Charles A. Lissandrello
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Charles A. Lissandrello has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Peter Hsi
Bioengineering Division The Charles Stark Draper Laboratory, Inc. Cambridge MA 02139 USA
3 shared publications- Vishal Tandon
Department of Biomedical Engineering, Cornell University, Ithaca, NY 14853, USA
3 shared publications Alice E. White
Department of Mechanical Engineering, Boston University, 110 Cummington Mall, Boston, MA, 02215, USA
2 shared publicationsAlket Mertiri
Boston University
2 shared publicationsErnest S. Kim
Bioengineering Division The Charles Stark Draper Laboratory, Inc. Cambridge MA 02139 USA
2 shared publications- Jason Fiering
Charles Stark Draper Laboratory, Cambridge, MA, USA
2 shared publications
Latest Publications
- 4 May 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (17)
High‐Throughput CRISPR/Cas9 Mediated Gene Editing of Primary Human T Cells in a Microfluidic Device for Cellular Therapy Manufacturing
Autologous cellular therapies have been highly successful in treating hematological cancers and have the potential to be used for a variety of indications. Manufacturing these therapies rapidly and at low cost remains a major challenge. A key bottleneck in cellular therapy manufacturing is genetic modification of target cells, which is often done using viral vectors. Because vectors are expensive to develop and produce, non‐viral gene transfer using electroporation is emerging as a preferred transfection method for next‐generation therapies. However, most commercial electroporation systems are built for research use rather than large‐scale clinical manufacturing. The microfluidic, continuous‐flow electroporation device presented here offers several advantages including large‐scale and high throughput processing, high performance, and the potential for automation. It transfects primary human T cells with Cas9‐guide ribonucleic acid (RNA) ribonucleoprotein complexes (RNP) and messenger RNA (mRNA) with up to 99–100% efficiency and minimal impact on viability. In addition, this device transfects 3.5 kbp plasmid deoxyribonucleic acid with up to 86% efficiency after preliminary optimization studies. A single microchannel can deliver a total cellular processing throughput of up to 9.6 billion per hour. The combination of high throughput and high performance enables the scale of processing required for future “off‐the‐shelf” allogeneic cellular therapies.
- 4 May 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (17)
High‐Throughput CRISPR/Cas9 Mediated Gene Editing of Primary Human T Cells in a Microfluidic Device for Cellular Therapy Manufacturing
Autologous cellular therapies have been highly successful in treating hematological cancers and have the potential to be used for a variety of indications. Manufacturing these therapies rapidly and at low cost remains a major challenge. A key bottleneck in cellular therapy manufacturing is genetic modification of target cells, which is often done using viral vectors. Because vectors are expensive to develop and produce, non‐viral gene transfer using electroporation is emerging as a preferred transfection method for next‐generation therapies. However, most commercial electroporation systems are built for research use rather than large‐scale clinical manufacturing. The microfluidic, continuous‐flow electroporation device presented here offers several advantages including large‐scale and high throughput processing, high performance, and the potential for automation. It transfects primary human T cells with Cas9‐guide ribonucleic acid (RNA) ribonucleoprotein complexes (RNP) and messenger RNA (mRNA) with up to 99–100% efficiency and minimal impact on viability. In addition, this device transfects 3.5 kbp plasmid deoxyribonucleic acid with up to 86% efficiency after preliminary optimization studies. A single microchannel can deliver a total cellular processing throughput of up to 9.6 billion per hour. The combination of high throughput and high performance enables the scale of processing required for future “off‐the‐shelf” allogeneic cellular therapies.
- 1 July 2022
- Published by Elsevier in Electrochimica Acta
- Vol. 426
Real-time, dynamic monitoring of selectively driven ion-concentration polarization
- 1 July 2022
- Published by Elsevier in Electrochimica Acta
- Vol. 426
Real-time, dynamic monitoring of selectively driven ion-concentration polarization
- Open Access
- 2 June 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (23)
Electrochemical modulation enhances the selectivity of peripheral neurostimulation in vivo
Significance: Bioelectronic medicine relies on electrical stimulation for most applications in the peripheral nervous system. It faces persistent challenges in selectively activating bundled nerve fibers. Here, we investigated ion-concentration modulation with ion-selective membranes and whether this modality may enhance the functional selectivity of peripheral nerve stimulation. We designed a multimodal stimulator that could control Ca 2+ concentrations within a focused volume. Acutely implanting it on the sciatic nerve of a rat, we demonstrated that Ca 2+ depletion could increase the sensitivity of the nerve to electrical stimulation in vivo. We provided evidence that it selectively influenced individual fascicles of the nerve, allowing selective activation by electrical current. Improved functional selectivity may improve outcomes for important therapeutic modalities.
