Alireza Askarzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alireza Askarzadeh has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Mohammad Ali Alipour
Department of Energy Management and Optimization, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
5 shared publicationsAbolfazl Ghaffari
4 shared publicationsMahdi Gharibi
Department of Energy Management and Optimization, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
3 shared publicationsMeysam Montazeri
Faculty of Electrical and Computer Engineering, Graduate University of Advanced Technology, Kerman, Iran
3 shared publications- Mohammadali Alipour2 shared publications
Roohollah Fadaeinedjad
Department of Electrical and Computer Engineering Graduate University of Advanced Technology Kerman Iran
2 shared publications
Latest Publications
- Open Access
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
An efficient framework for siting, sizing and power factor optimization of photovoltaic and wind distributed generations in the presence of capacitor banks
This paper proposes a new efficient optimization framework for siting, sizing and power factor optimization of photovoltaic (PV) and wind turbine (WT)-based distributed generations (DGs) in the presence of capacitor banks. In the proposed framework, the weighted sum of energy loss and voltage deviation index is defined as the objective function and minimized subject to several technical constraints. To solve the optimization problem, two variants of crow search algorithm (CSA), three variants of exploration-exploitation (E2) and two variants of particle swarm optimization (PSO) are employed and the results are compared. Based on the case study, simulation results demonstrate that differential CSA (CSAd) achieves more accurate and robust results than other investigated methods. In addition to the importance of power factor optimization, it is observed that in the absence of capacitor banks, two WTs (with power factors of 0.81 and 0.85) are allocated to the network and no PV installation is suggested. In the presence of capacitor banks, two WTs with unity power factors and a relatively small PV with a power factor of 0.81 are suggested for installation.
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAn efficient framework for siting, sizing and power factor optimization of photovoltaic and wind distributed generations in the presence of capacitor banks
This paper proposes a new efficient optimization framework for siting, sizing and power factor optimization of photovoltaic (PV) and wind turbine (WT)-based distributed generations (DGs) in the presence of capacitor banks. In the proposed framework, the weighted sum of energy loss and voltage deviation index is defined as the objective function and minimized subject to several technical constraints. To solve the optimization problem, two variants of crow search algorithm (CSA), three variants of exploration-exploitation (E2) and two variants of particle swarm optimization (PSO) are employed and the results are compared. Based on the case study, simulation results demonstrate that differential CSA (CSAd) achieves more accurate and robust results than other investigated methods. In addition to the importance of power factor optimization, it is observed that in the absence of capacitor banks, two WTs (with power factors of 0.81 and 0.85) are allocated to the network and no PV installation is suggested. In the presence of capacitor banks, two WTs with unity power factors and a relatively small PV with a power factor of 0.81 are suggested for installation.
- Open Access
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
A voltage stability-oriented optimization framework for electric vehicle charging station integration in distribution networks
The increasing penetration of electric vehicles (EVs) has made the strategic deployment of electric vehicle charging stations (EVCSs) a critical challenge in distribution network planning. To enhance network performance and operational efficiency, this paper proposes a voltage stability-oriented optimization framework for the optimal integration of EVCSs in distribution systems. The proposed approach formulates the planning problem as an optimization task aimed at minimizing total power losses while improving voltage stability throughout the network. For this goal, a weighted objective function is developed to simultaneously address the objectives, and the resulting optimization problem is solved using differential crow search algorithm (DCSA) and exploration–exploitation (E2) method. Numerical results demonstrate that the proposed framework significantly improves the voltage stability and reduces network power losses, thereby providing an effective decision-making tool for modern distribution network planners. Moreover, a weighted objective function leads to a balanced compromise between energy losses and voltage stability, representing an efficient strategy for integration of EVCSs in distribution networks. Compared to the base network, using a weighted objective function results in a 55.6% reduction in energy losses and a 36.2% improvement in voltage stability index (VSI).
