Mary E. Jenkins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mary E. Jenkins has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Ana Luisa Trejos
Western University
6 shared publications - Michael D. Naish
Department of Mechanical and Materials Engineering, ECE, and BME, Western University, London, ON, Canada
6 shared publications - Yue Zhou
School of Biomedical Engineering (BME), Western University, London, ON, Canada
6 shared publications - Zahra Habibollahi
Department of Electrical and Computer Engineering (ECE), Western University, London, ON, Canada
4 shared publications - Andrew M. Johnson
School of Health Studies, The University of Western Ontario
3 shared publications - Jayne Garland
Western University
3 shared publications
Latest Publications
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (22) , 37492-37502
Variability of Parkinsonian Tremor During Different Tasks and Under External Interference
Tremor is one of the earliest signs of Parkinson’s disease (PD) that typically occurs at rest but can also manifest during postural actions or voluntary motion. Several studies have demonstrated that there is great variability in tremor across different body parts, among individuals, and within the same individual across multiple trials. While methods such as functional electrical stimulation have shown promising results for tremor suppression, the use of these methods relies on the ability to predict and estimate the tremor. This study examines four PD tremor characteristics, including magnitude, power spectrum density, frequency, and approximate entropy (ApEn), as measures of regularity. These characteristics are measured under different conditions with and without external interference and voluntary movements. Results show that the tremor frequency changes when voluntary motion is involved or when external disturbances such as functional electrical stimulation (FES) or mechanical loading are used to suppress tremor (p < 0.05). Tremor power and magnitude also change in the presence of voluntary motion (p < 0.05). On the other hand, ApEn is more consistent in the absence of external interference, independent of voluntary movement, but changes when electrical stimulation or mechanical loading is used to suppress tremor (p < 0.05). Gaining a general understanding of tremor variability and changes in tremor characteristics helps enhance wearable tremor suppression devices (WTSD) to address intra-individual tremor fluctuations effectively.
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (22) , 37492-37502
Variability of Parkinsonian Tremor During Different Tasks and Under External Interference
Tremor is one of the earliest signs of Parkinson’s disease (PD) that typically occurs at rest but can also manifest during postural actions or voluntary motion. Several studies have demonstrated that there is great variability in tremor across different body parts, among individuals, and within the same individual across multiple trials. While methods such as functional electrical stimulation have shown promising results for tremor suppression, the use of these methods relies on the ability to predict and estimate the tremor. This study examines four PD tremor characteristics, including magnitude, power spectrum density, frequency, and approximate entropy (ApEn), as measures of regularity. These characteristics are measured under different conditions with and without external interference and voluntary movements. Results show that the tremor frequency changes when voluntary motion is involved or when external disturbances such as functional electrical stimulation (FES) or mechanical loading are used to suppress tremor (p < 0.05). Tremor power and magnitude also change in the presence of voluntary motion (p < 0.05). On the other hand, ApEn is more consistent in the absence of external interference, independent of voluntary movement, but changes when electrical stimulation or mechanical loading is used to suppress tremor (p < 0.05). Gaining a general understanding of tremor variability and changes in tremor characteristics helps enhance wearable tremor suppression devices (WTSD) to address intra-individual tremor fluctuations effectively.
- Open Access
- 2 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 3289-3298
Tremor Suppression Using Functional Electrical Stimulation
Parkinson’s disease (PD) and essential tremor are two major causes of pathological tremor among people over 60 years old. Due to the side effects and complications of traditional tremor management methods such as medication and deep brain surgery, non invasive tremor suppression methods have become more popular in recent years. Functional electrical stimulation (FES) is one of the methods used to reduce tremor in several studies. However, the effect of different FES parameters on tremor suppression and discomfort level, including amplitude, the number of pulses in each stimulation burst, frequency, and pulse width is yet to be studied for longer stimulation durations. Therefore, in this work, experiments were performed on 14 participants with PD to evaluate the effect of thirty seconds of out-of-phase electrical stimulation on wrist tremor at rest. Trials were conducted by varying the stimulation amplitude and the number of pulses while keeping the frequency and pulse width constant. Each test was repeated three times for each participant. The results showed an overall tremor suppression for 11 out of 14 participants and no average positive effects for three participants. It is concluded that despite the effectiveness of FES in tremor suppression, each set of FES parameters showed different suppression levels among participants due to the variability of tremor over time. Thus, for this method to be effective, an adaptive control system would be required to tune FES parameters in real time according to changes in tremor during extended stimulation periods.