- 2 June 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (23)
Open AccessElectrochemical modulation enhances the selectivity of peripheral neurostimulation in vivo
Significance: Bioelectronic medicine relies on electrical stimulation for most applications in the peripheral nervous system. It faces persistent challenges in selectively activating bundled nerve fibers. Here, we investigated ion-concentration modulation with ion-selective membranes and whether this modality may enhance the functional selectivity of peripheral nerve stimulation. We designed a multimodal stimulator that could control Ca 2+ concentrations within a focused volume. Acutely implanting it on the sciatic nerve of a rat, we demonstrated that Ca 2+ depletion could increase the sensitivity of the nerve to electrical stimulation in vivo. We provided evidence that it selectively influenced individual fascicles of the nerve, allowing selective activation by electrical current. Improved functional selectivity may improve outcomes for important therapeutic modalities.
- Open Access
- 22 October 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-16
High-throughput continuous-flow microfluidic electroporation of mRNA into primary human T cells for applications in cellular therapy manufacturing
Implementation of gene editing technologies such as CRISPR/Cas9 in the manufacture of novel cell-based therapeutics has the potential to enable highly-targeted, stable, and persistent genome modifications without the use of viral vectors. Electroporation has emerged as a preferred method for delivering gene-editing machinery to target cells, but a major challenge remaining is that most commercial electroporation machines are built for research and process development rather than for large-scale, automated cellular therapy manufacturing. Here we present a microfluidic continuous-flow electrotransfection device designed for precise, consistent, and high-throughput genetic modification of target cells in cellular therapy manufacturing applications. We optimized our device for delivery of mRNA into primary human T cells and demonstrated up to 95% transfection efficiency with minimum impact on cell viability and expansion potential. We additionally demonstrated processing of samples comprising up to 500 million T cells at a rate of 20 million cells/min. We anticipate that our device will help to streamline the production of autologous therapies requiring on the order of 10 $$^8$$ –10 $$^9$$ cells, and that it is well-suited to scale for production of trillions of cells to support emerging allogeneic therapies.- 22 October 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-16
Open AccessHigh-throughput continuous-flow microfluidic electroporation of mRNA into primary human T cells for applications in cellular therapy manufacturing
Implementation of gene editing technologies such as CRISPR/Cas9 in the manufacture of novel cell-based therapeutics has the potential to enable highly-targeted, stable, and persistent genome modifications without the use of viral vectors. Electroporation has emerged as a preferred method for delivering gene-editing machinery to target cells, but a major challenge remaining is that most commercial electroporation machines are built for research and process development rather than for large-scale, automated cellular therapy manufacturing. Here we present a microfluidic continuous-flow electrotransfection device designed for precise, consistent, and high-throughput genetic modification of target cells in cellular therapy manufacturing applications. We optimized our device for delivery of mRNA into primary human T cells and demonstrated up to 95% transfection efficiency with minimum impact on cell viability and expansion potential. We additionally demonstrated processing of samples comprising up to 500 million T cells at a rate of 20 million cells/min. We anticipate that our device will help to streamline the production of autologous therapies requiring on the order of 10 $$^8$$ –10 $$^9$$ cells, and that it is well-suited to scale for production of trillions of cells to support emerging allogeneic therapies. - Top Cited Papers
- 2 October 2019
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 116 (42) , 20856-20862
Shape-shifting structured lattices via multimaterial 4D printing
Shape-morphing structured materials have the ability to transform a range of applications. However, their design and fabrication remain challenging due to the difficulty of controlling the underlying metric tensor in space and time. Here, we exploit a combination of multiple materials, geometry, and 4-dimensional (4D) printing to create structured heterogeneous lattices that overcome this problem. Our printable inks are composed of elastomeric matrices with tunable cross-link density and anisotropic filler that enable precise control of their elastic modulus ( E ) and coefficient of thermal expansion ( α ) . The inks are printed in the form of lattices with curved bilayer ribs whose geometry is individually programmed to achieve local control over the metric tensor. For independent control of extrinsic curvature, we created multiplexed bilayer ribs composed of 4 materials, which enables us to encode a wide range of 3-dimensional (3D) shape changes in response to temperature. As exemplars, we designed and printed planar lattices that morph into frequency-shifting antennae and a human face, demonstrating functionality and geometric complexity, respectively. Our inverse geometric design and multimaterial 4D printing method can be readily extended to other stimuli-responsive materials and different 2-dimensional (2D) and 3D cell designs to create scalable, reversible, shape-shifting structures with unprecedented complexity.
