Neven Matasovic
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Neven Matasovic has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Edward Kavazanjian
Arizona State University
12 shared publications - Dimitrios Zekkos
Department of Civil and Environmental Engineering University of California at Berkeley Berkeley CA USA
5 shared publications Mladen Vucetic
Assoc. Prof. of Civ. Engrg., Civ. Engrg. Dept., Univ. of California, Los Angeles, CA 90024‐1593
4 shared publications- Adda Athanasopoulos-Zekkos
Associate Professor, Dept. of Civil and Environmental Engineering, Univ. of California at Berkeley, Berkeley, CA 94720. ORCID:
2 shared publications Jonathan D. Bray
Assistant Professor, Dept. of Civil and Environmental Engineering, Univ. of Michigan, Ann Arbor, MI 48109–2125
2 shared publicationsKenneth H. Stokoe
2 shared publications
Latest Publications
- 17 December 2020
- Published by Taylor & Francis
- p. 441-448
Cyclic direct simple shear testing of OII landfill solid waste
As a part of pre-design activities for landfill closure Cyclic Direct Simple Shear (CyDSS) testing was conducted on reconstituted solid waste specimens from the Operating Industries, Inc. (OII) landfill in southern California. The testing was conducted in an on-site laboratory using a large-diameter (460 mm) CyDSS device. The results of the testing program indicate: (i) the tested solid waste behaves as a hysteretic material under CyDSS conditions; (ii) Masing rules apply for the tested solid waste material; and (iii) significant modulus reduction and an equivalent viscous damping increase occur at cyclic shear strains beyond approximately 0.1 percent.
- 17 December 2020
- Published by Taylor & Francis
- p. 441-448
Cyclic direct simple shear testing of OII landfill solid waste
As a part of pre-design activities for landfill closure Cyclic Direct Simple Shear (CyDSS) testing was conducted on reconstituted solid waste specimens from the Operating Industries, Inc. (OII) landfill in southern California. The testing was conducted in an on-site laboratory using a large-diameter (460 mm) CyDSS device. The results of the testing program indicate: (i) the tested solid waste behaves as a hysteretic material under CyDSS conditions; (ii) Masing rules apply for the tested solid waste material; and (iii) significant modulus reduction and an equivalent viscous damping increase occur at cyclic shear strains beyond approximately 0.1 percent.
- 11 October 2015
- Published by Springer Nature
- p. 3287-3295
Site Response: 1-D Time Domain Analyses
- 1 October 2014
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 65, 303-313
In-situ assessment of the dynamic properties of municipal solid waste at a landfill in texas
- 1 October 2014
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 65, 303-313
In-situ assessment of the dynamic properties of municipal solid waste at a landfill in texas
- 1 June 2014
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 61-62, 40-56
Learning of pore pressure response and dynamic soil behavior from downhole array measurements
- 1 June 2014
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 61-62, 40-56
Learning of pore pressure response and dynamic soil behavior from downhole array measurements
- 30 December 2013
- Published by Springer Nature
- p. 363-385
Performance Based Design for Seismic Design of Geosynthetics-Lined Waste Containment Systems
- 30 December 2013
- Published by Springer Nature
- p. 363-385
Performance Based Design for Seismic Design of Geosynthetics-Lined Waste Containment Systems
- 1 November 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 139 (11) , 1849-1863
11th Peck Lecture: Predesign Geotechnical Investigation for the OII Superfund Site Landfill
The predesign geotechnical investigation for closure of the Operating Industries, Inc. (OII) Superfund site landfill significantly advanced the state of the art for solid waste landfill engineering. Contributions to solid waste landfill engineering from the OII predesign geotechnical investigation include a solid waste classification system, a method for in situ measurement of waste unit weight, an enhanced understanding of the mechanical properties of solid waste, including unit weight, compressibility, shear strength, shear wave velocity, and equivalent linear shear modulus and equivalent viscous damping, and a methodology for seismic stability and deformation analysis of the waste mass. Many of the procedures and waste property relationships developed for the OII predesign geotechnical investigation remain the state of practice today for solid waste landfill engineering.
- 1 November 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 139 (11) , 1849-1863
11th Peck Lecture: Predesign Geotechnical Investigation for the OII Superfund Site Landfill
The predesign geotechnical investigation for closure of the Operating Industries, Inc. (OII) Superfund site landfill significantly advanced the state of the art for solid waste landfill engineering. Contributions to solid waste landfill engineering from the OII predesign geotechnical investigation include a solid waste classification system, a method for in situ measurement of waste unit weight, an enhanced understanding of the mechanical properties of solid waste, including unit weight, compressibility, shear strength, shear wave velocity, and equivalent linear shear modulus and equivalent viscous damping, and a methodology for seismic stability and deformation analysis of the waste mass. Many of the procedures and waste property relationships developed for the OII predesign geotechnical investigation remain the state of practice today for solid waste landfill engineering.