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA voltage stability-oriented optimization framework for electric vehicle charging station integration in distribution networks
The increasing penetration of electric vehicles (EVs) has made the strategic deployment of electric vehicle charging stations (EVCSs) a critical challenge in distribution network planning. To enhance network performance and operational efficiency, this paper proposes a voltage stability-oriented optimization framework for the optimal integration of EVCSs in distribution systems. The proposed approach formulates the planning problem as an optimization task aimed at minimizing total power losses while improving voltage stability throughout the network. For this goal, a weighted objective function is developed to simultaneously address the objectives, and the resulting optimization problem is solved using differential crow search algorithm (DCSA) and exploration–exploitation (E2) method. Numerical results demonstrate that the proposed framework significantly improves the voltage stability and reduces network power losses, thereby providing an effective decision-making tool for modern distribution network planners. Moreover, a weighted objective function leads to a balanced compromise between energy losses and voltage stability, representing an efficient strategy for integration of EVCSs in distribution networks. Compared to the base network, using a weighted objective function results in a 55.6% reduction in energy losses and a 36.2% improvement in voltage stability index (VSI).
- Open Access
- 2 March 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
A robust and stochastic operational framework for a grid-connected biomass/photovoltaic hybrid system with battery storage using exploration-exploitation approach
- 2 March 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
Open AccessA robust and stochastic operational framework for a grid-connected biomass/photovoltaic hybrid system with battery storage using exploration-exploitation approach
- Open Access
- 30 January 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
A multi-objective stochastic framework for optimal operation of a hybrid energy system considering cost-emission optimization
- 30 January 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
Open AccessA multi-objective stochastic framework for optimal operation of a hybrid energy system considering cost-emission optimization
- 29 September 2025
- Published by Springer Nature in Soft Computing
- p. 1-21
E2: A basic optimization method using exploration-exploitation concept
- 29 September 2025
- Published by Springer Nature in Soft Computing
- p. 1-21
E2: A basic optimization method using exploration-exploitation concept
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Optimum Allocation of Service Transformers in the Presence of Renewable Energy‐Based Distributed Generations Considering Different Load Profiles
Renewable energy resources (RERs)‐based distributed generations (DGs) such as wind turbines (WTs) and photovoltaics (PVs) are being widely used worldwide, and it is important to consider their impact on the distribution network planning (DNP) problems. In a distribution network, there are many service transformers, and it is vital to consider the impact of RERs on the optimum location and capacity determination of these transformers. Since the shapes of load profiles and RERs generation may highly affect the planning results, in this paper, simultaneous planning of service transformers, PVs and WTs is investigated with respect to different load profiles. Due to the complexity of this problem, the crow search algorithm (CSA), particle swarm optimisation (PSO), differential CSA and a novel method which combines CSA and PSO (CSA‐PSO) are applied, and a comparison of the results is performed. To validate the performance of CSA‐PSO, a sensitivity analysis is conducted on the key parameter of the algorithm. Over the case study, it is observed that (1) the shape of the load profile and local RER generation significantly influence the placement and capacity of service transformers, (2) compared to a PV system, due to its lower cost and better correlation with the load profile, aWT system is preferable and is installed in the network, and (3) CSA‐PSO and differential CSA produce better results than the other investigated methods. Furthermore, over the studied load profiles, the average ratio of the installed WT capacity to the total transformers’ capacity is around 28.3%.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessOptimum Allocation of Service Transformers in the Presence of Renewable Energy‐Based Distributed Generations Considering Different Load Profiles
Renewable energy resources (RERs)‐based distributed generations (DGs) such as wind turbines (WTs) and photovoltaics (PVs) are being widely used worldwide, and it is important to consider their impact on the distribution network planning (DNP) problems. In a distribution network, there are many service transformers, and it is vital to consider the impact of RERs on the optimum location and capacity determination of these transformers. Since the shapes of load profiles and RERs generation may highly affect the planning results, in this paper, simultaneous planning of service transformers, PVs and WTs is investigated with respect to different load profiles. Due to the complexity of this problem, the crow search algorithm (CSA), particle swarm optimisation (PSO), differential CSA and a novel method which combines CSA and PSO (CSA‐PSO) are applied, and a comparison of the results is performed. To validate the performance of CSA‐PSO, a sensitivity analysis is conducted on the key parameter of the algorithm. Over the case study, it is observed that (1) the shape of the load profile and local RER generation significantly influence the placement and capacity of service transformers, (2) compared to a PV system, due to its lower cost and better correlation with the load profile, aWT system is preferable and is installed in the network, and (3) CSA‐PSO and differential CSA produce better results than the other investigated methods. Furthermore, over the studied load profiles, the average ratio of the installed WT capacity to the total transformers’ capacity is around 28.3%.
