PMPaula Moon-Massat

Paula Moon-Massat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paula Moon-Massat has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Treatment of Swine Closed Head Injury with Perfluorocarbon NVX-428

    by Francoise Arnaud, Ashraful Haque, Maj Erin Morris, Paula Moon-Massat, Charles Auker, Saha Biswajit, Brittany Hazzard, Lam Thuy Vi Tran Ho, Richard McCarron, Anke Scultetus

    Pre-hospital treatment of traumatic brain injury (TBI) with co-existing polytrauma is complicated by requirements for intravenous fluid volume vs. hypotensive resuscitation. A low volume, small particle-size-oxygen-carrier perfluorocarbon emulsion NVX-428 (dodecafluoropentane emulsion; 2% w/v) could improve brain tissue with minimal additional fluid volume. This study examined whether the oxygen-carrier NVX-428 shows safety and efficacy for pre-hospital treatment of TBI. Anesthetized swine underwent fluid percussion injury TBI and received 1 mL/kg IV NVX-428 (TBI-NVX) at 15 min (T15) or normal saline (no-treatment) (TBI-NON). Similarly, uninjured swine received NVX-428 (SHAM-NVX) or normal saline (SHAM-NON). Animals were monitored and measurements were taken for physiological and neurological parameters before euthanasia at the six-hour mark (T360). Histopathological analysis was performed on paraffin embedded tissues. Physiological, biochemical and blood gas parameters were not different, with the exception of a significant but transient increase in mean pulmonary artery pressure observed in the TBI-experimental group immediately after drug administration. There were no initial differences in brain oxygenation at baseline, but over time oxygen decreased ~50% in both TBI groups. Histological brain injury scores were similar between TBI-NVX and TBI-NON, although a number of subcategories (spongiosis-ischemic/dead neurons-hemorrhage-edema) in TBI-NVX had a tendency for lower scores. The cerebellum showed significantly lower spongiosis and ischemic/dead neuron injury scores and a lower number of Fluoro-Jade-B-positive cerebellar-Purkinje-cells after NVX-428 treatment compared to controls. NVX-428 may assist in mitigating secondary cellular brain damage.


  • Open Access

    Cerebral Microvascular and Systemic Effects Following Intravenous Administration of the Perfluorocarbon Emulsion Perftoran

    by Rania Abutarboush, Biswajit K. Saha, Saad H. Mullah, Francoise G. Arnaud, Ashraful Haque, Chioma Aligbe, Georgina Pappas, Charles R. Auker, Richard M. McCarron, Paula F. Moon-Massat, et al.

    Oxygen-carrying perfluorocarbon (PFC) fluids have the potential to increase tissue oxygenation during hypoxic states and to reduce ischemic cell death. Regulatory approval of oxygen therapeutics was halted due to concerns over vasoconstrictive side effects. The goal of this study was to assess the potential vasoactive properties of Perftoran by measuring brain pial arteriolar diameters in a healthy rat model. Perftoran, crystalloid (saline) or colloid (Hextend) solutions were administered as four sequential 30 min intravenous (IV) infusions, thus allowing an evaluation of cumulative dose-dependent effects. There were no overall changes in diameters of small-sized (<50 μm) pial arterioles within the Perftoran group, while both saline and Hextend groups exhibited vasoconstriction. Medium-sized arterioles (50–100 μm) showed minor (~8–9%) vasoconstriction within saline and Hextend groups and only ~5% vasoconstriction within the Perftoran group. For small- and medium-sized pial arterioles, the mean percent change in vessel diameters was not different among the groups. Although there was a tendency for arterial blood pressures to increase with Perftoran, pressures were not different from the other two groups. These data show that Perftoran, when administered to healthy anesthetized rats, does not cause additional vasoconstriction in cerebral pial arterioles or increase systemic blood pressure compared with saline or Hextend.


