XLXin Liu

Xin Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xin Liu has a total of 144 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deep‐Learning‐Enhanced Bioimaging Via Energy Traps Regulated Lanthanide Nanoparticles

    by Renrui Sun, Mengyang Lu, Zhihua Wang, Wen Gao, Jiabo Chen, Xin Liu, Hongxin Zhang, Artur Bednarkiewicz, Fan Zhang, Lining Sun

    High‐resolution biological imaging in deep tissues holds substantial importance for advancing precision medicine. Currently, the lanthanide‐doped nanoparticles enable in vivo near‐infrared imaging but face a critical trade‐off: Er 3 + ‐based emission at around 1530 nm enables high optical resolution yet suffers from limited tissue penetration due to water absorption, whereas nanoprobes emitting at approximately 980/1060 nm offer deeper penetration with high brightness but compromised resolution due to higher tissue scattering at shorter wavelength. This fundamental contradiction between imaging depth and resolution remains a key challenge. Herein, we introduce the concept of energy traps to actively regulate energy distribution within lanthanide nanoparticles via excitation‐wavelength switching and directional energy transfer modulation. This strategy enables controlled access to either sensitizers (Yb 3+ , Nd 3+ ) self‐emission or efficient sensitization of activators (Er 3+ ), thereby allowing selective enhancement of emission channels. By integrating the deep‐tissue penetration capability of short‐wavelength sensitizers (980 and 1060 nm) with the high‐resolution emission of long‐wavelength activators (1530 nm) through a deep‐learning‐based network, we successfully achieved a 93% enhancement in imaging performance for short‐wavelength probes, offering a robust and adaptable platform for high‐contrast deep‐tissue bioimaging and future point‐of‐care diagnostics.

  • Deep‐Learning‐Enhanced Bioimaging Via Energy Traps Regulated Lanthanide Nanoparticles

    by Renrui Sun, Mengyang Lu, Zhihua Wang, Wen Gao, Jiabo Chen, Xin Liu, Hongxin Zhang, Artur Bednarkiewicz, Fan Zhang, Lining Sun

    High‐resolution biological imaging in deep tissues holds substantial importance for advancing precision medicine. Currently, the lanthanide‐doped nanoparticles enable in vivo near‐infrared imaging but face a critical trade‐off: Er 3 + ‐based emission at around 1530 nm enables high optical resolution yet suffers from limited tissue penetration due to water absorption, whereas nanoprobes emitting at approximately 980/1060 nm offer deeper penetration with high brightness but compromised resolution due to higher tissue scattering at shorter wavelength. This fundamental contradiction between imaging depth and resolution remains a key challenge. Herein, we introduce the concept of energy traps to actively regulate energy distribution within lanthanide nanoparticles via excitation‐wavelength switching and directional energy transfer modulation. This strategy enables controlled access to either sensitizers (Yb 3+ , Nd 3+ ) self‐emission or efficient sensitization of activators (Er 3+ ), thereby allowing selective enhancement of emission channels. By integrating the deep‐tissue penetration capability of short‐wavelength sensitizers (980 and 1060 nm) with the high‐resolution emission of long‐wavelength activators (1530 nm) through a deep‐learning‐based network, we successfully achieved a 93% enhancement in imaging performance for short‐wavelength probes, offering a robust and adaptable platform for high‐contrast deep‐tissue bioimaging and future point‐of‐care diagnostics.


  • Open Access

    Noninvasive whole-brain imaging of glymphatic dynamics

    by Nanchao Wang, Xinyuan Yu, Matthew Lowerison, Qinzhe Li, Aidan J. Canning, Peibang He, Lihong Dang, Simone Degan, Brian Mace, Yirui Xu, et al.

    Cerebrospinal fluid circulation through the glymphatic system plays a crucial role in removing metabolic waste from the central nervous system. However, the mechanism underlying the brain-wide glymphatic dynamics is not yet fully understood, in part due to the lack of glymphatic imaging technologies on deep brains. Here, we report a hybrid imaging technology that integrates three-dimensional photoacoustic tomography and ultrasound localization microscopy (3D-PAULM), enhanced by a photoacoustic dye with strong optical absorption in the second near-infrared window (NIR-II). 3D-PAULM allows for continuous, noninvasive, whole-brain imaging in mice through intact skull, providing superresolution mapping of the brain vasculature and highly sensitive tracing of the NIR-II dye in the glymphatic system. Using 3D-PAULM, we investigated the glymphatic function impaired by ischemic stroke, aging, and anesthesia. Our results provide insights into glymphatic transport under various physiological as well as pathological conditions and establish 3D-PAULM as a valuable tool for preclinical glymphatic research.


