Jonathan J. Wyatt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonathan J. Wyatt has a total of 128 co-authors. Here are the top co-authors by number of shared publications:
Hazel M. McCallum
Translation and Clinical Research Institute, Newcastle University, Newcastle upon Tyne, UK
7 shared publications- Hazel McCallum
Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
6 shared publications Rachel A. Pearson
6 shared publicationsFlorian Wiesinger
GE Healthcare, Munich, Germany
5 shared publications- Rachel Brooks-Pearson
Northern Centre for Cancer Care), Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle Upon Tyne, UK
5 shared publications Sandeep Kaushik
GE Healthcare, Munich, Germany
5 shared publications
Latest Publications
- 21 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (9) , 095008
IPEM Topical Report: A National Survey of MRI Use for External Beam Radiotherapy Treatment Planning in the UK: 2025 IPEM Survey Results
Magnetic Resonance Imaging (MRI) offers superior soft tissue contrast compared to Computed Tomography (CT), making it highly valuable in external beam radiotherapy (EBRT) planning. However, there are a number of barriers that have limited widespread use of MRI for EBRT planning in the UK such as limited access to MRI scanners and lack of training and guidance. Following the 2018 Institute of Physics and Engineering in Medicine (IPEM) survey on MRI use in UK radiotherapy centres, data were collected from 68 centres across the UK in 2025 to reassess MRI access, utilisation, and adherence to 2021 IPEM guidance on MRI in EBRT planning. With a 79% (54/68) complete response rate, the survey revealed increased integration of MRI into EBRT planning workflows, particularly for brain, spine, and prostate cancers. However, access remains variable, with only five centres reporting MRI scanners dedicated for radiotherapy. Compliance with recommended imaging MRI sequences and quality assurance procedures has improved but remains variable, especially among centres relying on Picture Archiving and Communication Systems (PACS)sourced images. Barriers such as capital investment, staffing, and training persist, although clinical engagement and future planning for MRI-only workflows and Artificial Intelligence (AI)-based tools are increasing. These findings underscore the need for continued investment, updated guidance, and multidisciplinary collaboration to support the safe and effective expansion of MRI in radiotherapy planning.
- 21 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (9) , 095008
IPEM Topical Report: A National Survey of MRI Use for External Beam Radiotherapy Treatment Planning in the UK: 2025 IPEM Survey Results
Magnetic Resonance Imaging (MRI) offers superior soft tissue contrast compared to Computed Tomography (CT), making it highly valuable in external beam radiotherapy (EBRT) planning. However, there are a number of barriers that have limited widespread use of MRI for EBRT planning in the UK such as limited access to MRI scanners and lack of training and guidance. Following the 2018 Institute of Physics and Engineering in Medicine (IPEM) survey on MRI use in UK radiotherapy centres, data were collected from 68 centres across the UK in 2025 to reassess MRI access, utilisation, and adherence to 2021 IPEM guidance on MRI in EBRT planning. With a 79% (54/68) complete response rate, the survey revealed increased integration of MRI into EBRT planning workflows, particularly for brain, spine, and prostate cancers. However, access remains variable, with only five centres reporting MRI scanners dedicated for radiotherapy. Compliance with recommended imaging MRI sequences and quality assurance procedures has improved but remains variable, especially among centres relying on Picture Archiving and Communication Systems (PACS)sourced images. Barriers such as capital investment, staffing, and training persist, although clinical engagement and future planning for MRI-only workflows and Artificial Intelligence (AI)-based tools are increasing. These findings underscore the need for continued investment, updated guidance, and multidisciplinary collaboration to support the safe and effective expansion of MRI in radiotherapy planning.
