Zafer Iscan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zafer Iscan has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Zümray Dokur
Istanbul Technical University, Turkey
5 shared publications- Zümray Dokur
Istanbul Technical University
4 shared publications - Vadim Nikulin
Max Planck Institute for Human Cognitive and Brain Sciences
3 shared publications - Ayhan Yüksel
Department of Electronics and Communication Engineering, Istanbul Technical University, 34469 Maslak, Istanbul, Turkey
2 shared publications - Christine DeLorenzo
Stony Brook University
2 shared publications Evgeny Blagovechtchenski
Centre for Cognition and Decision Making, National Research University Higher School of Economics Moscow, Russia
2 shared publications
Latest Publications
- 16 August 2018
- Published by Springer Nature in Experimental Brain Research
- Vol. 236 (11) , 3003-3014
Pre-stimulus theta power is correlated with variation of motor evoked potential latency: a single-pulse TMS study
There has been a growing interest in the role of pre-stimulus oscillations on cortical excitability in visual and motor systems. Prior studies focused on the relationship between pre-stimulus neuronal activity and TMS-evoked motor evoked potentials (MEPs) have reported heterogeneous results. We aimed to assess the role of pre-stimulus neural activity on the latency of MEPs, which might enhance our understanding of the variability of MEP signals, and potentially provide information on the role played by cortical activity fluctuations in the excitability of corticospinal pathways. Near-threshold single-pulse TMS (spTMS) was applied at random intervals over the primary motor cortex of 14 healthy participants while they sat passively, to trigger hand muscle contractions. Multichannel EEG was recorded during spTMS blocks. Spearman correlations between both the variation in MEP onset latencies and peak-to-peak MEP amplitudes, and the pre-stimulus power of EEG oscillations were calculated across participants. We found that the variation in MEP latency was positively correlated with pre-stimulus power in the theta range (4–7 Hz) in a broad time window (− 3.1 to − 1.9 s) preceding the spTMS generating the MEP. No correlation between pre-stimulus power in any frequency band and MEP amplitude was found. Our results show that pre-stimulus theta oscillations are correlated with the variation in MEP latency, an outcome measure determined by fiber conduction velocity and synaptic delays along the corticospinal tract. This finding could prove useful for clinicians using MEP latency-based information in pre- or intra-operative diagnostics of corticospinal impairment.
- 16 August 2018
- Published by Springer Nature in Experimental Brain Research
- Vol. 236 (11) , 3003-3014
Pre-stimulus theta power is correlated with variation of motor evoked potential latency: a single-pulse TMS study
There has been a growing interest in the role of pre-stimulus oscillations on cortical excitability in visual and motor systems. Prior studies focused on the relationship between pre-stimulus neuronal activity and TMS-evoked motor evoked potentials (MEPs) have reported heterogeneous results. We aimed to assess the role of pre-stimulus neural activity on the latency of MEPs, which might enhance our understanding of the variability of MEP signals, and potentially provide information on the role played by cortical activity fluctuations in the excitability of corticospinal pathways. Near-threshold single-pulse TMS (spTMS) was applied at random intervals over the primary motor cortex of 14 healthy participants while they sat passively, to trigger hand muscle contractions. Multichannel EEG was recorded during spTMS blocks. Spearman correlations between both the variation in MEP onset latencies and peak-to-peak MEP amplitudes, and the pre-stimulus power of EEG oscillations were calculated across participants. We found that the variation in MEP latency was positively correlated with pre-stimulus power in the theta range (4–7 Hz) in a broad time window (− 3.1 to − 1.9 s) preceding the spTMS generating the MEP. No correlation between pre-stimulus power in any frequency band and MEP amplitude was found. Our results show that pre-stimulus theta oscillations are correlated with the variation in MEP latency, an outcome measure determined by fiber conduction velocity and synaptic delays along the corticospinal tract. This finding could prove useful for clinicians using MEP latency-based information in pre- or intra-operative diagnostics of corticospinal impairment.