- 2 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 3289-3298
Open AccessTremor Suppression Using Functional Electrical Stimulation
Parkinson’s disease (PD) and essential tremor are two major causes of pathological tremor among people over 60 years old. Due to the side effects and complications of traditional tremor management methods such as medication and deep brain surgery, non invasive tremor suppression methods have become more popular in recent years. Functional electrical stimulation (FES) is one of the methods used to reduce tremor in several studies. However, the effect of different FES parameters on tremor suppression and discomfort level, including amplitude, the number of pulses in each stimulation burst, frequency, and pulse width is yet to be studied for longer stimulation durations. Therefore, in this work, experiments were performed on 14 participants with PD to evaluate the effect of thirty seconds of out-of-phase electrical stimulation on wrist tremor at rest. Trials were conducted by varying the stimulation amplitude and the number of pulses while keeping the frequency and pulse width constant. Each test was repeated three times for each participant. The results showed an overall tremor suppression for 11 out of 14 participants and no average positive effects for three participants. It is concluded that despite the effectiveness of FES in tremor suppression, each set of FES parameters showed different suppression levels among participants due to the variability of tremor over time. Thus, for this method to be effective, an adaptive control system would be required to tune FES parameters in real time according to changes in tremor during extended stimulation periods.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (2) , 643-651
Assessment of a Fault-Tolerant Control-Based Wearable Tremor Suppression Glove Under Faults and Disturbances
Pathological tremor severely impacts the quality of life of affected individuals. The need for tremor management approaches that are free of side effects and surgical complications has sparked research in wearable tremor suppression technology. The existing wearable tremor suppression devices have achieved suppression ratios of up to 90%. Although the achieved performance is promising, the safety of using these devices outside of a lab environment, where faults and disturbances exist, has not been studied. It was recently discovered that existing tremor suppression systems are not effective and safe for users when faults and disturbances are present. Therefore, this study proposes and evaluates a novel fault-tolerant control system for tremor suppression. Using 18 tremor datasets previously recorded, the performance of the proposed system under three simulated common faults was evaluated on a bench-top mechatronic tremor simulator. The assessment showed that the proposed system remained safe and functional after introducing the faults, maintaining at least a 60% tremor suppression rate, and root mean square tracking error lower than 2.7(compared to 80.5without the proposed system). This study improves the robustness and safety of wearable tremor suppression devices, providing strong evidence to facilitate the transition of these devices from the lab to real-life applications.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (2) , 643-651
Assessment of a Fault-Tolerant Control-Based Wearable Tremor Suppression Glove Under Faults and Disturbances
Pathological tremor severely impacts the quality of life of affected individuals. The need for tremor management approaches that are free of side effects and surgical complications has sparked research in wearable tremor suppression technology. The existing wearable tremor suppression devices have achieved suppression ratios of up to 90%. Although the achieved performance is promising, the safety of using these devices outside of a lab environment, where faults and disturbances exist, has not been studied. It was recently discovered that existing tremor suppression systems are not effective and safe for users when faults and disturbances are present. Therefore, this study proposes and evaluates a novel fault-tolerant control system for tremor suppression. Using 18 tremor datasets previously recorded, the performance of the proposed system under three simulated common faults was evaluated on a bench-top mechatronic tremor simulator. The assessment showed that the proposed system remained safe and functional after introducing the faults, maintaining at least a 60% tremor suppression rate, and root mean square tracking error lower than 2.7(compared to 80.5without the proposed system). This study improves the robustness and safety of wearable tremor suppression devices, providing strong evidence to facilitate the transition of these devices from the lab to real-life applications.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (11) , 7543-7550
Multimodal Tremor Suppression of the Wrist Using FES and Electric Motors–A Simulation Study
