Alicia M. Quesnel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alicia M. Quesnel has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
Michael J. McKenna
Akouos Inc., Boston, Massachusetts
6 shared publicationsDavid H. Jung
From the Department of Radiology (M.P., A.F.J., H.D.C., L.V.R., K.L.R.), Otolaryngology (J.O., D.E.A.-A., A.M.Q., E.D.K., D.H.J.), Massachusetts Eye and Ear, Harvard Medical School, 243 Charles Street, Boston, MA 02114, USA
5 shared publicationsHugh D. Curtin
From the Department of Radiology (M.P., A.F.J., H.D.C., L.V.R., K.L.R.), Otolaryngology (J.O., D.E.A.-A., A.M.Q., E.D.K., D.H.J.), Massachusetts Eye and Ear, Harvard Medical School, 243 Charles Street, Boston, MA 02114, USA
5 shared publicationsDaniel J. Lee
Department of Otolaryngology—Head and Neck Surgery
4 shared publicationsDivya A. Chari
Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, 243 Charles Street, Boston, MA 02114, USA
4 shared publicationsJenny X. Chen
Department of Otolaryngology, Harvard Medical School
4 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 11 (6)
Otopathology of Incomplete Partition Type III : Implications for Cochlear Implantation
- 17 November 2026
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 11 (6)
Open AccessOtopathology of Incomplete Partition Type III : Implications for Cochlear Implantation
- Open Access
- 1 September 2026
- Published by Wiley in The Laryngoscope
Impact of Intraoperative Patient‐Specific 3D ‐Printed Temporal Bones: A Randomized Controlled Trial
Objective: To determine if intraoperative inspection of patient‐specific 3D‐printed TB models, as a supplement to standard imaging, affects the cognitive load of surgeons during cochlear implantation (CI). Methods: This randomized controlled trial included 40 consecutive adult primary CI surgeries performed by seven attending and five trainee surgeons at a large CI center. Cases were randomized 1:1 to current standard with surgical planning based on imaging review (controls) or to current standard plus intra‐operative inspection of a 3D‐printed model (intervention). The primary outcome, intraoperative cognitive load, was measured using the Surgery Task Load Index (Surg‐TLX) and analyzed with linear mixed‐effects models. Secondary outcomes included ratings of model anatomy, utility, and user experience (Schlegel‐questionnaire) and prediction of intraoperative challenges. Results: Attending surgeons experienced lower overall cognitive load using 3D models versus controls (3.8 vs. 5.5; p < 0.01), driven by reduced physical fatigue ( p = 0.01). Conversely, residents reported higher overall load (7.2 vs. 4.8; p = 0.02) with increased mental ( p = 0.01) and physical fatigue ( p < 0.001). Fellows showed no significant difference in overall load (8.2 vs. 8.0; p = 0.88) but noted lower case complexity ( p = 0.02) offset by higher physical fatigue ( p = 0.04). Models were viewed as accurate and useful, particularly for trainee education, anticipating case difficulty and anatomical boundaries. Conclusion: The clinical impact of intraoperative 3D‐printed models during CI is modulated by surgical experience. For attendings, models act as high‐fidelity references facilitating cognitive offloading, whereas they stimulate mental effort for trainees. Selective implementation is recommended to align use of models to surgical experience level to promote operative efficiency and surgical training. Level of Evidence: Level II.