- Open Access
- 23 January 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0191673
Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations
Brain-computer interface (BCI) paradigms are usually tested when environmental and biological artifacts are intentionally avoided. In this study, we deliberately introduced different perturbations in order to test the robustness of a steady state visual evoked potential (SSVEP) based BCI. Specifically we investigated to what extent a drop in performance is related to the degraded quality of EEG signals or rather due to increased cognitive load. In the online tasks, subjects focused on one of the four circles and gave feedback on the correctness of the classification under four conditions randomized across subjects: Control (no perturbation), Speaking (counting loudly and repeatedly from one to ten), Thinking (mentally counting repeatedly from one to ten), and Listening (listening to verbal counting from one to ten). Decision tree, Naïve Bayes and K-Nearest Neighbor classifiers were used to evaluate the classification performance using features generated by canonical correlation analysis. During the online condition, Speaking and Thinking decreased moderately the mean classification accuracy compared to Control condition whereas there was no significant difference between Listening and Control conditions across subjects. The performances were sensitive to the classification method and to the perturbation conditions. We have not observed significant artifacts in EEG during perturbations in the frequency range of interest except in theta band. Therefore we concluded that the drop in the performance is likely to have a cognitive origin. During the Listening condition relative alpha power in a broad area including central and temporal regions primarily over the left hemisphere correlated negatively with the performance thus most likely indicating active suppression of the distracting presentation of the playback. This is the first study that systematically evaluates the effects of natural artifacts (i.e. mental, verbal and audio perturbations) on SSVEP-based BCIs. The results can be used to improve individual classification performance taking into account effects of perturbations.
- 23 January 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0191673
Open AccessSteady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations
Brain-computer interface (BCI) paradigms are usually tested when environmental and biological artifacts are intentionally avoided. In this study, we deliberately introduced different perturbations in order to test the robustness of a steady state visual evoked potential (SSVEP) based BCI. Specifically we investigated to what extent a drop in performance is related to the degraded quality of EEG signals or rather due to increased cognitive load. In the online tasks, subjects focused on one of the four circles and gave feedback on the correctness of the classification under four conditions randomized across subjects: Control (no perturbation), Speaking (counting loudly and repeatedly from one to ten), Thinking (mentally counting repeatedly from one to ten), and Listening (listening to verbal counting from one to ten). Decision tree, Naïve Bayes and K-Nearest Neighbor classifiers were used to evaluate the classification performance using features generated by canonical correlation analysis. During the online condition, Speaking and Thinking decreased moderately the mean classification accuracy compared to Control condition whereas there was no significant difference between Listening and Control conditions across subjects. The performances were sensitive to the classification method and to the perturbation conditions. We have not observed significant artifacts in EEG during perturbations in the frequency range of interest except in theta band. Therefore we concluded that the drop in the performance is likely to have a cognitive origin. During the Listening condition relative alpha power in a broad area including central and temporal regions primarily over the left hemisphere correlated negatively with the performance thus most likely indicating active suppression of the distracting presentation of the playback. This is the first study that systematically evaluates the effects of natural artifacts (i.e. mental, verbal and audio perturbations) on SSVEP-based BCIs. The results can be used to improve individual classification performance taking into account effects of perturbations.
- 1 October 2017
- Published by Elsevier in European Neuropsychopharmacology
- Vol. 27 (10) , 1011-1021
A positron emission tomography study of the serotonergic system in relation to anxiety in depression
- 1 October 2017
- Published by Elsevier in European Neuropsychopharmacology
- Vol. 27 (10) , 1011-1021
A positron emission tomography study of the serotonergic system in relation to anxiety in depression
- Open Access
- 7 October 2016
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 10, 504
Pre-stimulus Alpha Oscillations and Inter-subject Variability of Motor Evoked Potentials in Single- and Paired-Pulse TMS Paradigms
Inter- and intra-subject variability of the motor evoked potentials (MEPs) to TMS is a well-known phenomenon. Although a possible link between this variability and ongoing brain oscillations was demonstrated, the results of the studies are not consistent with each other. Exploring this topic further is important since the modulation of MEPs provides unique possibility to relate oscillatory cortical phenomena to the state of the motor cortex probed with TMS. Given that alpha oscillations were shown to reflect cortical excitability, we hypothesized that their power and variability might explain the modulation of subject-specific MEPs to single- and paired-pulse TMS (spTMS, ppTMS, respectively). Neuronal activity was recorded with multichannel EEG. We used spTMS and two ppTMS conditions: intracortical facilitation (ICF) and short-interval intracortical inhibition (SICI). Spearman correlations were calculated within and across subjects between MEPs and the pre-stimulus power of alpha oscillations in low (8–10 Hz) and high (10–12 Hz) frequency bands. Coefficient of quartile variation was used to measure variability. Across-subject analysis revealed no difference in the pre-stimulus alpha power among the TMS conditions. However, the variability of high-alpha power in spTMS condition was larger than in the SICI condition. In ICF condition pre-stimulus high-alpha power variability correlated positively with MEP amplitude variability. No correlation has been observed between the pre-stimulus alpha power and MEP responses in any of the conditions. Our results for the first time show that the variability of the alpha oscillations can be more predictive of TMS effects than the commonly used power of oscillations and we provide further support for the dissociation of high and low-alpha bands in predicting responses produced by the stimulation of the motor cortex.
