Kirk Arndt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kirk Arndt has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
I. Shipsey
17 shared publicationsD. Bortoletto
13 shared publications- Alice Bean
The University of Kansas
9 shared publications R. Plackett
9 shared publications- Steven Worm
Deutsches Elektronen-Synchrotron DESY
9 shared publications A. Affolder
7 shared publications
Latest Publications
- 22 August 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (04) , 1-8
Automatic selection of correlated double sampling timing parameters
The Journal of Astronomical Telescopes, Instruments, and Systems (JATIS) publishes peer-reviewed papers reporting on original research in the development, testing, and application of telescopes, instrumentation, techniques, and systems for ground- and space-based astronomy.
- 22 August 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (04) , 1-8
Automatic selection of correlated double sampling timing parameters
The Journal of Astronomical Telescopes, Instruments, and Systems (JATIS) publishes peer-reviewed papers reporting on original research in the development, testing, and application of telescopes, instrumentation, techniques, and systems for ground- and space-based astronomy.
- 1 April 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 924, 214-218
Charge collection in irradiated HV-CMOS detectors
- 1 April 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 924, 214-218
Charge collection in irradiated HV-CMOS detectors
- Top Cited Papers
- 10 March 2019
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 873 (2) , 111
LSST: From Science Drivers to Reference Design and Anticipated Data Products
We describe here the most ambitious survey currently planned in the optical, the Large Synoptic Survey Telescope (LSST). The LSST design is driven by four main science themes: probing dark energy and dark matter, taking an inventory of the solar system, exploring the transient optical sky, and mapping the Milky Way. LSST will be a large, wide-field ground-based system designed to obtain repeated images covering the sky visible from Cerro Pachón in northern Chile. The telescope will have an 8.4 m (6.5 m effective) primary mirror, a 9.6 deg2 field of view, a 3.2-gigapixel camera, and six filters (ugrizy) covering the wavelength range 320–1050 nm. The project is in the construction phase and will begin regular survey operations by 2022. About 90% of the observing time will be devoted to a deep-wide-fast survey mode that will uniformly observe a 18,000 deg2 region about 800 times (summed over all six bands) during the anticipated 10 yr of operations and will yield a co-added map to r ∼ 27.5. These data will result in databases including about 32 trillion observations of 20 billion galaxies and a similar number of stars, and they will serve the majority of the primary science programs. The remaining 10% of the observing time will be allocated to special projects such as Very Deep and Very Fast time domain surveys, whose details are currently under discussion. We illustrate how the LSST science drivers led to these choices of system parameters, and we describe the expected data products and their characteristics.
- 10 March 2019
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 873 (2) , 111
Top Cited PapersLSST: From Science Drivers to Reference Design and Anticipated Data Products
We describe here the most ambitious survey currently planned in the optical, the Large Synoptic Survey Telescope (LSST). The LSST design is driven by four main science themes: probing dark energy and dark matter, taking an inventory of the solar system, exploring the transient optical sky, and mapping the Milky Way. LSST will be a large, wide-field ground-based system designed to obtain repeated images covering the sky visible from Cerro Pachón in northern Chile. The telescope will have an 8.4 m (6.5 m effective) primary mirror, a 9.6 deg2 field of view, a 3.2-gigapixel camera, and six filters (ugrizy) covering the wavelength range 320–1050 nm. The project is in the construction phase and will begin regular survey operations by 2022. About 90% of the observing time will be devoted to a deep-wide-fast survey mode that will uniformly observe a 18,000 deg2 region about 800 times (summed over all six bands) during the anticipated 10 yr of operations and will yield a co-added map to r ∼ 27.5. These data will result in databases including about 32 trillion observations of 20 billion galaxies and a similar number of stars, and they will serve the majority of the primary science programs. The remaining 10% of the observing time will be allocated to special projects such as Very Deep and Very Fast time domain surveys, whose details are currently under discussion. We illustrate how the LSST science drivers led to these choices of system parameters, and we describe the expected data products and their characteristics.
- 1 December 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (12) , C12019
An electro-optical test system for optimising operating conditions of CCD sensors for LSST
We describe the commissioning of a system which has been built to investigate optimal operation of CCDs for the LSST telescope. The test system is designed for low vibration, high stability operation and is capable of illuminating a detector in flat-field, projected spot, projected pattern and Fe-55 configurations. We compare and describe some considerations when choosing a gain calibration method for CCDs which exhibit the brighter-fatter effect. An optimisation study on a prototype device of gain and full well with varying back substrate bias and gate clock levels is presented.
