TTTakashi Tateno

Takashi Tateno

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takashi Tateno has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Hisayuki Osanai

    Department of Psychiatry, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA

    8 shared publications
  • Jun Nishikawa

    Graduate School of Information Science and Technology Hokkaido University, Kita 14, Nishi 9, Kita‐ku Sapporo 060‐0814 Japan

    6 shared publications
  • Ryo Furukawa

    Graduate School of Information Science and Technology, Hokkaido University, Kita 14, Nishi 9, Kita-ku, Sapporo, 060-0814, Japan

    4 shared publications
  • Shunsuke Minusa

    Research and Development Group, Center for Exploratory Research, Hitachi Ltd, Tokyo, Japan

    4 shared publications
  • Kazuo Satoh

    Osaka Research Institute of Industrial Science and Technology, 2‐7‐1, Ayumino, Izumi Osaka 594‐1157 Japan

    3 shared publications
  • Shuichi Murakami

    Osaka Research Institute of Industrial Science and Technology, 2‐7‐1, Ayumino, Izumi Osaka 594‐1157 Japan

    3 shared publications

Latest Publications

  • Effective Temporal Envelopes for Transcranial Ultrasound Stimulation in the Absence of Auditory Peripheral Responses

    by Ryo Furukawa, Kosei Shiba, Takashi Tateno

    Objective: Transcranial ultrasound (US) stimulation (TUS) has emerged as a promising technique for minimally invasive, localized, deep brain stimulation. However, indirect auditory effects during neuromodulation require careful consideration, particularly in experiments with rodents. One method to prevent auditory responses involves applying tapered envelopes to US bursts. However, the specific mechanisms by which these envelopes affect both auditory and nonauditory responses remain unclear. In this study, we aimed to elucidate the relationship between the temporal patterns of TUS and their effects on auditory responses. Methods: We manipulated two key temporal parameters of the US stimulation envelope: the stimulus duration (0.05 or 1.0 ms) and the window rate of the rise/fall tapering (0%–45%); their effects were assessed using multiple experimental modalities and computational simulations. The simulations were conducted to analyze the energy spectrum of the acoustic pressure at the skull surface. Acoustic emission (AE) recordings were performed in vivo using piezoelectric sensors attached to the mouse skull. Auditory responses were evaluated in anesthetized mice by recording auditory brainstem responses (ABRs) to assess peripheral auditory activity, and local field potentials (LFPs) in the auditory cortex to assess central auditory activity. These complementary measurements enabled the differentiation between peripheral and central auditory effects based on response latencies and waveform characteristics. Results: We found that the energy within the audible frequency range at the skull decreased monotonically with increasing tapering window rates, as demonstrated by both simulations and AE measurements. Correspondingly, little to no peripheral auditory activity, as indicated by detectable auditory brainstem responses (ABRs), was observed within a specific range of tapering window rates and stimulation durations. Furthermore, we successfully evoked cortical activity without a detectable peripheral auditory response, using a shorter tapering window (<15%) than previously reported. Despite the absence or reduction of peripheral auditory responses, reliable cortical LFPs were still elicited, confirming that TUS can activate central auditory neurons while minimizing peripheral auditory input. Conclusion: Frequency analyses from both simulation and AE recordings revealed a monotonic reduction of audible acoustic components with increased tapering. Importantly, we demonstrated that cortical activation could be achieved without substantial peripheral auditory activation. Significance: Our findings provide a framework for optimizing temporal parameters of TUS to minimize confounding auditory effects in rodent neuromodulation studies.

  • Open Access

    Localized Theta-Burst Magnetic Stimulation Induces Bidirectional Neural Modulation in the Mouse Auditory Cortex In Vivo

    by Takahiro Yoshikawa, Takashi Tateno

    Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive method that has been used to treat various brain disorders. The modulatory effects of rTMS can be adjusted by changing the repetition patterns. Theta-burst magnetic stimulation (TBS) is a magnetic stimulation pattern that can induce long-lasting modulatory effects with a short stimulation period. However, its effects on auditory brain regions remain unclear because of a lack of animal studies in which invasive techniques allow for a detailed exploration of the underlying neural mechanisms. In the current study, we investigated the effects of TBS on the C57BL/6J mouse auditory cortex using a custom-built 7 mm magnetic stimulation coil. Extracellular recordings were made before, during, and after the application of intermittent TBS (iTBS), continuous TBS (cTBS), or sham stimulation. Local field potential amplitudes were increased for 5–20 min post-iTBS compared with the sham condition and were decreased at 10 min post-cTBS compared with the sham condition. The bidirectional modulatory effects observed in our study are consistent with previous findings from other brain regions. Additionally, multiunit activities were significantly altered in cortical layers 2/3 and 4 but not layer 5, indicating that the modulatory effects were localized to the surface region of the auditory cortex. Interestingly, in the iTBS group, the amplitude of average spike waveforms increased with a 15 min delay. Our findings provide physiological evidence of TBS modulation of the rodent auditory cortex and may guide future research seeking to optimize rTMS for modulating hearing abilities.