  • Sanguinate's effect on pial arterioles in healthy rats and cerebral oxygen tension after controlled cortical impact

    by Saad H. Mullah, Rania Abutarboush, Paula F. Moon-Massat, Biswajit K. Saha, Ashraful Haque, Peter B. Walker, Charles R. Auker, Francoise G. Arnaud, Richard M. McCarron, Anke H. Scultetus


  • Determination of methemoglobin and hemoglobin levels in small volume samples

    by Francoise Arnaud, Adam Higgins, Richard McCarron, Paula F. Moon-Massat

    Background/aims Hemoglobin-based oxygen carriers (HBOCs) have been previously studied as resuscitation fluids. Due to HBOCs specific molecular conformation, hemoglobin (Hb) and methemoglobin (MetHb) determination is not always possible with automated apparatus. A practical technique was designed that allows simultaneous reading of MetHb and Hb in small volume samples. Methods A spectrophotometric method for measuring low levels of MetHb and Hb from limited volume samples was developed using a 96-well-plate by downsizing the Evelyn-Malloy and Drabkin methods. Either blood or buffer samples were spiked with one of five HBOCs (HBOC-201, M101, MP4CO-NP, Sanguinate and Oxyvita C). After treatment with cyanides, the samples were read at 540, 630, and 680 nm, and Hb and MetHb results were compared to certificate-of-analysis. Results Hb levels ranging from 0.2 to 2.8 g/dl were detected accurately with the 96-well-plate method with HBOC-201. Similarly, this method accurately measured Hb from either plasma or buffer samples containing any of the HBOCs. The MetHb plasma samples with HBOC-201 were also in agreement with ABL results (R = 0.99719). MetHb from all HBOCs in buffer measured with this method was comparable to reference but the accuracy was compromised for HBOCs in blood. Conclusions A useful 96-well-plate method of measuring HBOCs’ Hb was designed for small-volume plasma samples. It was accurate for measuring MetHb from samples, that contained M101, MP4CO-NP, Sanguinate, and Oxyvita C diluted in buffer. This well-plate method allows reading of batch samples, multiple replicates, and using small volumes to accommodate limited animal blood collection which would not be otherwise detected by automated instrumentation.


  • Effects of Perfluorocarbon Dodecafluoropentane (NVX-108) on Cerebral Microvasculature in the Healthy Rat

    by Paula F. Moon-Massat, Rania Abutarboush, Georgina Pappas, Ashraful Haque, Chioma Aligbe, Francoise Arnaud, Charles Auker, Richard McCarron, Anke Scultetus

    NVX-108, a dodecafluoropentane-based perfluorocarbon (PFC) emulsion, has therapeutic potential as an oxygen- carrying fluid for emergency medical treatment for traumatic brain injury (TBI) and hemorrhagic shock. Potential cerebral vasoactive properties were assessed by directly measuring pial arteriolar vessel diameters before and after a 30 minute intravenous (IV) infusion of 1.0 ml/kg (high dose [H]) or 0.25 ml/kg (low dose [L]) NVX-108 compared to 2.0 ml/kg Saline (control) in healthy anesthetized rats (N = 6/group). Results showed that post-infusion vessel diameters for small (< 50 µm) and medium (50-100 µm)-sized pial arterioles were significantly (p < 0.05) narrower after only the NVX- 108 H infusion although this vasoconstriction was not statistically significant when analyzed as a percentage change in these vessels. Pial arteriolar vessel diameters were not significantly different for mean value or percentage change after either NVX-108 L or Saline infusions. There were no significant post-infusion changes from baseline in systolic, mean or diastolic blood pressures after any of the treatments although post-infusion blood pressure was statistically higher in the NVX-108 L group compared to NVX-108 H and Saline groups. Arterial blood gases, methemoglob in and lactate were not different from baseline or among groups. No adverse events were observed at either dose of NVX-108. In conclusion, neither 0.25 nor 1.0 ml/kg NVX-108 caused vasoconstriction in cerebral pial arterioles of healthy rats nor resulted in blood pressure changes; the compound should be considered for further investigation for TBI therapy.