- 1 September 2026
- Published by Wiley in The Laryngoscope
Open AccessImpact of Intraoperative Patient‐Specific 3D ‐Printed Temporal Bones: A Randomized Controlled Trial
Objective: To determine if intraoperative inspection of patient‐specific 3D‐printed TB models, as a supplement to standard imaging, affects the cognitive load of surgeons during cochlear implantation (CI). Methods: This randomized controlled trial included 40 consecutive adult primary CI surgeries performed by seven attending and five trainee surgeons at a large CI center. Cases were randomized 1:1 to current standard with surgical planning based on imaging review (controls) or to current standard plus intra‐operative inspection of a 3D‐printed model (intervention). The primary outcome, intraoperative cognitive load, was measured using the Surgery Task Load Index (Surg‐TLX) and analyzed with linear mixed‐effects models. Secondary outcomes included ratings of model anatomy, utility, and user experience (Schlegel‐questionnaire) and prediction of intraoperative challenges. Results: Attending surgeons experienced lower overall cognitive load using 3D models versus controls (3.8 vs. 5.5; p < 0.01), driven by reduced physical fatigue ( p = 0.01). Conversely, residents reported higher overall load (7.2 vs. 4.8; p = 0.02) with increased mental ( p = 0.01) and physical fatigue ( p < 0.001). Fellows showed no significant difference in overall load (8.2 vs. 8.0; p = 0.88) but noted lower case complexity ( p = 0.02) offset by higher physical fatigue ( p = 0.04). Models were viewed as accurate and useful, particularly for trainee education, anticipating case difficulty and anatomical boundaries. Conclusion: The clinical impact of intraoperative 3D‐printed models during CI is modulated by surgical experience. For attendings, models act as high‐fidelity references facilitating cognitive offloading, whereas they stimulate mental effort for trainees. Selective implementation is recommended to align use of models to surgical experience level to promote operative efficiency and surgical training. Level of Evidence: Level II.
- 27 July 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 47 (9) , 1174-1182
Three-Dimensional Histopathologic Correlates of Cochlear Hypoplasia Type II Versus Incomplete Partition Type II
Hypothesis: Cochlear hypoplasia type-II (CH-II) and incomplete partition type-II (IP-II) may display measurable differences in modiolar: cochlear area ratios and interscalar ridge angles correlating with spiral ganglion neuron (SGN) counts. Background: Inner ear malformations (IEM) can cause variable sensorineural hearing loss and cochlear implant outcomes. CH-II and IP-II share overlapping imaging features. Subtle differences in bony cochlear architecture may underlie distinct SGN patterns. Methods: IP-II (n=11), CH-II (n=5), and normal controls (n=16) were identified from a digitised human temporal bone histologic collection. Radiologically relevant assessments of midmodiolar 2-dimensional (2D) morphology, including interscalar ridge angles and modiolar: cochlear area ratio, were compared with controls. SGNs were quantified. Digital 3-dimensional (3D) reconstructions were created to appreciate the difference in anatomy further. Results: On midmodiolar sections, interscalar septum deficiency, indicating fusion of perilymph-containing scalae, occurred between upper basal and upper middle turns (CH-II, IP-II) and lower middle and apical turns (IP-II only) of the cochlea. Compared with normal cochleae, both CH-II and IP-II cases had a smaller modiolar: cochlear area ratio ( P P <0.01). In CH-II, SGN counts were markedly reduced, ranging from 0% to 20% (mean 8%) of SGN counts in age-matched normally formed cochleae (normal hearing ears); IP-II ranged from 5% to 95% (mean 57%) of age-matched normal cochleae. Conclusions: Given the reduced SGN counts in CH-II compared with normal and IP-II, accurate radiologic subclassification of CH-II versus IP-II is necessary to optimise candidacy selection and counselling for cochlear implantation. A predictive algorithm is suggested based on histologic criteria that might help distinguish between IP-II and CH-II cochleae.
