MWMoritz Christoph Wurnig

Moritz Christoph Wurnig

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Moritz Christoph Wurnig has a total of 239 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Advanced diffusion imaging of abdominal organs in different hydration states of the human body: stability of biomarkers

    by Jūratė Kemėšienė, Alexander Rühle, Ryszard Gomolka, Moritz C. Wurnig, Cristina Rossi, Andreas Boss


  • Imaging of the peripheral nervous system

    by Lorenz Grunder, Roman Guggenberger, Moritz C. Wurnig


  • Open Access

    B-Value Optimization in the Estimation of Intravoxel Incoherent Motion Parameters in Patients with Cervical Cancer

    by Jose Angelo Udal Perucho, Hing Chiu Charles Chang, Varut Vardhanabhuti, Mandi Wang, Anton Sebastian Becker, Moritz Christoph Wurnig, Elaine Yuen Phin Lee

    Perucho JA, et al. Korean J Radiol. 2020 Feb;21(2):218-227. https://doi.org/10.3348/kjr.2019.0232


  • Diffusion tensor imaging of the abdominal organs: Influence of oriented intravoxel flow compartments

    by Valerie Phi van, Caecilia S. Reiner, Markus Klarhoefer, Alexander Ciritsis, Christian Eberhardt, Moritz C. Wurnig, Cristina Rossi

    Water flow in partially oriented intravoxel compartments mimics an anisotropic fast‐diffusion regime, which contributes to the signal attenuation in diffusion‐weighted images. In the abdominal organs, this flow may reflect physiological fluid movements (eg, tubular urine flow in kidneys, or bile flow through the liver) and have a clinical relevance. This study investigated the influence of anisotropic intravoxel water flow on diffusion tensor imaging (DTI) of the abdominal organs.Diffusion‐weighted images were acquired in five healthy volunteers using an EPI sequence with diffusion preparation (TR/TE: 1000 ms/71 ms; b‐values: 0, 10, 20, 40, 70, 120, 250, 450, 700, 1000 s/mm2; 12 noncollinear diffusion‐encoding directions). DTI of liver and kidneys was performed assuming (i) monoexponential decay of the diffusion‐weighted signal, and (ii) accounting for potential anisotropy of the fast‐diffusion compartments using a tensorial generalization of the IVIM model. Additionally, potential dependency of the metrics of the tensors from the anatomical location was evaluated.Significant differences in the metrics of the diffusion tensor (DT) were found in both liver and kidneys when comparing the two models. In both organs, the trace and the fractional anisotropy of the DT were significantly higher in the monoexponential model than when accounting for perfusion. The comparison of areas of the liver proximal to the hilum with distal regions and of renal cortex with the medulla also proved a location dependency of the size of the fast‐diffusion compartments.Pseudo‐diffusion correction in DTI enables the assessment of the solid parenchyma regardless of the organ perfusion or other pseudo‐diffusive fluid movements. This may have a clinical relevance in the assessment of parenchymal pathologies (eg, liver fibrosis). The fast pseudo‐diffusion components present a detectable anisotropy, which may reflect the hepatic microcirculation or other sources of mesoscopic fluid movement in the abdominal organs.


  • Transient steatosis assessed by magnetic resonance imaging predicts outcome after extended hepatectomy in mice

    by Andrea Wirsching, Christian Eberhardt, Moritz C. Wurnig, Andreas Boss, Mickaël Lesurtel


  • Intravoxel Incoherent Motion

    by Alexander Ciritsis, Cristina Rossi, Moritz C. Wurnig, Valerie Phi Van, Andreas Boss

    Purpose: For diffusion data sets including low and high b-values, the intravoxel incoherent motion model is commonly applied to characterize tissue. The aim of the present study was to show that machine learning allows a model-free approach to determine tissue type without a priori assumptions on the underlying physiology. Materials and Methods: In 8 healthy volunteers, diffusion data sets were acquired using an echo-planar imaging sequence with 16 b-values in the range between 0 and 1000 s/mm2. Using the k-nearest neighbors technique, the machine learning algorithm was trained to distinguish abdominal organs (liver, kidney, spleen, muscle) using the signal intensities at different b-values as training features. For systematic variation of model complexity (number of neighbors), performance was assessed by calculation of the accuracy and the kappa coefficient (κ). Most important b-values for tissue discrimination were determined by principal component analysis. Results: The optimal trade-off between model complexity and overfitting was found in the range between K = 11 to 13. On “real-world” data not previously applied to optimize the algorithm, the k-nearest neighbors algorithm was capable to accurately distinguish tissue types with best accuracy of 94.5% and κ = 0.92 reached for intermediate model complexity (K = 11). The principal component analysis showed that most important b-values are (with decreasing importance): b = 1000 s/mm2, b = 970 s/mm2, b = 750 s/mm2, b = 20 s/mm2, b = 620 s/mm2, and b = 40 s/mm2. Applying a reduced set of 6 most important b-values, still a similar accuracy was achieved on the real-world data set with an average accuracy of 93.7% and a κ coefficient of 0.91. Conclusions: Machine learning allows for a model-free determination of tissue type using intra voxel incoherent motion signal decay curves as features. The technique may be useful for segmentation of abdominal organs or distinction between healthy and pathological tissues.