Wearable technologies have shown promising results in tremor management, making them a feasible alternative to current treatments. Devices based on active actuation, such as electric motors, show high tremor suppression rate, but are heavy and bulky. In contrast, devices based on functional electrical stimulation (FES) are lightweight and smaller in size, but might cause pain, discomfort, and FES-induced muscle fatigue. Also, when the stimulation parameters do not adapt to the tremor, their suppression performance is compromised. Therefore, a multimodal approach was developed and tested by modeling wrist joint dynamics and simulating the muscle response to FES based on an existing dataset collected from 18 participants with Parkinson's disease. The goal was to evaluate and compare the performance of a multimodal device to that of an FES-only or an electric-motor-only approach. A nonlinear control system allocates the control effort between FES and motor torque based on the tremor level. Results showed an improvement in tremor suppression level (up to 12%) in the multimodal approach compared to FES only when there is voluntary motion. Also, the voluntary motion tracking error was lower in the multimodal approach, compared to the FES-only method (up to 57%). No notable improvement in tremor suppression level or voluntary motion tracking error was observed by comparing the multimodal system and the motor only approach. However, the advantage of using a multimodal system compared to the motor-only system is the reduction of the required motor torque resulting in reduced weight and size of the final device.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (11) , 7543-7550
Multimodal Tremor Suppression of the Wrist Using FES and Electric Motors–A Simulation Study
Wearable technologies have shown promising results in tremor management, making them a feasible alternative to current treatments. Devices based on active actuation, such as electric motors, show high tremor suppression rate, but are heavy and bulky. In contrast, devices based on functional electrical stimulation (FES) are lightweight and smaller in size, but might cause pain, discomfort, and FES-induced muscle fatigue. Also, when the stimulation parameters do not adapt to the tremor, their suppression performance is compromised. Therefore, a multimodal approach was developed and tested by modeling wrist joint dynamics and simulating the muscle response to FES based on an existing dataset collected from 18 participants with Parkinson's disease. The goal was to evaluate and compare the performance of a multimodal device to that of an FES-only or an electric-motor-only approach. A nonlinear control system allocates the control effort between FES and motor torque based on the tremor level. Results showed an improvement in tremor suppression level (up to 12%) in the multimodal approach compared to FES only when there is voluntary motion. Also, the voluntary motion tracking error was lower in the multimodal approach, compared to the FES-only method (up to 57%). No notable improvement in tremor suppression level or voluntary motion tracking error was observed by comparing the multimodal system and the motor only approach. However, the advantage of using a multimodal system compared to the motor-only system is the reduction of the required motor torque resulting in reduced weight and size of the final device.
- Open Access
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 2856-2865
Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device
The side effects and complications of traditional treatments for treating pathological tremor have led to a growing research interest in wearable tremor suppression devices (WTSDs) as an alternative approach. Similar to how the human brain coordinates the function of the human system, a tremor estimator determines how a WTSD functions. Although many tremor estimation algorithms have been developed and validated, whether they can be implemented on a cost-effective embedded system has not been studied; furthermore, their effectiveness on tremor signals with multiple harmonics has not been investigated. Therefore, in this study, four tremor estimators were implemented, evaluated, and compared: Weighted-frequency Fourier Linear Combiner (WFLC), WFLC-based Kalman Filter (WFLC-KF), Band-limited Multiple FLC, and enhanced High-order WFLC-KF (eHWFLC-KF). This study aimed to evaluate the performance of each algorithm on a bench-top tremor suppression system with 18 recorded tremor motion datasets; and compare the performance of each estimator. The experimental evaluation showed that the eHWFLC-KF-based WTSD achieved the best performance when suppressing tremor with an average of 89.3% reduction in tremor power, and an average error when tracking voluntary motion of 6.6°/s. Statistical analysis indicated that the eHWFLC-KF-based WTSD is able to reduce the power of tremor better than the WFLC and WFLC-KF, and the BMFLC-based WTSD is better than the WFLC. The performance when tracking voluntary motion is similar among all systems. This study has proven the feasibility of implementing various tremor estimators in a cost-effective embedded system, and provided a real-time performance assessment of four tremor estimators.