- 27 July 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 47 (9) , 1174-1182
Three-Dimensional Histopathologic Correlates of Cochlear Hypoplasia Type II Versus Incomplete Partition Type II
Hypothesis: Cochlear hypoplasia type-II (CH-II) and incomplete partition type-II (IP-II) may display measurable differences in modiolar: cochlear area ratios and interscalar ridge angles correlating with spiral ganglion neuron (SGN) counts. Background: Inner ear malformations (IEM) can cause variable sensorineural hearing loss and cochlear implant outcomes. CH-II and IP-II share overlapping imaging features. Subtle differences in bony cochlear architecture may underlie distinct SGN patterns. Methods: IP-II (n=11), CH-II (n=5), and normal controls (n=16) were identified from a digitised human temporal bone histologic collection. Radiologically relevant assessments of midmodiolar 2-dimensional (2D) morphology, including interscalar ridge angles and modiolar: cochlear area ratio, were compared with controls. SGNs were quantified. Digital 3-dimensional (3D) reconstructions were created to appreciate the difference in anatomy further. Results: On midmodiolar sections, interscalar septum deficiency, indicating fusion of perilymph-containing scalae, occurred between upper basal and upper middle turns (CH-II, IP-II) and lower middle and apical turns (IP-II only) of the cochlea. Compared with normal cochleae, both CH-II and IP-II cases had a smaller modiolar: cochlear area ratio ( P P <0.01). In CH-II, SGN counts were markedly reduced, ranging from 0% to 20% (mean 8%) of SGN counts in age-matched normally formed cochleae (normal hearing ears); IP-II ranged from 5% to 95% (mean 57%) of age-matched normal cochleae. Conclusions: Given the reduced SGN counts in CH-II compared with normal and IP-II, accurate radiologic subclassification of CH-II versus IP-II is necessary to optimise candidacy selection and counselling for cochlear implantation. A predictive algorithm is suggested based on histologic criteria that might help distinguish between IP-II and CH-II cochleae.
- Open Access
- 22 July 2026
- Published by Springer Nature
- p. 321-336
Inner Ear Pathology for the Cochlear Implant Surgeon
Cochlear implantation (CI) is a well-established and successful hearing rehabilitation strategy for patients with sensorineural hearing loss (SNHL) and limited benefit from amplification alone. Human temporal bone pathology is an excellent source of information on the micro-anatomy relevant to cochlear implant surgery, the acute trauma patterns caused by cochlear implantation, and the long-term biological responses to a CI. The relationship of Rosenthal’s canal to the cochlear duct, the round window anatomy, and structures just inside the cochlea that are vulnerable to injury upon placement of a CI electrode are discussed. Trauma patterns (i.e., acute injury) are related to the type of insertion, with more fibrosis and osteoneogenesis seen in cochleostomy and extended round window approaches than in round window insertions. Perimodiolar electrode arrays are more commonly associated with osseous spiral lamina fracture, whereas straight electrodes are associated with spiral ligament injury. Long-term sequelae of CI include the nearly universal fibrous tissue and/or bony growth in the cochleae, as well as the foreign body response. Finally, special pathologies relevant to CI surgery, such as the ossified cochlea, otosclerosis, temporal bone fracture, and reimplantation, are described and illustrated.
- 22 July 2026
- Published by Springer Nature
- p. 321-336
Open AccessInner Ear Pathology for the Cochlear Implant Surgeon
Cochlear implantation (CI) is a well-established and successful hearing rehabilitation strategy for patients with sensorineural hearing loss (SNHL) and limited benefit from amplification alone. Human temporal bone pathology is an excellent source of information on the micro-anatomy relevant to cochlear implant surgery, the acute trauma patterns caused by cochlear implantation, and the long-term biological responses to a CI. The relationship of Rosenthal’s canal to the cochlear duct, the round window anatomy, and structures just inside the cochlea that are vulnerable to injury upon placement of a CI electrode are discussed. Trauma patterns (i.e., acute injury) are related to the type of insertion, with more fibrosis and osteoneogenesis seen in cochleostomy and extended round window approaches than in round window insertions. Perimodiolar electrode arrays are more commonly associated with osseous spiral lamina fracture, whereas straight electrodes are associated with spiral ligament injury. Long-term sequelae of CI include the nearly universal fibrous tissue and/or bony growth in the cochleae, as well as the foreign body response. Finally, special pathologies relevant to CI surgery, such as the ossified cochlea, otosclerosis, temporal bone fracture, and reimplantation, are described and illustrated.