- 1 December 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (12) , C12019
An electro-optical test system for optimising operating conditions of CCD sensors for LSST
We describe the commissioning of a system which has been built to investigate optimal operation of CCDs for the LSST telescope. The test system is designed for low vibration, high stability operation and is capable of illuminating a detector in flat-field, projected spot, projected pattern and Fe-55 configurations. We compare and describe some considerations when choosing a gain calibration method for CCDs which exhibit the brighter-fatter effect. An optimisation study on a prototype device of gain and full well with varying back substrate bias and gate clock levels is presented.
- 1 May 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (5) , C05008
Modelling charge storage near full well in CCDs
The shape and size of the stored charge packet within a CCD pixel after exposure has implications for optimal device operation, susceptibility to radiation damage and modelling of dynamic charge collection effects such as the "Brighter-Fatter Effect". Above the full well capacity, phenomena such as bleed trails and surface charge loss occur. In this paper we discuss why accurately reproducing saturation effects in simulations based on electrostatics is difficult, and present an approach to modelling the storage of charge in CCD pixels using commercial semiconductor simulation software. We suggest experimental measurements which can be connected to such modelling. Full well measurements on a thick, high resistivity back illuminated sensor (the e2v CCD261) are presented.
- 1 May 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (5) , C05008
Modelling charge storage near full well in CCDs
The shape and size of the stored charge packet within a CCD pixel after exposure has implications for optimal device operation, susceptibility to radiation damage and modelling of dynamic charge collection effects such as the "Brighter-Fatter Effect". Above the full well capacity, phenomena such as bleed trails and surface charge loss occur. In this paper we discuss why accurately reproducing saturation effects in simulations based on electrostatics is difficult, and present an approach to modelling the storage of charge in CCD pixels using commercial semiconductor simulation software. We suggest experimental measurements which can be connected to such modelling. Full well measurements on a thick, high resistivity back illuminated sensor (the e2v CCD261) are presented.
- Open Access
- 1 February 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (02) , P02010
Radiation hardness studies of AMS HV-CMOS 350 nm prototype chip HVStripV1
Design and standalone characterisation of a capacitively coupled HV-CMOS sensor chip for the CLIC vertex detector I. Kremastiotis, R. Ballabriga, M. Campbell et al.-First tests of a novel radiation hard CMOS sensor process for Depleted Monolithic Active Pixel Sensors H. Pernegger, R. Bates, C. Buttar et al.
- 1 February 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (02) , P02010
Open AccessRadiation hardness studies of AMS HV-CMOS 350 nm prototype chip HVStripV1
Design and standalone characterisation of a capacitively coupled HV-CMOS sensor chip for the CLIC vertex detector I. Kremastiotis, R. Ballabriga, M. Campbell et al.-First tests of a novel radiation hard CMOS sensor process for Depleted Monolithic Active Pixel Sensors H. Pernegger, R. Bates, C. Buttar et al.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
The CHESS-2 prototype in AMS 0.35 μm process: A high voltage CMOS monolithic sensor for ATLAS upgrade
CHESS-2 (CMOS HV Evaluation for Strip Sensors) is a novel ASIC strip architecture designed to investigate the feasibility of using HV-CMOS MAPS (Monolithic Active Pixel Sensors) as alternative sensors for the ATLAS Phase-II Strip Tracker Upgrade. The ASIC is optimized for signal processing, hit pixel position encoding and readout. CHESS-2 includes three independent groups of 128 strips composed of 32 pixels each. The pixel includes a charge sensitive amplifier and the first stage of a comparator inside the collecting well. The second stage, the configuration, the encoding and the readout sections are placed at the periphery of the strips. A novel “fast skip” hit encoding logic identifies the first 8 hit pixel positions with a single-bunch time resolution (25 ns) and sends the data to a fast readout circuitry for serialization and transmission on 14 LVDS channels at 320 MHz. Several substrate resistivity variants have been fabricated for a full characterization of the performance aspects.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
The CHESS-2 prototype in AMS 0.35 μm process: A high voltage CMOS monolithic sensor for ATLAS upgrade
CHESS-2 (CMOS HV Evaluation for Strip Sensors) is a novel ASIC strip architecture designed to investigate the feasibility of using HV-CMOS MAPS (Monolithic Active Pixel Sensors) as alternative sensors for the ATLAS Phase-II Strip Tracker Upgrade. The ASIC is optimized for signal processing, hit pixel position encoding and readout. CHESS-2 includes three independent groups of 128 strips composed of 32 pixels each. The pixel includes a charge sensitive amplifier and the first stage of a comparator inside the collecting well. The second stage, the configuration, the encoding and the readout sections are placed at the periphery of the strips. A novel “fast skip” hit encoding logic identifies the first 8 hit pixel positions with a single-bunch time resolution (25 ns) and sends the data to a fast readout circuitry for serialization and transmission on 14 LVDS channels at 320 MHz. Several substrate resistivity variants have been fabricated for a full characterization of the performance aspects.