- 7 October 2016
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 10, 504
Open AccessPre-stimulus Alpha Oscillations and Inter-subject Variability of Motor Evoked Potentials in Single- and Paired-Pulse TMS Paradigms
Inter- and intra-subject variability of the motor evoked potentials (MEPs) to TMS is a well-known phenomenon. Although a possible link between this variability and ongoing brain oscillations was demonstrated, the results of the studies are not consistent with each other. Exploring this topic further is important since the modulation of MEPs provides unique possibility to relate oscillatory cortical phenomena to the state of the motor cortex probed with TMS. Given that alpha oscillations were shown to reflect cortical excitability, we hypothesized that their power and variability might explain the modulation of subject-specific MEPs to single- and paired-pulse TMS (spTMS, ppTMS, respectively). Neuronal activity was recorded with multichannel EEG. We used spTMS and two ppTMS conditions: intracortical facilitation (ICF) and short-interval intracortical inhibition (SICI). Spearman correlations were calculated within and across subjects between MEPs and the pre-stimulus power of alpha oscillations in low (8–10 Hz) and high (10–12 Hz) frequency bands. Coefficient of quartile variation was used to measure variability. Across-subject analysis revealed no difference in the pre-stimulus alpha power among the TMS conditions. However, the variability of high-alpha power in spTMS condition was larger than in the SICI condition. In ICF condition pre-stimulus high-alpha power variability correlated positively with MEP amplitude variability. No correlation has been observed between the pre-stimulus alpha power and MEP responses in any of the conditions. Our results for the first time show that the variability of the alpha oscillations can be more predictive of TMS effects than the commonly used power of oscillations and we provide further support for the dissociation of high and low-alpha bands in predicting responses produced by the stimulation of the motor cortex.
- 1 September 2016
- Published by Elsevier in Neuroscience
- Vol. 331, 109-119
Long-Range Temporal Correlations in the amplitude of alpha oscillations predict and reflect strength of intracortical facilitation: Combined TMS and EEG study
- 1 September 2016
- Published by Elsevier in Neuroscience
- Vol. 331, 109-119
Long-Range Temporal Correlations in the amplitude of alpha oscillations predict and reflect strength of intracortical facilitation: Combined TMS and EEG study
- Open Access
- 28 May 2015
- Published by Wiley in Human Brain Mapping
- Vol. 36 (9) , 3472-3485
Test–retest reliability of freesurfer measurements within and between sites: Effects of visual approval process
In the last decade, many studies have used automated processes to analyze magnetic resonance imaging (MRI) data such as cortical thickness, which is one indicator of neuronal health. Due to the convenience of image processing software (e.g., FreeSurfer), standard practice is to rely on automated results without performing visual inspection of intermediate processing. In this work, structural MRIs of 40 healthy controls who were scanned twice were used to determine the test–retest reliability of FreeSurfer‐derived cortical measures in four groups of subjects—those 25 that passed visual inspection (approved), those 15 that failed visual inspection (disapproved), a combined group, and a subset of 10 subjects (Travel) whose test and retest scans occurred at different sites. Test–retest correlation (TRC), intraclass correlation coefficient (ICC), and percent difference (PD) were used to measure the reliability in the Destrieux and Desikan–Killiany (DK) atlases. In the approved subjects, reliability of cortical thickness/surface area/volume (DK atlas only) were: TRC (0.82/0.88/0.88), ICC (0.81/0.87/0.88), PD (0.86/1.19/1.39), which represent a significant improvement over these measures when disapproved subjects are included. Travel subjects’ results show that cortical thickness reliability is more sensitive to site differences than the cortical surface area and volume. To determine the effect of visual inspection on sample size required for studies of MRI‐derived cortical thickness, the number of subjects required to show group differences was calculated. Significant differences observed across imaging sites, between visually approved/disapproved subjects, and across regions with different sizes suggest that these measures should be used with caution. Hum Brain Mapp 36:3472–3485, 2015. © 2015 Wiley Periodicals, Inc.