- 19 November 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (5) , 5957-5982
Uncertainty-based optimal planning of service transformers in distribution network considering load profile: risk-averse and risk-taker strategies modelled by information gap decision theory
- 19 November 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (5) , 5957-5982
Uncertainty-based optimal planning of service transformers in distribution network considering load profile: risk-averse and risk-taker strategies modelled by information gap decision theory
- Open Access
- 14 November 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (16) , 4177-4196
A techno‐enviro‐economic multi‐objective framework for optimal sizing of a biomass/diesel generator‐driven hybrid energy system
This article investigates multi‐objective size optimization of a hybrid energy system (HES) composed of biomass, photovoltaic (PV) and diesel generator considering technical, economic and environmental aspects. For this aim, two multi‐objective frameworks (techno‐economic and techno‐enviro‐economic) are developed where in the techno‐economic framework, total net present cost (TNPC) and loss of power supply probability (LPSP) are considered as the conflicting objectives. LPSP value is used as an index to measure the system reliability (by decrease of LPSP value, reliability will increase). In the techno‐enviro‐economic framework, net present cost of CO 2 emission is also included in TNPC value. Furthermore, to determine the impact of biomass and diesel generator fuel costs on the Pareto front, a sensitivity analysis is conducted. Over the case study, simulated results show that in techno‐economic framework, at small values of LPSP, it is cost‐effective to use PV‐diesel rather than PV‐biomass system. In techno‐enviro‐economic framework, though at LPSP = 0, it is cost‐effective to use PV‐diesel system, in other levels of LPSP, it is desired to use PV‐biomass system.
- 14 November 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (16) , 4177-4196
Open AccessA techno‐enviro‐economic multi‐objective framework for optimal sizing of a biomass/diesel generator‐driven hybrid energy system
This article investigates multi‐objective size optimization of a hybrid energy system (HES) composed of biomass, photovoltaic (PV) and diesel generator considering technical, economic and environmental aspects. For this aim, two multi‐objective frameworks (techno‐economic and techno‐enviro‐economic) are developed where in the techno‐economic framework, total net present cost (TNPC) and loss of power supply probability (LPSP) are considered as the conflicting objectives. LPSP value is used as an index to measure the system reliability (by decrease of LPSP value, reliability will increase). In the techno‐enviro‐economic framework, net present cost of CO 2 emission is also included in TNPC value. Furthermore, to determine the impact of biomass and diesel generator fuel costs on the Pareto front, a sensitivity analysis is conducted. Over the case study, simulated results show that in techno‐economic framework, at small values of LPSP, it is cost‐effective to use PV‐diesel rather than PV‐biomass system. In techno‐enviro‐economic framework, though at LPSP = 0, it is cost‐effective to use PV‐diesel system, in other levels of LPSP, it is desired to use PV‐biomass system.
- Open Access
- 18 April 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (9) , 1885-1905
A risk‐averse strategy based on information gap decision theory for optimal placement of service transformers in distribution networks
In distribution networks, among the planning problems, optimal placement of medium voltage to low voltage (MV/LV) transformers is a vital and challenging issue. Electrical load uncertainty is an important factor that affects the result of this planning problem. This paper investigates optimal allocation of service transformers with respect to the load uncertainty modelled by information gap decision theory (IGDT). For this aim, the planning problem is solved in risk‐neutral (RN) and risk‐averse (RA) frameworks. In RN strategy, objective function is defined to minimize the cost of service transformers and low voltage feeders as well as the cost of power losses. On the other hand, in RA strategy, objective function is defined to maximize the radius of the uncertainty in such a way that any deviation of the uncertain parameter results in an objective function value that is not worse than the critical limit. The optimization problem is solved by crow search algorithm (CSA) and particle swarm optimization (PSO) and the results are compared. In mid‐term planning, with respect to the deviation factors of 0.05, 0.1, 0.15, 0.2, 0.25 and 0.3, optimal values of the uncertainty radius are 5.89%, 13.64%, 21.37%, 28.97%, 34.39% and 43.46%, respectively. In long‐term planning, with respect to the deviation factors of 0.05, 0.1, 0.15, 0.2, 0.25 and 0.3, optimal values of the uncertainty radius are 6.92%, 13.33%, 20.39%, 27.03%, 34% and 40.46%, respectively. Moreover, on average, CSA finds more promising results than PSO.