- 29 April 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- p. ajnr.A9385
Assessment of Acquired “Sheet-Like” Cholesteatomas on Temporal Bone CT
Primary acquired cholesteatomas (PAC) are typically mass-like rounded opacities beginning in the lateral epitympanum that result in osseous erosion. Uncommon presentations of acquired cholesteatoma have been described in the Otolaryngology literature, including en-plaque or sheet-like appearance. To describe findings of histologically confirmed sheet-like cholesteatoma (SLC) and evaluate the diagnostic performance of two experienced head and neck radiologists for the detection of SLC on temporal bone CT (TBCT). Retrospective review of 13 SLC patients, 16 PAC patients, and 8 patients with no cholesteatoma was performed. All patients underwent TBCT and had surgical and pathologic confirmation of disease presence/absence. Two radiologists (45 and 29 years-experience), blinded to diagnosis and study design, independently evaluated the TBCTs for cholesteatoma using a 5-point Likert scale (1-5; higher scores indicating greater confidence in the presence of cholesteatoma). Diagnostic performance was evaluated with receiver operating characteristic (ROC) analysis, with area under the curve (AUC) calculated for each reader. Sensitivity and specificity were calculated. Inter-reader agreement was measured by Cohen's kappa (κ). SLC did not appear as a discrete, solid mass on CT. 61% (8/13) appeared as plaque-like thickening of the tympanic membrane (all with history of perforation/instrumentation), without obvious osseous erosion. 38% (5/13) showed curvilinear, shell-like lamellated tissue in the middle ear (3/5) or mastoid (2/5). For SLC detection, sensitivity and specificity were 43% and 100% (reader 1), and 53% and 71% (reader 2), respectively. For PAC, sensitivity, specificity were 94% and 100% (reader 1) and 94% and 100% (reader 2), respectively. Mean Likert scores for SLC were 3 (reader 1) and 2.3 (reader 2), with moderate agreement (ć=0.49; 95% CI:0.13-0.86); for PAC, scores were 4.7 and 4.4, with excellent agreement (ć=0.80; 95% CI:0.54-1.00). SLC is an uncommon subtype of cholesteatoma with potentially subtle imaging features, without the typical nodular appearance of a PAC, posing a diagnostic challenge. Radiologists should be aware of this variant and report findings cautiously to support accurate clinical management.
- 29 April 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- p. ajnr.A9385
Assessment of Acquired “Sheet-Like” Cholesteatomas on Temporal Bone CT
Primary acquired cholesteatomas (PAC) are typically mass-like rounded opacities beginning in the lateral epitympanum that result in osseous erosion. Uncommon presentations of acquired cholesteatoma have been described in the Otolaryngology literature, including en-plaque or sheet-like appearance. To describe findings of histologically confirmed sheet-like cholesteatoma (SLC) and evaluate the diagnostic performance of two experienced head and neck radiologists for the detection of SLC on temporal bone CT (TBCT). Retrospective review of 13 SLC patients, 16 PAC patients, and 8 patients with no cholesteatoma was performed. All patients underwent TBCT and had surgical and pathologic confirmation of disease presence/absence. Two radiologists (45 and 29 years-experience), blinded to diagnosis and study design, independently evaluated the TBCTs for cholesteatoma using a 5-point Likert scale (1-5; higher scores indicating greater confidence in the presence of cholesteatoma). Diagnostic performance was evaluated with receiver operating characteristic (ROC) analysis, with area under the curve (AUC) calculated for each reader. Sensitivity and specificity were calculated. Inter-reader agreement was measured by Cohen's kappa (κ). SLC did not appear as a discrete, solid mass on CT. 61% (8/13) appeared as plaque-like thickening of the tympanic membrane (all with history of perforation/instrumentation), without obvious osseous erosion. 38% (5/13) showed curvilinear, shell-like lamellated tissue in the middle ear (3/5) or mastoid (2/5). For SLC detection, sensitivity and specificity were 43% and 100% (reader 1), and 53% and 71% (reader 2), respectively. For PAC, sensitivity, specificity were 94% and 100% (reader 1) and 94% and 100% (reader 2), respectively. Mean Likert scores for SLC were 3 (reader 1) and 2.3 (reader 2), with moderate agreement (ć=0.49; 95% CI:0.13-0.86); for PAC, scores were 4.7 and 4.4, with excellent agreement (ć=0.80; 95% CI:0.54-1.00). SLC is an uncommon subtype of cholesteatoma with potentially subtle imaging features, without the typical nodular appearance of a PAC, posing a diagnostic challenge. Radiologists should be aware of this variant and report findings cautiously to support accurate clinical management.