- 2 October 2019
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 116 (42) , 20856-20862
Top Cited PapersShape-shifting structured lattices via multimaterial 4D printing
Shape-morphing structured materials have the ability to transform a range of applications. However, their design and fabrication remain challenging due to the difficulty of controlling the underlying metric tensor in space and time. Here, we exploit a combination of multiple materials, geometry, and 4-dimensional (4D) printing to create structured heterogeneous lattices that overcome this problem. Our printable inks are composed of elastomeric matrices with tunable cross-link density and anisotropic filler that enable precise control of their elastic modulus ( E ) and coefficient of thermal expansion ( α ) . The inks are printed in the form of lattices with curved bilayer ribs whose geometry is individually programmed to achieve local control over the metric tensor. For independent control of extrinsic curvature, we created multiplexed bilayer ribs composed of 4 materials, which enables us to encode a wide range of 3-dimensional (3D) shape changes in response to temperature. As exemplars, we designed and printed planar lattices that morph into frequency-shifting antennae and a human face, demonstrating functionality and geometric complexity, respectively. Our inverse geometric design and multimaterial 4D printing method can be readily extended to other stimuli-responsive materials and different 2-dimensional (2D) and 3D cell designs to create scalable, reversible, shape-shifting structures with unprecedented complexity.
- 7 August 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (18) , 2978-2992
Acoustophoretic rapid media exchange and continuous-flow electrotransfection of primary human T cells for applications in automated cellular therapy manufacturing
Our novel device acoustophoretically transfers cells from culture media to electroporation media and then electroporates them using integrated electrodes.
- 7 August 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (18) , 2978-2992
Acoustophoretic rapid media exchange and continuous-flow electrotransfection of primary human T cells for applications in automated cellular therapy manufacturing
Our novel device acoustophoretically transfers cells from culture media to electroporation media and then electroporates them using integrated electrodes.
- 1 May 2019
- Published by AIP Publishing in Biomicrofluidics
- Vol. 13 (3) , 034105
Scalable high-throughput acoustophoresis in arrayed plastic microchannels
Microfluidic acoustophoresis is a label-free technique that isolates a purified product from a complex mixture of cells. This technique is well-studied but thus far has lacked the throughput and device manufacturability needed for many medical and industrial uses. Scale-up of acoustofluidic devices can be more challenging than in other microfluidic systems because the channel walls are integral to the resonant behavior and coupling to neighboring channels can inhibit performance. Additionally, the increased device area needed for parallel channels becomes less practical in the silicon or glass materials usually used for acoustofluidic devices. Here, we report an acoustic separator with 12 parallel channels made entirely from polystyrene that achieves blood cell separation at a flow rate greater than 1 ml/min. We discuss the design and optimization of the device and the electrical drive parameters and compare the separation performance using channels of two different designs. To demonstrate the utility of the device, we test its ability to purify lymphocytes from apheresis product, a process that is critical to new immunotherapies used to treat blood cancers. We process a leukapheresis sample with a volume greater than 100 ml in less than 2 h in a single pass without interruption, achieving greater than 90% purity of lymphocytes, without any prepurification steps. These advances suggest that acoustophoresis could in the future aid in cell therapy bioprocessing and that further scale-up is possible.
- 1 May 2019
- Published by AIP Publishing in Biomicrofluidics
- Vol. 13 (3) , 034105
Scalable high-throughput acoustophoresis in arrayed plastic microchannels
Microfluidic acoustophoresis is a label-free technique that isolates a purified product from a complex mixture of cells. This technique is well-studied but thus far has lacked the throughput and device manufacturability needed for many medical and industrial uses. Scale-up of acoustofluidic devices can be more challenging than in other microfluidic systems because the channel walls are integral to the resonant behavior and coupling to neighboring channels can inhibit performance. Additionally, the increased device area needed for parallel channels becomes less practical in the silicon or glass materials usually used for acoustofluidic devices. Here, we report an acoustic separator with 12 parallel channels made entirely from polystyrene that achieves blood cell separation at a flow rate greater than 1 ml/min. We discuss the design and optimization of the device and the electrical drive parameters and compare the separation performance using channels of two different designs. To demonstrate the utility of the device, we test its ability to purify lymphocytes from apheresis product, a process that is critical to new immunotherapies used to treat blood cancers. We process a leukapheresis sample with a volume greater than 100 ml in less than 2 h in a single pass without interruption, achieving greater than 90% purity of lymphocytes, without any prepurification steps. These advances suggest that acoustophoresis could in the future aid in cell therapy bioprocessing and that further scale-up is possible.