- 18 April 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (9) , 1885-1905
Open AccessA risk‐averse strategy based on information gap decision theory for optimal placement of service transformers in distribution networks
In distribution networks, among the planning problems, optimal placement of medium voltage to low voltage (MV/LV) transformers is a vital and challenging issue. Electrical load uncertainty is an important factor that affects the result of this planning problem. This paper investigates optimal allocation of service transformers with respect to the load uncertainty modelled by information gap decision theory (IGDT). For this aim, the planning problem is solved in risk‐neutral (RN) and risk‐averse (RA) frameworks. In RN strategy, objective function is defined to minimize the cost of service transformers and low voltage feeders as well as the cost of power losses. On the other hand, in RA strategy, objective function is defined to maximize the radius of the uncertainty in such a way that any deviation of the uncertain parameter results in an objective function value that is not worse than the critical limit. The optimization problem is solved by crow search algorithm (CSA) and particle swarm optimization (PSO) and the results are compared. In mid‐term planning, with respect to the deviation factors of 0.05, 0.1, 0.15, 0.2, 0.25 and 0.3, optimal values of the uncertainty radius are 5.89%, 13.64%, 21.37%, 28.97%, 34.39% and 43.46%, respectively. In long‐term planning, with respect to the deviation factors of 0.05, 0.1, 0.15, 0.2, 0.25 and 0.3, optimal values of the uncertainty radius are 6.92%, 13.33%, 20.39%, 27.03%, 34% and 40.46%, respectively. Moreover, on average, CSA finds more promising results than PSO.
- Open Access
- 19 December 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (2) , 153-168
An efficient optimization framework for distribution network planning by simultaneous allocation of photovoltaic distributed generations and transformers
Among the distribution network planning problems, allocation of transformers is one of the most important and challenging ones. On the other hand, owing to the widespread growth of distributed generations (DGs), their inclusion in the planning problems is vital. This paper proposes an efficient optimization framework for simultaneous allocation of photovoltaic (PV) systems and service transformers in the distribution network. For this aim, to improve the network performance, location and size of the transformers and PV units are optimally determined. Due to the difficulty of the planning problem, four variants of crow search algorithm (CSA) including original CSA, differential CSA (CSA d ), directed differential CSA (CSA dd ) and chaotic directed differential CSA (CSA cdd ) are introduced and applied to the planning problem. To evaluate the impact of PV cost on the results, the planning problem is solved considering different PV system costs. Simulation results show that at the price of $1.25/W, installation of PV systems is cost‐effective, so that over the case study, 400 kW PV system was installed. By decreasing the PV price to $1.2/W, the maximum capacity considered for a PV system is installed. Moreover, on average, CSA d produces more accurate and robust results than the other studied algorithms.
- 19 December 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (2) , 153-168
Open AccessAn efficient optimization framework for distribution network planning by simultaneous allocation of photovoltaic distributed generations and transformers
Among the distribution network planning problems, allocation of transformers is one of the most important and challenging ones. On the other hand, owing to the widespread growth of distributed generations (DGs), their inclusion in the planning problems is vital. This paper proposes an efficient optimization framework for simultaneous allocation of photovoltaic (PV) systems and service transformers in the distribution network. For this aim, to improve the network performance, location and size of the transformers and PV units are optimally determined. Due to the difficulty of the planning problem, four variants of crow search algorithm (CSA) including original CSA, differential CSA (CSA d ), directed differential CSA (CSA dd ) and chaotic directed differential CSA (CSA cdd ) are introduced and applied to the planning problem. To evaluate the impact of PV cost on the results, the planning problem is solved considering different PV system costs. Simulation results show that at the price of $1.25/W, installation of PV systems is cost‐effective, so that over the case study, 400 kW PV system was installed. By decreasing the PV price to $1.2/W, the maximum capacity considered for a PV system is installed. Moreover, on average, CSA d produces more accurate and robust results than the other studied algorithms.