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 2856-2865
Open AccessReal-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device
The side effects and complications of traditional treatments for treating pathological tremor have led to a growing research interest in wearable tremor suppression devices (WTSDs) as an alternative approach. Similar to how the human brain coordinates the function of the human system, a tremor estimator determines how a WTSD functions. Although many tremor estimation algorithms have been developed and validated, whether they can be implemented on a cost-effective embedded system has not been studied; furthermore, their effectiveness on tremor signals with multiple harmonics has not been investigated. Therefore, in this study, four tremor estimators were implemented, evaluated, and compared: Weighted-frequency Fourier Linear Combiner (WFLC), WFLC-based Kalman Filter (WFLC-KF), Band-limited Multiple FLC, and enhanced High-order WFLC-KF (eHWFLC-KF). This study aimed to evaluate the performance of each algorithm on a bench-top tremor suppression system with 18 recorded tremor motion datasets; and compare the performance of each estimator. The experimental evaluation showed that the eHWFLC-KF-based WTSD achieved the best performance when suppressing tremor with an average of 89.3% reduction in tremor power, and an average error when tracking voluntary motion of 6.6°/s. Statistical analysis indicated that the eHWFLC-KF-based WTSD is able to reduce the power of tremor better than the WFLC and WFLC-KF, and the BMFLC-based WTSD is better than the WFLC. The performance when tracking voluntary motion is similar among all systems. This study has proven the feasibility of implementing various tremor estimators in a cost-effective embedded system, and provided a real-time performance assessment of four tremor estimators.
- Open Access
Using Deep Learning for Task and Tremor Type Classification in People with Parkinson’s Disease
Hand tremor is one of the dominating symptoms of Parkinson’s disease (PD), which significantly limits activities of daily living. Along with medications, wearable devices have been proposed to suppress tremor. However, suppressing tremor without interfering with voluntary motion remains challenging and improvements are needed. The main goal of this work was to design algorithms for the automatic identification of the tremor type and voluntary motions, using only surface electromyography (sEMG) data. Towards this goal, a bidirectional long short-term memory (BiLSTM) algorithm was implemented that uses sEMG data to identify the motion and tremor type of people living with PD when performing a task. Moreover, in order to automate the training process, hyperparamter selection was performed using a regularized evolutionary algorithm. The results show that the accuracy of task classification among 15 people living with PD was , and the accuracy of tremor classification was . Both models performed significantly above chance levels (20% and 33% for task and tremor classification, respectively). Thus, it was concluded that the trained models, based on using purely sEMG signals, could successfully identify the task and tremor types.Open AccessUsing Deep Learning for Task and Tremor Type Classification in People with Parkinson’s Disease
Hand tremor is one of the dominating symptoms of Parkinson’s disease (PD), which significantly limits activities of daily living. Along with medications, wearable devices have been proposed to suppress tremor. However, suppressing tremor without interfering with voluntary motion remains challenging and improvements are needed. The main goal of this work was to design algorithms for the automatic identification of the tremor type and voluntary motions, using only surface electromyography (sEMG) data. Towards this goal, a bidirectional long short-term memory (BiLSTM) algorithm was implemented that uses sEMG data to identify the motion and tremor type of people living with PD when performing a task. Moreover, in order to automate the training process, hyperparamter selection was performed using a regularized evolutionary algorithm. The results show that the accuracy of task classification among 15 people living with PD was , and the accuracy of tremor classification was . Both models performed significantly above chance levels (20% and 33% for task and tremor classification, respectively). Thus, it was concluded that the trained models, based on using purely sEMG signals, could successfully identify the task and tremor types. - Open Access
- 9 February 2019
- Published by Springer Nature in BMC Neurology
- Vol. 19 (1) , 1-10
Ambroxol as a novel disease-modifying treatment for Parkinson’s disease dementia: protocol for a single-centre, randomized, double-blind, placebo-controlled trial
Currently there are no disease-modifying treatments for Parkinson’s disease dementia (PDD), a condition linked to aggregation of the protein α-synuclein in subcortical and cortical brain areas. One of the leading genetic risk factors for Parkinson's disease is being a carrier in the gene for β-Glucocerebrosidase (GCase; gene name GBA1). Studies in cell culture and animal models have shown that raising the levels of GCase can decrease levels of α-synuclein. Ambroxol is a pharmacological chaperone for GCase and is able to raise the levels of GCase and could therefore be a disease-modifying treatment for PDD. The aims of this trial are to determine if Ambroxol is safe and well-tolerated by individuals with PDD and if Ambroxol affects cognitive, biochemical, and neuroimaging measures. This is a phase II, single-centre, double-blind, randomized placebo-controlled trial involving 75 individuals with mild to moderate PDD. Participants will be randomized into Ambroxol high-dose (1050 mg/day), low-dose (525 mg/day), or placebo treatment arms. Assessments will be undertaken at baseline, 6-months, and 12-months follow up times. Primary outcome measures will be the Alzheimer’s disease Assessment Scale-cognitive subscale (ADAS-Cog) and the ADCS Clinician’s Global Impression of Change (CGIC). Secondary measures will include the Parkinson’s disease Cognitive Rating Scale, Clinical Dementia Rating, Trail Making Test, Stroop Test, Unified Parkinson’s disease Rating Scale, Purdue Pegboard, Timed Up and Go, and gait kinematics. Markers of neurodegeneration will include MRI and CSF measures. Pharmacokinetics and pharmacodynamics of Ambroxol will be examined through plasma levels during dose titration phase and evaluation of GCase activity in lymphocytes. If found effective and safe, Ambroxol will be one of the first disease-modifying treatments for PDD. ClinicalTrials.gov NCT02914366, 26 Sep 2016/retrospectively registered.
