corrosion resistance of the coated alloy in the real functional conditions from the human body. Cell culture experiments with MG63 osteoblasts demonstrated that the studied biomaterials do not elicit any toxic effects and support cell adhesion and enhanced cell proliferation. Altogether, these data indicate that the nitrided Ti-23Nb-0.7Ta-2Zr-0.5N alloy is the most suitable substrate for application in bone implantology. The influence of gas nitriding surface treatment on the superelastic Ti-23Nb-0.7Ta-2Zr-0.5N alloy was evaluated. A thorough characterization of bare and nitrided Ti-based alloy and pure Ti was performed in terms of surface film composition and morphology, electrochemical behaviour, and short term osteoblast response. XPS analysis showed that the nitriding treatment strongly influenced the composition (nitrides and oxynitrides) and surface properties both of the substrate and of the bulk alloy. SEM images revealed that the nitrided surface appears as a similar dotted pattern caused by the formation of N-rich domains coexisting with less nitrided domains, while before treatment only topographical features could be observed. All the electrochemical results confirmed the high chemical stability of the nitride and oxynitride coating and the superiority of the applied treatment. The values of the corrosion parameters ascertained the excellent corrosion resistance of the coated alloy in the real functional conditions from the human body. Cell culture experiments with MG63 osteoblasts demonstrated that the studied biomaterials do not elicit any toxic effects and support cell adhesion and enhanced cell proliferation. Altogether, these data indicate that the nitrided Ti-23Nb-0.7Ta-2Zr-0.5N alloy is the most suitable substrate for application in bone implantology.
- 6 March 2015
- Published by Springer Nature in JOM
- Vol. 67 (4) , 818-829
Corrosion Behaviour of Nitrogen-Implantation Ti-Ta-Nb Alloy in Physiological Solutions Simulating Real Conditions from Human Body
- 6 March 2015
- Published by Springer Nature in JOM
- Vol. 67 (4) , 818-829
Corrosion Behaviour of Nitrogen-Implantation Ti-Ta-Nb Alloy in Physiological Solutions Simulating Real Conditions from Human Body
- 1 February 2015
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 47, 105-113
In vitro performance assessment of new beta Ti–Mo–Nb alloy compositions
- 1 February 2015
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 47, 105-113
In vitro performance assessment of new beta Ti–Mo–Nb alloy compositions
- 7 January 2015
- Published by Wiley in Materials and Corrosion
- Vol. 66 (9) , 982-994
Modelling the influence of pH, fluoride, and caffeine on the corrosion resistance of TiMo alloys by artificial neural networks developed with differential evolution algorithm
- 7 January 2015
- Published by Wiley in Materials and Corrosion
- Vol. 66 (9) , 982-994
Modelling the influence of pH, fluoride, and caffeine on the corrosion resistance of TiMo alloys by artificial neural networks developed with differential evolution algorithm
- 1 January 2015
- Published by Elsevier in Transactions of Nonferrous Metals Society of China
- Vol. 25 (1) , 345-352
Electrochemical characterization of Ti12Mo5Ta alloys in contact with saline medium
- 1 January 2015
- Published by Elsevier in Transactions of Nonferrous Metals Society of China
- Vol. 25 (1) , 345-352
Electrochemical characterization of Ti12Mo5Ta alloys in contact with saline medium
- 1 November 2014
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 44, 362-370
Potentiality of the “Gum Metal” titanium-based alloy for biomedical applications
- 1 November 2014
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 44, 362-370
Potentiality of the “Gum Metal” titanium-based alloy for biomedical applications