- 9 October 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 471-480
Back Analysis of Landslide Deposit Basal Failure Plane Residual Shear Strength
Landslide deposits are geologic features that show signs of movement ("failure") which occurred outside the historical record. Unlike recent landslides, they do not show evidence of recent movement such as a defined head scarp, tension cracking, and/or bulging at the toe, but are identified by geomorphic evidence of past movement. Back analysis of landslides is a common technique used to assess shear strengths for design wherein a factor of safety (FS) equal to 1.0 is assumed along a pre-defined failure surface. However, as landslide deposits may no longer be "at the verge" of failure, a back analysis with an assumed FS equal to 1.0 may result in excessively conservative shear strength properties. Therefore, back analysis of landslide deposits should be performed assuming a FS greater than 1.0. As there is no consensus on how much higher than unity FS should be, values typically used in practice range between FS = 1.05 and 1.25 with little, if any, justification provided for FS selected. Consensus on seismic FS and/or calculated maximum permanent seismic displacement for use in back analysis is similarly lacking. In this paper we evaluate parameters that affect back analysis of landslide deposits and provide illustration using a recent case history from our practice.
- 9 October 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 471-480
Back Analysis of Landslide Deposit Basal Failure Plane Residual Shear Strength
Landslide deposits are geologic features that show signs of movement ("failure") which occurred outside the historical record. Unlike recent landslides, they do not show evidence of recent movement such as a defined head scarp, tension cracking, and/or bulging at the toe, but are identified by geomorphic evidence of past movement. Back analysis of landslides is a common technique used to assess shear strengths for design wherein a factor of safety (FS) equal to 1.0 is assumed along a pre-defined failure surface. However, as landslide deposits may no longer be "at the verge" of failure, a back analysis with an assumed FS equal to 1.0 may result in excessively conservative shear strength properties. Therefore, back analysis of landslide deposits should be performed assuming a FS greater than 1.0. As there is no consensus on how much higher than unity FS should be, values typically used in practice range between FS = 1.05 and 1.25 with little, if any, justification provided for FS selected. Consensus on seismic FS and/or calculated maximum permanent seismic displacement for use in back analysis is similarly lacking. In this paper we evaluate parameters that affect back analysis of landslide deposits and provide illustration using a recent case history from our practice.
- 1 January 2013
- Published by Springer Nature
- p. 1-10
Site Response: 1-D Time Domain Analyses
- 29 March 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 1789-1798
Site Response Analysis in Transportation Engineering Practice–A TRB Survey
This paper presents the outcome of an on-line survey sponsored by the Transportation Research Board (TRB) of the National Academies (NAS) on the current state of development of tools, techniques, and practices for performing site response analysis. The core participants of the survey were select Departments of Transportation (DOTs) of states affected by seismicity, collectively referred to as the T-3+ states, and engineering firms involved with DOT projects. The processed results of the survey provide an insight into the manner in which site response analyses are currently performed, how material parameters and design ground motions are selected, which site response programs are used in DOT practices, and how results of site response analyses are interpreted in contemporary geotechnical earthquake engineering practice for highway facilities in T-3+ states.
- 29 March 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 1789-1798
Site Response Analysis in Transportation Engineering Practice–A TRB Survey
This paper presents the outcome of an on-line survey sponsored by the Transportation Research Board (TRB) of the National Academies (NAS) on the current state of development of tools, techniques, and practices for performing site response analysis. The core participants of the survey were select Departments of Transportation (DOTs) of states affected by seismicity, collectively referred to as the T-3+ states, and engineering firms involved with DOT projects. The processed results of the survey provide an insight into the manner in which site response analyses are currently performed, how material parameters and design ground motions are selected, which site response programs are used in DOT practices, and how results of site response analyses are interpreted in contemporary geotechnical earthquake engineering practice for highway facilities in T-3+ states.
- 11 March 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 1981-1990
Seismic Analysis of a Geosynthetic Liner System
Two-dimensional (2-D) non-linear time-domain analyses of the tensile forces and strains induced in the geosynthetic liner system of a solid waste landfill by seismic loading were conducted using a model that allows for relative displacement (slip) at the interfaces of the liner system. The analyses suggest that tensile strains and forces induced in the liner system by seismic loading will be within allowable values if the difference in interface friction angle between the top and bottom of the liner is relatively small. While the deformation at the crest of the side slope from the non-linear analyses were similar to the deformations calculated in a conventional 1-D decoupled analysis, the deformations at the toe of a canyon-type landfill calculated in the 2-D non-linear analysis was significantly greater than calculated in the 1-D decoupled analysis. The analyses reported herein were for two simplified landfill geometries and only employed one earthquake time history and one set of interface strengths. Additional analyses are required to determine if these results are representative of landfill response or are an artifact of the landfill geometry, interface strengths, and time history used in these analyses.
- 11 March 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 1981-1990
Seismic Analysis of a Geosynthetic Liner System
Two-dimensional (2-D) non-linear time-domain analyses of the tensile forces and strains induced in the geosynthetic liner system of a solid waste landfill by seismic loading were conducted using a model that allows for relative displacement (slip) at the interfaces of the liner system. The analyses suggest that tensile strains and forces induced in the liner system by seismic loading will be within allowable values if the difference in interface friction angle between the top and bottom of the liner is relatively small. While the deformation at the crest of the side slope from the non-linear analyses were similar to the deformations calculated in a conventional 1-D decoupled analysis, the deformations at the toe of a canyon-type landfill calculated in the 2-D non-linear analysis was significantly greater than calculated in the 1-D decoupled analysis. The analyses reported herein were for two simplified landfill geometries and only employed one earthquake time history and one set of interface strengths. Additional analyses are required to determine if these results are representative of landfill response or are an artifact of the landfill geometry, interface strengths, and time history used in these analyses.