- 9 February 2019
- Published by Springer Nature in BMC Neurology
- Vol. 19 (1) , 1-10
Open AccessAmbroxol as a novel disease-modifying treatment for Parkinson’s disease dementia: protocol for a single-centre, randomized, double-blind, placebo-controlled trial
Currently there are no disease-modifying treatments for Parkinson’s disease dementia (PDD), a condition linked to aggregation of the protein α-synuclein in subcortical and cortical brain areas. One of the leading genetic risk factors for Parkinson's disease is being a carrier in the gene for β-Glucocerebrosidase (GCase; gene name GBA1). Studies in cell culture and animal models have shown that raising the levels of GCase can decrease levels of α-synuclein. Ambroxol is a pharmacological chaperone for GCase and is able to raise the levels of GCase and could therefore be a disease-modifying treatment for PDD. The aims of this trial are to determine if Ambroxol is safe and well-tolerated by individuals with PDD and if Ambroxol affects cognitive, biochemical, and neuroimaging measures. This is a phase II, single-centre, double-blind, randomized placebo-controlled trial involving 75 individuals with mild to moderate PDD. Participants will be randomized into Ambroxol high-dose (1050 mg/day), low-dose (525 mg/day), or placebo treatment arms. Assessments will be undertaken at baseline, 6-months, and 12-months follow up times. Primary outcome measures will be the Alzheimer’s disease Assessment Scale-cognitive subscale (ADAS-Cog) and the ADCS Clinician’s Global Impression of Change (CGIC). Secondary measures will include the Parkinson’s disease Cognitive Rating Scale, Clinical Dementia Rating, Trail Making Test, Stroop Test, Unified Parkinson’s disease Rating Scale, Purdue Pegboard, Timed Up and Go, and gait kinematics. Markers of neurodegeneration will include MRI and CSF measures. Pharmacokinetics and pharmacodynamics of Ambroxol will be examined through plasma levels during dose titration phase and evaluation of GCase activity in lymphocytes. If found effective and safe, Ambroxol will be one of the first disease-modifying treatments for PDD. ClinicalTrials.gov NCT02914366, 26 Sep 2016/retrospectively registered.
- Open Access
- 1 April 2018
- Published by SAGE Publications in Sage Open
- Vol. 8 (2)
Self-Reported Physical Activity Among Individuals With Parkinson’s Disease
Although physical activity is generally thought to be beneficial for individuals with Parkinson’s disease (PD), there is limited information regarding current rates of physical activity within this population. In this study, we measured self-reported physical activity levels of individuals with PD and explored factors that affected physical activity engagement. Sixty-one individuals living with PD completed a modified form of the Physical Activity Scale for Individuals With Physical Disabilities. Reported activity was high and exceeds published guidelines for individuals with limited mobility. Major facilitators of physical activity included (a) positive impact on PD-related symptoms, (b) social motivation, and (c) regularity or predictability of the activity. The major barrier to physical activity was PD symptom severity (e.g., lack of balance, gait impairment, tremor, and fatigue).