Design and Realization of 3D Printed AFM Probes
Atomic force microscope (AFM) probes and AFM imaging by extension are the product of exceptionally refined silicon micromachining, but are also restricted by the limitations of these fabrication techniques. Here, the nanoscale additive manufacturing technique direct laser writing is explored as a method to print monolithic cantilevered probes for AFM. Not only are 3D printed probes found to function effectively for AFM, but they also confer several advantages, most notably the ability to image in intermittent contact mode with a bandwidth approximately ten times larger than analogous silicon probes. In addition, the arbitrary structural control afforded by 3D printing is found to enable programming the modal structure of the probe, a capability that can be useful in the context of resonantly amplifying nonlinear tip–sample interactions. Collectively, these results show that 3D printed probes complement those produced using conventional silicon micromachining and open the door to new imaging techniques.
Design and Realization of 3D Printed AFM Probes
Atomic force microscope (AFM) probes and AFM imaging by extension are the product of exceptionally refined silicon micromachining, but are also restricted by the limitations of these fabrication techniques. Here, the nanoscale additive manufacturing technique direct laser writing is explored as a method to print monolithic cantilevered probes for AFM. Not only are 3D printed probes found to function effectively for AFM, but they also confer several advantages, most notably the ability to image in intermittent contact mode with a bandwidth approximately ten times larger than analogous silicon probes. In addition, the arbitrary structural control afforded by 3D printing is found to enable programming the modal structure of the probe, a capability that can be useful in the context of resonantly amplifying nonlinear tip–sample interactions. Collectively, these results show that 3D printed probes complement those produced using conventional silicon micromachining and open the door to new imaging techniques.
- 8 January 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (1) , 016010
Carbon fiber on polyimide ultra-microelectrodes
Objective . Most preparations for making neural recordings degrade over time and eventually fail due to insertion trauma and reactive tissue response. The magnitudes of these responses are thought to be related to the electrode size (specifically, the cross-sectional area), the relative stiffness of the electrode, and the degree of tissue tolerance for the material. Flexible carbon fiber ultra-microelectrodes have a much smaller cross-section than traditional electrodes and low tissue reactivity, and thus may enable improved longevity of neural recordings in the central and peripheral nervous systems. Only two carbon fiber array designs have been described previously, each with limited channel densities due to limitations of the fabrication processes or interconnect strategies. Here, we describe a method for assembling carbon fiber electrodes on a flexible polyimide substrate that is expected to facilitate the construction of high-density recording and stimulating arrays. Approach . Individual carbon fibers were aligned using an alignment tool that was 3D-printed with sub-micron resolution using direct laser writing. Indium deposition on the carbon fibers, followed by low-temperature microsoldering, provided a robust and reliable method of electrical connection to the polyimide interconnect. Main results . Spontaneous multiunit activity and stimulation-evoked compound responses with SNR >10 and >120, respectively, were recorded from a small (125 µ m) peripheral nerve. We also improved the typically poor charge injection capacity of small diameter carbon fibers by electrodepositing 100 nm-thick iridium oxide films, making the carbon fiber arrays usable for electrical stimulation as well as recording. Significance . Our innovations in fabrication technique pave the way for further miniaturization of carbon fiber ultra-microelectrode arrays. We believe these advances to be key steps to enable a shift from labor intensive, manual assembly to a more automated manufacturing process.