  • Super-resolution ultrasound imaging in heterogeneous media via multi-focal blind acoustical structured illumination

    by Hao Wang, Junyi Wang, Jingxian Wang, Tiaotiao Zhang, Yufan Li, Xin Liu

    In medical ultrasound imaging, breaking the diffraction limit to achieve super-resolution imaging has long been a research focus. Acoustical structured illumination (ASI) technology projects a pre-defined multi-focus acoustic field to shift high-frequency information into the system's passband, demonstrating the potential for resolution enhancement. However, the reconstruction quality of ASI heavily relies on the precise prior knowledge of the illumination field. In practical clinical applications, especially in heterogeneous tissues, the acoustic velocity inhomogeneity of human tissues can lead to severe wavefront distortion and phase aberrations, disrupting the intended illumination pattern and causing traditional ASI reconstruction to fail with serious image artifacts. To address these challenges of ASI in heterogeneous media, this study proposes a multi-focus blind acoustical structured illumination (B-ASI) imaging method. This approach no longer depends on the precise prior acoustic field information. Instead, it utilizes the statistical characteristics of the illumination patterns and combines them with an iterative optimization framework to blindly compute super-resolved images under conditions of unknown field distortion. Simulation and phantom experiments show that under heterogeneous medium conditions, mismatch between the decoding acoustic field and the actual acoustic field leads to decoding errors in ASI. In contrast to the failure of traditional ASI methods, B-ASI effectively leverages the structural characteristics still present in the actual acoustic field to circumvent decoding failures caused by aberrations, thereby successfully resolving closely spaced point targets. This study provides a practical and effective solution for high-resolution ultrasonic structured acoustic illumination imaging in complex imaging media environments.

  • Open Access

    Differential angular spectrum method for acoustic hologram encryption

    by Jingjing Qin, Qiuchen Zhu, Wenting Gu, Xin Liu

    Ultrasonic holography offers substantial information capacity, yet its potential for information encryption remains largely unexplored with few experimental demonstrations. Here, we present acoustic holographic encryption using a compact single-element transducer. To simultaneously achieve high reconstruction fidelity and amplitude control under simplified hardware, we introduce a physics-informed, differentiation-enhanced computational framework—the Differential Angular Spectrum Algorithm (DASA). DASA augments band-limited angular-spectrum propagation with gradient-based phase optimization and a phase-plate correction, enabling faithful and uniform field synthesis. Reconstruction fidelity is validated by pressure-field measurements and microparticle manipulation, demonstrating practical field-based data encoding and decryption. DASA attains a mean-squared error of 1.5×10−4, peak signal-to-noise ratio of 38.323 dB, uniformity (U) of 0.995, and correlation of 0.995, all computed on [0, 1]-normalized intensity maps within the target region of interest, outperforming the iterative angular spectrum algorithm across these metrics. The approach provides a robust and scalable route to secure, high-density information encoding with a single-transducer–single-lens architecture, with implications for acoustic communication, biomedical manipulation, and physical-layer security.

  • Contrast-free super-resolution ultrasound imaging based on two-stage diffusion probabilistic models

    by Boqian Zhou, Gaobo Zhang, Xuan Ren, Wenting Gu, Qiuchen Zhu, Junyi Wang, Xin Liu


  • A CNN-Based Measurement Signals Transformation Method for High-Quality Apodized Plane Wave Ultrasound Imaging

    by Yaoting Yue, Yijun Xu, Huchang Guan, Chen Jiang, Boyi Li, Xin Liu, Dean Ta

    Plane wave (PW) transmission enables ultrahigh-frame-rate imaging by insonifying the entire field of view with a full-array excitation. However, because PW transmission lacks transmit focusing, the echo signals suffer from low signal-to-noise ratio, which in turn degrades the overall image quality. In contrast, synthetic transmit aperture (STA) imaging uses single-element transmission, which reduces interference and noise in the measured echoes. Combined with full-aperture reception and dynamic focusing during image reconstruction, STA enables high-quality imaging. However, STA requires as many sequential transmissions as the number of probe elements, resulting in a significantly reduced frame rate due to the prolonged acquisition time. In this context, we propose designing a convolutional neural network (CNN) to map the apodized PW measurement signals to their STA-equivalent counterparts, aiming to preserve the high frame rate of PW imaging while achieving image quality comparable to that of STA. Specifically, based on the superposition principle of linear acoustics, we first establish a mathematical measurement relationship between PW and STA signals. This theoretical model then guides the design of a CNN for measurement signal transformation. Finally, high-resolution B-mode ultrasound images are reconstructed using the delay-and-sum beamforming algorithm. We trained the network via self-supervised learning on a simulated dataset generated by Field II and assessed its performance through both in-vitro and in-vivo experiments. The results demonstrate the feasibility and effectiveness of using a CNN to generate STA measurement signals from apodized PW measurement signals, thereby advancing ultrasound imaging by combining high frame rates with improved image quality. Notably, the proposed method exhibits excellent performance in both lateral and axial (longitudinal) resolution. Overall, this study presents a promising approach for achieving high spatiotemporal resolution in ultrasound imaging based on apodized PW acquisition.

  • Open Access

    Multi-wavelength graph convolutional network for high-performance sparse multispectral optoacoustic tomography

    by Mengyang Lu, Jingxian Wang, Jiayuan Peng, Boyi Li, Xin Liu