- 28 May 2015
- Published by Wiley in Human Brain Mapping
- Vol. 36 (9) , 3472-3485
Open AccessTest–retest reliability of freesurfer measurements within and between sites: Effects of visual approval process
In the last decade, many studies have used automated processes to analyze magnetic resonance imaging (MRI) data such as cortical thickness, which is one indicator of neuronal health. Due to the convenience of image processing software (e.g., FreeSurfer), standard practice is to rely on automated results without performing visual inspection of intermediate processing. In this work, structural MRIs of 40 healthy controls who were scanned twice were used to determine the test–retest reliability of FreeSurfer‐derived cortical measures in four groups of subjects—those 25 that passed visual inspection (approved), those 15 that failed visual inspection (disapproved), a combined group, and a subset of 10 subjects (Travel) whose test and retest scans occurred at different sites. Test–retest correlation (TRC), intraclass correlation coefficient (ICC), and percent difference (PD) were used to measure the reliability in the Destrieux and Desikan–Killiany (DK) atlases. In the approved subjects, reliability of cortical thickness/surface area/volume (DK atlas only) were: TRC (0.82/0.88/0.88), ICC (0.81/0.87/0.88), PD (0.86/1.19/1.39), which represent a significant improvement over these measures when disapproved subjects are included. Travel subjects’ results show that cortical thickness reliability is more sensitive to site differences than the cortical surface area and volume. To determine the effect of visual inspection on sample size required for studies of MRI‐derived cortical thickness, the number of subjects required to show group differences was calculated. Significant differences observed across imaging sites, between visually approved/disapproved subjects, and across regions with different sizes suggest that these measures should be used with caution. Hum Brain Mapp 36:3472–3485, 2015. © 2015 Wiley Periodicals, Inc.
- 1 April 2015
- Published by Pleiades Publishing Ltd in Pattern Recognition and Image Analysis
- Vol. 25 (2) , 321-326
Classification of steady state visual evoked potentials by Multi-Class T-Weight Method
In this paper, Multi-Class T-Weight Method (MCTW) is presented for classification in brain-computer interface (BCI) systems. Proposed method is an extension of the existing Improved T-Weight method for multi-class problems. The method was tested on the frequency and correlation based features obtained from electroencephalogram data of 20 Subjects in a steady state visual evoked potential (SSVEP) based offline BCI classification task. Obtained classification performances with different classifiers show that the MCTW method compete with the other well-known classifiers like linear discriminant analysis (LDA) and support vector machines (SVMs). Therefore, it can be used in classifying SSVEP based electroencephalogram data with proper features.
- 1 April 2015
- Published by Pleiades Publishing Ltd in Pattern Recognition and Image Analysis
- Vol. 25 (2) , 321-326
Classification of steady state visual evoked potentials by Multi-Class T-Weight Method
In this paper, Multi-Class T-Weight Method (MCTW) is presented for classification in brain-computer interface (BCI) systems. Proposed method is an extension of the existing Improved T-Weight method for multi-class problems. The method was tested on the frequency and correlation based features obtained from electroencephalogram data of 20 Subjects in a steady state visual evoked potential (SSVEP) based offline BCI classification task. Obtained classification performances with different classifiers show that the MCTW method compete with the other well-known classifiers like linear discriminant analysis (LDA) and support vector machines (SVMs). Therefore, it can be used in classifying SSVEP based electroencephalogram data with proper features.
- 1 March 2014
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 10, 145-152
A novel steady-state visually evoked potential-based brain–computer interface design: Character Plotter
- 1 March 2014
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 10, 145-152
A novel steady-state visually evoked potential-based brain–computer interface design: Character Plotter
- Open Access
- 26 October 2011
- Published by Association for Computing Machinery (ACM)
- p. 1-5
Improved T-Weight method in classification of slow cortical potentials
- 26 October 2011
- Published by Association for Computing Machinery (ACM)
- p. 1-5
Open AccessImproved T-Weight method in classification of slow cortical potentials
- 13 September 2011
- Published by Pleiades Publishing Ltd in Pattern Recognition and Image Analysis
- Vol. 21 (3) , 481-485
Detection of P300 wave from EEG data for brain-computer interface applications
In this paper, successful detection of P300 wave embedded into electroencephalogram (EEG) data is aimed. Detection performance of a previously applied method is increased by using proper pre-processing scheme. Development in the detection performance in terms of overall classification accuracy is presented in a detailed manner. The proposed method is highly capable of detecting the minor differences and can be applied to various classification problems.
- 13 September 2011
- Published by Pleiades Publishing Ltd in Pattern Recognition and Image Analysis
- Vol. 21 (3) , 481-485
Detection of P300 wave from EEG data for brain-computer interface applications
In this paper, successful detection of P300 wave embedded into electroencephalogram (EEG) data is aimed. Detection performance of a previously applied method is increased by using proper pre-processing scheme. Development in the detection performance in terms of overall classification accuracy is presented in a detailed manner. The proposed method is highly capable of detecting the minor differences and can be applied to various classification problems.