Ilhan Erden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ilhan Erden has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ayşe Erden
Ankara University Faculty of Medicine, Department of Radiology, Ankara, Türkiye
3 shared publications - Diğdem Kuru Öz
Ankara University Faculty of Medicine, Department of Radiology, Ankara, Türkiye
2 shared publications - Elif Peker
Department of Radiology, Faculty of Medicine, Ankara University, Ankara, Türkiye
2 shared publications - Habip Eser Akkaya
Ankara Eğitim ve Araştırma Hastanesi
2 shared publications - Funda Seher Özalp Ateş
Department of Biostatistics and Medical Informatics, Faculty of Medicine, Manisa Celal Bayar University
1 shared publication - Melahat Kul
Department of Radiology, Faculty of Medicine, Ankara University, Ankara 06230, Turkey
1 shared publication
Latest Publications
- 15 January 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (1) , 7-14
MRI quantification techniques in fatty liver: the diagnostic performance of hepatic T1, T2, and stiffness measurements in relation to the proton density fat fraction
Nonalcoholic fatty liver disease (NAFLD) can progress to liver cirrhosis and is predicted to become the most frequent indication for liver transplantation in the near future. Noninvasive assessment of NAFLD is important for diagnosis and patient management. This study aims to prospectively determine the liver stiffness and T1 and T2 values in patients with NAFLD and to compare the diagnostic performance of magnetic resonance elastography (MRE) and mapping techniques in relation to the proton density fat fraction (PDFF). Eighty-three patients with NAFLD and 26 participants with normal livers were imaged with a 1.5 T scanner. PDFF measurements obtained from the multiecho Dixon technique were used to quantify the liver fat. MRE, native T1 mapping (modified Look-Locker inversion recovery [MOLLI] schemes 5(3)3, 3(3)3(3)5, and 3(2)3(2)5 and the B1-corrected variable flip angle [VFA] method), and T2 mapping values were correlated with PDFF. The diagnostic performance of MRE and the mapping techniques were analyzed and compared. T1 values measured with the MOLLI schemes and the B1-corrected VFA (P < 0.001), and the stiffness values from MRE (P = 0.047) were significantly higher in the NAFLD group. No significant difference was found between the groups in terms of T2 values (P = 0.127). In differentiation of the NAFLD and control groups, the B1-corrected VFA technique had slightly higher accuracy and area under the curve (AUC) than the MOLLI schemes. In the NAFLD group, there was a good correlation between the PDFF, MOLLI 3(3)3(3)5 and 3(2)3(2)5, and VFA T1 measurements (r=0.732; r=0.735; r=0.716, P < 0.001, respectively). Liver T1 mapping techniques have the potential to distinguish steatotic from nonsteatotic livers, and T1 values seem to have a strong correlation with the liver fat content.
- 15 January 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (1) , 7-14
MRI quantification techniques in fatty liver: the diagnostic performance of hepatic T1, T2, and stiffness measurements in relation to the proton density fat fraction
Nonalcoholic fatty liver disease (NAFLD) can progress to liver cirrhosis and is predicted to become the most frequent indication for liver transplantation in the near future. Noninvasive assessment of NAFLD is important for diagnosis and patient management. This study aims to prospectively determine the liver stiffness and T1 and T2 values in patients with NAFLD and to compare the diagnostic performance of magnetic resonance elastography (MRE) and mapping techniques in relation to the proton density fat fraction (PDFF). Eighty-three patients with NAFLD and 26 participants with normal livers were imaged with a 1.5 T scanner. PDFF measurements obtained from the multiecho Dixon technique were used to quantify the liver fat. MRE, native T1 mapping (modified Look-Locker inversion recovery [MOLLI] schemes 5(3)3, 3(3)3(3)5, and 3(2)3(2)5 and the B1-corrected variable flip angle [VFA] method), and T2 mapping values were correlated with PDFF. The diagnostic performance of MRE and the mapping techniques were analyzed and compared. T1 values measured with the MOLLI schemes and the B1-corrected VFA (P < 0.001), and the stiffness values from MRE (P = 0.047) were significantly higher in the NAFLD group. No significant difference was found between the groups in terms of T2 values (P = 0.127). In differentiation of the NAFLD and control groups, the B1-corrected VFA technique had slightly higher accuracy and area under the curve (AUC) than the MOLLI schemes. In the NAFLD group, there was a good correlation between the PDFF, MOLLI 3(3)3(3)5 and 3(2)3(2)5, and VFA T1 measurements (r=0.732; r=0.735; r=0.716, P < 0.001, respectively). Liver T1 mapping techniques have the potential to distinguish steatotic from nonsteatotic livers, and T1 values seem to have a strong correlation with the liver fat content.
- Open Access
- 1 January 2019
- Published by AVES YAYINCILIK A.Ş. in The Eurasian Journal of Medicine
- Vol. 51 (1) , 31-37
Diagnostic Performance of Multiparametric MR Imaging at 3.0 Tesla in Discriminating Prostate Cancer from Prostatitis: A Histopathologic Correlation
Objective: To investigate the diagnostic performance of multiparametric magnetic resonance imaging (mpMRI) in differentiating prostate cancer (PCa) from prostatitis foci. Materials and Methods: This retrospective analysis included 81 biopsy-proven lesions (44 prostatitis and 37 PCa). Normalized T2-signal intensity (nT2SI) and SI on diffusion-weighted imaging (b=1000 and 2000 mm2/s), apparent diffusion coefficient (ADC) values, peak SI, SI at the end of the dynamic curves, mean peak time, mean enhancement percentage, and washout percentage obtained from dynamic contrast-enhanced imaging (DCEI) were measured. Results: nT2SI (3.8 vs. 3.2, p=0.003) and ADC values (0.685×10−3 mm2/s vs. 0.874×10−3 mm2/s, p
- 1 January 2019
- Published by AVES YAYINCILIK A.Ş. in The Eurasian Journal of Medicine
- Vol. 51 (1) , 31-37
Open AccessDiagnostic Performance of Multiparametric MR Imaging at 3.0 Tesla in Discriminating Prostate Cancer from Prostatitis: A Histopathologic Correlation
Objective: To investigate the diagnostic performance of multiparametric magnetic resonance imaging (mpMRI) in differentiating prostate cancer (PCa) from prostatitis foci. Materials and Methods: This retrospective analysis included 81 biopsy-proven lesions (44 prostatitis and 37 PCa). Normalized T2-signal intensity (nT2SI) and SI on diffusion-weighted imaging (b=1000 and 2000 mm2/s), apparent diffusion coefficient (ADC) values, peak SI, SI at the end of the dynamic curves, mean peak time, mean enhancement percentage, and washout percentage obtained from dynamic contrast-enhanced imaging (DCEI) were measured. Results: nT2SI (3.8 vs. 3.2, p=0.003) and ADC values (0.685×10−3 mm2/s vs. 0.874×10−3 mm2/s, p
- 6 November 2018
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 24 (6) , 328-335
Magnetic resonance elastography: basic principles, technique, and clinical applications in the liver
Diagnostic and Interventional Radiology
- 6 November 2018
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 24 (6) , 328-335
Magnetic resonance elastography: basic principles, technique, and clinical applications in the liver
Diagnostic and Interventional Radiology