- 2 February 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 47 (3) , 456-464
Cochlear Implant Insertion Trauma Is Associated With Spiral Ganglion Neuron “Dead Zones” in the Human
Hypothesis significant: Cochlear implant (CI) insertion trauma, as evidenced by fracture of the osseous spiral lamina (OSL), is associated with localized “dead zones” and focal spiral ganglion neuron (SGN) loss. Background: Hearing and structure preservation approaches to CI insertion aim to minimize trauma and preserve residual SGNs. In cases of significant insertion trauma, peripheral axons running through the bony OSL inherently become damaged if the OSL is fractured. The current investigation sought to determine if the relative location of OSL fracture was associated with focal areas of SGN loss. Methods: Five adult ears from the Mass Eye and Ear Otopathology Laboratory were identified with OSL fractures. When available, contralateral ears were also analyzed for comparison. Digitized e-Slides were used to create 3D cochlear reconstructions, and a coordinate system relative to the round window allowed for % distance along Rosenthal canal (RC) assignment of SGNs and OSL fracture locations. Abrupt changes in SGN density, defined as a drop >50% within a 5% segment along RC were used as criteria for a significant and focal SGN loss. Insertion trauma in the form of electrode translocation and spiral ligament (SL) perforation was also characterized. Results: OSL fracture lengths ranged from approximately 72 to 109 degrees about the modiolus, with a median fracture length of 75 degrees. Total SGN counts ranged from 16,810 to 22,260. Abrupt and focal drops of >50% in SGN density occurred in all 5 temporal bones with OSL fracture. In 3 of the cases, there were areas of localized “dead zones” at or immediately adjacent to the OSL fracture site, whereas in the remaining 2 cases, drops were seen in various areas across the cochlea. The case with the longest fracture demonstrated nearly a complete loss of neurons apical to the deepest fracture location. Ears with OSL fractures demonstrate a higher number of “dead zones” than the contralateral ears used for comparison, with median values of 3 and 2, respectively. Cases with an OSL fracture, electrode translocation, and SL perforation demonstrated a notably higher number of “dead zones” (median = 3) as compared with ears with only 1 or 2 CI insertional trauma injuries (median = 2). Conclusion: In temporal bones from CI patients, OSL fractures explain some—but not all—of the abrupt SGN loss observed following traumatic CI insertions. Distinct regions of SGN density observed across the length of these cochlea indicate multifactorial processes likely contribute to relative SGN “dead zones.”
