Luis Guimarães
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Luis Guimarães has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Bernardo Almada-Lobo
INESC-TEC, Faculty of Engineering of the University of Porto, Porto, Portugal
15 shared publications - Pedro Amorim
Faculty of Engineering - University of Porto, Porto, Portugal
8 shared publications - Fábio Neves-Moreira
Faculty of Economics - University of Porto, Porto, Portugal
6 shared publications - Gonçalo Figueira
INESC TEC—Institute for Systems and Computer Engineering Technology and Science, 4200-465 Porto, Portugal
4 shared publications - Armando Leitão
INESC Technology and Science (INESC TEC), Campus da FEUP, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
3 shared publications Diego Klabjan
3 shared publications
Latest Publications
- Open Access
- 2 September 2025
- Published by Elsevier in Computers & Industrial Engineering
- Vol. 210
Dynamic dispatching rule selection for the job shop scheduling problem
- 2 September 2025
- Published by Elsevier in Computers & Industrial Engineering
- Vol. 210
Open AccessDynamic dispatching rule selection for the job shop scheduling problem
- 16 February 2024
- Published by Springer Nature
- p. 288-302
A Data-Driven Monitoring Approach for Diagnosing Quality Degradation in a Glass Container Process
- 16 February 2024
- Published by Springer Nature
- p. 288-302
A Data-Driven Monitoring Approach for Diagnosing Quality Degradation in a Glass Container Process
- 1 September 2021
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 213, 107768
Resource definition and allocation for a multi-asset portfolio with heterogeneous degradation
- 1 September 2021
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 213, 107768
Resource definition and allocation for a multi-asset portfolio with heterogeneous degradation
- 4 May 2021
- Published by Wiley in Quality and Reliability Engineering International
- Vol. 37 (6) , 2834-2852
An unsupervised approach for fault diagnosis of power transformers
Electrical utilities apply condition monitoring on power transformers (PTs) to prevent unplanned outages and detect incipient faults. This monitoring is often done using dissolved gas analysis (DGA) coupled with engineering methods to interpret the data, however the obtained results lack accuracy and reproducibility. In order to improve accuracy, various advanced analytical methods have been proposed in the literature. Nonetheless, these methods are often hard to interpret by the decision‐maker and require a substantial amount of failure records to be trained. In the context of the PTs, failure data quality is recurrently questionable, and failure records are scarce when compared to nonfailure records. This work tackles these challenges by proposing a novel unsupervised methodology for diagnosing PT condition. Differently from the supervised approaches in the literature, our method does not require the labeling of DGA records and incorporates a visual representation of the results in a 2D scatter plot to assist in interpretation. A modified clustering technique is used to classify the condition of different PTs using historical DGA data. Finally, well‐known engineering methods are applied to interpret each of the obtained clusters. The approach was validated using data from two different real‐world data sets provided by a generation company and a distribution system operator. The results highlight the advantages of the proposed approach and outperformed engineering methods (from IEC and IEEE standards) and companies legacy method. The approach was also validated on the public IEC TC10 database, showing the capability to achieve comparable accuracy with supervised learning methods from the literature. As a result of the methodology performance, both companies are currently using it in their daily DGA diagnosis.
- 4 May 2021
- Published by Wiley in Quality and Reliability Engineering International
- Vol. 37 (6) , 2834-2852
An unsupervised approach for fault diagnosis of power transformers
Electrical utilities apply condition monitoring on power transformers (PTs) to prevent unplanned outages and detect incipient faults. This monitoring is often done using dissolved gas analysis (DGA) coupled with engineering methods to interpret the data, however the obtained results lack accuracy and reproducibility. In order to improve accuracy, various advanced analytical methods have been proposed in the literature. Nonetheless, these methods are often hard to interpret by the decision‐maker and require a substantial amount of failure records to be trained. In the context of the PTs, failure data quality is recurrently questionable, and failure records are scarce when compared to nonfailure records. This work tackles these challenges by proposing a novel unsupervised methodology for diagnosing PT condition. Differently from the supervised approaches in the literature, our method does not require the labeling of DGA records and incorporates a visual representation of the results in a 2D scatter plot to assist in interpretation. A modified clustering technique is used to classify the condition of different PTs using historical DGA data. Finally, well‐known engineering methods are applied to interpret each of the obtained clusters. The approach was validated using data from two different real‐world data sets provided by a generation company and a distribution system operator. The results highlight the advantages of the proposed approach and outperformed engineering methods (from IEC and IEEE standards) and companies legacy method. The approach was also validated on the public IEC TC10 database, showing the capability to achieve comparable accuracy with supervised learning methods from the literature. As a result of the methodology performance, both companies are currently using it in their daily DGA diagnosis.
- 30 July 2020
- Published by Wiley in International Transactions in Operational Research
- Vol. 28 (2) , 687-715
Improving picking performance at a large retailer warehouse by combining probabilistic simulation, optimization, and discrete‐event simulation
Distribution warehouses are a critical part of supply chains, representing a nonnegligible share of the operating costs. This is especially true for unautomated, labor‐intensive warehouses, partially due to time‐consuming activities such as picking up items or traveling. Inventory categorization techniques, as well as zone storage assignment policies, may help in improving operations, but may also be short‐sighted. This work presents a three‐step methodology that uses probabilistic simulation, optimization, and event‐based simulation (SOS) to analyze and experiment with layout and storage assignment policies to improve the picking performance. In the first stage, picking performance is estimated under different storage assignment policies and zone configurations using a probabilistic model. In the second stage, a mixed integer optimization model defines the overall warehouse layout by selecting the configuration and storage assignment policy for each zone. Finally, the optimized layout solution is tested under demand uncertainty in the third, final simulation phase, through a discrete‐event simulation model. The SOS methodology was validated with three months of operational data from a large retailer's warehouse, successfully illustrating how it may be successfully used for improving the performance of a distribution warehouse.
- 30 July 2020
- Published by Wiley in International Transactions in Operational Research
- Vol. 28 (2) , 687-715
Improving picking performance at a large retailer warehouse by combining probabilistic simulation, optimization, and discrete‐event simulation
Distribution warehouses are a critical part of supply chains, representing a nonnegligible share of the operating costs. This is especially true for unautomated, labor‐intensive warehouses, partially due to time‐consuming activities such as picking up items or traveling. Inventory categorization techniques, as well as zone storage assignment policies, may help in improving operations, but may also be short‐sighted. This work presents a three‐step methodology that uses probabilistic simulation, optimization, and event‐based simulation (SOS) to analyze and experiment with layout and storage assignment policies to improve the picking performance. In the first stage, picking performance is estimated under different storage assignment policies and zone configurations using a probabilistic model. In the second stage, a mixed integer optimization model defines the overall warehouse layout by selecting the configuration and storage assignment policy for each zone. Finally, the optimized layout solution is tested under demand uncertainty in the third, final simulation phase, through a discrete‐event simulation model. The SOS methodology was validated with three months of operational data from a large retailer's warehouse, successfully illustrating how it may be successfully used for improving the performance of a distribution warehouse.
- 1 January 2020
- Published by Springer Nature
- p. 227-232
Understanding Production Process Productivity in the Glass Container Industry: A Big Data Approach
- 1 January 2020
- Published by Springer Nature
- p. 227-232
Understanding Production Process Productivity in the Glass Container Industry: A Big Data Approach