- 1 April 2018
- Published by SAGE Publications in Sage Open
- Vol. 8 (2)
Open AccessSelf-Reported Physical Activity Among Individuals With Parkinson’s Disease
Although physical activity is generally thought to be beneficial for individuals with Parkinson’s disease (PD), there is limited information regarding current rates of physical activity within this population. In this study, we measured self-reported physical activity levels of individuals with PD and explored factors that affected physical activity engagement. Sixty-one individuals living with PD completed a modified form of the Physical Activity Scale for Individuals With Physical Disabilities. Reported activity was high and exceeds published guidelines for individuals with limited mobility. Major facilitators of physical activity included (a) positive impact on PD-related symptoms, (b) social motivation, and (c) regularity or predictability of the activity. The major barrier to physical activity was PD symptom severity (e.g., lack of balance, gait impairment, tremor, and fatigue).
- Open Access
- 27 September 2017
- Published by Society for Neuroscience in eneuro
- Vol. 4 (5)
Automatic Online Motor Control Is Intact in Parkinson’s Disease With and Without Perceptual Awareness
In the double-step paradigm, healthy human participants automatically correct reaching movements when targets are displaced. Motor deficits are prominent in Parkinson’s disease (PD) patients. In the lone investigation of online motor correction in PD using the double-step task, a recent study found that PD patients performed unconscious adjustments appropriately but seemed impaired for consciously-perceived modifications. Conscious perception of target movement was achieved by linking displacement to movement onset. PD-related bradykinesia disproportionately prolonged preparatory phases for movements to original target locations for patients, potentially accounting for deficits. Eliminating this confound in a double-step task, we evaluated the effect of conscious awareness of trajectory change on online motor corrections in PD. On and off dopaminergic therapy, PD patients (n= 14) and healthy controls (n= 14) reached to peripheral visual targets that remained stationary or unexpectedly moved during an initial saccade. Saccade latencies in PD are comparable to controls’. Hence, target displacements occurred at equal times across groups. Target jump size affected conscious awareness, confirmed in an independent target displacement judgment task. Small jumps were subliminal, but large target displacements were consciously perceived. Contrary to the previous result, PD patients performed online motor corrections normally and automatically, irrespective of conscious perception. Patients evidenced equivalent movement durations for jump and stay trials, and trajectories for patients and controls were identical, irrespective of conscious perception. Dopaminergic therapy had no effect on performance. In summary, online motor control is intact in PD, unaffected by conscious perceptual awareness. The basal ganglia are not implicated in online corrective responses.
- 27 September 2017
- Published by Society for Neuroscience in eneuro
- Vol. 4 (5)
Open AccessAutomatic Online Motor Control Is Intact in Parkinson’s Disease With and Without Perceptual Awareness
In the double-step paradigm, healthy human participants automatically correct reaching movements when targets are displaced. Motor deficits are prominent in Parkinson’s disease (PD) patients. In the lone investigation of online motor correction in PD using the double-step task, a recent study found that PD patients performed unconscious adjustments appropriately but seemed impaired for consciously-perceived modifications. Conscious perception of target movement was achieved by linking displacement to movement onset. PD-related bradykinesia disproportionately prolonged preparatory phases for movements to original target locations for patients, potentially accounting for deficits. Eliminating this confound in a double-step task, we evaluated the effect of conscious awareness of trajectory change on online motor corrections in PD. On and off dopaminergic therapy, PD patients (n= 14) and healthy controls (n= 14) reached to peripheral visual targets that remained stationary or unexpectedly moved during an initial saccade. Saccade latencies in PD are comparable to controls’. Hence, target displacements occurred at equal times across groups. Target jump size affected conscious awareness, confirmed in an independent target displacement judgment task. Small jumps were subliminal, but large target displacements were consciously perceived. Contrary to the previous result, PD patients performed online motor corrections normally and automatically, irrespective of conscious perception. Patients evidenced equivalent movement durations for jump and stay trials, and trajectories for patients and controls were identical, irrespective of conscious perception. Dopaminergic therapy had no effect on performance. In summary, online motor control is intact in PD, unaffected by conscious perceptual awareness. The basal ganglia are not implicated in online corrective responses.
- 24 August 2011
- Published by Springer Nature
- p. 115-159
Movement Disorders