- 13 April 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 219, 111530
Standardizing MRI-only radiotherapy commissioning: Benchmark dataset and acceptance levels from the MESCAL initiative
- 13 April 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 219, 111530
Standardizing MRI-only radiotherapy commissioning: Benchmark dataset and acceptance levels from the MESCAL initiative
- Open Access
- 14 February 2026
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 58, 101122
Automated MR-only radiotherapy outperforms CT-based radiotherapy and decreases hands-on time for head-and-neck cancer treatment
- 14 February 2026
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 58, 101122
Open AccessAutomated MR-only radiotherapy outperforms CT-based radiotherapy and decreases hands-on time for head-and-neck cancer treatment
- Open Access
- 9 February 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 37
A combined automatic organ at risk contouring and synthetic Computed Tomography solution for pelvic Magnetic Resonance-only radiotherapy
- 9 February 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 37
Open AccessA combined automatic organ at risk contouring and synthetic Computed Tomography solution for pelvic Magnetic Resonance-only radiotherapy
- 17 September 2025
- Published by Elsevier in Radiography
- Vol. 31, 103168
Apparent diffusion coefficient benchmarking and inter-scanner variability; preparing for biological image guided adaptive radiotherapy treatments
- 17 September 2025
- Published by Elsevier in Radiography
- Vol. 31, 103168
Apparent diffusion coefficient benchmarking and inter-scanner variability; preparing for biological image guided adaptive radiotherapy treatments
- Open Access
- 16 July 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1176) , 2099-2105
Dose differences between patients treated with MR-only, CT-only, or MR-CT fusion radiotherapy for prostate cancer
Objectives: Magnetic Resonance (MR)-only radiotherapy has been clinically implemented but its dose impact has not been assessed in clinical practice. This study evaluated the volume and dose differences between patients treated with CT-only, MR-CT fusion, or MR-only prostate radiotherapy pathways. Methods: Four hundred fifty-four patients from a single centre were treated using MR-only (n = 96), CT-only (n = 248), or MR-CT (n = 110) pathways. Patients were selected for different pathways based solely on geographic location and treatment date. Patients were contoured by the same group of delineators and were planned for 60 Gy in 20 fractions by an automated planning algorithm. Clinical Target Volume (CTV), bladder, penile bulb and rectum volumes, and clinical dose constraints were compared with Kurshkal-Wallis tests, adjusted for multiple testing with a P<.05 significance level. Results: Median MR-only CTVs were 5 cm3 smaller than CT-only (P=.004). Penile bulb Dmean was 12.0 Gy (CT-only), 9.1 Gy (MR-CT), and 5.9 Gy (MR-only, P<.001), with 79.0%, 90.9%, and 95.8% of patients within constraint. Rectum D2 cm3 was 57.4 Gy (CT-only), 57.6 Gy (MR-CT), and 56.5 Gy (MR-only, P<.001), with 35.1%, 20.9%, and 56.2% of patients within rectum V60 Gy constraint. Conclusions: The MR-only pathway produced significant reductions of 13% in CTV volume, 51% in penile bulb Dmean, and 2% in rectum D2 cm3 compared to CT-only. Advances in knowledge: The dose benefit from MR-only has been assessed in clinical practice, demonstrating significant reductions in penile bulb and rectum doses compared to both CT-only and MR-CT pathways. This suggests the MR-only pathway is required to provide the full benefit of MR contouring to reduce toxicities from prostate radiotherapy.
- 16 July 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1176) , 2099-2105
Open AccessDose differences between patients treated with MR-only, CT-only, or MR-CT fusion radiotherapy for prostate cancer
Objectives: Magnetic Resonance (MR)-only radiotherapy has been clinically implemented but its dose impact has not been assessed in clinical practice. This study evaluated the volume and dose differences between patients treated with CT-only, MR-CT fusion, or MR-only prostate radiotherapy pathways. Methods: Four hundred fifty-four patients from a single centre were treated using MR-only (n = 96), CT-only (n = 248), or MR-CT (n = 110) pathways. Patients were selected for different pathways based solely on geographic location and treatment date. Patients were contoured by the same group of delineators and were planned for 60 Gy in 20 fractions by an automated planning algorithm. Clinical Target Volume (CTV), bladder, penile bulb and rectum volumes, and clinical dose constraints were compared with Kurshkal-Wallis tests, adjusted for multiple testing with a P<.05 significance level. Results: Median MR-only CTVs were 5 cm3 smaller than CT-only (P=.004). Penile bulb Dmean was 12.0 Gy (CT-only), 9.1 Gy (MR-CT), and 5.9 Gy (MR-only, P<.001), with 79.0%, 90.9%, and 95.8% of patients within constraint. Rectum D2 cm3 was 57.4 Gy (CT-only), 57.6 Gy (MR-CT), and 56.5 Gy (MR-only, P<.001), with 35.1%, 20.9%, and 56.2% of patients within rectum V60 Gy constraint. Conclusions: The MR-only pathway produced significant reductions of 13% in CTV volume, 51% in penile bulb Dmean, and 2% in rectum D2 cm3 compared to CT-only. Advances in knowledge: The dose benefit from MR-only has been assessed in clinical practice, demonstrating significant reductions in penile bulb and rectum doses compared to both CT-only and MR-CT pathways. This suggests the MR-only pathway is required to provide the full benefit of MR contouring to reduce toxicities from prostate radiotherapy.
- Open Access
- 29 January 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 205, 110762
Synthetic CT generation using Zero TE MR for head-and-neck radiotherapy
- 29 January 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 205, 110762
Open AccessSynthetic CT generation using Zero TE MR for head-and-neck radiotherapy
- Open Access
- 27 December 2024
- Published by Elsevier in Radiography
- Vol. 31 (1) , 333-340
Verification imaging in prostate MR-only radiotherapy: Are fiducial markers necessary?
- 27 December 2024
- Published by Elsevier in Radiography
- Vol. 31 (1) , 333-340
Open AccessVerification imaging in prostate MR-only radiotherapy: Are fiducial markers necessary?
- Open Access
- 8 May 2024
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 9 (8) , 101538
Improving the Efficiency of Single-Isocenter Multiple Metastases Stereotactic Radiosurgery Treatment
- 8 May 2024
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 9 (8) , 101538
Open AccessImproving the Efficiency of Single-Isocenter Multiple Metastases Stereotactic Radiosurgery Treatment