  • Is there evidence for more than two diffusion components in abdominal organs? – A magnetic resonance imaging study in healthy volunteers

    by Moritz C. Wurnig, Manon Germann, Andreas Boss

    The most commonly applied model for the description of diffusion‐weighted imaging (DWI) data in perfused organs is bicompartmental intravoxel incoherent motion (IVIM) analysis. In this study, we assessed the ground truth of underlying diffusion components in healthy abdominal organs using an extensive DWI protocol and subsequent computation of apparent diffusion coefficient ‘spectra’, similar to the computation of previously described T2 relaxation spectra. Diffusion datasets of eight healthy subjects were acquired in a 3‐T magnetic resonance scanner using 68 different b values during free breathing (equidistantly placed in the range 0–1005 s/mm2). Signal intensity curves as a function of the b value were analyzed in liver, spleen and kidneys using non‐negative least‐squares fitting to a distribution of decaying exponential functions with minimum amplitude energy regularization. In all assessed organs, the typical slow‐ and fast‐diffusing components of the IVIM model were detected [liver: true diffusion D = (1.26 ± 0.01) × 10–3 mm2/s, pseudodiffusion D* = (270 ± 44) × 10–3 mm2/s; kidney cortex: D = (2.26 ± 0.07) × 10–3 mm2/s, D* = (264 ± 78) × 10–3 mm2/s; kidney medulla: D = (1.57 ± 0.28) × 10–3 mm2/s, D* = (168 ± 18) × 10–3 mm2/s; spleen: D = (0.91 ± 0.01) × 10–3 mm2/s, D* = (69.8 ± 0.50) × 10–3 mm2/s]. However, in the liver and kidney, a third component between D and D* was found [liver: D′ = (43.8 ± 5.9) × 10–3 mm2/s; kidney cortex: D′ = (23.8 ± 11.5) × 10–3 mm2/s; kidney medulla: D′ = (5.23 ± 0.93) × 10–3 mm2/s], whereas no third component was detected in the spleen. Fitting with a diffusion kurtosis model did not lead to a better fit of the resulting curves to the acquired data compared with apparent diffusion coefficient spectrum analysis. For a most accurate description of diffusion properties in the liver and the kidneys, a more sophisticated model seems to be required including three diffusion components.


  • Top Cited Papers

    Deep Learning in Mammography

    by Anton S. Becker, Magda Marcon, Soleen Ghafoor, Moritz C. Wurnig, Thomas Frauenfelder, Andreas Boss

    Objectives: The aim of this study was to evaluate the diagnostic accuracy of a multipurpose image analysis software based on deep learning with artificial neural networks for the detection of breast cancer in an independent, dual-center mammography data set. Materials and Methods: In this retrospective, Health Insurance Portability and Accountability Act-compliant study, all patients undergoing mammography in 2012 at our institution were reviewed (n = 3228). All of their prior and follow-up mammographies from a time span of 7 years (2008–2015) were considered as a reference for clinical diagnosis. After applying exclusion criteria (missing reference standard, prior procedures or therapies), patients with the first diagnosis of a malignoma or borderline lesion were selected (n = 143). Histology or clinical long-term follow-up served as reference standard. In a first step, a breast density-and age-matched control cohort was selected (n = 143) from the remaining patients with more than 2 years follow-up (n = 1003). The neural network was trained with this data set. From the publicly available Breast Cancer Digital Repository data set, patients with cancer and a matched control cohort were selected (n = 35 × 2). The performance of the trained neural network was also tested with this external data set. Three radiologists (3, 5, and 10 years of experience) evaluated the test data set. In a second step, the neural network was trained with all cases from January to September and tested with cases from October to December 2012 (screening-like cohort). The radiologists also evaluated this second test data set. The areas under the receiver operating characteristic curve between readers and the neural network were compared. A Bonferroni-corrected P value of less than 0.016 was considered statistically significant. Results: Mean age of patients with lesion was 59.6 years (range, 35–88 years) and in controls, 59.1 years (35–83 years). Breast density distribution (A/B/C/D) was 21/59/42/21 and 22/60/41/20, respectively. Histologic diagnoses were invasive ductal carcinoma in 90, ductal in situ carcinoma in 13, invasive lobular carcinoma in 13, mucinous carcinoma in 3, and borderline lesion in 12 patients. In the first step, the area under the receiver operating characteristic curve of the trained neural network was 0.81 and comparable on the test cases 0.79 (P = 0.63). One of the radiologists showed almost equal performance (0.83, P = 0.17), whereas 2 were significantly better (0.91 and 0.94, P < 0.016). In the second step, performance of the neural network (0.82) was not significantly different from the human performance (0.77–0.87, P > 0.016); however, radiologists were consistently less sensitive and more specific than the neural network. Conclusions: Current state-of-the-art artificial neural networks for general image analysis are able to detect cancer in mammographies with similar accuracy to radiologists, even in a screening-like cohort with low breast cancer prevalence.


  • Rapid liver volume increase induced by associating liver partition with portal vein ligation for staged hepatectomy (ALPPS): Is it edema, steatosis, or true proliferation?

    by Dilmurodjon Eshmuminov, Christoph Tschuor, Dimitri Aristotle Raptis, Andreas Boss, Moritz C. Wurnig, Gregory Sergeant, Erik Schadde, Pierre-Alain Clavien


  • Early Mri-Based Liver Fat Quantificationpredicts Outcome After Extended Hepatectomy in Mice

    by Andrea Wirsching, Christian Eberhardt, Moritz C. Wurnig, Andreas Boss, Mickaël Lesurtel