- 8 January 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (1) , 016010
Carbon fiber on polyimide ultra-microelectrodes
Objective . Most preparations for making neural recordings degrade over time and eventually fail due to insertion trauma and reactive tissue response. The magnitudes of these responses are thought to be related to the electrode size (specifically, the cross-sectional area), the relative stiffness of the electrode, and the degree of tissue tolerance for the material. Flexible carbon fiber ultra-microelectrodes have a much smaller cross-section than traditional electrodes and low tissue reactivity, and thus may enable improved longevity of neural recordings in the central and peripheral nervous systems. Only two carbon fiber array designs have been described previously, each with limited channel densities due to limitations of the fabrication processes or interconnect strategies. Here, we describe a method for assembling carbon fiber electrodes on a flexible polyimide substrate that is expected to facilitate the construction of high-density recording and stimulating arrays. Approach . Individual carbon fibers were aligned using an alignment tool that was 3D-printed with sub-micron resolution using direct laser writing. Indium deposition on the carbon fibers, followed by low-temperature microsoldering, provided a robust and reliable method of electrical connection to the polyimide interconnect. Main results . Spontaneous multiunit activity and stimulation-evoked compound responses with SNR >10 and >120, respectively, were recorded from a small (125 µ m) peripheral nerve. We also improved the typically poor charge injection capacity of small diameter carbon fibers by electrodepositing 100 nm-thick iridium oxide films, making the carbon fiber arrays usable for electrical stimulation as well as recording. Significance . Our innovations in fabrication technique pave the way for further miniaturization of carbon fiber ultra-microelectrode arrays. We believe these advances to be key steps to enable a shift from labor intensive, manual assembly to a more automated manufacturing process.
- 3 November 2017
- Published by IOP Publishing in Nanotechnology
- Vol. 28 (47) , 475303
Directed assembly-based printing of homogeneous and hybrid nanorods using dielectrophoresis
Printing nano and microscale three-dimensional (3D) structures using directed assembly of nanoparticles has many potential applications in electronics, photonics and biotechnology. This paper presents a reproducible and scalable 3D dielectrophoresis assembly process for printing homogeneous silica and hybrid silica/gold nanorods from silica and gold nanoparticles. The nanoparticles are assembled into patterned vias under a dielectrophoretic force generated by an alternating current (AC) field, and then completely fused in situ to form nanorods. The assembly process is governed by the applied AC voltage amplitude and frequency, pattern geometry, and assembly time. Here, we find out that complete assembly of nanorods is not possible without applying both dielectrophoresis and electrophoresis. Therefore, a direct current offset voltage is used to add an additional electrophoretic force to the assembly process. The assembly can be precisely controlled to print silica nanorods with diameters from 20–200 nm and spacing from 500 nm to 2 μ m. The assembled nanorods have good uniformity in diameter and height over a millimeter scale. Besides homogeneous silica nanorods, hybrid silica/gold nanorods are also assembled by sequentially assembling silica and gold nanoparticles. The precision of the assembly process is further demonstrated by assembling a single particle on top of each nanorod to demonstrate an additional level of functionalization. The assembled hybrid silica/gold nanorods have potential to be used for metamaterial applications that require nanoscale structures as well as for plasmonic sensors for biosensing applications.
- 3 November 2017
- Published by IOP Publishing in Nanotechnology
- Vol. 28 (47) , 475303
Directed assembly-based printing of homogeneous and hybrid nanorods using dielectrophoresis
Printing nano and microscale three-dimensional (3D) structures using directed assembly of nanoparticles has many potential applications in electronics, photonics and biotechnology. This paper presents a reproducible and scalable 3D dielectrophoresis assembly process for printing homogeneous silica and hybrid silica/gold nanorods from silica and gold nanoparticles. The nanoparticles are assembled into patterned vias under a dielectrophoretic force generated by an alternating current (AC) field, and then completely fused in situ to form nanorods. The assembly process is governed by the applied AC voltage amplitude and frequency, pattern geometry, and assembly time. Here, we find out that complete assembly of nanorods is not possible without applying both dielectrophoresis and electrophoresis. Therefore, a direct current offset voltage is used to add an additional electrophoretic force to the assembly process. The assembly can be precisely controlled to print silica nanorods with diameters from 20–200 nm and spacing from 500 nm to 2 μ m. The assembled nanorods have good uniformity in diameter and height over a millimeter scale. Besides homogeneous silica nanorods, hybrid silica/gold nanorods are also assembled by sequentially assembling silica and gold nanoparticles. The precision of the assembly process is further demonstrated by assembling a single particle on top of each nanorod to demonstrate an additional level of functionalization. The assembled hybrid silica/gold nanorods have potential to be used for metamaterial applications that require nanoscale structures as well as for plasmonic sensors for biosensing applications.