- 2 February 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 47 (3) , 456-464
Cochlear Implant Insertion Trauma Is Associated With Spiral Ganglion Neuron “Dead Zones” in the Human
Hypothesis significant: Cochlear implant (CI) insertion trauma, as evidenced by fracture of the osseous spiral lamina (OSL), is associated with localized “dead zones” and focal spiral ganglion neuron (SGN) loss. Background: Hearing and structure preservation approaches to CI insertion aim to minimize trauma and preserve residual SGNs. In cases of significant insertion trauma, peripheral axons running through the bony OSL inherently become damaged if the OSL is fractured. The current investigation sought to determine if the relative location of OSL fracture was associated with focal areas of SGN loss. Methods: Five adult ears from the Mass Eye and Ear Otopathology Laboratory were identified with OSL fractures. When available, contralateral ears were also analyzed for comparison. Digitized e-Slides were used to create 3D cochlear reconstructions, and a coordinate system relative to the round window allowed for % distance along Rosenthal canal (RC) assignment of SGNs and OSL fracture locations. Abrupt changes in SGN density, defined as a drop >50% within a 5% segment along RC were used as criteria for a significant and focal SGN loss. Insertion trauma in the form of electrode translocation and spiral ligament (SL) perforation was also characterized. Results: OSL fracture lengths ranged from approximately 72 to 109 degrees about the modiolus, with a median fracture length of 75 degrees. Total SGN counts ranged from 16,810 to 22,260. Abrupt and focal drops of >50% in SGN density occurred in all 5 temporal bones with OSL fracture. In 3 of the cases, there were areas of localized “dead zones” at or immediately adjacent to the OSL fracture site, whereas in the remaining 2 cases, drops were seen in various areas across the cochlea. The case with the longest fracture demonstrated nearly a complete loss of neurons apical to the deepest fracture location. Ears with OSL fractures demonstrate a higher number of “dead zones” than the contralateral ears used for comparison, with median values of 3 and 2, respectively. Cases with an OSL fracture, electrode translocation, and SL perforation demonstrated a notably higher number of “dead zones” (median = 3) as compared with ears with only 1 or 2 CI insertional trauma injuries (median = 2). Conclusion: In temporal bones from CI patients, OSL fractures explain some—but not all—of the abrupt SGN loss observed following traumatic CI insertions. Distinct regions of SGN density observed across the length of these cochlea indicate multifactorial processes likely contribute to relative SGN “dead zones.”
- 13 January 2026
- Published by Elsevier in Otolaryngologic Clinics of North America
- Vol. 59 (2) , 341-356
Surgical Approaches to the Ossicular Chain
- 13 January 2026
- Published by Elsevier in Otolaryngologic Clinics of North America
- Vol. 59 (2) , 341-356
Surgical Approaches to the Ossicular Chain
- Open Access
Immunohistopathology of Cochleovestibular Schwannoma in Human Temporal Bone Specimens
The aim of this study was to investigate the pathology of hearing loss caused by cochleo-vestibular schwannoma. Surgical specimens have demonstrated that a tumor may displace normal nerve fibers of the cochlear nerve to one side (pushing pattern) or the neoplastic cells may invade the tumor and grow between normal nerve fibers (infiltrating pattern). The goal was to study the relationship of the tumor to the remaining fibers of the cochlear nerve. Nerve fibers within all 28 tumors showed positive anti-neurofilament (NF) labeling. Axons within tumors were sometimes turned orthogonal to their original plane. Onion bulb formations were observed in tumors giving rise to early Antoni B-like regions of degeneration. Positive anti-myelin protein zero (MPZ) labeling was demonstrated. No clear capsule was found between tumor and nerve. There was a comingling of tumor and nerve fibers either with the nerve of origin or with both the nerve of origin and surrounding internal auditory canal nerves. Iba1+ macrophages were prevalent within cochleovestibular schwannomas. Our results suggest that retro cochlear mechanisms of hearing loss go beyond compression of the eighth cranial nerve, involve both myelin and axon degeneration, and suggest an inflammatory component from the earliest stage of the disease.