  • Open Access

    Effects of oxygen affinity and viscosity of a hemoglobin‐based oxygen carrier (HBOC‐201) on systemic and microcirculatory variables in a top‐load rat model (674.2)

    by Bjorn Song, William Nugent, Paula Moon‐Massat, Roland Pittman

    The effects of oxygen affinity (P 50 ) and viscosity on arteriolar vasoactivity and tissue oxygen tension were explored by administering a polymerized bovine hemoglobin‐based oxygen carrier (HBOC) in a dose‐response fashion to normovolemic rats. The P 50 and viscosity, respectively, of the parent compound (HBOC‐201) and its modifications (MP50 and LP50A) were as follows: 40 mmHg and 3.0 cP (HBOC‐20l); 18 mmHg and 4.4 cP (MP50); and 17 mmHg and 12.1 cP (LP50A). Anesthetized male Sprague‐Dawley rats (N = 32) were randomized to receive one of the HBOC solutions, and were administered with four infusions that increased in concentration for each dose (2, 22, 230 and 780 mg/kg, IV). Data were compared to rats receiving an equivalent volume for each of the four infusions (0.4, 0.4, 3.8, 13.1 ml/kg, IV) of iso‐oncotic 5.9% human serum albumin (HSA). HBOC‐201, MP50 and HSA produced significant increases in MAP after Doses 3 and 4, whereas a similar increase began at a lower dose (Dose 2) with LP50A. There were no significant changes in arteriolar diameters at any dose for any group. Interstitial PO 2 remained unchanged for HBOC‐201, MP50 and HSA, but LP50A caused a significant decrease compared to baseline after Doses 3 and 4. In this healthy rat top‐load model, there was no evidence that HBOC‐201 would perform better with increased oxygen affinity (40 to 18 mmHg) or viscosity (3.0 to 4.4 cP). Grant Funding Source : Supported by BUMED congressional funding WUN 604771N.9737.001.A0315, and in part by R01 HL18292

  • The effect HBOC-201 and sodium nitrite resuscitation after uncontrolled haemorrhagic shock in swine

    by Paula Moon-Massat, Anke Scultetus, Françoise Arnaud, Ammon Brown, Ashraful Haque, Biswajit Saha, Bobby Kim, Eileen Sagini, Gerald McGwin, Charles Auker, et al.


  • Open Access

    TISSUE OXYGENATION AND OXYGEN CONSUMPTION FOLLOWING HEMORRHAGE AND RESUSCITATION USING A HEMOGLOBIN‐BASED OXYGEN CARRIER AND HUMAN SERUM ALBUMIN

    by Bjorn K Song, Michael D Connery, P. Moon‐Massat, Roland N Pittman

    This study compared the effects on O 2 transport of two resuscitation fluids: a hemoglobin‐based O 2 carrier (HBOC‐201, Biopure Corp., Cambridge, MA), and 5.9% human serum albumin (HSA), a non‐oxygen carrying colloid solution. Intravital microscopic measurements were made on the spinotrapezius muscle of anesthetized, male Sprague‐Dawley rats. Interstitial (ISF) PO 2 was measured using phosphorescence quenching microscopy at baseline, post‐hemorrhage and post‐resuscitation time points. Following hemorrhage (40% blood volume) the animal was maintained in this condition for 30 minutes before resuscitation. Local tissue O 2 consumption (VO 2 ) was proportional to the rate of decline of PO 2 following arrested flow from rapid inflation of a Saran bag placed around the microscope objective. In both groups (HBOC, N=4; HSA, N=4), baseline ISF PO 2 (~60 mmHg) decreased significantly during hemorrhage (to ~2 mmHg), and increased after resuscitation (to ~40 mmHg). Significant vasoconstriction and elevation of mean arterial pressure (MAP) was observed with HBOC‐201. Infusion of nitroglycerin (N=2) along with HBOC‐201 diminished arteriolar vasoconstriction, eliminated the rise in MAP, and increased ISF PO 2 (to ~55 mmHg). The findings support the hypothesis that vasoconstriction and elevation in MAP by HBOCs is due to nitric oxide scavenging.