  • Open Access

    Analyzing the transient response dynamics of long-term depression in the mouse auditory cortex in vitro through multielectrode-array-based spatiotemporal recordings

    by Ryo Furukawa, Kouta Kume, Takashi Tateno

    In the auditory cortex, synaptic plasticity, including long-term potentiation (LTP) and long-term depression (LTD), plays crucial roles in information processing and adaptation to the auditory environment. Previous rodent studies have shown lifelong cortical map plasticity, even beyond the critical period of development. While thalamocortical synapses exhibit LTD during the critical period, little is known about LTD in the cortico-cortical connections of the adult mouse auditory cortex. Here, we investigated the transient response dynamics of LTD in layers 2–5 of the mouse auditory cortex following tetanic stimulation (TS) to layer 4. To characterize LTD properties, we developed a recording protocol to monitor activity levels at multiple sites, including those more than 0.45 mm from the TS site. This allowed us to distinguish LTD-induced reductions in neural excitability from other types, including neural activity depletion. Our findings revealed that LTD induced in layer 4 persisted for over 40-min post-TS, indicating robust cortico-cortical LTD. Using electrophysiological data and a modified synaptic model, we identified key receptors involved in synaptic plasticity and their effects on response dynamics, proposing a method for studying LTD in the mature mouse auditory cortex. Particularly, by employing a simple dynamical model, we analyzed and discussed the involvement of key receptors during the transient period of LTD. This study expands our understanding of synaptic plasticity in the mature mouse auditory cortex beyond the critical period, potentially informing future treatments for hearing disorders.


  • Open Access

    Modulatory Effects on Laminar Neural Activity Induced by Near-Infrared Light Stimulation with a Continuous Waveform to the Mouse Inferior Colliculus In Vivo

    by Hiromu Sato, Futoshi Sugimoto, Ryo Furukawa, Takashi Tateno

    Infrared neural stimulation (INS) is a promising area of interest for the clinical application of a neuromodulation method. This is in part because of its low invasiveness, whereby INS modulates the activity of the neural tissue mainly through temperature changes. Additionally, INS may provide localized brain stimulation with less tissue damage. The inferior colliculus (IC) is a crucial auditory relay nucleus and a potential target for clinical application of INS to treat auditory diseases and develop artificial hearing devices. Here, using continuous INS with low to high-power density, we demonstrate the laminar modulation of neural activity in the mouse IC in the presence and absence of sound. We investigated stimulation parameters of INS to effectively modulate the neural activity in a facilitatory or inhibitory manner. A mathematical model of INS-driven brain tissue was first simulated, temperature distributions were numerically estimated, and stimulus parameters were selected from the simulation results. Subsequently, INS was administered to the IC of anesthetized mice, and the modulation effect on the neural activity was measured using an electrophysiological approach. We found that the modulatory effect of INS on the spontaneous neural activity was bidirectional between facilitatory and inhibitory effects. The modulatory effect on sound-evoked responses produced only an inhibitory effect to all examined stimulus intensities. Thus, this study provides important physiological evidence on the response properties of IC neurons to INS. Overall, INS can be used for the development of new therapies for neurological disorders and functional support devices for auditory central processing.


  • Low-Cost Electroencephalographic Recording System Combined with a Millimeter-Sized Coil to Transcranially Stimulate the Mouse Brain In Vivo

    by Takahiro Yoshikawa, Hiromu Sato, Koki Kawakatsu, Takashi Tateno

    A low-cost electroencephalographic (EEG) recording system is proposed here to drive transcranial magnetic stimulation (TMS) of the mouse brain in vivo, utilizing a millimeter-sized coil. Using conventional screw electrodes combined with a custom-made, flexible, multielectrode array substrate, multi-site recording can be carried out from the mouse brain. In addition, we explain how a millimeter-sized coil is produced using low-cost equipment usually found in laboratories. Practical procedures for fabricating the flexible multielectrode array substrate and the surgical implantation technique for screw electrodes are also presented, which are necessary to produce low-noise EEG signals. Although the methodology is useful for recording from the brain of any small animal, the present report focuses on electrode implementation in an anesthetized mouse skull. Furthermore, this method can be easily extended to an awake small animal that is connected with tethered cables via a common adapter and fixed with a TMS device to the head during recording.The present version of the EEG-TMS system, which can include a maximum of 32 EEG channels (a device with 16 channels is presented as an example with fewer channels) and one TMS channel device, is described. Additionally, typical results obtained by the application of the EEG-TMS system to anesthetized mice are briefly reported.


  • Open Access

    A Multielectrode Array-Based Recording System for Analyzing Ultrasound-Driven Neural Responses in Brain Slices in vitro

    by Ryo Furukawa, Hiroki Kaneta, Takashi Tateno

    Ultrasound stimulation is expected to be useful for transcranial local and deep stimulation of the brain, which is difficult to achieve using conventional electromagnetic stimulation methods. Previous ultrasound stimulation experiments have used various types of acute in vitro preparations, including hippocampus slices from rodents and Caenorhabditis elegans tissue. For in vivo preparations, researchers have used the cortices of rodents as targets for transcranial ultrasound stimulation. However, no previous studies have used in vitro ultrasound stimulation in rodent cortical slices to examine the mechanisms of ultrasound-driven central neural circuits. Here we demonstrate the optimal experimental conditions for an in vitro ultrasound stimulation system for measuring activity in brain slices using a multielectrode array substrate. We found that the peak amplitudes of the ultrasound-evoked cortical responses in the brain slices depend on the intensities and durations of the ultrasound stimulation parameters. Thus, our findings provide a new in vitro experimental setup that enables activation of a brain slice via ultrasound stimulation. Accordingly, our results indicate that choosing the appropriate ultrasound waveguide structure and stimulation parameters is important for producing the desired intensity distribution in a localized area within a brain slice. We expect that this experimental setup will facilitate future exploration of the mechanisms of ultrasound-driven neural activity.