Open AccessImmunohistopathology of Cochleovestibular Schwannoma in Human Temporal Bone Specimens
The aim of this study was to investigate the pathology of hearing loss caused by cochleo-vestibular schwannoma. Surgical specimens have demonstrated that a tumor may displace normal nerve fibers of the cochlear nerve to one side (pushing pattern) or the neoplastic cells may invade the tumor and grow between normal nerve fibers (infiltrating pattern). The goal was to study the relationship of the tumor to the remaining fibers of the cochlear nerve. Nerve fibers within all 28 tumors showed positive anti-neurofilament (NF) labeling. Axons within tumors were sometimes turned orthogonal to their original plane. Onion bulb formations were observed in tumors giving rise to early Antoni B-like regions of degeneration. Positive anti-myelin protein zero (MPZ) labeling was demonstrated. No clear capsule was found between tumor and nerve. There was a comingling of tumor and nerve fibers either with the nerve of origin or with both the nerve of origin and surrounding internal auditory canal nerves. Iba1+ macrophages were prevalent within cochleovestibular schwannomas. Our results suggest that retro cochlear mechanisms of hearing loss go beyond compression of the eighth cranial nerve, involve both myelin and axon degeneration, and suggest an inflammatory component from the earliest stage of the disease.
- 17 January 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 45 (3) , 245-255
Intracochlear Trauma and Local Ossification Patterns Differ Between Straight and Precurved Cochlear Implant Electrodes
Hypothesis: Trauma to the osseous spiral lamina (OSL) or spiral ligament (SL) during cochlear implant (CI) insertion segregates with electrode type and induces localized intracochlear ossification and fibrosis. Background: The goal of atraumatic CI insertion is to preserve intracochlear structures, limit reactive intracochlear tissue formation, and preserve residual hearing. Previous qualitative studies hypothesized a localized effect of trauma on intracochlear tissue formation; however, quantitative studies failed to confirm this. Methods: Insertional trauma beyond the immediate insertion site was histologically assessed in 21 human temporal bones with a CI. Three-dimensional reconstructions were generated and virtually resectioned perpendicular to the cochlear spiral at high resolution. The cochlear volume occupied by ossification or fibrosis was determined at the midpoint of the trauma and compared with regions proximal and distal to this point. Results: Seven cases, all implanted with precurved electrodes, showed an OSL fracture beyond the immediate insertion site. Significantly more intracochlear ossification was observed at the midpoint of the OSL fracture, compared with the −26 to −18 degrees proximal and 28 to 56 degrees distal to the center. No such pattern was observed for fibrosis. In the 12 cases with a perforation of the SL (9 straight and 3 precurved electrodes), no localized pattern of ossification or fibrosis was observed around these perforations. Conclusion: OSL fractures were observed exclusively with precurved electrodes in this study and may serve as a nidus for localized intracochlear ossification. Perforation of the SL, in contrast, predominantly occurred with straight electrodes and was not associated with localized ossification.
- 17 January 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 45 (3) , 245-255
Intracochlear Trauma and Local Ossification Patterns Differ Between Straight and Precurved Cochlear Implant Electrodes
Hypothesis: Trauma to the osseous spiral lamina (OSL) or spiral ligament (SL) during cochlear implant (CI) insertion segregates with electrode type and induces localized intracochlear ossification and fibrosis. Background: The goal of atraumatic CI insertion is to preserve intracochlear structures, limit reactive intracochlear tissue formation, and preserve residual hearing. Previous qualitative studies hypothesized a localized effect of trauma on intracochlear tissue formation; however, quantitative studies failed to confirm this. Methods: Insertional trauma beyond the immediate insertion site was histologically assessed in 21 human temporal bones with a CI. Three-dimensional reconstructions were generated and virtually resectioned perpendicular to the cochlear spiral at high resolution. The cochlear volume occupied by ossification or fibrosis was determined at the midpoint of the trauma and compared with regions proximal and distal to this point. Results: Seven cases, all implanted with precurved electrodes, showed an OSL fracture beyond the immediate insertion site. Significantly more intracochlear ossification was observed at the midpoint of the OSL fracture, compared with the −26 to −18 degrees proximal and 28 to 56 degrees distal to the center. No such pattern was observed for fibrosis. In the 12 cases with a perforation of the SL (9 straight and 3 precurved electrodes), no localized pattern of ossification or fibrosis was observed around these perforations. Conclusion: OSL fractures were observed exclusively with precurved electrodes in this study and may serve as a nidus for localized intracochlear ossification. Perforation of the SL, in contrast, predominantly occurred with straight electrodes and was not associated with localized ossification.
- 23 August 2023
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (9) , 881-889
Incomplete Partition Type II Cochlear Malformations: Delineating the Three-Dimensional Structure from Digitized Human Histopathological Specimens
Hypothesis: There are clinically relevant differences in scalae anatomy and spiral ganglion neuron (SGN) quantity between incomplete partition type II (IP-II) and normal cochleae. Background: IP-II is a commonly implanted cochlear malformation. Detailed knowledge of intracochlear three-dimensional (3D) morphology may assist with cochlear implant (CI) electrode selection/design and enable optimization of audiologic programming based on SGN maps. Methods: IP-II (n = 11) human temporal bone histological specimens were identified from the National Institute on Deafness and Other Communication Disorders National Temporal Bone Registry and digitized. The cochlear duct, scalae, and surgically relevant anatomy were reconstructed in 3D. A machine learning algorithm was applied to map the location and number of SGNs. Results: 3D scalae morphology of the basal turn was normal. Scala tympani (ST) remained isolated for 540 degrees before fusing with scala vestibuli. Mean ST volume reduced below 1 mm2 after the first 340 degrees. Scala media was a distinct endolymphatic compartment throughout; mean ± standard deviation cochlear duct length was 28 ± 3 mm. SGNs were reduced compared with age-matched norms (mean, 48%; range, 5–90%). In some cases, SGNs failed to ascend Rosenthal's canal, remaining in an abnormal basalward modiolar location. Two forms of IP-II were seen: type A and type B. A majority (98–100%) of SGNs were located in the basal modiolus in type B IP-II, compared with 76 to 85% in type A. Conclusion: Hallmark features of IP-II cochleae include the following: 1) fusion of the ST and scala vestibuli at a mean of 540 degrees, 2) highly variable and overall reduced SGN quantity compared with normative controls, and 3) abnormal SGN distribution with cell bodies failing to ascend Rosenthal's canal.
- 23 August 2023
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (9) , 881-889
Incomplete Partition Type II Cochlear Malformations: Delineating the Three-Dimensional Structure from Digitized Human Histopathological Specimens
Hypothesis: There are clinically relevant differences in scalae anatomy and spiral ganglion neuron (SGN) quantity between incomplete partition type II (IP-II) and normal cochleae. Background: IP-II is a commonly implanted cochlear malformation. Detailed knowledge of intracochlear three-dimensional (3D) morphology may assist with cochlear implant (CI) electrode selection/design and enable optimization of audiologic programming based on SGN maps. Methods: IP-II (n = 11) human temporal bone histological specimens were identified from the National Institute on Deafness and Other Communication Disorders National Temporal Bone Registry and digitized. The cochlear duct, scalae, and surgically relevant anatomy were reconstructed in 3D. A machine learning algorithm was applied to map the location and number of SGNs. Results: 3D scalae morphology of the basal turn was normal. Scala tympani (ST) remained isolated for 540 degrees before fusing with scala vestibuli. Mean ST volume reduced below 1 mm2 after the first 340 degrees. Scala media was a distinct endolymphatic compartment throughout; mean ± standard deviation cochlear duct length was 28 ± 3 mm. SGNs were reduced compared with age-matched norms (mean, 48%; range, 5–90%). In some cases, SGNs failed to ascend Rosenthal's canal, remaining in an abnormal basalward modiolar location. Two forms of IP-II were seen: type A and type B. A majority (98–100%) of SGNs were located in the basal modiolus in type B IP-II, compared with 76 to 85% in type A. Conclusion: Hallmark features of IP-II cochleae include the following: 1) fusion of the ST and scala vestibuli at a mean of 540 degrees, 2) highly variable and overall reduced SGN quantity compared with normative controls, and 3) abnormal SGN distribution with cell bodies failing to ascend Rosenthal's canal.